Operation&Testing
RoutineTesting ofsmokedetectors should bedoneonceamonth.
To testtheAJ-765smokedetectors press thetestbuttonfor less than1
second. Thesounder should activate.
Any other linked detectors shouldalso activate within20 seconds.
Thesmokedetectors sounder will automaticallyreset,whenall thesmoke
has cleared.
Hushfeature. Whenthesmokedetector hasbeenactivated, pressing the
testbuttonfor less than1second will silencethat smokedetectors sounder.
Indication:
GreenFlashevery60seconds, Detector is performingcorrectly
Red Flashevery8seconds plus beep, Faulty, Clean/Replacementrequired
Red Flashevery50seconds plus beep, BatteryLow, Replacementrequired
Red Flashing withNobeeping, inHushmodefor 9minutes
*Whenusinganyaerosolsmoke detectortester,please followall instructions pro-
vided onthe can.Improperuse may resultindegradeddetectorperformance.
**Routine cleaning is requiredtoensure nofalse triggers.
AJ-765
Auto ResettingSmoke Detector
withWirelessInterconnect
Specifications
DetectionType:PhotoelectricChamber
Power Source:Batteryup to 10year life
Buzzer Output:85db @3meters
Wireless Frequency:433MHz
InterconnectRange:up to 50meters apart
Dimensions:40mm x Ø110mm
Operating Temp. Range:0 C to40 C
Compatiblewith:AJ-718 Heat Detector
AJ-R106 Remote Test& HushController
Standards:EN14604:2005/AC:2008
& AS3786:2014
Kitchen
Dining
Room
Living
Room
Bathroom
Bedroom
BedroomBedroom
Bedroom
= Musthave Location (within3metersofeverybedroomdoor)
= RecommendedLocations
= Optional HeatDetector (AJ-718)
500mm min.
1500mm max.
300mm min.
300mm min.
500mm max.
Exposed
Beams
=Dead Air Space
(don’t fithere)
Mounting Clearances
*Alwaysreferto lateststandards/building codeformounting locations
V1.01OP