Access ROYALE Manual

INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS
ACCESS TUBS
5701 NW 35 Avenue
Miami, FL 33142
Phone 877-249-2388
Fax 866-560-1060
http://www.accesstub.com
MODEL
ROYALE
Costco Model # 1075666/1075667
WHIRLPOOL BATHTUBS


INSTALLATION INSTRUCTIONS & OWNER’S MANUAL
(Refer to individual model sheets for specications)
BEFORE BEGINNING INSTALLATION, CHECK THE FOLLOWING ITEMS
AND READ THE INSTRUCTIONS CAREFULLY.
CHECK ENTIRE UNIT FOR CONCEALED DAMAGE. If there is any damage, DO NOT INSTALL!
Shipping damages must be reported to the carrier immediately. All damage must be discovered
and reported prior to installation in order to have it covered under the warranty!
COMPARE COLOR OF UNIT WITH OTHER FIXTURES. If color is not sufciently compatible with
xtures, DO NOT INSTALL!
PLANNING THE INSTALLATION
1. Make certain the oor structure is level and adequate to support installation. See oor loading in
tub specications.
2. Building codes require that a panel(s) be constructed to allow ample clearance for plumbing repairs
and pump service or removal. (Please refer to your local codes for regulations.)
3. Using the tub itself, or installation drawings, measure and mark locations for waste pipe, water
supply, wiring runs, and service access.
IMPORTANT SAFETY INSTRUCTIONS
Read and follow all instructions and save these instructions.
WARNING! Examine all plumbing for damage and water test before nal installation. If
damage has occurred, call our Technical Service Department at 877-249-2388.
WARNING! Alterations or modications of the plumbing system without expressed written
authorization will invalidate all warranty claims.
WARNING! Installation must comply with current local and state building, plumbing, and
electrical codes.
WARNING! It is the responsibility of the installer or owner to determine code requirements
prior to installation.
WARNING! Connections should be made by licensed plumbers and electrician.
IMPORTANT INSTRUCTIONS:
* Do Not lift by plumbing at any time! Lift by the tub deck.
* Tub must be supported by the suboor and bedding, not by the tub lip.
* Run pump and test all functions and plumbing prior to nishing installation.
* Run pump only when water in tub is two inches over jets.
The plumbing system on all ACCESS Tubs meets ASME, and UL standards.
Any modications to the plumbing system, including the pump, will void the warranty and approvals.
IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, AND INJURY.
SAVE THESE INSTRUCTIONS!

READ AND FOLLOW ALL INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. INSTRUCTIONS IMPORTANTES
RELATIVES A LA SECURITE.
READ AND FOLLOW ALL INSTRUCTIONS. LIRE ET SUIVRE TOUTES LES
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS. CONSERVER CES INSTRUCTIONS.
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING; CHILDREN
SHOULD NOT USE HYDROMASSAGE BATHTUB WITHOUT ADULT
SUPERVISION. AVERTISSEMENT. RISQUE DE BLESSURE ET DE NOYADE.
NE PAS LAISSER UN ENFANT UTILISER LA CUVE A REMOUS EN
L’ABSENCE D’UN ADULTE
WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR
EXITING THE HYDROMASSAGE BATHTUB. AVERTISSEMENT. POUR
EVITER LES BLESSURES, USER DE PRUDENCE EN ENTRANT DANS LA
CUVE A REMOUS ET EN LA QUITTANT.
WARNING: RISK OF ELECTRIC SHOCK; DO NOT PERMIT ELECTRIC
APPLIANCES (SUCH AS A HAIR DRYER, LAMP, TELEPHONE, RADIO,
OR TELEVISION) WITHIN 1.5 M OF THIS HYDROMASSAGE BATHTUB.
AVERTISSEMENT. RISQUE DE CHOC ELECTRIQUE. NE PAS PLACER
D’APPAREILS ELECTRIQUES (LUMINAIRE, TÉLÉPHONE, RADIO,
TELEVISEUR, ETC.) A MOINS DE 1.5 M DE CETTE CUVE A REMOUS.
CAUTION: TEST THE GROUND FAULT CIRCUIT INTERRUPTER
PROTECTING THIS APPLIANCE PERIODICALLY IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS. ATTENTION. VERIFIER
REGULIEREMENT LE FONCTIONNEMENT DU DISJONCTEUR DE FUITE A
LA TERRE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT.
1. DANGER: To reduce the risk of injury, do not permit
children to use this unit unless they are closely supervised
at all times.
2. Use this unit only for its intended use as described in this
manual. Do not use attachments not recommended by
the manufacturer.
3. Never drop or insert any object into any opening.
4. Do not operate this unit without the guard over the suction
fitting.
5. The unit must be connected only to a supply circuit that
is protected by a Ground-Fault Circuit Interrupter (GFCI).
Such a GFCI should be provided by the installer and
should be tested on a routine basis.To test the GFCI push
the test button.The GFCI should interrupt power. Push the
reset button. The power should be restored. If the GFCI
fails to operate in this manner, there is a ground current
flowing indicating the possibility of an electrical shock.
Do not use this unit. Disconnect the unit and have the
problem corrected by a qualified service representative
before using.
6. A green colored terminal (or a wire connector marked `G’,
`GR’, `GROUND’, or `GROUNDING’) is provided within
the terminal compartment. To reduce the risk of electrical
shock. connect this terminal or connector to the grounding
terminal of your electrical service or supply panel with a
continuous green insulated copper wire equivalent in size
to the circuit conductors supplying the equipment. but no
smaller than No.10 AWE (5.6mm)
7. A pressure wire connector on your bath is provided on
the exterior of the terminal box within this unit to permit
connection of a No. 8 AWE (8.4mm) solid copper bonding
conductor between this unit and all electric equipment
and exposed metal in the vicinity, as needed to comply
with local requirements.
8. SAVE THESE INSTRUCTIONS.
Check tub for concealed damage.
Check color compatibility with other xtures.
Check to insure that the bath has the proper compo-
nents.
ACCESS Tubs will not be held responsible for tub
damage or color compatibility problems after
whirlpool is installed.
ACCESS Tubs will not be held responsible for cost of
installation or repair if an incorrect tub is installed.
Read instructions before starting installation.

