A-iPower SUA12000EAP User manual

PORTABLE GENERATOR
Owner’s Manual
Model:
Serial:
Date Purchased:
P/N: 32082-
SUA12000E$P REV0
SAVE THIS MANUAL FOR FUTURE REFERENCE
DO NOT RETURN
TO STORE!
CALL US FIRST
1-855-888-3598
FOR SUPPORT

Table of Contents
Introduction..........................................1
Safety....................................................1
General Safety Precautions....................2
Unpacking the Generator.......................7
Parts Included........................................7
Assembly...............................................7
Install the Wheel Kit................................7
Install the Support Leg............................8
Battery Cable Connection........................8
Controls and Features............................9
Control Panel Features........................10
Specifications.....................................11
CO WATCH-GUARD..............................12
Add Engine Oil......................................14
Low Oil Shutdown................................14
Add Fuel...............................................14
Operation at High Altitude......................15
Grounding............................................15
Connecting to a Building’s Electrical System...15
Operation............................................16
Generator Location...............................16
Surge Protection...................................16
Starting the Generator...........................16
Connecting Electrical Loads..................17
Stopping the Engine..............................18
Low Oil Shutdown................................18
Do Not Overload Generator....................18
Maintenance And Storage....................19
Maintenance Schedule.........................19
Engine Maintenance.............................19
Engine Oil Level Check.......................19
Change Engine Oil..............................20
Spark Plug Maintenance.....................20
Air Filter Maintenance.........................21
Battery Replacement..........................21
Cleaning the Spark Arrestor...............22
Valve Clearance................................22
Generator Maintenance.........................22
Storage................................................22
Trouble Shooting..................................24
Parts Diagram and Parts List................25
Parts Diagram......................................25
Parts List.............................................26
Circuit Diagram....................................28
Warranty..............................................29

INTRODUCTION
SAFETY
Read This Manual Thoroughly
The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The
warnings in this manual and the tags and decals affixed to the unit are therefore not all-inclusive. If you use a
procedure, work method or operating technique that the manufacturer does not specifically recommend you
must satisfy yourself that it is safe for you and others. You must also make sure that the procedure work
method or operating technique that you choose does not render the generator unsafe.
If any section of this manual is not understood,
contact customer Service at 1-855-888-3598, or
www.a-ipower.com for starting, operating and
servicing procedures. The owner is responsible for
proper maintenance and safe use of the unit.
SAVE THESE INSTRUCTIONS for future reference.
This manual contains important instructions that
must be followed during placement, operation and
maintenance of the unit and its components. Always
supply this manual to any individual that will use this
unit.
The information in this manual is accurate based on
products produced at the time of publication. The
manufacturer reserves the right to make technical
updates, corrections and product revisions at any
time without notice.
Page 01
DEFINITIONS AND SYMBOLS
DANGER
Indicates a hazard
which, if not avoided,
will result in death or
serious injury.
WARNING
Indicates a hazard
which, if not avoided,
could result in death
or serious injury.
NOTICE
Indicates information
considered important,
but not hazard-related
(e.g.,messages relating
to property damage).
CAUTION
Indicates a hazard
which, if not avoided,
could result in minor
or moderate injury.
WARNING
Read and understand manual completely
before using product. Failure to
completely understand manual and
product couldresult in death or serious
injury.
WARNING
Operating, servicing, and maintaining this equipment
can expose you to chemicals including engine
exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects orother reproductive harm.
To minimize exposure, avoid breathing exhaust, and
wear gloves or wash your hands frequently when
servicing this equipment. For more information go to
www.P65warnings.ca.gov.
The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important
information. Make sure that the meanings of this safety information is known to all who operate, perform
maintenance on, or are nearthe generator.
This safety alert symbol appears with most safety statements. It means attention,become alert, your
safety is involved! Please read and abide by the messagethat follows the safety alerts symbol.

