Charge
Duration
Model Number Discharge
Duration Battery
TECHNICAL INFORMATION
Power
Input
Voltage
Operation
PrimEvo RS100E
Non-maintained
24h 3 h
220-240V~
50Hz Ni-Cd,7.2V 1000mA NM: 1.6W
Snap fixture with spring into
mounting hole.
45
Press the test switch, indicator
will go out, emergency light will
light on.
Fixed cable locker.
Connect battery connector,
Snap battery pack on housing.
6
¢100
SERVICE AND OPERATION
INSTALLATION
Cut out mounting hole in ceilling,
hole dimension is 100mm.
1
Remove battery pack from housing,
remove cable locker.
2
Feed the power cable through
the mounting hole and connect
to terminal block on fixture.
3
L Live (Brown)
N Neutral (Blue)
¢100
Brown
Blue
VDE H03VVH2-F 0.75 X 2C
VDE H03VVH2-F 0.75 X 2C
GENERAL INFORMATION
PRECAUTIONS
CAUTIONS
INSTALLING AND CONNECTING
The luminaire should be connected to the voltage equivalent to that indicated on the type label.
The surface mounted luminaire is fitted with a terminal block suitable for loop-in-loop-out connection.
For further information on the different connection possibilities, see the instructions in this instruction
leaflet.
PLEASE NOTE!
Constant voltage is required and the batteries must be sufficiently charged for emergency lighting to
function properly. Failure to observe this requirement can damage the batteries, the light source or in
worst-cast scenario. the luminaires electronics.
INSPECTION AND MAINTENANCE
The company strongly advises annual inspection of your emergency lighting installation.
3 of 42 of 4
Normal Operation: The green indicator light on the bottom unit stays on.
The LED will go out if the mains supply fails, if the internal charger is malfunctions, or if the unit is in test
mode. The fixture must be charged for 24 hours after installation.
Battery: Sealed Nickel-Cadmium rechargeable battery pack. Batteries of a different type must not be
used. Batteries should be replaced by authorised service personnel only. If the unit no longer maintains
its rated battery backup test times. Should only be replaced by competent service personnel with
manufacturers battery pack. Old Battery's should be recycled.
Test Switch: If pressed the test switch, LED indicator will go out and the fixture will operate from its
battery supply.
This product should be installed by a registered electrician in accordance with local standards and
electrical regulations. Take care to ensure the mains supply is isolated before installation. Check the
unit label for correct supply voltage and frequency.
LED emergency light, down light style, self-contained lighting, for pathway and door light used
optional. LED light source provides low power consumption and long life. Enclosure is made by
polycarbonate, recessed mounting or surface mounting.
The luminaire will, under no circumstances, be covered with insulating material or similar material
only current style
Replace the battery when the battery no longer meets its rated duration of operation (see the label of
battery replacing) .
Carefully read this instruction leaflet before installing or using the luminaire. This leaflet provides
important information about the correct installation, use, maintenance and disposal of this product.
Please observe the following guidelines:
1. The luminaire should only be installed by qualified personnel. Installation must be in accordance
with European installation requirements HD 60364 and additional local regulations.
2. This product may not be modified in any way what so ever or used for a purpose or in an environment
other than for which it is designed. Failling to observe these guidelines will invalidate the warranty
and the CE-compliance of this product.
3. The luminaire is suitable for indoor use only
4. Before installing the luminaire, the supply must be isolated.
5. The light source in this luminaire is non-replaceable.
English
Maintained and Non-maintained function
Maintained : Assemble
wire
connector
Non - maintained
:
Disassemble
wire
connector
Wire connector
Maintained