CONSTRUCTION
The tub surface is made of Lucite XL® Acrylic. The
substructure is a composite laminate constructed of fire
retardant fillers.
ELECTRICAL
Wired for 110 Volt 20 Amps with 3 outlets one for each
component (pump, blower, chromalight). Ground-Fault Circuit
Interrupter (GFCI) is required.
The unit must be connected only to a supply circuit that is
protected by a Ground-Fault Circut Interrupter (GFCI). Such
a GFCI should be provided by the installer and should be
tested on a routine basis.To test the GFCI push the test button.
The GFCI should interrupt power. Push the reset button. The
power should be restored. If the GFCI fails to operate in
this manner, there is a ground current flowing indicating the
possibility of an electrical shock.
ELECTRICAL ROUGH-IN
WARNING: When using electrical products basic precautions
should always be followed including the following: Rough-in
wiring to equipment on a Ground-Fault Circuit Interrupter
(GFCI). The GFCI circuit breaker must not supply any other
devices or circuits. An access panel must be installed to
permit pump service.
WARNING: Failure to follow instructions exposes users to
risk of electrical shock or fire.
PLUMBING ROUGH-IN
The bath waste pipe protrudes below the base approximately
one inch. Provide supply pipe, rough-in waste and vent per
local code.
BATH WASTE AND OVERFLOW
Read instructions enclosed with bath waste drain for proper
setting and fitting. Water tight installation of the drain is the
installer’s responsibility.
IT IS THE INSTALLERS RESPONSIBILITY TO
SUPPLY ACCESS TO PUMP AND EQUIPMENT.
1. For Caulking, we recommend 100% sanitary silicone
rather than latex.
2. For quieter operation, you may choose to insulate the
surrounding.
PROTECTION OF TUB
Use a section of the box, cut to size, and place in the bottom
of the tub. When possible, keep the box cover over the tub.
These steps will help protect the tub from abrasion or dam-
age during installation.
CLEAN PUMP SYSTEM
After tub is installed and ready to use, remove all construc-
tion debris and clean the pump and system.
SUGGESTION: During construction, we suggest that you
cover tub to avoid use as trash receptacle.
TESTING
Connect trap to bath waste pipe. Temporarily connect garden
hose for water testing. Tub must be clean before filling. Seal
drain with plug and fill tub 2” above jet fittings. Run pump ap-
proximately 20 minutes. Check for leaks. Turn pump off and
let water sit in tub about 5 minutes. Check for leaks in return
pipe and fittings. Drain the tub and shut off circuit breaker.
NOTE: ALL TUBS ARE FACTORY TESTED FOR PROPER
WATERTIGHT OPERATION. However, the tub must be
filled with water to check for leaks that may have resulted
from handling, before finishing the tub installation. ACCESS
Tubs is not responsible for any defects that could have been
discovered, repaired or avoided by following this testing and
inspection procedure.
GENERAL NOTES
INSTALLATION