Engine exhaust contains carbon
monoxide, a poisonous gas that could
kill you in minutes. You CANNOT smell
it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Asphyxiation
Hazard
Fire
Hazard
Hot Surface.
Do Not Touch the Surface.
Burn Hazard
Page 02
Kickback
Electric Shock
Hazard
Explosion
Hazard
Moving Parts
Hazard
Operator’s Manual
GENERAL SAFETY PRECAUTIONS
POISONOUS GAS HAZARD
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage,
EVEN IF doors and windows are open.
Avoid other generator hazards. READ MANUAL BEFORE USE.
Only use OUTSIDE and far away
from windows, doors and vents.
The exhaust system must be properly
maintained. Do not alter or modify the
exhaust system as to render it unsafe or
make it noncompliant with local codes
and/or standards. Failure to do so will
result in death or serious injury.
DANGER
Always, install battery operated carbon
monoxide alarm indoors and installed
according to the manufacturer’s
instruction.
• Operate this product ONLY outside far away from
windows, doors and vents to reduce the risk of
carbon monoxide gas from accumulating and
potentially being drawn towards occupied spaces.
DO NOT run this product inside homes, garages,
basements, crawl spaces, sheds, or other
partially-enclosed spaces even if using fans or
opening doors and windows for ventilation. Carbon
monoxide can quickly build up in these spaces and
can linger for hours, even after this product has
shut off.
•ALWAYS place this product downwind and point
the engine exhaust away from occupied spaces. If
you start to feel sick, dizzy, or weak while using
this product, shut it off and get to fresh air RIGHT
AWAY. See a doctor. You may have carbon
monoxide poisoning.
WARNING
If you start to feel sick, dizzy or weak while using
the portable generator, you may have carbon
monoxide poisoning. Get out side to fresh air
immediately and call 911 for emergency medical
attention. Very high levels of CO can rapidly cause
victims to lose consciousness before they can
rescue themselves. DO NOT attempt to shut off the
generator before moving to fresh air. Entering an
enclosed space where a generator is or has been
running may put you at greater risk of CO
poisoning.
WARNING

Page 03
• ONLY use outside and downwind, far away from windows, doors and vents.
• Direct exhaust away from occupied spaces.
CORRECT USAGE
INCORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning
• Near any door, window or vent
• Garage
• Basement
• Crawl Space
• Living Area
• Attic
• Entry Way
• Porch
• Mud Room
Do not operate in any of the following locations:

Page 04
• When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
• NEVER start or stop engine with electrical devices
plugged in and turned on.
Starter cord kickback (rapid retraction)
will pull hand and arm toward engine
faster than you can let go which could
cause broken bones, fractures, bruises,
or sprains resulting in serious injury.
WARNING
DANGER
WHEN ADDING OR DRAINING FUEL
• Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap
slowly to relieve pressure in tank.
• Fill or drain fuel tank outdoors.
• DO NOT overfill tank. Allow space for fuel
expansion.
• If fuel spills, wait until it evaporates before starting
engine.
• Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
• Check fuel lines, tank, cap, and fittings frequently
for cracks or leaks. Replace if necessary.
• DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap, and air
cleaner are in place.
• DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
• DO NOT operate this product inside any building,
carport, porch, mobile equipment, marine
applications, or enclosure.
• DO NOT tip engine or equipment at angle which
causes fuel to spill.
• DO NOT stop engine by moving choke control to
“Start” position.
Fuel and its vapor are extremely flammable and
explosive. Add fuel in a well ventilated area. Keep
sparks, open flames and other ignition sources away.
Failure to do so will result in death and serious injury.
DANGER
DANGER
Do not overfill tank. Allow space for fuel expansion. If
fuel spills wait until it evaporates before starting
engine. Failure to do so will result in death and
serious injury.
WHEN TRANSPORTING, MOVING OR REPAIRING
EQUIPMENT
• Transport/move/repair with fuel tank EMPTY or
with fuel shutoff valve OFF.
• DO NOT tip engine or equipment at angle which
causes fuel to spill.
• Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
• Store away from furnaces, stoves, water heaters,
clothes dryers, or other appliances that have pilot
light or other ignition source because they could
ignite fuel vapors.
Generator voltage could cause electrical
shock or burn will result in death or
serious injury.
DANGER
Never use generator in wet or damp
locations. Never expose generator to
rain, snow, water spray while in use.
Protect generator from all hazardous
weather conditions. Moisture, or ice
can cause a short circuit or other
malfunction in the electric circuit. Water
contact with a power source if not
avoided, will result in death or serious
injury.

