VES FALA100/12V/TR User manual

FALA100/12V/TR
12V Bathroom Extract Fan
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: [email protected] web: www.ves.co.uk
Original Instructions : Installation, Operation & Maintenance Manual
ID Ref 915b • August 2014
Original Instructions : Installation, Operation & Maintenance Manual Original Instructions : Installation, Operation & Maintenance Manual
This manual must be read in full before Installation, Operation and
Maintenance of the units supplied. Please ensure that this document is
passed to the end user. This manual forms an integral part of the product
and should be kept for the working life of the product. Additional copies of
this and supporting documents are available by contacting VES or by
visiting www.ves.co.uk and following the 'Download O & M's' link.
IMPORTANT
The following symbols used within this document refer to potential dangers
or advice for safe operation
Indicates hazards associated with electric current and high
voltages
Indicates hazards that require safety advice for personnel
and/or potential unit/property damage
Indicates important information
fans are suitable for installation in Zone 1 and beyond the
zoning area (see below) The transformer be located beyond ZONE 2.
IMPORTANT
MUST
All FALA fans must be sited and installed in accordance with current IEE
Regulations BS7671 and the appropriate Building Regulations.
FALA100/12V/TR
FALA100/12V/TR is suitable for wall mounting only.
The fan should be installed in conjunction with an appropriate mounting kit
and consideration must be given to ensure that access to all moving parts of
the fan are restricted when the fan is in use.
Unit Description
The axial fan is suitable for bathroom extract applications;
for full unit details please see the unit specification later in the document.
Immediately upon receipt of your fan, check there is no
damage to the fan, and that the four fixing screws and matching wall plugs
are included within the ancillary bag. Also included is a 12V transformer
part number DMEL1010.
In the event of any damage having occurred or if any item is found to be
missing, it is essential to inform VES Andover Ltd. within 7 days of delivery
quoting sales order number and the unit type. After this period, VES would
be unable to accept any claim for damaged or missing goods.
FALA100/12V/TR
FALA100/12V/TR
FALA100/12V/TR ...............................12V extract fan c/w transformer
Part Number Description
Dimensions ABCDØE FG(mm)
FALA100/12V/TR
DMEL1010
157 157 20 56 98 - - -
(Transformer) - - - - 147 86 66
A
BCD
Ø
1
zone
0
zone
2
zone
2
zone
2
zone
600mm
600mm
600mm
2250mm
IMPORTANT
Before attempting to carry out any work on our units, all accompanying
documentation including warning labels on the unit must be referenced.
Should it be necessary to remove any component ensure that these are
secured into position once reinstalled. It is critical that after any
maintenance work has been conducted that all components removed
/replaced be refitted correctly by a competent engineer.
F
E
G
IMPORTANT
All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulaons.
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes aer electrical disconnecon before
aempng access. This will allow any moving parts to come to a rest.
IMPORTANT
All wiring must be fixed securely and the cable to the fan should be a
minimum of 1.5mm² in secon. A double pole fused spur fied with a
3 amp fuse must be used and must be sited outside any room containing a
shower or fixed bath.
IMPORTANT
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes aer electrical disconnecon before
aempng access. This will allow any moving parts to come to a rest.
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: vesltd@ves.co.uk web: www.ves.co.uk
Original Instrucons : Installaon, Operaon & Maintenance ManualOriginal Instrucons : Installaon, Operaon & Maintenance Manual
WEEE Direcve
Aheend oheir useful life the packaging and product should
be disposed of viaasuitable recycling centre.Do not dispose of
with normal household waste.Do notburn.
Standards
FALA fans conform to all relevant Brish and European
standards and direcves. Further informaon is available
from VES Andover Ltd on request
Pleaseensure thahisdocumenspassed on to theenduser
We reserve the right to alter the specificaon without noce
©VES Andover Ltd. 2010. No part of this publicaon may be
photocopied or otherwise reproduced without the prior
permission in wring of VES Andover Ltd.
Wiring Diagrams
Maintenance
1. Before cleaning, isolate the fan completely from the mains supply.
2. Carefully remove the front cover
3. To clean the front cover, either wipe it with a damp, lint free cloth or
wash it in warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts
of the fan.
5. Never use strong solvents to clean the fan.
6. Apart from cleaning, no other maintenance is required.
For replacement fans or install kits please visit www.vesdirect.co.uk
Specificaon
Power Supply (fan)12V 50Hz. SELV
Operang Temperature 0~40°C
Insulaon ClassDouble insulated
Protecon (fan) IPX4
deveelSepyTrotoM
Power Supply (transformer) 230VAC 50Hz
0562)mpr(deepS
51)W(rewoP
21.0)A(tnerruC
Warranty
The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.
Mark centre holes on
mounng surface then
drill out
Remove cover from
FALA fan
Original Instrucons : Installaon, Operaon & Maintenance Manual
Wire the fan as per
wiring diagram &
instrucons
Cable entry:
Use the cord grip as
provided
boom
Cable entry opons
Prepare hole in mounng
surface & plug mounng
holes as required
Replace front cover
Installaon connued
Secure fan backing
plate to mounng
surface
Standard
(Typical Installaon)
Transformer
DMEL1010
(Not Used)
1
230VAC 50Hz 12V
2
3
4
5
Fuse (3A)
Double Pole
Isolang Switch
LL
NN
Fan Terminals
FALA100/12V/TR
Cable entry:
Use the knock-out as
provided. Remove by hand
taking care not to damage
the surround fan casework
back