The Royale bathtub combines the curvy elegance of a contemporary tub with the classical flair
of a traditional tub. The Royale features a spacious interior and a subtly contoured back rest that
maximizes comfort and relaxation. The uniquely raised crowning along the top is the Royale’s
distinguishing feature and a perfect addition to any bathroom. The whirlpool powered hydro jets and
air powered bubble massage injectors transform your deep soak into a therapeutically relaxing and
rejuvenating bathing experience.
• Fiberglass reinforced high-grade acrylic
• Lustrous glossy white finish
• 8 fully directional and adjustable whirlpool
powered jets, white finish
• 24 bubble massage powered air injectors,
white finish
• Trim matching white finish cable driven
waste and overflow
• Aromatherapy scent infused massage
bubbles
• Chromatherapy color light bathing
• Center drain position along back edge
• One (1) person capacity
• 50 gallon capacity
• 66.8” L x 33.6” W x 24” H
• 150 Lbs.
• 10 Year Limited Warranty
• Interior Depth: 20”
• Interior Length (Top): 63”
• Interior Width (Top): 30”
• Interior Length (Bottom): 39”
• Interior Width (Bottom): 21”
DESCRIPTION
ROYALE DUAL
FOR MAINTENANCE OR REPAIR: The shell
can be removed by flipping the tub over,
locating and removing the 4 plastic nubs and
loosening the securing screws underneath.
Then the entire shell can easily be removed.
3467R
335
8" x 667
8" x 24"
3467R
3467R
3467R
• Before ordering or installing, please consider future access to
equipment.
• Please measure tub on-site before installation
•Jet, pump & blower locations are predetermined and cannot be
changed.
•Make certain the floor structure is level and adequate to support
installation.
•Building codes require that a panel(s) be constructed to allow ample
clearance for plumbing repairs and pump service or removal
•Please note that installer(s) must be certify or warranty will be
voided.
• Specifications and configurations are subject to change without
notice.
• Measurements are +1/2" and are subject to change without
notice.
• Measurements herein supersede all others published prior to
publication date shown below.
OPTIONS
Colors Available - White
Quick Ship - reduces lead time - call for availability
Inline Heater with Pump - Whirlpool or Whirlpool and Air Bath
Lift & Turn Drain Kit -Chrome,Brushed Nickel, White
Color Match Jets.
24 Air jets, Air blower, Textured bottom
IMPORTANT INFORMATION
Whirlpool and Air 3467R
Air jets,
Air blower, textured bottom
ELECTRICAL SPECIFICATIONS:
Required Electrical Service 110 Volt
Air Bath or Whirlpool 1-15 amp GFCI
Whirlpool with Inline Heater 1-20 amp GFCI
Whirlpool and Air 1-20 amp GFCI
Soaker
GENERAL SPECIFICATIONS:
Material Acrylic
Plumbed Weight : 134lbs / 61 kg
Soaker Weight :104 lbs / 47 kg
Average Fill: 50gal to above jet level
©2013 by SPA WORLD CORP Modification Rights Reserved.

INSTALL DRAIN HARDWARE
6. Apply a bead of clear silicone or plumbers putty around
the Drain Body and pass it through the drain hole (figure
3).
7. Apply plumbers putty to the Washer and slide it over the
bottom of the Drain Body (figure 3).
Figure 3
8. Slide the paper washer over the drain body.
9. Attach the Drain Body Nut on the Drain Body and
tighten until the Nut and Washer have created a seal
with the bottom of the bathtub. DO NOT OVERTIGHTEN
(figure 4).
Figure 4
PREPARATION
1. Clean, level and prepare the floor for installation.
2. Place the unit in the exact installed position on the floor
and trace the outline of the bath with a pencil or any
erasable marking (figure 1).
Figure 1
3. Determine the location of the drain pipe, on the floor by
taking measurements of the drain and waste location
underneath the unit (figure 2).
Figure 2
4. Using a blanket, cardboard, or other clean protective
surface, turn the unit on its side so that the unit is properly
supported during drain installation.
5. Clean the drain hole area in preparation of setting the
drain. The area should be dry and free of any debris.
INSTALLATION
PUTTY SILICONEor

