AccuTemp XLR81B-00 Series Guide

MP5032-2104
AccuTemp Products INC
11919 John Adams Drive, New Haven, IN 46774
www.accutemp.net
XLR8 HEATED PLATEN
INSTALL, SERVICE AND PARTS
Serial Number:
Model:

MP5032-2104 XLR8 HEATED PLATEN 1
DESCRIPTION PAGE
INSTALLATION & OPERATION
Table of Contents / Document History 1
Safety Warnings 2
General Info 3
Installation 4
Operation 7
Planned Maintenance 11
SERVICE
Sequence of Operation 12
Troubleshoot Guide 13
Removal & Replacement of Parts 16
PARTS 21
Warranty 26
TABLE OF CONTENTS
DOCUMENT HISTORY
Current Revision Date Prior Revision Date Revision
2104 04/14/2021 N/A N/A Original Release

MP5032-2104 XLR8 HEATED PLATEN 2
1. WARNING SYMBOL DEFINITIONS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only
eective if the operator uses proper accident prevention measures. Some of the
symbols are boxed text; while others maybe just picture icons. Please give this
information the respect they deserve for safe operation.
CAUTION -
HOT SURFACE
DANGEROUS
VOLTAGE
EARTH GROUND
DANGER
Indicates an imminently hazardous
situation; which, if unchanged, will
result in death or serious injury.
CAUTION
Indicates a potentially hazardous
situation; which, if unchanged, will
result in minor or moderate injury.
NOTE
Advises the reader of information
or instructions, vital to the
operation or maintenance of the
equipment.
In the event of a power failure, do not attempt to operate this equipment.
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing this equipment.
Only qualified service technicians/electricians should install this equipment to ensure that
all electrical and safety requirements are met and that all wiring is installed in accordance
with all national, state and local electrical codes.
WARNING
WARNING
WARNING

MP5032-2104 XLR8 HEATED PLATEN 3
2. General Information
2.1 Unit Specifications
MM5261-2009
AccuTemp Products, Inc.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
XLR8 Upper Heated Platen (Replace *** with voltage)
Model # XLR8***1B-00
208/1 Amp/ kW 10 A / 2.1 kW
240/1 Amp / kW 11.3 A / 2.7 kW
Breaker Size 15A
Unit Width (1 arm) 11.50
NEMA Plug (208/240) L6-30P
Notes:
1. Each XLR8™ Arm comes with 6’ power cord, separate receptacle
needed for each unit.
2. For use on individual branch circuits only.
®
AccuTemp product may be covered by one or more US Patents. See www.accutempip.net
XLR8™ UPPER HEATED PLATEN
Electric Upper Heated Platen Arm
24 3
8"
(COOKING DEPTH)
20"
4 11
16 "
"
4
UNIT WIDTH
UNIT DEPTH
16
39 1"
24 1
23 7
8"
(COOKING WIDTH)
4
3"22 15
"
5
16
4 8"
3"
16
10
(COOKING HEIGHT)
"
4
3
24
13
31 1
2"
44 13
16 "
Drawing shown with (2) XLR8 Upper Heated Arms
Mounting bracket illustrated and required.
Available in 2’, 3’ or 4’.
MM5261-2009
AccuTemp Products, Inc.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
XLR8 Upper Heated Platen (Replace *** with voltage)
Model # XLR8***1B-00
208/1 Amp/ kW 10 A / 2.1 kW
240/1 Amp / kW 11.3 A / 2.7 kW
Breaker Size 15A
Unit Width (1 arm) 11.50
NEMA Plug (208/240) L6-30P
Notes:
1. Each XLR8™ Arm comes with 6’ power cord, separate receptacle
needed for each unit.
2. For use on individual branch circuits only.
®
AccuTemp product may be covered by one or more US Patents. See www.accutempip.net
XLR8™ UPPER HEATED PLATEN
Electric Upper Heated Platen Arm
24 3
8"
(COOKING DEPTH)
20"
4 11
16 "
"
4
UNIT WIDTH
UNIT DEPTH
16
39 1"
24 1
23 7
8"
(COOKING WIDTH)
4
3"22 15
"
5
16
4 8"
3"
16
10
(COOKING HEIGHT)
"
4
3
24
13
31 1
2"
44 13
16 "
Drawing shown with (2) XLR8 Upper Heated Arms
Mounting bracket illustrated and required.
Available in 2’, 3’ or 4’.

