Installation Instructions:
LUNOS e2 and e2 short with
5/UNI-FR No.:40269 Controller
CONTENTS
Questions? Email: [email protected] | Call: 800-995-6329 1
About this manual, Safety instructions
Technical Specifications
Dimensional Diagrams
Installation Position
Operating Conditions
Shipping Units
Assembly: Assembly pipe and outside grid
Assembly: Electric installation and electric connection
Assembly: Heat recovery unit and indoor blind
Operation
Controller Dial Settings / Flow Rate Selection
Filter Indicator Reset + Summer Vent Mode Operation
1
1
2
2
2
3
3 - 4
4 - 5
6
6
7
7
ABOUT THIS MANUAL
● Read this manual carefully and completely before assembly. Comply with the general safety instructions
symbols with information in the text.
● Hand out this manual to the user (tenant, proprietors, property management, etc.) after completing
assembly.
Symbols in this manual
⚠ This symbol is a danger warning in connection with risk of injury or product malfunction
This symbol is a danger warning in connection with risk of injury from electricity
Safety instructions
Beware! Any assembly work to the ventilation device may only be carried out after disconnecting all
phases of supply currents! The ventilation device is fitted with protective insulation according to Protection Class
II, the protection connection is superfluous!
⚠ Attention! The electric connection may only be authorized by qualified electricians according to the local
building codes.
⚠ Attention! This device may not be operated (including filter replacements/cleaning) by children and persons
who are not able to operate the device safely due to their abilities, or Lack of knowledge.
Device voltage: 12 VDC SELV
Type of protection: IP 22
Volume flow: 10;15;20 CFM or
(9CFM-15m3/h;18CFM-30m3/h,22CFM-38m3/h)
Measuring sound pressure level: 16,5 dB; 19,5 dB
Sound level difference: 42 dB
UL: fans are certified to the UL 507-2010: Electric
Fans 9th Edition
TECHNICAL SPECIFICATIONS DISPOSAL
Dispose of the packaging correctly
sorted. If you want to dispose of the
device, abide by the current rules and
regulations. The applicable municipal
office will provide information.
DIMENSIONAL DIAGRAMS (All dimensions in inches (mm)
Questions? Email: [email protected] | Call: 800-995-6329 2
INSTALLATION POSITION
OPERATING CONDITIONS
Ductless e2 ventilation devices with heat recovery can only function in pairs operation in opposite directions.
Each fan operates 70 seconds (50 seconds for e2 short) in supply air operation, the other 70 seconds (50
seconds for e2 short) in exhaust air operation at the corresponding set flow rates. After which both air flows
directions are changed. This assures that the total of supplied ventilation volume is equal to the total exhausted
volume. If a pair of fans in this balanced push-pull operation is installed in two different rooms of a dwelling, a
sufficiently dimensioned interconnection (undercut door, etc.) between the rooms should be installed to allow
unrestricted air movement between these spaces. Please see the product page at foursevenfive.com for videos.
Rated conditions: 5ºF to 104ºF (-15ºC to +40ºC) with relative humidity up to 65%.
During the heating period it is possible for very small amounts of condensation to form on grills if such conditions
arise. If these limitations of use are exceeded for extended periods of time, the device can be closed with the
indoor cover. Do ensure IAQ is maintained in such cases.
OPERATING CONDITIONS
SHIPPING UNITS
Questions? Email: [email protected] | Call: 800-995-6329 3
OPERATING CONDITIONS
ASSEMBLY – INSTALLATION PIPES
Check the shipment to
ensure all items ordered
have been received. Note
any missing items or
damages to 475 ASAP and
include photos if possible.
Contact: [email protected]
e2 : Installation pipe, exterior
white grill, heat exchange unit,
indoor cover, optional
condensate ring, and
installation instructions are
supplied as a complete set.
e2 short: Installation pipe,
exterior white grill, heat
exchanger unit, indoor cover,
optional condensate ring, and
installation instructions are
supplied as a complete set.
Indoor CoverHeat Exchange Unit
Outside Grill
Installation Pipe
Make the wall openings for the assembly pipes
(e.g. by coring, core bit Ø 6.37"/162mm).
If necessary, shorten the pipe to the desired
installation length e2 minimum 11.8"(300 mm):
e2 short minimum 8" (200 mm).
Take care that the pipe extends on both sides for
finishes (sheetrock plaster, siding) with finishes
Installed flush with the pipe.
Insert the pipe, with a min. 3/8:12 (3mm) pitch
and airseal it with ROFLEX 150 gaskets,
TESCON tapes or other airtight solutions.
ASSEMBLY – INSTALLATION PIPES (continued)
Questions? Email: [email protected] | Call: 800-995-6329 4
ASSEMBLY - ELECTRIC INSTALLATION AND ELECTRIC CONNECTION
Apply exterior finishes and waterproofing with
