Do Do not
2
3
4
Wash your hands with warm water and soap and 
rinse well. Dry your hands thoroughly with a clean 
towel before obtaining blood.
Do not perform a blood 
glucose test if your fingers 
are unwashed, soiled or 
sticky (for example, due to 
food or drink residue).
Always use a small, fresh and well-formed blood 
drop.
Do not perform a blood 
glucose test with a smeared 
or spread blood drop. Do not 
smear the blood drop on the 
test area.
Touch the test area gently and steadily when applying 
the blood drop. Apply the blood drop to the centre of 
the test area.
Do not press the test area 
and the finger together. 
Avoid trembling or shaky 
movements.
Apply the blood drop to the test area immediately 
after you have obtained the blood drop. Remove your 
finger from the test area when the beep tone sounds 
and Test in progress is displayed. Note: You can only 
hear the beep tones when they are turned on. See 
Setting tones in the User’s Manual.
Do not wait before applying 
the blood drop to the test 
area. Do not continue to hold 
your finger on the test area 
after the beep tone sounds 
and Test in progress is 
displayed.
WIMPORTANT INFORMATION FOR PERFORMING A BLOOD GLUCOSE TEST
An incorrectly performed blood glucose test may lead to incorrect test results which can cause the wrong therapy recommendation to be made and thus produce serious 
adverse health eects. Therefore, follow these instructions carefully to perform a blood glucose test correctly.
IMMEDIATELY! DO NOT WAIT!
C
© 2015 Roche Diabetes Care
ACCU-CHEK, ACCU-CHEK MOBILE, ACCU-CHEK SMART PIX, 
ACCU-CHEK 360° and FASTCLIX are trademarks of Roche.
CONTINUA, the CONTINUA logos and CONTINUA CERTIFIED are trademarks, 
service marks, or certification marks of the Continua Health Alliance. 
CONTINUA is a registered trademark in some, but not all countries in which 
this product is distributed.
The USB-IF Logos are trademarks of Universal Serial Bus Implementers 
Forum, Inc.
MRoche Diabetes Care GmbH 
Sandhofer Strasse 116 
68305 Mannheim, Germany 
 
www.accu-chek.com
07438877001(01) – 2015-05 M_Version02_Rev3
0
q
e
w
1
9
2
3
4
5
6
7
8
W 
The Accu-Chek Mobile 
meter and Accu-Chek 
FastClix finger pricker are 
intended for patient self-
monitoring by an 
individual person only.
They must not be used to 
test blood glucose from 
more than one person as 
they do not incorporate any 
features to guard against 
cross-infection. The meter 
and the finger pricker are 
not to be shared between 
family members or used by 
healthcare professionals to 
obtain blood or test blood 
glucose from more than one 
person.
This Quick Start Guide does 
not replace the detailed 
User’s Manual for your 
Accu-Chek Mobile blood 
glucose monitoring system. 
Be sure to comply with the 
safety information in the 
User’s Manual and in the 
package insert of the test 
cassette.
1Release button (priming 
and pricking)
2Power and enter button
3Down/Up buttons
4Window showing number 
of available lancets
5Lever for loading a new 
lancet
6Rotatable cap for setting 
the penetration depth
7Tip cover, closed (below 
right: open)
8Test area (at the tip of the 
cassette ready for a test)
9Lancet drum
0Slide button to release 
the finger pricker
qSlide button to open the 
cassette compartment 
cover
wTip cover
eTest cassette
Why
An incorrectly performed blood 
glucose test may lead to falsely 
elevated blood glucose results 
and thereby delivery of an 
inappropriately high insulin 
amount. Falsely elevated test 
results are caused by the 
following:
• Fingers are unwashed, soiled 
or sticky.
• If the blood drop spreads on 
the finger or if the blood drop 
becomes smeared on the test 
area, the risk of contamination 
of the test area increases (for 
example, due to food or drink 
residue on the finger).
• The test area is pressed 
against the finger. 
• Trembling or shaky 
movements during the blood 
glucose test.
• The blood glucose test is not 
performed immediately or the 
finger stays on the test area 
for too long. Pay attention to 
the beep tone. The beep tone 
helps you to obtain a reliable 
test result.
Quick Start Guide
Start Here
ExA LAN
Approved according to „SOP 04.07.04 – elwo“! The Signature will not be printed!
ONR 7192 – 4all 4692 V4/1 – man_07438877001_01_EN_154x127mm – Black
(2015) Frau Ritzerfeld V4/2 – man_07438877001_01_EN_154x127mm – Cyan
Prüfmittelnummer n/a V4/3 – man_07438877001_01_EN_154x127mm – Magenta
 V4/4 – man_07438877001_01_EN_154x127mm – Yellow
man_07438877001_01_EN.indd 5-6 13.05.2015 16:22:11