MP5032-2104 XLR8 HEATED PLATEN 4
3. INSTALLATION
TOOLS REQUIRED:
Spirit Level
Phillips Screw Driver
Small Blade Straight Screw Driver
Digital Clamp Ammeter
Multimeter
Weighted Temperature Probe
Digital Temperature Meter
3.1 INSTALLATION NOTICE
Only qualified service technicians/electricians should perform the installation to ensure
that all electrical and safety requirements are met and that all wiring installations are
performed in accordance with all national, state and local codes.
Location Combustible
Construction
Non-Combustible
Construction
Back 2 Inches 0 inches
Right Side 1 Inch 0 inches
Left Side 1 inch 0 inches
Above
Arms
26 inches
(+height of
griddle)
26 inches (+height
of griddle)
SUITABLE FOR ALL INSTALLATION ON COMBUSTIBLE
FLOORS.
3.2 UNPACKING
This equipment was carefully inspected before
shipment from the factory. The transportation
company assumes full responsibility for safe
delivery to the customer until customer
acceptance of the package. Careful inspection
of the packaging and the equipment should
be completed before acceptance from the
transportation company.
3.3 XLR8 LIFTING
The equipment is heavy enough to require
additional manpower or powered assistance
when installing or moving.
When moving the equipment manually
make sure there are enough people for the task
as the equipment is heavy.
Make sure the equipment is not dropped
during moving. People doing the carrying
could be seriously injured and/or the
equipment damaged. The manufacturer does
not accept any responsibility for damage
resulted from such actions.
3.4 LOCATION AND PLACEMENT
The XLR8 electric equipment has been designed
to be mounted on an AccuTemp AccuSteam
griddle.
The operating temperature of the platen ranges
from 150°- 440°F (65.5°- 226°C). Since these
temperatures can also be found on surfaces
around the perimeter of this commercial
equipment, care should be given not to install
next to or against, objects or surfaces with a
low melting or flash point.
3.5 CLEARANCES
3.6 LEVELING
The equipment must be installed in a level
condition. An out-of-level condition will result in
an uneven compression of product and uneven
cooking.

MP5032-2104 XLR8 HEATED PLATEN 5
3.7 ELECTRICAL CONNECTIONS
3.7.1 ELECTRICAL SUPPLY
The electrical voltage requirement is
listed on the data plate that is located on the
lower left side panel.
Make sure the voltage is within 10% of
the voltage listed on the steamer data plate.
Connection to any other voltage not
identified on the data plate will cause damage
to the components and is not covered under
warranty.
Grounding provides a path for electric
current to reduce risk of shock.
If provided with one, the plug must be
plugged into a receptacle that is properly
installed and grounded in accordance with all
National, State and local electrical codes or in
the absence of local electrical codes with the
National Electric Code, ANSI/NFPA 70, or the
Canadian Code, CSA C22.2 as applicable.
Under no circumstances shall the plugs
grounding prong be cut or bent to fit a
receptacle other than the one specified.
Do not use any adapters.
Any in-field modification made that
bypass the safety features of this equipment
will result in serious injury or death.
Any in-field modifications made without
written authorization from AccuTemp
Products, Inc. will void all written and oral
warranties.
This commercial equipment must
be properly grounded in accordance of
all current National, state and local codes.
Never remove the ground prong of the plug.
The XLR8 has been designed, manufactured
and tested to meet or exceed the demanding
standards of safety set forth by ANSI/NFPA
70. To to ensure that this high level of
safety is maintained in your installation, it is
important that you read and understand the
following information before attempting to
use the equipment.
3.7.2 ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the
data plate located on the front right of the
control panel. All standard XLR8 are wired to
an internal power supply terminal and draw
power from the griddle.
If supplied with a 6ft (1.83m) cord and the
appropriate UL listed plug, the equipment
must be connected to the correct voltage
specified on the units data tag. Depending on
the rating listed on the data plate. Make sure
that the voltage at your supply receptacle
is within ± 10 % of the voltage listed on the
griddle data plate. Connection to any other
voltage may cause damage to components in
the commercial equipment. The equipment
plug must be used with the appropriate
receptacle.
3.7.3 GROUNDING INSTRUCTIONS
Grounding provides a path for electric
current to reduce the risk of shock. This
product is equipped with a power cord
having a grounding conductor and a
grounding plug. The plug must be plugged
into a grounded receptacle that is installed
and grounded in accordance with local
codes, or in the absence of local codes,
with the National Electric Code, NFPA 70, or
the Canadian Electrical Code, CSA22.2, as
applicable