WARNING
WARNING
WARNING
When operating machine, do not touch
hot surfaces. Keep machine away from
combustibles during use. Hot surfaces
could result in severe burns or fire.
WARNING
• Use a ground fault circuit interrupter (GFCI) in any
damp or highly conductive area, such as metal
decking or steel work.
• DO NOT use generator with electrical cords which
are worn, frayed, bare or otherwise damaged.
• DO NOT allow unqualified persons or children to
operate or service generator.
DANGER
Contact with terminals, bare wires and
electrical connections when generator
is running will result in death or serious
injury.
DANGER
WHEN ADJUSTING OR MAKING REPAIRS TO
YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark
plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Exhaust heat/gases could ignite combustibles,
structures or damage fuel tank causing a fire,
resulting in death or serious injury.
Contact with muffler area could cause burns
resulting in serious injury.
• It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any
forest-covered, brush-covered, or grass-covered
land unless the exhaust system is equipped with a
spark arrester, as defined in Section 4442,
maintained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for the exhaust system installed on this
engine.
• Allow equipment to cool before touching.
• Replacement parts must be the same and installed
in the same position as the original parts.
• DO NOT wear loose clothing, jewelry or anything
that could be caught in the starter or other rotating
parts.
Starter and other rotating parts could
entangle hands, hair, clothing, or
accessories. Keep away from rotating
parts, failure to do so could result in
death or serious injury.
Unintentional sparking could cause fire or electric
shock resulting in death or serious injury.
Fire and electrocution hazard. Do not connect to a
building's electrical system unless the generator and
transfer switch have been properly installed and the
electrical output has been verified by a qualified
electrician. The connection must isolate the
generator power from utility power and must comply
with all applicable laws and electrical codes.
Excessively high operating speeds could result in
minor injury. Excessively low operating speeds
impose a heavy load.
CAUTION
Page 05

Page 06
•DO NOT tamper with governor spring, links or other
parts to increase engine speed. Generator supplies
correct rated frequency and voltage when running
at governed speed.
•DO NOT modify generator in any way.
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices
connected to it.
• DO NOT exceed the generator’s wattage amperage
capacity.
• Start generator and let engine stabilize before
connecting electrical loads.
• Connect electrical loads in OFF position, then turn
ON for operation.
• Turn electrical loads OFF and disconnect from
generator before stopping generator.
NOTICE
NOTICE
Improper treatment of generator could damage it and
shorten its life.
• Use generator only for intended uses.
• If you have questions about intended use, ask
dealer or contact local service center.
• Operate generator only on level surfaces.
• DO NOT expose generator to excessive moisture,
dust, dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• If connected devices overheat, turn them off and
disconnect them from generator.
• Shut off generator if:
-Electrical output is lost.
-Equipment sparks, smokes, or emits flames.
-Unit vibrates excessively.
Medical and Life Support Uses.
• In case of emergency, call 911 immediately.
• NEVER use this product to power life support
devices or life support appliances.
• NEVER use this product to power medical devices
or medical appliances.
• Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
• Inform your electrical provider immediately if a loss
of power would cause you or anyone in your
household to experience a medical emergency.
WARNING

