BRK electronic C0250B User manual

CARBON
ALARM
MONOXIDE
CAT. C0250B/CO250LB
10YR CO SENSOR
10YR ALARM LIFE
ELECTROCHEMICAL
CO SENSOR
Most accurate technology available for
detecting carbon monoxide as com-
pared to other sensing technologies
TWO SILENCE
FEATURES
Silences low battery chirp for up to
eight hours or silence nuisance alarm
for several minutes.
END OF LIFE SIGNAL
Provides audible notice when alarm
needs to be replaced after 10 years.
TAMPER RESISTANT
LOCKING PIN
Locks alarm cover to prevent removal
of battery. Perfect for apartment,
dormitory or hotel applications.
9V BATTERY
INCLUDED
Available in the following versions:
CO250B Alkaline Battery
CO250LB 5 Year Lithium Battery
Description:
BRK Model CO250 is a single station carbon monoxide alarm specifically designed
for residential and institutional applications including sleeping rooms of hospitals,
hotels, motels, dormitories, and other multifamily dwellings as defined in standard
NFPA 101. Model CO250 has been fully tested and complies with, UL2034, NFPA
720, and NFPA 101 and other agencies that model their codes after the above
agencies. It meets building codes where battery operated carbon monoxide alarms
with silence are required.
BRK Model CO250 is a state of the art carbon monoxide alarm designed to provide
early warning of the presence of carbon monoxide. It features an electrochemi-
cal carbon monoxide sensor, an 85dB horn, a full function test switch and a red
LED light that indicates DC power or alarm. The CO250B features a 9V alkaline
battery and the CO250LB a 9V 5 year lithium battery. This alarm has two silence
features. Low Battery Silence: Temporarily silence the low battery chirp for up to
eight hours. Alarm Silence: Silence alarm for several minutes. It also features a
tamper resistant locking pin that locks alarm cover to prevent removal of battery.
Perfect for apartment, dormitory or hotel applications. The compact, low profile de-
sign complements any décor. Battery installation and removal can occur while the
unit is mounted to the ceiling or wall via the hinged cover. When voltage drops to
a pre-set warning level, the horn will “chirp” approximately once per minute to in-
dicate a fresh battery is needed. To insure the battery is always replaced properly,
the cover is designed to resist closing when
the battery is missing. Designed
for wall or ceiling mount-
ing. Includes mount-
ing anchors and
screws.
9V Battery Powered
CO
CAT. CO250B/CO250LB
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The carbon monoxide alarm shall be a BRK Model CO250 and shall provide at a
minimum the following features and functions:
1. An electrochemical CO sensor.
2. The unit shall be capable of self restoring.
3. The unit shall have an “End of Life” signal after 10 years (120 months) of operation.
This signal should be capable of temporarily being silenced for up to 2 days. After
about 2 days, the signal will resume. After about 2-3 weeks the signal cannot be
silenced.
4. Powered by a supervised 9V battery and a solid state piezo horn rated at 85dB at
10 ft.
5. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
6. A test/silence button to check all alarm functions and to silence any nuisance
alarms. In addition, the unit shall have a low battery silence feature to quiet
the low battery chirp for up to eight hours.
7. A tamper resistant locking pin should be provided that locks alarm cover to prevent
removal of battery.
8. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the
following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10
and 50 minutes and 70 PPM CO between 60 and 240 minutes.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
10. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
11. The unit shall at a minimum meet the requirements of UL2034, NFPA 720, NFPA
101, ICC.
Alarm Dimensions: 1.6”H x 4.25”Dia
Weight: 5.1 oz
Operating Voltage: 9V Battery Powered
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates carbon monoxide condition,
causing the unit to alarm. Press and hold test/silence
button
Alarm Reset: Automatic when CO clears
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red LED
Local Alarm: Audio alarm and rapidly flashing Red LED
End of Life: Replace alarm 120 months after installation
Listing: Listed to UL2034 Standard
Individual Carton Dimensions 4.38 ”L x 1.75”W x 4.38”H
Weight 0.39 lbs.
Cube 0.02 ft3
UPC 0 29054 00392 8: CO250B
0 29054 00725 4: CO250LB
Master Carton Dimensions 12.63”L x 6.13”W x 5.19”H
Master Pack 6
Weight 3.2 lbs.
Cube: 0.15 ft3
I2of5: 600 29054 00392 0: CO250B
600 29054 00725 6: CO250LB
Pallet Information
Cases per Layer 36
Number of Layers: 9
Cases per Pallet: 324
Units per Pallet: 1,944
Cube: 55.0 ft3
Weight: 1,107 lbs.
©2015 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3171
brkelectronics.com
Installation of this CO alarm must conform to NFPA 720. Always check your local building
codes. Follow all instructions for placement as outlined in the user’s manual in sections
titled “Recommended Locations for CO Alarms” and “Locations to Avoid for CO Alarms”.
THE PARTS OF THIS CO ALARM
1. “Open Here”
2. “No Battery” tab
3. Test/Silence button tab
4. CO alarm base
5. Standard screw mounting slots
6. Install 9V battery here
7. Locking pin slot
8. Locking pin: Remove and
insert in 7
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
CO