MP5032-2104 XLR8 HEATED PLATEN 6
3.8 START UP PROCEDURE
1. Ensure both arms are square with the griddle.
Use the griddle sides as a reference.
2. If adjustment is needed, loosen the nuts that
hold the lift assembly to the base lift bracket.
3. Resecure the nuts once the arm assembly has
been squared.
3.8.1 (OPTIONAL UNLOCK PLATEN FLOAT
Should the customer wish it is possible to
unlock the platen:
1. Loosen the two #10-24 X 1” Truss head
cover mounting screws enough to lift the
controller cover up but don’t attempt to
remove the screws.
2. Lift o the controller cover and allow to
hang to one side.
3. Use a 5/16” wrench, socket wrench or
nut driver to loosen the four #6-32 nyloc
nuts retaining the float locks.
4. Remove completely or adjust the float
locks to achieve the desired amount of
float.
5. If the float locks are retained, tighten the
four #6-32 nyloc nuts retaining the float
locks to hold them in in the new position.
6. If the float locks are not retained, tighten
the four #6-32 nyloc nuts on the studs
to prevent them from coming loose or
remove the nuts and flat washers entirely.
7. Reinstall cover and tighten the cover
mounting screws.
TEST INSTALL
1. Plug in lift power cord to correct NEMA
receptacle.
2. Power the XLR8 on using control buttons
located on top of the arm.
3. Keep arm elevated an allow to heat to
temperature displayed on control digital
display.
4. Monitor temperature using a fluke wand
meter.
5. Once unit has reached temperature allow
15 minutes for it to stabilize, then take
three temperature readings from the
front, middle and back of the arm cooking
surface.
6. The temperatures should be with 5+/-F of
the temperature displayed.
3.8.1 INSTALL TEFLON SHEET
1. Raise the two teflon retaining handles o the
arm.
2. Secure one side of the teflon sheet using one
handle, keeping the handle at the central point
of the arm (“Figure 11”).
3. Stretch the teflon across the underside of the
platen and secure with the other retaining
handle.

MP5032-2104 XLR8 HEATED PLATEN 7
4. OPERATION
RISKS RESULTING FROM CONTACT WITH VERY HOT OBJECT:
HOT
Hot areas may form during the cooking process. Use protective gloves whenever handling hot
objects.
During the cooking process, do not handle cookware containing liquids or liquid foodstus
located above eye level. Danger of burns.
Be sure all operators read, understand and follow the information contained in this manual
including caution warnings, operating instructions and safety instructions.
Never use wet or damp gloves as moisture can conduct heat quickly.
Keep the floor in front of the equipment clean and dry. If spills occur, clean immediately to
avoid potential injuries.
Do not use abrasive (or steel) materials, such as wire brushes, metal scouring pads to clean
the teflon sheet surface.
4.1 VISUAL IDENTIFICATION
Fig 4.B
Lift Handle
Height adjustment
knob
Control Panel

MP5032-2104 XLR8 HEATED PLATEN 8
The equipment digital temperature control is easy to operate and requires little customer
interface. OPERATOR DISPLAY AND KEYPAD
ON/OFF
KEY
PROGRAM KEY
DOWN ARROW
LED 1
TIMER RESET KEY
ASTERISK KEY
LED 2
LED 3
PRESET TEMP KEY
PROGRAM KEY
UP ARROW
OPERATOR DISPLAY
4.2 CONTROL OVERVIEW
Fig 4.D
4.2.1 PROGRAM MODE
To enter Manager’s mode, turn the unit OFF by depressing then press and hold the KEY and
hold the key for minimum of 5 seconds. The control is now in Manager Program Mode the icon
will light, LED1 only, will blink, and the keypad will be reconfigured as shown in the following table:
In managers mode, the keypad will operate as follows:
Program # Program Description MIN Setting Max Setting Default
1 ON/OFF KEY ENABLED YES NO YES
2 PRESET TEMP 1 150 400 375
3 PRESET TEMP 2 150 400 350
4 PRESET TEMP 3 150 400 400
5 TIMER DEFAULT VALUE OFF 60:00 MINS 00:30S
Once parameters are set as desired, the control panel can be locked to prevent manipulation
without approval.
Toggle between programs Exit and save Increase displayed item
N/A Cancel will exit without
saving Decrease displayed item