Page 07
UNPACKING THE GENERATOR
Parts Included
Your gasoline powered generator ships with the
following parts:
NO.
1
2
3
4
5
6
7
8
9
10
11
12
*
Qty
2
2
2
2
2
2
1
1
1
1
1
1
1
Item Description
Wheels (9.5" Flat Free)
Axle Pin
Flat Washer
Cotter Pin
Flange Bolt M8x16
Flange Lock Nut M8
Support Leg with Vibraion Mounts
Spark Plug Wrench
Oil Bottle (1.0L)
Owner's Manual
Quick Start Guide
12V DC Battery Charging Cable
Built-in Handle
• Open carton completly. Remove and verify carton
content prior to assembly. Your generator ships
with following items.
• Call our customer service at 1-855-888-3598 with
the unit model and serial number for any missing
item.
• Record model, serial number, and date of purchase
on front cover of this munual for your own record.
9 10
8
11
1
2
3
4
6
5
7
ASSEMBLY
Install the Wheel Kit
NOTE:
The wheels are not intended for over-the-road use.
1 - place generator on a flat surface.
2 - Tip the generator on a piece of cardboard or
other soft material to protect the frame paint and
prevent the generator from sliding.
Your generator requires some assembly prior to
usage.
Assembly the generator will require lifting the unit.
Always have assistance when lifting the generaotor.
CAUTION
Do not plug in or turn on the generator until it is fully
assembled according to the instructions. Failure to
completely understand manual and product could
result in death or serius injury.
Call our customer service at 1-855-888-3598 for any
assembly issues or concerns. Please have model
and serial number available.
WARNING
12

Page 08
ASSEMBLY
NOTE:
Handle already is assembled on the unit.
IMPORTANT: Before operating the generator the
shock-absorbing seat (K) must be adjusted for
clearance. Loosen the lock nut (L) and adjust the
shock absorbing seat (K) so there is about 3-4mm
gap between the top of the seat and the bottpm of
the alternator bracket (M). Re-tighten the lock nut
after adjustment.
3-4mm
3 - Slide axle pin (A) through the wheel (B), flat
washer (C) and generator frame axles hole (D).
4 - Secure everything with cotter pin (E). Repeat on
opposite side.
Install the Support Leg
5 - Insert bolts (F) throught the support leg (G) and
holes on the generator frame as shown.
6 - Tighten bolts (F) and nuts (H) to the frame.
M
K
L
M
K
L
A
B
C
D
E
G
F
H
Battery Cable Connection
NOTE: The generator comes equipped with the
positive cable (A) (with red boot) already attached.
1. Verify the positive (+) battery cable (A) with red
boot is securely tightened to the positive (+)
battery post. Make sure boot is over battery post.
2. Remove bolt (B) (M6x12) and nut (C) from battery
negative (-) post.
3. Locate negative (-) battery cable (D) with black
boot and attach to the negative (-) battery post.
Tight the cable with bolt (B) and nut (C). Cover the
post with black boot.
A
BD
C

Page 09
CONTROLS AND FEATURES
1 - Choke Lever
2 - Control Panel
3 - CO Sensor
4 - Fuel Valve
5 - Frame
6 - Fuel Tank
7 - Fuel Cap
8 - Fuel Gauge
9 - Spark Plug
10 - Air Filter
11 - Recoil Starter
12 - Engine
13 - Oil Filler Cap/Dipstick
14 - Battery
15 - Handle
16 - Alternator Cover
17 - Support Leg
18 - Muffler/Spark Arrester
19 - Carburator
20 - Wheel
12 3 4 5
10 11 12 13 14
67 8 9
15 16 17 18 19 20

Page 10
CONTROL PANEL FEATURES
1. Hour Meter: Displays and records how many
hours your generator has run (up to 9,999.9).
2. Low Oil Indicator: The Light will be illuminated
when the engine oil level is low. Add oil.
3. CO(Carbon Monoxide) WATCH-GUARD Indicator
Light (Red for Shutoff and Yellow for Service):
The CO(Carbon Monoxide) WATCH-GUARD
monitors for the accumulation of poisonous CO
gas around the generator produced by engine
exhaust when the generator is running. If the CO
WATCH-GUARD detects increasing levels of CO
gas, it automatically shuts off the engine. See CO
WATCH-GUARD section for more information.
4. Main Breaker: The main breaker controls total
output of all outlets to protect the generator from
overload or short circuit.
5. 120V AC, 20A Duplex, GFCI, Single Phase, 60 Hz
Outlets (5-20R): Each outlet is capable of
carrying a maximum of 20 amps on a single outlet
or a combination of both outlets.
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
6. Circuit Breaker: Protects the generator against
electrical overloads.
7. 120/240V AC, 50A, Single Phase, 60 Hz Outlet
(NEMA 14-50R): This outlet can supply either 120
Volt or 240 Volt output up to 50 amps.
8. Engine Control Switch: To start engine manually,
flip the switch to RUN (I) position and pull recoil
starter. To start engine with electric start, press
and hold the switch on the START (II) position
and the engine will crank and attempts to start.
When the engine starts, release the switch to the
RUN (I) position.
9. 12V DC, Outlet (Automotive): Provides 12 volt DC
power up to 8.3 amps.
10. Ground Terminal: The ground terminal is used to
ground the generator.
11. 120/240V AC, 30A Twist Lock, Single Phase,
60 Hz Outlet (NEMA L14-30R): This outlet can
supply either 120 Volt or 240 Volt output up to
30 amps.
1
86 9 10 6 11
23 4 5 6 5 7 6 6

