WARNING
Read the following information to avoid possible exposure to microwave radiation:
The basic design of the Microwave Oven makes it an inherently safe device to both use and service.
However,therearesomeprecautionswhichshouldbefollowedwhenservicingthemicrowavetomaintainthis
safety. Theseareasfollows:
1.
Always operate the unit from an adequately
groundedoutlet. Do notoperateonatwo-wire
extension cord.
2.
Beforeservicingtheunit(ifunitisoperable)perform
the microwave leakage test.
3.
Theovenshouldneverbeoperatedifthedoordoes
notfitproperlyagainsttheseal,thehingesorhinge
bearings are damaged or broken; the choke is
damaged, (pieces missing, etc.); or any other
visible damage can be noted. Check the choke
areatoensurethatthisareaiscleanandfreeofall
foreign matter.
4.
If the oven operates with the door open and
producesmicrowaveenergy,takethefollowing
steps:
A.
Telltheusernottooperatetheoven.
B.
Contact ACP ComServ immediately.
5.
Alwayshavetheovendisconnectedwhentheouter
case is removed except when making the "live"
tests called for in the Service Manual. Do not
reach into the equipment area while the unit is
energized. Makeallconnectionsforthetestand
checkthemfortightnessbeforepluggingthecord
into the outlet.
6.
Alwaysgroundthecapacitorsonthemagnetron
filter box with an insulated-handle screwdriver
before working in the high voltage area of the
equipmentcompartment. Sometypesoffailures
will leave a charge in these capacitors and the
dischargecouldcauseareflexactionwhichcould
makeyouinjureyourself.
7.
Always remember that in the area of the
transformer there is HIGH VOLTAGE. When the
unitisoperatingkeepthisareaclearandfreeof
anythingwhichcouldpossiblycauseanarcor
ground,etc.
8.
Do not for any reason defeat the
interlock switchesthereisnotvalidreason
forthisaction atanytime;norwillitbe
condonedbyACP.
9.
IMPORTANT: Before returning a unit to a
customer,besuretocheckforproperswitch
interlock action.
10.
The MicrowaveOvenshouldneverbe
operatedwithanycomponentsremovedand/or
bypassedorwhenanyofthesafetyinterlocksare
found to be defective, or when any of the seal
surfacesaredefective,missing,ordamaged.
11.
All microwaveovensmeetallrequirements
oftheradiationcontrolforHealthandSafetyActof
1968. Due to measurement uncertainties, the
maximumleakageforthefieldwillbe4mw/cm2.
12.
Toensure that the unit does not emit excessive
microwaveleakageandtomeettheDepartment
ofHealthandHumanServicesguidelines,check
theovenformicrowaveleakageusingamicrowave
oven leakage meter that complies with US
GovernmentCDRH/FDA/DHHSrequirements
andoranyotherlocalgovernmentrequirements.
Themaximumleakagelevelallowed by ACP
is4mw/cm
2.
13.
Ifservicerencountersanemissionreadingover
4mw/cm2,theserviceristoceaserepairand
contact the ACP ComServ Department
immediatelyforfurtherdirection.ACP
will contact the proper Government
Agencyuponverificationofthetestresults.