MP5032-2104 XLR8 HEATED PLATEN 9
4.2.2 GENERAL OPERATION
1. Press the ON/OFF key to turn the unit on. The display will come on and show the current
temperature in the display.
2. To turn the unit o press and hold the ON/OFF key for about 5 seconds.
3. Temperature control features:
4. PRESET TEMPERATURES:
A. To change to a dierent PRESET temperature press the PRESET TEMP key to toggle to the
desired temp setting. (Default values are defined in Manager’s mode, parameters 1, 2 and 3).
The new selection will auto start after 3 seconds if no other key presses are made.
B. To change the temperature on the fly or change a pre-set temp value:
i. Press the PRESET TEMP key once to change on the fly to a desired operating temp or press
the PRESET TEMP key multiple times to toggle to a specific pre-set to change (Default values
are defined in Manager’s mode, parameters 1, 2 and 3. Factory default temps are 375°F, 350°F
and 400°F).
ii. Then press and hold the UP or DOWN keys for approximately 3 seconds, the LED indicator for
the selected pre-set will blink. (The LED’s indicate which preset is selected LED1=PRESET 1,
LED2 = PRESET 2, and LED3 = PRESET 3.)
iii. Then press the UP or DOWN KEYS to increase or decrease the cook temperature.
iv. To store the new set temperature into a Preset memory, press and hold the ASTERISK key
before the 3 seconds from the last key press are up.
5. Manual TImer Operation:
A. To start a timer sequence manually press the TIMER RESET key.
B. To stop a timer sequence before it runs out, press and hold the TIMER RESET key for about
three seconds.
C. To silence the timer after it runs out, press the TIMER RESET key or the ASTERISK key.
6. Auto-Start Timer Operation
A. To start a timer sequence lower the handle.
B. To stop a timer sequence before it runs out, press and hold the TIMER RESET key for about
three seconds.
C. To silence the timer after it runs out, lift the handle or press the TIMER RESET key or the
ASTERISK key.
7. To set up user lock out to prevent anyone from changing the temperatures or timer values
press and hold the UP ARROW key and the TIMER RESET key for 5 seconds while the controller
is OFF. This will Toggle USER LOCKOUT parameter between “LOCKED” and “UNLOCKED”.

MP5032-2104 XLR8 HEATED PLATEN 10
4.3.1 CLEAN AFTER INSTALLATION
It is recommended that you clean your XLR8
thoroughly before using it for the first time. To
clean the equipment teflon cooking surface, just
simply wash it down with a solution of mild soap
and water, then rinse thoroughly with clean water
and wipe dry with a clean towel.
4.3.2 PREHEATING
Press the ON/OFF and select the desired preset.
The upper platen should be approximately 40-
50°F hotter than the griddle surface to achieve
good caramelization on product.
The equipment will be preheated when the
selected set temperature is displayed and the
corresponding LED goes solid. Please use caution
as temperatures on and around the cooking
surface could cause severe burns.
4.3.3 ADJUSTING THE PLATEN GAP
HEIGHT
The XLR8 arm has gap adjustment every 1/32nd
of an inch. This gives you the control needed to
adjust to any product up to 2” thick. To adjust the
gap remove the adjustment arm in the front of
the Upper Heated Platen. Raise the arm and place
the desired product in the middle of the platen
coverage area. With the griddle and arm on and
preheated, lower the arm until you start to hear
a sizzle from the product. This means you are
applying slight pressure on the top of the product.
At this point, install the adjustment arm onto the
mounting plate. Place the lock bolt into the hole
that lines up with the mounting plate and tighten.
4.3.4 ALLOWING THE PLATEN TO FLOAT
The platen is shipped in its ‘locked’ setting, which
keeps the platen cooking surface horizontally level
and is designed for the cooking of level products
such as burgers.
Please use caution as temperatures
on and around the griddle cooking
surface could cause severe burns.
4.3 COOKING
If the product being cooked is uneven in
nature, such as chicken, the platen can be
unlocked, allowing it to float and enablish
the even cooking of uneven product.
To unlock the platen see section 3.8.2 in the
INSTALLATION chapter of this manual.
4.3.5 COOKING
If a recipe is provided for the product you
are preparing, always follow your company
guidelines for preparing product.
If adjusting your own recipe to incorporate
the use of the XLR8 it is recommended to
apply the following steps:
• Divide the total cook time applied to
a product cooking on just the griddle
surface by half. Adjust the time from
there until you are happy with the
finished product.
• Once you have the time and
temperature for the product identified,
use the programming instructions to set
the timer and presets accordingly.
• Adding more compression (smaller gap
between platen and griddle surface) will
decrease cook time but may result in a
dryer product.
4.3.6 CLEANING
• Power unit o and allow to cool until it is
safe to touch, approximately 30 minutes.
• Remove teflon sheetand clean using mild
soap and water solution and a towel.
• To clean the arm, once cooled, clean
using mild soap and water solution and a
towel. Rinse when done with clean water
and allow to dry overnight.
Do not Power Spray the griddle or XLR8
Upper Heated Platen. A non-Metallic
cleaning pad can be used to remove
large debris or built up areas.