Page 11
SPECIFICATIONS
Model
Starting Watts
Running Watts
Rated AC Voltage
Rated DC Voltage
Rated Frequency
Phase
Grounding System (AC)
Engine Type
Engine Displacement
Starting System
Low Oil Shutdown
Oil Type
Oil Capacity
Spark Plug OEM Type
Spark Plug Replacement Type
Spark Plug Gap
Valve Intake Clearance
Valve Exhaust Clearance
Voltage Regulation System
Alternator Excitement System
Total Harmonic Distortion (THD)
Fuel Tank Capacity
Fuel Type
Maximun Ambient Temperature
Battery Spec
Certifications
SUA12000E$P
12000W
9000W
120/240V
12V
60HZ
Single
Neutral Bonded to Frame
Single Cylinder, 4-Stroke OHV Air Cooled
459cc
Recoil/Electric
Yes
10W-30
37.2 fl.oz (1.1L)
F7RTC
NGK BPR7ES or Champion RN9YC
0.028~0.031inch (0.7~0.8mm)
0.004~0.006inch (0.1~0.15mm)
0.006~0.008inch (0.15~0.2mm)
AVR
Brushed
Standard
Gal (25L)
Gasoline
104°F (40°C)
12V, 14Ah
EPA-F(7/-PGMA Compliant
Generator Specifications
NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F(40°C). If
needed, this product can be operated at temperatures ranging from 5°F(15°C) - 122°F(50°C) for short periods.
If the product is exposed to temperatures outside of this range during storage, it should be brought back within
this range before operation. This product must always be operated outdoors in awell-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F(6°C) above 60°F( 16°C) ambient temperature.

Page 12
CO WATCH-GUARD
Carbon Monoxide (CO) Detection and Auto Shutoff System
Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and
safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the
generator produced by engine exhaust when the generator is running. If the CO sensor detects increasing levels
of CO gas, it automatically shuts off the engine.
Generators are intended to be used outdoors and far away from occupied buildings, windows, doors and
exhaust pointed away from them.
NOTIFICATIONS: BLINKING RED AND YELLOW LIHGT
There is a CO indicator light on the control panel with two possibilities:
1-Blinking Red Light provides notification that the generator was shutoff due to an accumulating CO level
around the generator. The red light will blink for at least five minutes after a CO shut off. Automatic shutoff is an
indication generator was improperly located. Move the generator to an open, outdoor area far from occupied
spaces with exhaust pointed away. Once relocated to a safe area, the generator can be restarted. The red light
will stop blinking automatically after 2-5 seconds upon engine re-start.
If you start to feel sick, dizzy, weak, or your homes carbon monoxide alarm sounds while using the generator,
get to fresh air right away. Call emergency services. You may have carbon monoxide poisoning.
However, if the generator misused and operated in a location that results in the accumulation of CO inside an
enclosed or partially enclosed space, CO WATCH- GUARD automatically shuts off the engine and notifies the
user of what has happened and directs the user to read the instruction of CO WATCH-GUARD Action Label for
steps to take.
CO WATCH-GUARD ACTION LABEL • ÉTIQUETTE D’ACTION • ETIQUETA DE FUNCIONAMIENTO
WARNING:
TAMPERING WITH CO WATCH-GUARD COULD RESULT IN HAZARDOUS CONDITION.
ADVERTISSEMENT:
L’ALTÉRATION DE WATCH-GUARD CO PEUT ENTRAîNER DES CONDITIONS DANGEREUSES.
ADVERTENCIA:
HACER ALTERACIONES CON WATCH-GUARD CO PODRíA OCASIONAR CONDICIONES PELIGROSAS.