ROFLEX/TESCON tape combination or other
construction type specific measures.
Remove the construction protection lid outdoors. Insert
and attach the exterior grill using the integrated claw
fasteners (tighten screws). Make sure the exterior grill
mounted with the louvers directing rain away from the
tube. Exterior grill finishes are also available in:
stainless steel, grey, burgundy, and white.
Safety Instructions: Beware! Any assembly work to the ventilation device may only be carried
out when all of the supply current has been disconnected! Make sure that all electrical circuits are
turned off. All controllers of this ventilation system should be installed on a AFCI protected circuit.
⚠Electric connection only by a licensed electrician.
● The system is controlled by
Universal Control 5/UNI-FR.
● Select the location for the switch.
● Run the wiring (120V + 12V cables
to the device pairs).
● 120V cable (14 gauge).
● 12V to each fan (3 x 18 gauge solid
thermostat wire).
● Controller is wired and set per
diagram on following page.
4
ASSEMBLY - ELECTRIC INSTALLATION AND ELECTRIC CONNECTION (continued)
Questions? Email: [email protected] | Call: 800-995-6329
Use the following cables for the electric connection:
● Cable to the ventilation units: 18/3 solid
● Cable for the supply voltage to the transformer/ power supply unit 14 gauge
Double Rocker Switch Connection
W1 W2 grey
red
black
Rocker switch front view
Rotary Switch Connection
grey
red
black
Device connection
5
5
transformer
Set coding dial to the functions requested in accordance with the table on
page 7. Selecting the wrong dial setting can lead to malfunctions!
⚠
Important! Set coding
dial to the desired
functions (see page 7).
ASSEMBLY– VENTILATION INSERT AND INDOOR ROOM COVER
Questions? Email: [email protected] | Call: 800-995-6329
OPERATION
6
Remove interior protection lid cover, insert heat
exchange unit into the installation pipe, ensure there is
a ⅞" gap on interior of pipe. Motor/fan faces interior.
The loop on fan unit can be used to pull unit for
maintenance.
Connect wiring to plug. Connect plug into socket and
set them into the recess of the heat exchanger casing.
Insert interior cover with filter casing, snap the interior
blind into place in open position (¼” off wall).
If cover completed covered, lift cover and rotate 180°.
Installation is now complete.
When operating the Lunos e2 using a double-rocker
switch, apply the provided sticker to the switch plate
as shown. The markings on the sticker correspond to
the following:
● Both W1 + W2 OFF = Level 0
● Switch W1 ON = Level I
● Switch W2 ON = Level II
● Both W1 + W2 ON = Level III
When operating the Lunos e2 with the optional 475
Rotary Switch, the switch positions correspond to
the following (assume a clock face):
● 12:00 (position 0) = Level 0
● 1:00 (position 1) = Level I
● 2:00 (position 2) = Level II
● 3:00 (position 3) = Level III
W1 W2
Sticker placement
Dial
position Fan type
Programs and airflow Activate alternate operation mode
Level 0 Level I Level II Level III
W1 OFF W1 ON W1 OFF W1 ON
W2 OFF W2 OFF W2 ON W2 ON
0 RA 15-60 OFF 10 cfm 20 cfm 25 cfm
1 RA 15-60 OFF 10 cfm 20 cfm 35 cfm
2 RA 15-60 10 cfm 20 cfm 25 cfm 35 cfm
3 e² OFF 10 cfm 15 cfm 22 cfm e² short
4 e² 10 cfm 15 cfm 20 cfm 22 cfm e² short
5 e² 60 OFF 10 cfm 15 cfm 25 cfm e² 60 short
6 e² 60 5 cfm 10 cfm 15 cfm 25 cfm e² 60 short
7 e² 60 OFF 10 cfm 20 cfm 35 cfm e² 60 short
8 e² 60 10 cfm 20 cfm 25 cfm 35 cfm e² 60 short
9 ego OFF 3 cfm 6 cfm 26 cfm* Level III HRV 10cfm
A ego 3 cfm 6 cfm 10 cfm 26 cfm* Level III HRV 10cfm
B ego 6 cfm 10 cfm 26 cfm* 26 cfm* Level III HRV 10cfm
C e² 60** OFF 10 cfm 20 cfm 35 cfm e² 60 short
D e² 60** 10 cfm 20 cfm 25 cfm 35 cfm e² 60 short
E 0-10 V
CONTROLLER DIAL SETTINGS
Questions? Email: [email protected] | Call: 800-995-6329
* Exhaust air without heat recovery
** Unpaired operation with 1 unit connected to S1 and two units connected to S2.
7
●The LED will permanently light in red when the filter is due to be cleaned or replaced. Remove front cover,
take filter out, and insert new or cleaned filter. Filters can be washed by hand, or in a dishwasher. MERV13
or Pollen filters cannot be washed.
●Period of summer vent mode lasts 8 hours, then will automatically revert to normal operation.
FILTER INDICATOR RESET + SUMMER VENT MODE OPERATION
Functions Double Rocker Switch Rotary Switch LED Indicator Light
Reset filter
indicator
Rocker W1 one time
within 3 seconds
Rotating from Level 0 to I and
back to 0 (within 3 seconds)
Blinks red 3 times
Activate
summer
vent mode
Rocker W2 one time
within 3 seconds
Rotate dial from I to II and back
to I again (within 3 seconds)
Lights green once for
3 seconds
Deactivate
summer vent
mode
Rocker W2 one time
within 3 seconds
Rotate dial from I to II and back
to I again (within 3 seconds)
Blinks green twice
(1 second each)