MP5032-2104 XLR8 HEATED PLATEN 11
PM TASK DESCRIPTION Daily Biannual Yearly
Verify that the equipment is level and properly located under the
hood.
X X
Verify that the temperature controller is working properly and
that there are no rips in the label.
X X X
Check that the splash shield at the top of the control panel is
under the rail provided. If not water and or grease can migrate
into control panel.
X X
Inspect the control compartment for foreign particulate and any
loose wiring or connections.
X X
Check that the power supply cord is not frayed, outer covering
is not degraded or any bare cooper is visible. Replace if required.
X X X
Verify amp draw to listed amp requirements on the data tag of
the equipment.
X X
If on an AccuTemp Stand verify mounting fasteners are in place
and tight. If not correct. If the stand has casters check that
the wheels are intact and that they are mounted correctly. If
grease covered clean with a mild detergent and clean water.
Dry completely. Apply a food grade silicone to the locking
mechanism.
X X X
Complete a 3 point temperature test on the platen to check for
even temperature across the surface of the cooking surface.
X X
Check for grease buildup in the grease drawer container and
clean it with a damp towel saturated with a mild detergent and
clean water. Dry with a clean dry towel.
X X X
After all metallic areas are cool to the touch, clean external
metal surfaces except the cooking surface. With a damp clean
towel saturated with a mild detergent and clean water. Dry with
a clean dry towel.
X X X
5. PLANNED MAINTENANCE CHECKLIST
It is recommended that you contact your AccuTemp authorized service provider to setup a planned
maintenance program to keep your equipment operating in the most ecient manner. AccuTemp
recommends a minimum of a yearly schedule.

MP5032-2104 XLR8 HEATED PLATEN 12
SERVICE
1. SEQUENCE OF OPERATION
1. When power is connected to power line voltage is supplied to the three position
terminal block.
2. The white common lead from the terminal block is connected to the red “Y” harness
which one side supplies common to the power in J2-1 terminal of the circuit board.
The other side is daisy changed and connects to the common side of the heater
element harnesses.
3. The black wire from the terminal block supplies power to one side of the fuse.
4. The other side of the fuse is connected to a “Y” harness consisting of a black wire
connected to a high temp white wire.
5. Line voltage flows through the black wire of the “Y” harness and is connected to the
controller power in J2-2 terminal.
6. Line voltage is connected to the white high temp wire of the “Y” harness and connects
to position #1 (front) heater over temp thermostat.
7. Power flows through the front heater thermostat and to a white high temp wire which is
connected to position #2 (middle) heater over temp thermostat.
8. Power flows through the middle heater thermostat and to a white high temp wire which
is connected to position #3 (back) heater over temp thermostat.
9. Power flows through the back heater thermostat to a white high temp “Y” wire harness
which connects to the controller circuit board terminal J7-1 then daisy chained to J7-3
and to J7-5.
10. When the ON/OFF key is pressed to turn the unit ON, relays K1, K3 and K5 are turned
on allowing power to flow through to controller terminals J7-7, J7-4 and J7-6 then to
each heater.
11. Temperature sensing is done through three RTD sensors, front (#1) middle (#2) and
back (#3).
12. The front (#1) RTD is connected to the controller terminals J3-1 and J3-2.
13. The middle (#2) RTD is connected to the controller terminals J5-1 and J5-2.
14. The back (#3) RTD is connected to the controller terminals J4-1 and J4-2.
15. As the temperature rises and reaches the set point temperature the controller
disengages relays K1, K3 and K5 and begins to regulate temperature to the set point.
16. A timer start/stop circuit reed switch is connected to the controller terminals IN1-1 and
IN1-2.
17. When the arm is lowered a magnet engages the reed switch and closes the circuit to
the controller, starting the timer.
18. When the arm is raised beyond the magnet field the reed switch disengages and opens
the circuit to the controller, stopping the alarm or the timer if the timer is still running.
19. The timer can be disengaged from auto starting through the controller manager’s
mode.
20. Controller settings and options are covered in the operator’s manual.

MP5032-2104 XLR8 HEATED PLATEN 13
2. TROUBLESHOOT GUIDE
2.1 TROUBLESHOOT FLOWCHART
UNIT ON?
UNIT
PLUGGED IN?
BREAKER ON?
CORRECT
INTERNAL
VOLTAGE?
INTERNAL
FUSE INTACT?
HEAT ON?
ERROR
CODE? TIMER
ACTIVATES?
PRODUCT
UNDER
COOKED?
PRODUCT
OVER
COOKED?
CORRECT
TEMPERATURE?
YES
NO
YES
YES
YES
NO
NO
YES
YES
YES
NO
YES
NO
YES
CALL ACCUTEMP
SERVICE
8004800415?
REPLACE FUSE
A
B
RESET
NO
D
C
E
F
NO
NO
G
YES
NO
NO
WORKING TO
SPEC.