120V AC, 20A Duplex GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI) receptacles. In the event of a ground fault,
a GFCI trips automatically to stop the flow of electricity and prevent serious injury. The LED Indicator Light on
the receptacle will be turn off. Press the “RESET” button located on the front of the receptacle to restore flow of
electricity. GFCI does NOT protect against circuit overloads. To ensure proper operation of the GFCI duplex,
perform this test monthly:
1. With the generator running, plug a test lamp into the GFCI receptacle. Turn the lamp on.
2. Press the “TEST” button located on the front of the receptacle to trip the device. This should immediately stop
the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has
been serviced or replaced.
3. Press the “RESET” button located on the front of the receptacle to restore the flow of electricity. If the LED
Indicator Light does not come back or GFCI cannot be reset, then it must be replaced.
2-Blinking Yellow Light provides notification that a CO WATCH-GUARD fault has occurred and no longer
provides protection. The generator is shutoff automatically and the yellow light will blink for at least five minutes
after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the
sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it
to original settings.
Page 13
DO NOT modify or tamper with the Carbon Monoxide Detecting System (CO WATCH-GUARD). Not following
these instructions could result in death or serious injury due to Carbon Monoxide detecting system malfunction.
CO WATCH-GUARD will detect the accumulation of carbon monoxide from other fuel burning sources such as
engine powered tools used in the area of operation. If another generator is used and the exhaust is pointed at a
CO WATCH-GUARD equipped generator, the CO WATCH-GUARD may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide has been detected. You must take action to
move and direct the equipment to better dissipate carbon monoxide far away from people or buildings.
CO WATCH-GUARD only monitors when the generator is running.
CO WATCH-GUARD DOES NOT replace carbon monoxide alarms.
Tempering with the CO WATCH-GUARD will void your warranty.
WARNING
Tampering with CO WATCH-GUARD could result in a hazardous condition. Removing the CO WATCH-GUARD
module will not allow the generator to start.
WARNING
Receptacle
LED Indicator Light
Outlet
Reset Button
Test Button
Outlet
TEST MONTHLY
RESET
TEST
FOLLOW DIRECTIONS

A
B
Do not attempt to crank or start the engine before
it has been properly filled with the recommended
type and amount of oil. Damage due to operation
with no oil will void your warranty.
We consider the first 5 hours of run time to be the
break-in period for the unit. During the break in
period stay at or below 50% of the running watt
rating and vary the load occasionally to allow stator
windings to heat and cool. Adjusting the load will
also cause engine speed to vary and help seat piston
rings.
Add Engine Oil
We recommend using SAE 10W-30 APISJ oil for
best performance. Other high-quality detergent oils
(APISJ or higher) are acceptable. Do not use special
additives. Ambient temperature determines the
proper oil viscosity for the engine. Use the chart to
select the proper oil for the outdoor temperature
range expected.
Low Oil Shutdown
The unit is equipped with a low oil shutdown. If the
oil level becomes lower than required, the sensor will
activate a warning device or stop the engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting at
an angle that forces oil to shift. Place on an even
surface to correct this. If engine fails to start, the oil
level may not be sufficient to deactivate low oil level
switch. Make sure the sump is completely full of oil.
Add Fuel
Fuel must meet these requirements:
• Clean, fresh, unleaded gasoline.
• Use regular UNLEADED gasoline with the generator
engine with a minimum 87 octane / 87 AKI (91
RON). Do not use E85 or E15.
For high altitude use, see "Operation at High
Altitude".
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
1. Place generator on a flat, level surface.
2. Clean area around oil fill and remove yellow oil fill
cap/dipstick (A).
3. Wipe dipstick clean.
4. Using oil funnel, slowly pour contents of provided
oil bottle into oil filler neck (B) to the "H" mark on
dipstick. Be careful do not overfill. Overfilling with
oil could cause the engine to not start or hard
starting.
5. Replace oil fill cap/dipstick (A) and fully tighten.
6. Oil level should be checked prior to each use or at
least every 8 hours of operation. Keep oil level
maintained.
-20 0 20 40 60
Ambient temperature
Recommended Engine Oil Type
80 100 120
-28.9
°F
°C -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
10W-30
5W-30 Full Synthetic
10W-405W-30
H
L
NOTICE
NOTICE
DANGER
Fuel and its vapor are extremely flammable and
explosive. Add fuel in a well ventilated area. Keep
sparks, open flames and other ignition sources away.
Failure to do so will result in death and serious injury.
DANGER
Do not overfill tank. Allow space for fuel expansion. If
fuel spills wait until it evaporates before starting
engine. Failure to do so will result in death and
serious injury.
Page 14