INSTALLATION CONTINUED

INSTALL BATHTUB
1. Apply a generous bead of adhesive or silicone to the
bottom of the tub supports (figure 6).
2. Then apply a bead of tub and tile caulk around the edge
of the base (figure 6)
Figure 6
3. Carefully set tub into position (figure 7) and connect
the drain hardware (previously installed). Finish the
installation of the tail-piece installation.
Figure 7
INSTALLATION CONTINUED
CAULKING
COMPLETE BATHTUB INSTALLATION
19. Fill the tub with water to the overflow and then drain the
tub while inspecting the waste connections below the
floor for leaks. Access from below will be necessary for
this step (figure 8).
Figure 8
20. With the bathtub now in place, wipe off any excess tub
and tile caulk and adhesive where the tub meets the floor.
2 1. Run a bead of tub and tile caulk around the bottom edge
of the bathtub where it meets the floor. Wipe off any
excess caulk with a wet cloth (figure 9). If the tub must be
uninstalled for maintenance or repair completely remove
the caulking.Afterwards throughly clean the bottom of the
shell and reapply caulking.
Figure 9

PLUMBING ROUGH-IN
The bath waste opening protrudes below the base approx-
imately one inch. You may be required to cut a hole in the
subfloor to accommodate bath waste. In slab on grade or
prestressed concrete floors where cutting is not desired, the
tub may be raised up by building the platform higher and
using extra mortar under the tub. If a joist must be notched,
verify that structure will not be weakened. Remove only
what is necessary. Provide supply pipe, rough-in waste and
vent per code.
PLUMBING
PVC Schedule 40 piping, self draining pump and fittings
come completely preplumbed unless requested otherwise.
The pump and whirlpool system are completely contained
within the tub perimeter.
INCOMING POWER ELECTRICAL
Dedicated 110v 20 AMP GFCI with 3 outlets, one for each
component (pump, blower, chromalight). Ground Fault
Circuit Interrupter (GFCI) is required. The GFCI breaker
must not supply any other circuits or devices.
FINISHING
Before finishing with your choice of material, make sure
access entries are available to the pump, bath waste, and
plumbing fixtures. Finish as desired and seal around tub,
preferably with silicone.
NOTE:
1. For Caulking, we recommend 100% sanitary silicone
rather than latex.
2. For quieter operation, you may choose to insulate the
construction area.
3. IT IS THE INSTALLERS RESPONSIBILITY TO
SUPPLY ACCESS TO PUMP AND EQUIPMENT
REMINDER: During construction, we suggest that you
cover tub to avoid use as trash receptacle.
NOTE: To service the blower and other electrical
components the caulking must be removed. Afterwards
the skirt should be cleaned and caulking reapplied.
Standard GFCI 110V, 20 Amps
Blower Electrical Supply
INSTALLATION CONTINUED

INSTALLATION CONTINUED
1. Whirlpool Pressure Adjustor
Use to adjust the strength and pressure of the
whirlpool jets.
2. Whirlpool Jets On/Off Button
Push once to activate the whirlpool pump and
whirlpool jets. Push again to shutdown the
pump and whirlpool jets.
3. Chromatherapy Operation Button
First Press: Activate Chromalight.
Press Button Twice: Cycle through the
available modes and colors.
Press Once: Deactivate Chromalight.
4. Bubble Massage On/Off Button
Press once to turn on the air pump and activate
the Bubble Massage air jets. Press again to
turn off pump and deactivate air jets.
5. 2nd Whirlpool Pressure Adjustor
Use to adjust the strength and pressure of the
whrilpool jets.
6. Aromatherapy Cap
Unscrew to insert/remove aroma scented
beads for the Aromatherapy system.
123 4 56
123 4 5
6
ACCESS TUBS ROYALE DUAL SYSTEMS CONTROLS

INSTALLATION CONTINUED
For any maintenance or repair the Royale shell can be removed by flipping the tub over, lo-
cating and removing the 4 plastic nubs and loosening the securing screws underneith. Then
the entire shell can easily be removed.
If the tub is fully installed but must be uninstalled for maintenance or repair the caulking
must be removed completely, the tub must be cleaned and new caulking is to be applied for
reinstallation.