MP5032-2104 XLR8 HEATED PLATEN 14
2.2 TROUBLESHOOT GUIDE
AIncorrect voltage supplied
The unit is designed to work with 120V. Check that the original OEM plug is
still being used and there is no damage to the cord. Verify correct voltage at
receptacle.
BError code
If the display is showing Err, that is a sign the control board does not detect
a temperature sensor connection. Access the control board and inspect
the three RTD connections at J3, J4 & J5. If connections look good, test
resistance across the black and white wires for each RTD. Compare to the
table on page **
CUnit not calling for heat.
Check which preset has been selected on the digital control. There are three
LED lights on the control panel. Each corresponds to the call for heat to one
of three elements in the platen. When the unit is calling for heat, the lights
will flash. If the lights are steady, the control believes it has reached set point
and has stopped the call for heat.
If the lights are flashing, but the unit temp is not increasing:
1. Remove controller cover.
2. Disconnect the harness with a white and black wire that is attached to
the fuse.
3. Disconnect the black harness from terminal J2-2 and the white with
orange wire harness from terminal J7-1.
4. Ohm across the two white wires removed. If open then a lead wire
to the bimetal thermostats or a bimetal thermostat is opened. Let the
heaters cool then retest.
5. If still open, disassemble the heater box and test for the open bimetal
thermostat.
6. If closed then look for a broken connection or burnt wire in the red
harness. If the red harness and connections are good then replace the
controller.
If the lights are not flashing and unit temp does not increase:
1. Replace the controller. To have all three not flashing on warm up is not
a likely event. All three RTDs would have to be damaged to the set point
value which is highly unlikely.
DUnit not achieving set
temp
If the unit is heating but cycling at a lower/higher temp than set point:
1. Check unit presets are correct (see programming instructions on page 8).
2. When unit has reached cycle point, temp all three platen zones using a
direct contact thermometer with a small amount of cooking oil applied.
Verify if unit is reaching set temp within 10°F±.
3. If temp is not matching set point. Access unit control.
4. Remove white and black wires leading to one of three RTDs and take a
resistance reading across them. Compare to the table on page **.
5. If RTD reading matches current platen temp, replace control board.
6. If RTD reading is o of current platen temp, replace RTD. Continue to test
each RTD in turn.

MP5032-2104 XLR8 HEATED PLATEN 15
E
Timer does not activate
when Platen arm
depressed
1. Manually depress ‘Timer’ button on control. If timer starts, refer to section
4.2.1 to reprogram to automatically start the timer.
2. Access the control panel interior and disconnect the magnetic proximity
switch from the board. Set up a multimeter to test for resistance across
the two wires leading to the proximity switch.
3. Test if the proximity switch closes when the arm is lowered. If the switch
does not close, replace the switch.
4. If the switch does close and the timer cannot be activated manually,
replace the control board.
FProduct undercooked
1. Adjust cooking time.
2. Adjust cooking temperature
3. Adjust platen height higher or lower.
GProduct overcooked