This manual suits for next models

1

Popular Fan manuals by other brands

Ruck Ventilatoren DHA 190 E4P Assembly instruction

Ruck Ventilatoren

Ruck Ventilatoren DHA 190 E4P Assembly instruction

TroposAir 3LA44 owner's manual

TroposAir

TroposAir 3LA44 owner's manual

urban ambiance UHP9060 installation manual

urban ambiance

urban ambiance UHP9060 installation manual

Taurus ALPATEC BOREAL 12 LEGEND instruction manual

Taurus

Taurus ALPATEC BOREAL 12 LEGEND instruction manual

TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C... installation instructions

TJERNLUND

TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C... installation instructions

Cata DUCT IN LINE 100/270 TIMER Installation, operation and maintenance instructions

Cata

Cata DUCT IN LINE 100/270 TIMER Installation, operation and maintenance instructions

NuAire MRXBOX-ECO3-1Z installation manual

NuAire

NuAire MRXBOX-ECO3-1Z installation manual

Vent Xpress Advocate 59371 installation guide

Vent Xpress

Vent Xpress Advocate 59371 installation guide

Dimplex DCACE20R instruction manual

Dimplex

Dimplex DCACE20R instruction manual

Lasko T32200 Important instructions & operating manual

Lasko

Lasko T32200 Important instructions & operating manual

Streetwize Cyclone II manual

Streetwize

Streetwize Cyclone II manual

Faro Barcelona Veneto manual

Faro Barcelona

Faro Barcelona Veneto manual

Morris MTF-16227 user manual

Morris

Morris MTF-16227 user manual

Goobay 39510 user manual

Goobay

Goobay 39510 user manual

Trisa electronics 9346.43 Instructions for use

Trisa electronics

Trisa electronics 9346.43 Instructions for use

Gibbons Fans FP5005 Instruction manual and  warranty information

Gibbons Fans

Gibbons Fans FP5005 Instruction manual and warranty information

Craftsman Builder Deluxe BLD52-3 light installation guide

Craftsman

Craftsman Builder Deluxe BLD52-3 light installation guide

Panasonic FV-08VS1 Installation instruction

Panasonic

Panasonic FV-08VS1 Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.