USER SHOULD periodically flush operating system (not to exceed 90 days). As a minimum, shall consist of filling and running
system and draining. Access Tubs recommends flushing with a mild solution of water and sanitizer such as chlorine or other
commercially available whirlpool bath flushing products.
DO NOT use abrasives. They may dull or scratch surface of the acrylic.
DO NOT use oil based solvents. Clean with only a damp cloth or mild detergent or any common glass cleaner.
DO NOT use bubble bath while the whirlpool is operating.
DO NOT turn on pump without water in the bathtub. To do so may cause damage to the pump.
DO NOT alter the position of the pump. To do so may void your warranty.
FOR MINOR SCRATCHES
The procedure to remove light surface scratches or burnish marks is quite easy. Simply apply rubbing compound to the affected
area and buff lightly. Then apply paste wax and gently buff again to return the original shine.
REPAIR TO THE SURFACE
Should a deep scratch or more serious damage be encountered, please call Technical Service at Access Tubs for assistance.
When calling, please have the serial number, date of purchase, and color of your tub.
CLEANING RECOMMENDATIONS
To clean the pipes and pump:
Fill the tub and pour a cup of bleach (or dishwasher soap [i.e. Cascade] if bleach is not available), run pump for five (5) minutes
and let it sit for ten (10) minutes. Run the pump for five (5) minutes, then rinse two (2) times. Wipe off the surface after the rinse
because the bleach may discolor some color trimmings.
After using bleach or dishwasher soap, you should follow this cleaning procedure:
Fill the tub with water and run the pump for 5 minutes, then rinse it 2 times. Clean with a soft damp cloth, do not use abrasive
cleaners as they may scratch and dull surface of the unit.
HEAT STROKE - The most susceptible people are very young, the elderly, alcoholics, and most people under the influence of
drugs.
SYMPTOMS - Hypothermia causes loss of salt, sweating, ordinary dizziness, headache, dryness of the mouth, nausea, faint-
ness and/or unconsciousness, convulsions, flushed appearance of the skin and rapid pulse, and/or weak or shallow breathing.
TREATMENT - Place on back, head slightly elevated, apply wet cloths or ice to the head, wrap body in sheet while pouring on
small amounts of water, cool shower or bath, and get medical attention as soon as possible.
PROBLEM
Pump not starting
Pump humming but not priming
Pump not moving water
No jet pressure
Leak in plumbing
SOLUTION
Check wiring; Check the on/off switch; Check water level; Reset GFI at outlet.
Air trapped in line; Check for clogged jets. Add water, may have to open top union.
Possible obstruction in impeller. Possible frozen clutch (requires replacement).
Clogged jet; air control not open; jet not open; missing part in jet.
Call Tech Service: 877-249-2388
NOTE: Caustic drain openers will damage the surface and the pump! Extreme heat from portable heaters
and cigarettes can damage the surface of the tub. DO NOT USE OIL BASED BATH ADDITIVES.
USER MAINTENANCE
PRECAUTIONS
TROUBLESHOOTING

