ACS A1040 MIRA User manual

A1040 MIRA 3D
Operation manual
Acoustic Control Systems – ACS Group
Saarbrücken, Germany 2021
This instruction manual contains essential information on how to use this ACS product safely and effectively.
Before using this product, thoroughly review this instruction manual. Use the product as instructed.
Revision 1.0.6
Ultrasonic low-frequency tomograph

2
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
1. Cover Page Back 4
2. Cover Page Front 5
3. Important basic information 6
4. Abbreviations 8
5. Lables, position and content 9
6. Scope of Delivery 11
7. Main Components 13
8. Keys and system LEDs 17
9. Rechagreable Battery of the Main Device 20
10. Rechargeable Battery of the Control Unit 23
11. Device usage and Limitations 26
12. Safety 28
13. Maintenance and Repair 30
14. Technical Specification 33
15. Operation 34
16. Trouble shooting 37
17. CE Certificate 41
18. B-Scan 42
18.1 Main parameters .......................................................................................................... 42
18.2 Display parameters ...................................................................................................... 43
18.3 File manager ................................................................................................................. 45
19. MAP 47
19.1 Main parameters .......................................................................................................... 47
19.2 Display parameters ...................................................................................................... 48
19.3 File manager ................................................................................................................. 48
19.4 MAP manager ............................................................................................................... 48
20. C-Det 50

3
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
21. A-Scan 52
22. Setup 55
22.1 Instrument configuration ............................................................................................ 57
22.2 Automatic transducer testing ..................................................................................... 59
23. Getting started 63
23.1 App installation ............................................................................................................ 63
23.2 App activation .............................................................................................................. 64
23.3 Preparation for work ................................................................................................... 66
23.4 Update .......................................................................................................................... 67
0
Index

4
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Cover Page Back
Cover Page Back
1 Cover Page Back
Service Address: ACS-Solutions GmbH
Science Park 2
66123 Saarbrücken
Germany
Phone: +49 (0) 681 9659 2270
Fax: 49 (0) 681 9659 2280
E-Mail: info@acs-international.com
Web: acs-international.com

5
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Cover Page Front
Cover Page Front
2 Cover Page Front
A1040 Mira 3D
ULTRASONIC LOW-FREQUENCY TOMOGRAPH
User Manual
This manual contains important information about the correct and safe use of the
device.
Read this manual carefully before using the device for the first time and use the
device only in the intended manner.
Always keep this manual in the vicinity of the device.
Revision: 1
Issued: November, 18 th 2020
Make sure the manual on hand corresponds with the
currently installed firmware and control software release on your system.
Check the firmware and control software release that is currently installed on your
system (for further information see chapter "Setup")
Withevery firmware and control software update the functionality of the device will
change. It is possible that formerly described functions are not available any more, new
functions are added or pictograms and/or procedures change. These changes will be
documented in the latest, online available manual.
Check page for available manuals and software updates.
55
67

6
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Important basic information
Important basic information
3 Important basic information
Read this manual carefully before using the device to ensure safe and proper use.
Intended use:
The A1040 MIRA3D device is intended for the ultrasonic inspection of constructions made of
concrete, reinforced concrete and stone with one-sided access. The design is for manual operation.
For positioning purposes, the device is equipped with 4 positioning Laser-LEDs class 2M.
Never Use the device for any other purposes than stated above.
Never use the device on humans or animals. Never look into the Lasers. For further Safety
instructions see chapter Safety
The A1040 MIRA3D device must be connected via hotspot to a Control Unit. Only use Control Units
approved by ACS for this purposes.
A1040 Mira 3D is normally equipped with a tablet
device as Control Unit that is seated in a specially developed housing. The Control
Units provided by ACS are selected to guarantee a save and reliable operation of the
all over system. Please do not try to open the provided Housing for the control unit.
If the control Unit is damaged or malfunctioning, please contact your ACS support.
Do not try to control the A1040 Mira 3D with other
mobile devices that are not specified and provided by ACS, even if the connectivity
and capability of executing the control software seems given. This may result in
unexpected behavior, personal injury, and / or equipment damage including
impairment of safety. ACS is not liable for any damage or loss (whether
contractually or unauthorized, including negligence) caused by not following this
warning.
This A1040 Mira 3D is CE-certified according to 2014/30/EU (EMC).
Liquid ingress protection and solid particle protection of the casing is in conformity with level IP53
(standard EN 60529), so the equipment is splash proof and protected against dust.
Despite the IP classification, it is possible that the device will be damaged in certain situations.
Follow the instructions below to maintain water resistance and dust protection.
·
Never immerse the equipment into water.
·
After contact with clear water, wipe it thoroughly with a clean soft cloth.
·
Contact of the device with liquids other than water may adversely affect the performance and
appearance of the device.
·
Dropping the device may affect the device protection.
·
The device should never be opened by untrained personnel.
Safety symbols used in this Manual:
Symbol
Description

7
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Important basic information
Important basic information
Indicates a potential threat.
Failure to avoid it can result
in death or serious injury.
Indicates a potential threat.
Failure to avoid it may result
in minor injury.
Indicates a potentially
harmful situation. If it is not
avoided, the device or
something in its vicinity may
be damaged.

8
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Abbreviations
Abbreviations
4 Abbreviations
Geben Sie hier den Text ein.