Page 15
• DO NOT mix oil in gasoline.
• DO NOT modify engine to run on alternate fuels.
WHEN ADDING FUEL
• Fill fuel tank outdoors.
• DO NOT overfill tank. Allow space for fuel
expansion. If the tank is overfilled, fuel can overflow
onto a hot engine and cause fire or explosion.
• If fuel spills, wait until it evaporates before starting
engine.
• Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently
for cracks or leaks. Replace if necessary.
• DO NOT light a cigarette or smoke when filling the
fuel tank.
Operation using an alternative main jet at elevations
lower than the recommended minimum altitude can
damage the engine. For operation at lower elevations,
the standard main jet supplied must be used.
Operating the engine with the wrong main jet may
increase exhaust emissions, fuel consumption and
reduce performance.
It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel hose
or tank during storage. Alcohol-blended fuels (called
gasohol, ethanol or methanol) can attract moisture,
which leads to separation and formation of acids
during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid
engine problems, the fuel system should be emptied
before storage of 30 days or longer. See the "Long
Term Storage" section. Never use engine or
carburetor cleaner products in the fuel tank as
permanent damage may occur.
Operation at High Altitude
At altitudes over 5,000 feet(1524 meters), a
minimum 85 octane gasoline is acceptable. Engine
power and generator output will be reduced
approximately 3.5% for every 1000 feet (305 m) of
elevation above sea level. High altitude may cause
hard starting, increased fuel consumption and spark
plug fouling. To operate at high altitudes A-iPower
can provide a high altitude carburetor main jet. The
alternative main jet and installation instructions can
be obtained by contacting Customer Support.
Grounding
The national electrical requires your generator must
be connected properly to an appropriate ground to
help prevent electric shock.
The generator has a system ground that connects the
generator frame components to the ground terminals
on the AC output receptacles. There may be Federal
or State regulations, local codes, or ordinances that
apply to the intended use of the generator. Consult a
qualified electrician, electrical inspector, or the local
agency having jurisdiction. This generator is not
intended to be used at a construction site or similar
activity as defined by NFPA 70-2020 (NEC) section
590.6.
Connecting to a Building's Electrical System
Connections to your home’s electrical system must
use a listed transfer switch installed by a licensed
electrician. The connection must isolate the generator
power from the utility power and comply with all
applicable laws and electrical codes.
1. Remove the fuel cap (A) slowly.
2. Slowly add unleaded fuel to fuel tank. Be careful
not to fill above the red fuel level indicator (B).
This allows adequate space for fuel expansion.
3. Install fuel cap and let any spilled fuel evaporate
before starting engine .
B
A
NOTICE
NOTICE
WARNING
Shock hazard. Failure to properly ground
the generator can result in electric shock.