10 YEARS STRUCTURAL
BATH SHELL: Access Tubs warrants its bath shells against loss of
water through the fiberglass laminate of the tub body as a result of a
defect in materials and workmanship, for a period of ten (10) years
from the purchase date.
10 YEARS SURFACE
The acrylic surface is warranted against blistering, cracking and
chipping resulting from a defect in the acrylic surface material for a
period of ten (10) years from the purchase date. SCRATCHES ARE
NOT COVERED UNDER WARRANTY.
1 YEAR PUMP • 1 YEAR BLOWER • 1 YEAR PARTS
PLUMBING AND EQUIPMENT
Access Tubs warrants factory installed plumbing parts and fittings,
and electrical components to be free from defect in materials and
workmanship for a period of one (1) years from the purchase date, a
period of one (1) years from the purchase date for the pump, and a
period of one (1) years from the purchase date for the blower.
EXTENT OF WARRANTY/RESPONSIBILITY OF PURCHASER
This warranty applies only to original purchaser of the Access Tubs.
Warranty Card must be signed and sent to Access Tubs within ten
(10) days of purchase to activate warranty. Original purchaser must
establish, by dated sales slip, invoice or delivery receipt, the date of
purchase. The warranty applies to Access Tubs manufactured after
October 1, 2010.
WARRANTY PERFORMANCE
In the event of any defect in workmanship or materials covered under
the terms of the “Bath Shell” warranty, Access Tubs will repair the
defect and will be responsible for the labor cost incurred by its agent
in doing so. Travel, trip or mileage costs incurred by the authorized
agents are not covered under this warranty. Access Tubs, at its sole
discretion, may elect to replace the defective bath. All costs involved
in replacing the unit are not covered under this warranty.
In the event of any malfunction or defect covered under the terms
of the “Plumbing and Equipment” warranty, Access Tubs will repair
or replace the defective item for a period of one (1) years from the
purchase date for parts, a period of one (1) years from the purchase
date for the pump, a period of one (1) years from the purchase date
for the blower. Labor cost to repair an Access Tubs is covered
for a period of ninety (90) days and must be performed by an
authorized agent of Access Tubs. The purchaser is responsible to
provide adequate access to the equipment and plumbing. Any labor
costs attributed to removing decking or any other obstacle to
gain easy access to the equipment or plumbing are not covered.
Travel, trip or mileage costs incurred by the authorized agent for
in-home service are not covered under this warranty.
Written notice of any malfunction or defect must be given within ten
(10) days of the time it is discovered, to Access Tubs, 5701 NW 35th
Avenue, Miami, Florida 33142. Access Tubs reserves the right to
inspect the malfunction or defect on location.
RESPONSIBILITIES OF OTHERS
Inspecting the unit prior to installation is the responsibility of the
installer or building contractor who acts on behalf of the user. They
are responsible for ensuring the unit is free of defect or damage.
Notices are placed on and in the unit and on the shipping carton
advising the installer of this responsibility. In the event of a problem,
the unit must not be installed. Access Tubs is not responsible for
failures or damage that could have been discovered, repaired, or
avoided by proper inspection and testing prior to installation.
Damage occurring in transit is the responsibility of the carrier.
The user or installer MUST open the crate and inspect the unit
for damage when it is delivered. If damage is discovered, it must
be reported immediately to the seller and the carrier in writing,
and an inspection requested. Failure of the carrier to respond
should be reported to the seller and the carrier. Your freight
claims should be filed promptly thereafter.
LIMITATIONS AND EXCLUSIONS
This warranty does not cover any claim arising from abuse, misuse,
negligence, accident, improper installation or operations on the part
of the purchaser. This warranty is void if the Access Tubs is subject
to alteration, or if repairs are attempted by anyone other than an
authorized agent of Access Tubs. This warranty does not extend to
plumbing or components installed by dealers, installers or by any
party other than Access Tubs.
Access Tubs will not be liable for loss of use of the Access Tubs,
inconvenience, or any other incidental or consequential costs,
expense or damages. Please note that some states do not allow the
exclusion or limitation of incidental damages.
DISCLAIMER
Except as expressly provided, there shall be no warranty or obligation,
express or implied, oral or statutory. No dealer or other person has
the authority to make any warranties or representations concerning
Access Tubs or its products. In no event shall Access Tubs be held
responsible for any such warranties or representations.
OTHER RIGHTS
This warranty gives you specific legal rights, and you may have other
rights which may vary from state to state.
TECHNICAL SERVICE
Contact the retail seller or the local authorized warranty service
center. If you do not know who your local representatives are, contact
Access Tubs Service Department at the address listed below, or call
877.249.2388.
LIMITED WARRANTY COVERAGE
READ CAREFULLY, THE WARRANTY APPLIES ONLY TO ORIGINAL OWNER
Access Tubs • A Division of SpaWorld Corp.
5701 NW 35th Avenue, Miami, Florida 33142

NOTES
INSTALLER INFORMATION
DATE OF INSTALL:
INSTALLER’S NAME:
PLUMBER: CONTRACTOR:
LICENSE #:


M a d e i n
U S A
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
INSTALLER: SAVE INSTALLATION INSTRUCTIONS WITH HOMEOWNER
HOMEOWNER: KEEP INSTALLATION INSTRUCTIONS FOR FUTURE REFER-
ENCE
Please leave owner’s manual with warranty.
If you have any problems or questions during installation,
please call technical service at
877-249-2388
Record the numbers here for handy reference:
Model No.
Serial No.
Date of Purchase
Manufactured by
Access Tubs
A Division of Spa World Corp.
5701 NW 35th Avenue
Miami, Florida 33142
Ph: 877.249.2388 • Fax: 866.560.1060
10-1011
WHIRLPOOL BATHTUBS
Table of contents
Other Access Bathtub manuals
Popular Bathtub manuals by other brands

CAHABA
CAHABA SACHA CA401006 installation instructions

DURAVIT
DURAVIT Happy D.2 7 0316 Series Mounting instructions

Bibby Sterilin
Bibby Sterilin Stuart SWB6D Instructions for use

Laufen
Laufen LIVING manual

Kohler
Kohler K-1111-H2 Homeowner's guide

American Standard
American Standard Lifetime 2422LA Specifications