OPERATING AND INSTALLATION INSTRUCTIONS FOR THE INS-ZSACC STANDALONE CODE
LOCK PLUS CARD AND KEY FOB READER
INS-ZS-ACC combines two autonomous devices INS-ZS and
INS-ACC in one panel. It is a microprocessor-based device that
integrates the features of a code lock and a proximity element
reader used to control one or more outputs. The exit can be
activated by using the right code or a proximity key fob/card
assigned to relevant output. The devices can be configured as
needed to work together to control a common output, it can also
be configured separately for up to four independent outputs. It
can directly control external devices such as an E-lock, reversible
E-lock (output 1 only) or an optional relay which can be used to
control any other device such as a magnetic e-lock, a barrier, etc.
1. INSTALLATION
The INS-ZSACC box is flush mounted. Lead the wires through hole 1. Fix the box with expansion
bolts through holes 2, when installing in soft materials, such polystyrene, fix the box using mounting
foam or plaster. Screw in the enclosure with 4 screws, using a size 3 Allen key.
The device can also be surface-mounted using a surface-mounted box to be purchased
separately (trade designation: INS-P-XS NT (INS-ZSACC)). Fix the surface-mounted box to the wall
with expansion bolts through four holes 2. Lead the wires through hole 1. Screw in the enclosure with
4 screws, using a size 3 Allen key.