In$the$event$that$“EA”$is$often$displayed,$it$may$be$necessary$to$clean$the$inside$of$the$
machine:$
1) Switch$off$the$machine$and$disconnect$the$power$supply.$
2) Unscrew$and$remove$the$3$screws$near$the$bottom$of$the$cover.$
3) Remove$the$cover$and$clean$the$coin$sensor,$sorting$disc$and$back$plate$with$a$brush$
or$cloth.$Remove$foreign$coins/objects.$
$
7-C7DE'This$means$a$counting$sensor$is$impeded.$There$are$2$counting$sensors$located$at$the$
top$of$each$coin$channel.$E1$indicates$the$coin$channel$with$the$smallest$diameter$is$
impeded;$E8$has$the$largest$coin$channel$diameter.$
$
To$unblock$the$counting$sensors:$remove$any$coins$that$have$become$jammed$in$the$coin$
channel,$see$5.2$and$clean$both$counting$sensors$with$a$brush$or$cloth.$ $
$
7F:$This$means$the$speed$sensor$is$impeded.$To$unblock$the$speed$sensor$follow$the$steps$
below:$
1) Switch$off$the$machine$and$disconnect$the$power$supply.$
2) Unscrew$and$remove$the$3$screws$near$the$bottom$of$the$cover.$
3) Remove$the$cover$and$clean$the$speed$sensor$with$a$soft$cloth.$The$speed$sensor$is$
located$on$the$right$hand$side,$just$above$the$sorting$disc.$ $
@.'/;#&1$1&%+1)*,'
•Operating$temperature$range:$0$~$40°C.$
•Operating$humidity$range:$30$~$80%.$
•Hopper$capacity:$Max.$500$coins.$
•Coin$tray$capacity:$Max.$300$coins.$
•Denomination$display:$3$digit$LED$
•Counting$number$display:$4$digit$LED$
•Power$source:$AC220[240V/50Hz$or$AC110V/60Hz$
•Power$consumption:$<20W$
•Dimensions:$345$x$306$x$260$mm$
•Net$weight:$3.2$KG$
•Counting$speed:$Max.$220$coins/minute$
$
If$the$machine$has$a$fault$that$you$are$unable$to$resolve,$please$contact$your$local$ZZap$
dealer.$
$
Products$are$subject$to$change$without$further$notice.$
$
$
$