9
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Lables, position and content
Lables, position and content
5 Lables, position and content
Labels are safety related and must be present at all time when the device is in use.
Labels are positioned according the Figures ?,? below.
Figure 1: Position device identification Sticker
Figure 2: Position Laser class 2MSticker
Description
Content
device identification Sticker
Device Name: A1040 MIRA 3D
Manufacturer: Acoustic Control Systems-ACS
Group
Manufacturer Homepage Address: ACS-
Interantiona.com
Country of origin: Made in Germany

10
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Lables, position and content
Lables, position and content
CE: Conformity declaration for applicable European
Directives
FCC: Conformity declaration for requirements of
the Federal Communications Commission (FCC) -
relevant for delivery, sales and import to USA.
Sign or "Read manual first"
WEEE symbol that the product contains
batteries. These must be collected and disposed of
separately according the regional laws.
S/N: Serial number of the Device beginning with
120 followed by 5 digits.
Laser class 2 M
Warning sign placed on the exiting points of all 4
Laser-Diodes. Please see chapter "Safety" for
further Detail

11
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Scope of Delivery
Scope of Delivery
6 Scope of Delivery
Number
Part description
1
A1040 Mira 3D device
2
Mobile control device
3
Electric socket adapters
4*
Charging devices for A1040 Mira 3D and moblie
control device
5
Cables for charger
6
Transducer test plate
7
Documentation box containing the user manual, the
warranty certificate and the meteorology certificate.
8
Foam inlay
9
Cable for charging of mobile control device

12
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Scope of Delivery
Scope of Delivery
10
Transportation box
* A1040 MIRA 3D 4x8 configuration is delivered with only one charging device.

13
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Main Components
Main Components
7 Main Components

14
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Main Components
Main Components

15
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Main Components
Main Components

16
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Main Components
Main Components

17
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Keys and system LEDs
Keys and system LEDs
8 Keys and system LEDs
The A1040 Mira 3D Has two key -Types
Type One is the key for the operational preparation of the system and to run status
checks. This KEy is found on the Main Keypad
Figure 3: Keypad position
The Keypad has three basic functionalities. Switching the device on/off and start the
battery charging status. Detailed Information in given in the table below.
Figure 4: Keypad with LEDs
Key name
Functions
Power Key
[1]
Press and hold the POWER Key for 3 seconds to activate the device
Power Key
[1]
Press and release the POWER Key for the checking the battery status
Power Key
[1]
Press and hold the POWER Key for 3 seconds to deactivate the device
Power Key
[1]
Update procedure initiation (see chapter system update)
Type two is are the four trigger keys for the start of the acquisition during the system
operation.

18
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Keys and system LEDs
Keys and system LEDs
Key name
Functions
Trigger Key
[2]
Data acquisition
Trigger Key
[2]
Update initiation function when using WIFI as access point
The system LEDs have two basic functionalities, displaying the procedure mode and the
charging status.
Normal operation mode
LED Name
Functions/Meaning
ON [2]
Not lit when device is turned off
Flashing green during hardware initialization and booting
Constant green glow when the device is ready for operation
CONNECT
[3]
Not lit when device is turned off
Flashing green with 1 Hz frequency until a connection is established
with the access point of the control device.
Flashing green with 2 Hz frequency until the connection with the
control program is established.
Constant green glow when the Main Device is connected to the
control program and ready for operation
MASTER [4]
Not lit:
Option 1: The main device is not connected to the control program.
Option 2: The main device is acting as slave in combination 4x16 or
8x8 with another device.

19
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Keys and system LEDs
Keys and system LEDs
Constant orange glow when the device is connected as Master to the
control program.
UPDATE [5]
Not lit when device is in normal operation mode.
Constant orange glow when the Main Device is connected to a PC
and ready for receiving the update files. See chapter Update at
page
Flashing orange with 2 Hz frequency during the data transfer
process.
Error [6]
This LED has no functionality at the moment.
Checking the battery status mode. The LEDs are glowing constantly for a few
seconds according the charging status and then switch off. The main device will stay
switched off.
100 % [2]
green 100 % battery charging
75% [3]
green 75 % battery charging
50% [4]
orange 50 % battery charging
25% [5]
orange 25 % battery charging
10% [6]
red 10 % battery charging *
* at 10 % battery charging. the device should be recharged.
67

20
A1040 MIRA 3D © 2021 Acoustic Control Systems – ACS Group
Rechagreable Battery of the Main Device
Rechagreable Battery of the Main Device
9 Rechagreable Battery of the Main Device
The rechargeable batteries of the Main Device shall not to be replaced by the
operator, only by full trained personnel that has been authorized by ACS. For safety
reasons, do not attempt to remove or replace the battery.
Incorrect removal or replacement of the battery may result in damage to the
battery and the device, personal injury, and / or equipment damage including
impairment of safety.
ACS is not liable for any damage or loss (whether contractually or unauthorized,
including negligence) caused by not following this warning.
Before first use, the rechargeable batteries must
completely be charged.
If the instrument is not used for a period longer than three month, check charging
status by press ON key short. When the charge has dropped to 25 %, recharge the
device.
Make sure that the accumulator is completely charged once in two months, to
prevent total discharge.
In that case of total discharge, the rechargeable batteries may be destroyed and
must be replaced.
Use only ACS - approved chargers and cables. Unauthorized chargers or cables may
cause the batteries to explode or damage the device.
ACS is not liable for any damage or loss (whether contractually or unauthorized,
including negligence) caused by not following this warning.
Incorrect connection of the charger may cause serious damage to the device.
Damage caused by improper use is not covered by the warranty.
Charging of the rechargeable battery
1. Connect one end of the USB-C cable to the USB-C power supply, and the other
end to the USB-Connection of the Main Device
Other manuals for A1040 MIRA
2
This manual suits for next models
1
Table of contents