ADLINK Technology cPCI-6S10 Series User manual

Leading EDGE COMPUTING
Manual Rev. 1.0
Revision Date: September 3, 2018
Part No.: 50-15099-1000
cPCI-6S10 Series
6U CompactPCI Switch Blade
User’s Manual

ii Revision History
Leading EDGE COMPUTING
Revision History
Revision Release Date Description of Change(s)
1.0 03/09/2018 Initial release

Preface iii
cPCI-6S10
Preface
Copyright 2018 ADLINK Technology, Inc.
This document contains proprietary information protected by copy-
right. All rights are reserved. No part of this manual may be repro-
duced by any mechanical, electronic, or other means in any form
without prior written permission of the manufacturer.
Disclaimer
The information in this document is subject to change without prior
notice in order to improve reliability, design, and function and does
not represent a commitment on the part of the manufacturer.
In no event will the manufacturer be liable for direct, indirect, spe-
cial, incidental, or consequential damages arising out of the use or
inability to use the product or documentation, even if advised of
the possibility of such damages.
Environmental Responsibility
ADLINK is committed to fulfill its social responsi-
bility to global environmental preservation
through compliance with the European Union's
Restriction of Hazardous Substances (RoHS)
directive and Waste Electrical and Electronic
Equipment (WEEE) directive. Environmental
protection is a top priority for ADLINK. We have
enforced measures to ensure that our products,
manufacturing processes, components, and raw
materials have as little impact on the environment as possible.
When products are at their end of life, our customers are encour-
aged to dispose of them in accordance with the product disposal
and/or recovery programs prescribed by their nation or company.
Battery Labels (for products with battery)
ᑜ㔚ᳰ⺧࿁ᡴ

iv Preface
Leading EDGE COMPUTING
California Proposition 65 Warning
WARNING: This product can expose you to chemicals
including acrylamide, arsenic, benzene, cadmium,
Tris(1,3-dichloro-2-propyl)phosphate (TDCPP), 1,4-Diox-
ane, formaldehyde, lead, DEHP, styrene, DINP, BBP, PVC, and
vinyl materials, which are known to the State of California to cause
cancer, and acrylamide, benzene, cadmium, lead, mercury,
phthalates, toluene, DEHP, DIDP, DnHP, DBP, BBP, PVC, and
vinyl materials, which are known to the State of California to cause
birth defects or other reproductive harm. For more information go
to www.P65Warnings.ca.gov.
Trademarks
Product names mentioned herein are used for identification pur-
poses only and may be trademarks and/or registered trademarks
of their respective companies.
Conventions
Take note of the following conventions used throughout this
manual to make sure that users perform certain tasks and
instructions properly.
NOTE:
NOTE:
Additional information, aids, and tips that help users perform
tasks.
CAUTION:
Information to prevent minor physical injury, component dam-
age, data loss, and/or program corruption when trying to com-
plete a task.
WARNING:
Information to prevent serious physical injury, component
damage, data loss, and/or program corruption when trying to
complete a specific task.

Table of Contents v
cPCI-6S10
Table of Contents
Revision History...................................................................... ii
Preface.................................................................................... iii
List of Tables......................................................................... vii
List of Figures........................................................................ ix
1 Overview ............................................................................. 1
1.1 Block Diagram ..................................................................... 2
1.2 Package Contents ............................................................... 3
2 Specifications & Board Interfaces.................................... 5
2.1 cPCI-6S10 Specifications .................................................... 5
2.2 Board Layout ...................................................................... 6
2.3 Front Panel Layout .............................................................. 7
2.4 Connector Pinouts............................................................... 9
2.5 Switch Settings .................................................................. 17
3 Hardware Platform Management .................................... 19
3.1 Platform Management Overview ....................................... 19
3.2 IPMI Commands................................................................ 20
3.3 Controller Specific OEM/Group Commands...................... 59
4 Getting Started ................................................................. 65
4.1 Heatsink............................................................................. 65
4.2 Installing the cPCI-6S10 .................................................... 65
4.3 Configuring the cPCI-6S10................................................ 65
5 Software Management..................................................... 75
5.1 Introduction........................................................................ 75
5.2 Broadcom Network Switching Software SDK .................... 75
5.3 Commands ........................................................................ 76

List of Tables vii
cPCI-6S10
List of Tables
Table 2-1: cPCI-6S10 Specifications ......................................... 5
Table 3-1: NetFn codes ........................................................... 20
Table 3-2: Response Codes .................................................... 21
Table 3-3: Required Message Length for IPMI 1.5 .................. 22
Table 3-4: cPCIS-3300BLS Chassis Slots ............................... 23

viii List of Tables
Leading EDGE COMPUTING
This page intentionally left blank.

xListofFigures
Leading EDGE COMPUTING
This page intentionally left blank.