1
2
3
4
5
7
6
8
7
CARBON
ALARM
MONOXIDE
CAT. C0250B/CO250LB
10YR CO SENSOR
10YR ALARM LIFE
ELECTROCHEMICAL
CO SENSOR
Most accurate technology available for
detecting carbon monoxide as com-
pared to other sensing technologies
TWO SILENCE
FEATURES
Silences low battery chirp for up to
eight hours or silence nuisance alarm
for several minutes.
END OF LIFE SIGNAL
Provides audible notice when alarm
needs to be replaced after 10 years.
TAMPER RESISTANT
LOCKING PIN
Locks alarm cover to prevent removal
of battery. Perfect for apartment,
dormitory or hotel applications.
9V BATTERY
INCLUDED
Available in the following versions:
CO250B Alkaline Battery
CO250LB 5 Year Lithium Battery
Description:
BRK Model CO250 is a single station carbon monoxide alarm specifically designed
for residential and institutional applications including sleeping rooms of hospitals,
hotels, motels, dormitories, and other multifamily dwellings as defined in standard
NFPA 101. Model CO250 has been fully tested and complies with, UL2034, NFPA
720, and NFPA 101 and other agencies that model their codes after the above
agencies. It meets building codes where battery operated carbon monoxide alarms
with silence are required.
BRK Model CO250 is a state of the art carbon monoxide alarm designed to provide
early warning of the presence of carbon monoxide. It features an electrochemi-
cal carbon monoxide sensor, an 85dB horn, a full function test switch and a red
LED light that indicates DC power or alarm. The CO250B features a 9V alkaline
battery and the CO250LB a 9V 5 year lithium battery. This alarm has two silence
features. Low Battery Silence: Temporarily silence the low battery chirp for up to
eight hours. Alarm Silence: Silence alarm for several minutes. It also features a
tamper resistant locking pin that locks alarm cover to prevent removal of battery.
Perfect for apartment, dormitory or hotel applications. The compact, low profile de-
sign complements any décor. Battery installation and removal can occur while the
unit is mounted to the ceiling or wall via the hinged cover. When voltage drops to
a pre-set warning level, the horn will “chirp” approximately once per minute to in-
dicate a fresh battery is needed. To insure the battery is always replaced properly,
the cover is designed to resist closing when
the battery is missing. Designed
for wall or ceiling mount-
ing. Includes mount-
ing anchors and
screws.
9V Battery Powered
CO
CAT. CO250B/CO250LB
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The carbon monoxide alarm shall be a BRK Model CO250 and shall provide at a
minimum the following features and functions:
1. An electrochemical CO sensor.
2. The unit shall be capable of self restoring.
3. The unit shall have an “End of Life” signal after 10 years (120 months) of operation.
This signal should be capable of temporarily being silenced for up to 2 days. After
about 2 days, the signal will resume. After about 2-3 weeks the signal cannot be
silenced.
4. Powered by a supervised 9V battery and a solid state piezo horn rated at 85dB at
10 ft.
5. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
6. A test/silence button to check all alarm functions and to silence any nuisance
alarms. In addition, the unit shall have a low battery silence feature to quiet
the low battery chirp for up to eight hours.
7. A tamper resistant locking pin should be provided that locks alarm cover to prevent
removal of battery.
8. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the
following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10
and 50 minutes and 70 PPM CO between 60 and 240 minutes.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
10. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
11. The unit shall at a minimum meet the requirements of UL2034, NFPA 720, NFPA
101, ICC.
Alarm Dimensions: 1.6”H x 4.25”Dia
Weight: 5.1 oz
Operating Voltage: 9V Battery Powered
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates carbon monoxide condition,
causing the unit to alarm. Press and hold test/silence
button
Alarm Reset: Automatic when CO clears
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red LED
Local Alarm: Audio alarm and rapidly flashing Red LED
End of Life: Replace alarm 120 months after installation
Listing: Listed to UL2034 Standard
Individual Carton Dimensions 4.38 ”L x 1.75”W x 4.38”H
Weight 0.39 lbs.
Cube 0.02 ft3
UPC 0 29054 00392 8: CO250B
0 29054 00725 4: CO250LB
Master Carton Dimensions 12.63”L x 6.13”W x 5.19”H
Master Pack 6
Weight 3.2 lbs.
Cube: 0.15 ft3
I2of5: 600 29054 00392 0: CO250B
600 29054 00725 6: CO250LB
Pallet Information
Cases per Layer 36
Number of Layers: 9
Cases per Pallet: 324
Units per Pallet: 1,944
Cube: 55.0 ft3
Weight: 1,107 lbs.
©2015 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3171
brkelectronics.com
Installation of this CO alarm must conform to NFPA 720. Always check your local building
codes. Follow all instructions for placement as outlined in the user’s manual in sections
titled “Recommended Locations for CO Alarms” and “Locations to Avoid for CO Alarms”.
THE PARTS OF THIS CO ALARM
1. “Open Here”
2. “No Battery” tab
3. Test/Silence button tab
4. CO alarm base
5. Standard screw mounting slots
6. Install 9V battery here
7. Locking pin slot
8. Locking pin: Remove and
insert in 7
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
CO
1
2
3
4
5
7
6
8
7