Other VES Fan manuals

VES Ecovent EVH Series Manual

VES

VES Ecovent EVH Series Manual

VES ECVD72 User manual

VES

VES ECVD72 User manual

VES Colourfan CLE Series User manual

VES

VES Colourfan CLE Series User manual

VES ecovent EVH User manual

VES

VES ecovent EVH User manual

VES VENA240 Instruction manual

VES

VES VENA240 Instruction manual

VES POLO100 Series Instruction manual

VES

VES POLO100 Series Instruction manual

VES AX315/4-1 Instruction manual

VES

VES AX315/4-1 Instruction manual

VES Ecovent EVHR User manual

VES

VES Ecovent EVHR User manual

VES EURO100 User manual

VES

VES EURO100 User manual

VES POLO150 Instruction manual

VES

VES POLO150 Instruction manual

VES Short Case Axial series Instruction manual

VES

VES Short Case Axial series Instruction manual

VES Colourfan Series User manual

VES

VES Colourfan Series User manual

VES MERA250 User manual

VES

VES MERA250 User manual

VES Roundfan RM100/EC Manual

VES

VES Roundfan RM100/EC Manual

Popular Fan manuals by other brands

Oriental motor MF930 operating manual

Oriental motor

Oriental motor MF930 operating manual

HAMPTON BAY 460-952 manual

HAMPTON BAY

HAMPTON BAY 460-952 manual

Silvercrest SBV 40 A1 Operation and safety notes

Silvercrest

Silvercrest SBV 40 A1 Operation and safety notes

Oriental motor MRE Series operating manual

Oriental motor

Oriental motor MRE Series operating manual

HAMPTON BAY SOUTHWIND 52371 Use and care guide

HAMPTON BAY

HAMPTON BAY SOUTHWIND 52371 Use and care guide

Delta Breez GreenBuilder GBR80 Installation and operating instructions

Delta

Delta Breez GreenBuilder GBR80 Installation and operating instructions

Far Tools Farelek MIAMI 40 Original manual translation

Far Tools

Far Tools Farelek MIAMI 40 Original manual translation

Easy@Home EWCF8B user guide

Easy@Home

Easy@Home EWCF8B user guide

Suncourt CENTRAX TF104 installation instructions

Suncourt

Suncourt CENTRAX TF104 installation instructions

Bigassfans Basic 6 installation guide

Bigassfans

Bigassfans Basic 6 installation guide

Ebmpapst G4E200-BL03-01 operating instructions

Ebmpapst

Ebmpapst G4E200-BL03-01 operating instructions

Newport Medical Instruments Newport HT50 operating manual

Newport Medical Instruments

Newport Medical Instruments Newport HT50 operating manual

Maxxair MAXXFAN Plus 4000KI Installation instructions, Information and Operating guide

Maxxair

Maxxair MAXXFAN Plus 4000KI Installation instructions, Information and Operating guide

Ebmpapst A4D350-AN08-02 operating instructions

Ebmpapst

Ebmpapst A4D350-AN08-02 operating instructions

oneConcept 10029266 manual

oneConcept

oneConcept 10029266 manual

Casa Fan Eco Volare 116 Mounting and operating manual

Casa Fan

Casa Fan Eco Volare 116 Mounting and operating manual

Ebmpapst D3G133-BF03-02 operating instructions

Ebmpapst

Ebmpapst D3G133-BF03-02 operating instructions

Air King 4C945J Operating instructions & parts manual

Air King

Air King 4C945J Operating instructions & parts manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.