Programming the Device on the GC2/GC3 Panel
For GC2 and GC3 panels, program the Stove & Grill Guard on your
2GIG panel with the following parameters. (Please refer to your
panel’s quick programming guide for the actual steps.)
Sensor Type: (23) No Response Type
Sensor Equipment Type: Contact
Equipment Code: (0862) 2GIG Thin Door/Window Contact1
Serial Number: [Input the unique 7-digit TXID.]2
Equipment Age: New
Sensor Loop Number: 2
Dialer/Transmission Delay: Enabled
Voice Descriptor: GAS LEFT ON3
Sensor Reports: Enabled
Sensor Supervised: Disabled
Sensor Chime: [User-specified]
1 This is a provisional Equipment Code. A new category called
“Stove & Grill Guard” (or similar name) will be added in a future
GC2/GC3 panel update.
2 Alternavely, a Stove & Grill Guard can be automacally learned in.
3 This is a recommended voice descriptor. The user may define a
custom voice descriptor, as needed.
Programming the Device on the Vario Panel
For the Vario panel, aer learning in1the Stove & Grill Guard, please
configure the zone the Stove & Grill Guard is in with the following
parameters:
Zone Type: Output Trigger
Zone Sound Armed Away:
Silent
Zone Sound Armed Stay: Silent
Zone Sound Disarmed: Chime or Silent
1Alternavely, you can use the Vario TXID to manually enroll the
device.
Programming the Device on the Honeywell Vista Panel
For the Honeywell Vista panel, first enroll the Stove & Grill Guard
into the panel as follows:
•For Panel 15P, 20P or 50P, auto-enroll the device into the panel.
The LED will flash 6 mes to confirm the enrollment.
•For Panel 10SE or 20SE, set the address to "00", then auto-enroll.
The LED will be solid green to confirm the enrollment.
Then program the panel as follows:
1. Enter [4-digit installer code], then [800], then [*56]. When the
screen displays "Set to Confirm?" press [*] buon.
2. When prompted by the screen to "Enter ZN Num" input a
chosen zone number (ZN) between 09 and 48, then press [*]
buon.
3. Type in the ZN to display the current zone summary on the
screen.
4. Enter the following parameters:
•ZT (zone type): [10]
•P (paron): [1]
•RC (report code): [01] then [0010]
•IN (input device type): [RF Trans. 3]
•Transmier Serial Number: [A] then [7-digit TXID]
•Loop Number: [2]
5. Confirm the zone summary displays the parameters correctly.
Setting up E-mail Notification
–
Alarm.com Accounts Only
1. Navigate to hƩp://www.alarm.com and click LOGIN.
2. Your systems dashboard page will appear. Select the Security tab
and click Sensors.
3. Idenfy the new sensor you added. You can rename the
Sensor Name. When finished, click Save.
4. Click the NoƟficaƟons tab, and then +New NoƟficaƟon
buon to create a new event. The menu will appear with
the Standard tab open by default.
5. Click Sensor LeŌOpen. Add parameters. Also, click +Add
Recipient to add recipients associated with the noficaon.
6. Click Close when names have been selected, then click Save
NoƟficaƟon.
Specifications
• Signal Range: 100 . open-air from a 2GIG panel
• Transmission Frequency: 345 MHz
• Disc dimensions: 2.2” diameter, 0.21” thickness
• Operang Temperature: 14°F to 167°F (-10°C to 75°C)
• Baery Life: Up to 5 years
FCC & IC Notice
This device complies with Part 15 of the FCC Rules and Industry Canada license
exempt standard(s). Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
received that may cause undesired operaon.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables
aux appareils radio exempts de licence. L’exploitaon est autorisée aux deux
condions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’ulisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est suscepble d’en compromere le fonconnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protecon against harmful interference in a residenal
installaon.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instrucons may cause harmful
interference to radio communicaons. However, there is no guarantee that
interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television recepon, which can be
determined by turning the equipment offand on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separaon between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
• Consult the dealer or an experienced radio/TV technician to help
WARNINGS:
• Changes or modificaons not expressly approved by the manufacturer could
void the user’s authority to operate the equipment.
• The Stove & Grill Guard is not intended as a life-safety device. It is not
intended to replace any other safety consideraons.
Limited Warranty
This Nortek Security & Control product is warranted against defects in material
and workmanship for 12 months. Nortek Security & Control does not warrant
this product to consumers.
There are no obligaons or liabilies on the part of Nortek Security & Control
for consequenal damages arising out of or in connecon with use or
performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installaon, or reinstallaon.
All implied warranes for funconality, are valid only unl the warranty expires.
This Nortek Security & Control LLC Warranty is in lieu of all other warranes
expressed or implied.
For technical support in the USA and Canada:
800.421.1587
Email: 2gigtechsupport@nortek.com
Visit www.nortekcontrol.com for technical support hours of operaon
For technical support outside of the USA and Canada:
Contact your regional distributor
Visit dealer.2gig.com for a list of distributors in your region
Patent Pending.
2GIG® is a registered trademark of Nortek Security & Control LLC.
10017336A X2