MP5032-2104 XLR8 HEATED PLATEN 16
3.0 REMOVAL AND REPLACEMENT OF PARTS
3.1 CONTROL BOARD
1. Power unit down and unplug from receptacle.
2. Low platen assembly so it is level with the griddle and secure it to griddle.
3. Access control interior by loosening two truss head screws, one at front of control box and one
at rear (Item 18, Circled in , .)
4. Carefully lift the control box cover up, do not stretch the wires attached the the underside of
the cover.
Unless otherwise specified,
Dimensions: Inches
Bends: 90
Tolerances:
Angular
1°
2 Place Decimal
.02
3 Place Decimal
.005
T.I.R
.005
√125 Micro Inches
GD&T Per ANSI Y14.5M
INDICATED EDGES
MUST BE SOFTENED:
* = NEAR SIDE
*
= FAR SIDE
*
= BOTH SIDES
5
61
7
9
4
10
12
16
2
1
2
3
15
4
12
13
3
DEV002214-1
3.
?
18
20
21
17
FRONT
12
LABEL AS #3
12
LABEL AS #2
12
LABEL AS #1
22
22
22
LABEL TERMINAL
END AS #2
LABEL TERMINAL
END AS #4
LABEL TERMINAL
END AS #6
23
23
23
LABEL TERMINAL
END AS #1
LABEL TERMINAL
END AS #3
LABEL TERMINAL
END AS #5
NOTES:
1
TORQUE HEX NUT, ITEM
7
TO 37+/-3 IN-LBS, STARTING IN THE CENTER
AND WORKING FIRST TO THE SIDES AND THEN TO THE ENDS. TIGHTEN
TWICE IN THIS MANNER.
2
APPLY THERMAL JOINT COMPOUND, ITEM
14
ONTO HEATER ITEM
2,
USING PASTE APPLICATION STENCIL (#NPT-FIX-TEMP-00046).
3
APPLY THERMAL JOINT COMPOUND, ITEM
14
ONTO THE BOTTOM OF
OVERTEMP, ITEM
10
COMPLETELY AND EVENLY COVERING THE BOTTOM.
4
APPLY THREAD LOCKER, ITEM
15
ON THREADS.
ECN
REV
DESCRIPTION
DATE
APPR
REVISIONS
-01
RELEASED TO PROTOTYPE
08-25-2020
RRR
DEV002214-1
PART NUMBER
Revision
ITEM
DESCRIPTION
3
AT0E-2699-3
E+ 23
TERMINAL, QDISC, INSULATED FEM - 14-16AWG .250 X .032 TAB
3
AT0E-2684-2
A02
22
QD TERMINAL MALE INSULATED 14-16 AWG .250 x .032 TAB
4
AT0F-1052-23000
G07
21
WASHER #6 TYPE B PLAIN
4
DEV002324-1
-01
20
PLATE, LOCK, PLATEN
2
AT0F-2691-41001
D01
19
NUT, #10-24 NYLOC
2
AT0F-1046-41060
-+
18
#10-24 X 3/4 TRUSS HEAD
4
AT0F-2691-21001
D01
17
NUT, #6-32 NYLOC
2
AT2I-6065-1
-04
16
INSULATION, UPPER PLATEN
8
AT0F-1046-31030
A01+ 15
SCREW, #8-32 x 3/8 PHLP TRUSS HEAD
AR
AT0H-3412-1
B
14
THERMAL JOINT COMPOUND
2
AT2I-5787-1
-04
13
INSULATION, UPPER PLATEN
1
DEV002245-8
-01
12
HARNESS ASSY, XLR8
3
AT0E-6033-1
-06
12
SENSOR, REPLACEABLE RTD
6
AT0F-2755-21030
D01
10
SCREW, #6-32UNC x 3/8 PHILIPS ROUND HEAD MACHINE
6
AT0F-2666-21000
B01
9
WASHER, SS #6 EXTERNAL TOOTH LOCK
AR
AT0H-3065-4
B02
8
THREAD LOCKER 272
18
AT0F-3401-1
-
7
NUT, SPECIAL LOCKING 1/4-20UNC-2B
18
AT0F-1052-51000
G07
6
WASHER 1/4 TYPE B PLAIN STAINLESS STEEL
18
AT0F-2663-4
B02
5
WASHER, Ø.687 OD BELLEVILLE
3
AT1E-2653-5
H+
4
OVERTEMP SWITCH
1
DEV002215-1
-01
3
COVER ASSY, HEATER
3
AT0E-4649-2
-01
2
HEATER. IN-CAST
1
DEV002211-1
-01
1
PLATE ASSEMBLY, HEATER
F
G
J
B
Friday, November 20, 2020 7:24:28 AM
11 5 39 27
D
12 10 8 6 4 1
4681012 7 29 3511
A
C
E
H
KK
H
E
C
A
D
B
J
G
F
-02
HEATER ASSEMBLY
RRR
11/10/20
N/A
11/10/20
Comments:
Material:
Finish:
N/A
Do Not Scale Drawing
Proj. Engr.
GLS
GLS
Checked
Drawn
08/25/20
Date
Name
AccuTemp Products, Inc.
8415 N. Clinton Park
Fort Wayne, IN 46825
DEV002214
Size:
Drawing No.:
Rev:
Title:
D
Sheet 1 of 1
Scale: 1:3
ECN:
5. Turn the control box cover over to access the control board cover.
6. Remove the 2 nuts securing the control board cover, top left and bottom right.
7. Slide the control board cover up and away.
8. Remove wires from the control board, taking note of there original location.
9. Remove control board.
10. Replace with new part and reassemble in reverse order.
11. Ensure control programming is set according to customer wishes

MP5032-2104 XLR8 HEATED PLATEN 17
3.2 RTD SENSOR
1. Follow typical safety protocol for electrical and work
space and tools. Lock out tag out.
2. Disconnect from power source.
3. Lower handle assembly.
4. Remove the controller cover
5. Remove the inner controller cover
6. Disconnect RTD terminals from Control board and
snip any wire ties that are binding the RTD wires
together.
7. Loosely install controller cover assembly.
8. With one hand on the handle to prevent the arm
assembly from rapidly lifting up, remove the heater
cover 8-32 X 3/8” Truss head screws doing the ends
first then finish in the center of the heater cover.
9. Slowly raise the arm assembly to its max height,
leaving the lower half of the heater assembly laying
on the griddle surface.
10. Carefully move the insulation away from around the
oending RTD to gain clearance to the threaded end
of the RTD sensor.
11. Use a 3/8” wrench to back out the RTD.
12. Reverse procedure to reinstall.
13. Use permanent lock-tite on the #8-32 heater cover
screws when reinstalling.