OPERATION
Generator Location
Surge Protection
Starting the Generator
Make sure you review each warning in order to
prevent fire hazard.
• Keep area clear of inflammables or other
hazardous materials.
• Select a site that is dry, well ventilated and
protected from the weather.
• Keep exhaust pipe clear of foreign objects.
• Keep generator away from open flame.
• Keep generator on a stable and level surface.
• Do not block generator air vents with paper or
other material.
Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range
and may be affected by momentary voltage
fluctuations. While there is no way to prevent voltage
fluctuations, you can take steps to protect sensitive
electronic equipment.
Install UL1449, CSA-listed, plug-in surge
suppressors on the outlets feeding your sensitive
equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fluctuations.
3. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
4. Turn the fuel valve to the “ON” position.
1. Before starting the generator, check for loose or
missing parts and for any damage which may
have occurred during shipment.
2. Check oil level and fuel.
5. Move the choke lever to the “START” position.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage,
EVEN IF doors and windows are open.
Avoid other generator hazards. READ MANUAL BEFORE USE.
Only use OUTSIDE and far away
from windows, doors and vents.
ON
START
WARNING
DANGER
Never use generator in wet or damp
locations. Never expose generator to
rain, snow, water spray or standing
water while in use. Protect generator
from all hazardous weather conditions.
Moisture, or ice can cause a short
circuit or other malfunction in the
electric circuit. Water contact with a
power source if not avoided, will result
in death or serious injury.
Page 16

Page 17
6. Starting the Generator (Electric / Recoil start)
6-1. Electric start
Press and hold switch on the “START”(II)
position. Engine will crank and attempts to
start. When the engine starts, release the
switch to the “RUN” (I) position.
Connecting Electrical Loads
This unit has been pretested and adjusted to handle
its full capacity. Before starting the generator,
disconnect all loads. Apply load only after generator
is running. Voltage is regulated via the engine speed
adjusted at the factory for correct output.
Re-adjusting will void warranty.
NOTE:
Keep choke lever in “START” position for only 1 pull
of the recoil starter. After first pull, move choke lever
to the “RUN” position for up to the next 3 pulls of the
recoil starter. Too much choke leads to sparkplug
fouling/engine flooding due to the lack of incoming
air. This will cause the engine not to start.
If engine starts after 3 pulls but fails to run. Or if unit
shuts down during operation, make sure unit is on a
level surface and check for proper oil level in
crankcase. This unit may be equipped with a low oil
protection device. If so, oil must be at proper level
for engine to start.
NOTE:
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1. Let engine stabilize and warm up for a few minutes
after starting.
2. Ensure circuit breaker on control panel is in on
position.
3. Plug in and turn on the desired 120 or 240 Volt
AC, single phase, 60Hz electrical loads. It is better
to attach the item with largest load first.
6-2. Recoil start
Flip the engine switch to the “ON”(l) position.
Pull the starter cord slowly until resistance is
felt and then pull rapidly.
RUN
7. Do not over-choke. As soon as engine starts and
warms up, move the choke lever to the “RUN”
position.
8. Allow generator to run at no load for few minutes
upon each initial start-up to permit engine and
generator to stablize.
When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
Starter cord kickback (rapid retraction)
will pull hand and arm toward engine
faster than you can let go which could
cause broken bones, fractures, bruises,
or sprains resulting in serious injury.
WARNING

Page 18
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with electrical
devices plugged in or turned on.
Let the generator run at no-load for two minutes to
stabilize internal temperatures of the engine and
generator.
Do Not Overload Generator
Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and to
connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
OFF
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart
the engine.
3. Contact Customer Service.
4. DO NOT operate engine until oil level is corrected.
NOTE:
Always ensure that the fuel valve is in the “OFF”
position when the engine is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.
2. Press the engine switch to the “OFF”(O) position.
Do not leave the generator until it has completely
stopped.
2min
3. Turn the fuel valve to the “OFF”(O) position.
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death or serious injury.
DO NOT stop engine by moving choke control to
“START” position.
WARNING
Table of contents
Languages:
Other A-iPower Portable Generator manuals

A-iPower
A-iPower AP4000 User manual

A-iPower
A-iPower SUA4500 User manual

A-iPower
A-iPower SUA12000ED User manual

A-iPower
A-iPower AP5000 User manual

A-iPower
A-iPower SUA2700iD User manual

A-iPower
A-iPower SUA2700i User manual

A-iPower
A-iPower SUA9000E User manual

A-iPower
A-iPower SUA4000i User manual

A-iPower
A-iPower SUA5000P User manual

A-iPower
A-iPower DUAL FUEL Series User manual