This manual suits for next models

1

Other BRK electronic Security System manuals

BRK electronic First Alert SC9120LBLA User manual

BRK electronic

BRK electronic First Alert SC9120LBLA User manual

BRK electronic First Alert SC9120BA User manual

BRK electronic

BRK electronic First Alert SC9120BA User manual

BRK electronic PC910VB User manual

BRK electronic

BRK electronic PC910VB User manual

BRK electronic MPG120 User manual

BRK electronic

BRK electronic MPG120 User manual

BRK electronic D702MC User manual

BRK electronic

BRK electronic D702MC User manual

BRK electronic CO910V User manual

BRK electronic

BRK electronic CO910V User manual

BRK electronic 7030BSL User manual

BRK electronic

BRK electronic 7030BSL User manual

Popular Security System manuals by other brands

Secure Care KinderGUARD ID installation manual

Secure Care

Secure Care KinderGUARD ID installation manual

Nortek Security & Control Numera 2GIG-WMT1-345 installation instructions

Nortek Security & Control

Nortek Security & Control Numera 2GIG-WMT1-345 installation instructions

Velleman CCTVPROM11 Quick installation guide

Velleman

Velleman CCTVPROM11 Quick installation guide

Carmanah R247-E user manual

Carmanah

Carmanah R247-E user manual

Datatool DT201 operating instructions

Datatool

Datatool DT201 operating instructions

Security Labs SLM443 quick start guide

Security Labs

Security Labs SLM443 quick start guide

Carmanah R820 owner's manual

Carmanah

Carmanah R820 owner's manual

Belkin F8E500 installation instructions

Belkin

Belkin F8E500 installation instructions

Pudu GW1 user manual

Pudu

Pudu GW1 user manual

Honeywell Galaxy Keyprox Installation and programming instructions

Honeywell

Honeywell Galaxy Keyprox Installation and programming instructions

Siemens HMS-S installation instructions

Siemens

Siemens HMS-S installation instructions

RTK 725 Series manual

RTK

RTK 725 Series manual

Heathkit Heathkit GD-1183 Operation manual

Heathkit

Heathkit Heathkit GD-1183 Operation manual

Labkotec idOil-20 quick guide

Labkotec

Labkotec idOil-20 quick guide

Barnett Engineering ProTalk Cv3 installation instructions

Barnett Engineering

Barnett Engineering ProTalk Cv3 installation instructions

Code 3 Pursuit Siren Installation and operation instructions

Code 3

Code 3 Pursuit Siren Installation and operation instructions

Whelen Engineering Company B6LED Series installation guide

Whelen Engineering Company

Whelen Engineering Company B6LED Series installation guide

Kidde 900-CUAR manual

Kidde

Kidde 900-CUAR manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.