MP5032-2104 XLR8 HEATED PLATEN 18
3.3 OVERTEMP SWITCH
1. Follow typical safety protocol for electrical and work
space and tools. Lock out tag out.
2. Disconnect from power source.
3. Lower handle assembly.
4. Remove the controller cover
5. Loosely install controller cover assembly.
6. With one hand on the handle to prevent the arm
assembly from rapidly lifting up, remove the heater
cover 8-32 X 3/8” Truss head screws doing the ends
first then finish in the center of the heater cover.
7. Slowly raise the arm assembly to its max height,
leaving the lower half of the heater assembly laying
on the griddle surface.
8. Carefully move the insulation away from around the
oending Overtemp switch to gain clearance to the
threaded end of the Overtemp switch.
9. Use a 3/8” wrench to back out the switch.
10. Apply a small amount of thermal compound to the
bottom of the overtemp switch where it will make
contact with the element.
11. Reverse procedure to reinstall.
12. Use permanent lock-tite on the #8-32 heater cover
screws when reinstalling.
3.4 MAGNETIC PROXIMITY SWITCH
1. Follow typical safety protocol for electrical and work
space and tools. Lock out tag out.
2. Disconnect from power source.
1. Follow typical safety protocol for electrical and work
space and tools. Lock out tag out.
2. Power unit down and unplug from receptacle.
3. Access control interior by removing two screws, one at
front of control box and one at rear.
4. Carefully lift the control box cover up, do not stretch the
wires attached the the underside of the cover.
5. Disconnect proximity switch wires from control board,
marking their location.
6. Remove two nuts holding proximity switch in place.
7. Thread wiring out through arm assembly to complete
removal of switch.
8. Reinstall in reverse order.

MP5032-2104 XLR8 HEATED PLATEN 19
3.5 CAST ELEMENT ELEMENT
1. Follow typical safety protocol for electrical and work space and tools. Lock out tag out.
2. Disconnect from power source.
3. Lower handle assembly.
4. Remove the controller cover
5. Disconnect Element wires from Control board and snip any wire ties that are binding the wires
together.
6. Loosely install controller cover assembly.
7. With one hand on the handle to prevent the arm assembly from rapidly lifting up, remove the
element cover 8-32 X 3/8” Truss head screws doing the ends first then finish in the center of
the element cover.
8. Slowly raise the arm assembly to its max height, leaving the lower half of the element assembly
laying on the griddle surface.
9. Carefully move the insulation away from the element.
10. Use a 1/4” socket wrench to remove the 6 nuts holding the element in place and lift the
element out.
11. Lay the replacement cast element on a table with the smooth shiny side up. Wipe the surface
clean and apply 1.5 - 2.0 ounces of heat transfer compound to the smooth side of the casting
using a putty knife.
12. Use the putty knife to spread the thermal compound across the entire surface of the cast
element.
13. When the surface is covered, hold the fine tooth comb (included with the kit) vertical and
draw it along the length of the element in several passes to obtain an even, uniform thickness
coating across the entire surface. After each pass, remove excess compound with the putty
knife. When finished it should look like an even surface containing fine lines of the compound.
If the lines of compound do not cover, add additional compound in those areas and repeat.
14. Set the element in place on the platen with the heat transfer paste in contact with the platen
bottom. Refer to drawing DEV002214-1 in the parts section of manual for orientation
guidance. Try not to get paste on the studs when putting the element in place. Center the
holes in the casting on the studs.
15. Place the large fender washers over the center studs.
16. Place a spring washer over each stud. Spring washers are conical shapedwashers that flatten
out as the nuts are tightened against them. The springwashers should point up like a miniature
volcano.
17. Install new nuts on the studs and hand tighten. Use an inch pound torquewrench and tighten
each nut to 37 inch pounds starting in the center, working first to the sides and then to the end.
Tighten twice in this manner. Do not over-tighten the nuts.
18. Reinstall overtemp switch on new element following instructions in 3.3.
19. Reverse procedure from step 7 to complete repair.
20.Use permanent lock-tite on the #8-32 element cover screws when reinstalling.
This manual suits for next models
1
Table of contents