Overview 1
cPCI-6S10
1Overview
The ADLINK cPCI-6S10 is a fully managed CompactPCI Gigabit
Ethernet switch blade supporting up to twenty four 1GbE ports and
two 10GbE SPF+ uplink ports. On the front panel are three GbE
ports, two 10GbE SFP+ uplink ports, one COM port and one
10/100 RJ-45 management port. Twenty GbE ports are routed to
rear I/O and an IPMI interface is provided to monitor and control
system health.
The ADLINK cPCI-6S10 integrates Broadcom BCM56150 switch
silicon along with an ARM Cortex-A9 processor and one Broad-
com BCM54685 Octal port 1000BASE-T PHY. The cPCI-6S10 is
ideal for CompactPCI platform adopters who require high speed
and high bandwidth data transport interconnects for packet switch-
ing management.
The ADLINK cPCI-6S10 supports ADLINK PacketManager, a soft-
ware suite with an extensive feature set and integration capabili-
ties that enables powerful networking functionality for the Base
Interface. It also provides comprehensive device management
capabilities for network administrators.

2Overview
Leading EDGE COMPUTING
1.1 Block Diagram
Figure 1-1: cPCI-6S10 Series Block Diagram
MDI x1ʳ
BCM54685ʳ
MDI x1ʳ
MDI x8ʳ
Front Panelʳ
MDI x11ʳ
GbE x3ʳ
10G
SFP+ x2ʳ
Mgt x1ʳ
RJ-45
COM x1ʳ
LEDʳ
MDI x3ʳ
UARTʳ
Atmel
IPMC
UARTʳ
SFI x2ʳBCM56150
CompactPCI
Conn.ʳ
J1ʳ
J2ʳ
J3ʳ
J4ʳ
J5ʳ

Overview 3
cPCI-6S10
1.2 Package Contents
The cPCI-6S10 is packaged with the components listed below
(RTMs and adapter kits are optional). If any of the items in the
contents list are missing or damaged, retain the shipping carton
and packing material and contact the dealer for inspection. Please
obtain authorization before returning any product to ADLINK. The
packing contents of non-standard configurations may vary
depending on customer requests.
XcPCI-6S10 CompactPCI switch blade
XRJ-45 to DB-9 adapter for UART port
NOTE:
NOTE:
The contents of non-standard cPCI-6S10 Series configurations
may vary depending on customer requests.
CAUTION:
This product must be protected from static discharge and phys-
ical shock. Never remove any of the components except at a
static-free workstation. Use the anti-static bag shipped with the
product when putting the board on a surface. Wear an
anti-static wrist strap properly grounded on one of the system's
ESD ground jacks when installing or servicing system compo-
nents.

4Overview
Leading EDGE COMPUTING
This page intentionally left blank.

Specifications & Board Interfaces 5
cPCI-6S10
2 Specifications & Board Interfaces
2.1 cPCI-6S10 Specifications
Table 2-1: cPCI-6S10 Specifications
Standards and Interfaces
CompactPCI
Standard
PICMG 2.0 CompactPCI Rev. 3.0
PICMG 2.9 System Management Bus Rev. 1.0
PICMG 2.16 Packet Switching Backplane Rev.1.0
Switch Fabric,
PHY
• Broadcom BCM56150 24-port GbE switch with two 10G SFP+ uplink
ports
• Broadcom BCM54685 Octal-port 10/100/1000BASE-T PHY
• Broadcom BCM5221 10/100BASE-TX management port
Networking
• 3x 10/100/1000BASE-T ports to front panel (BCM56150)
• 20x 10/100/1000BASE-T ports to rear (BCM56150, 9x to J3, 11x to J5)
• 1x inter-switch link 1000BASE-T
• 2x 10G SFP+ ports for uplink through BCM56150
• 1x 10/100BASE-TX for management
Front Panel IO
3x 10/100/1000BASE-T RJ-45 ports
2x 10G SFP+ interfaces for uplink interface
1x 10/100 RJ-45 management port
1x UART port via RJ-45
Rear IO 20x 10/100/1000BASE-T ports to J3 and J5
Mechanical & Environmental
Dimensions 233.35mm x 160mm (L x W), 6U 4HP single slot
Operating
Temp. Standard: 0°C to 60°C
ETT version upon request
Storage Temp. -50°C to 100°C
Humidity 95% non-condensing
Shock 15G peak-to-peak, 11ms duration, non-operating
Vibration Non-operating: 2Grms, 5 to 500 Hz, each axis
Compliance CE, FCC Class A
Power
Consumption
(under Linux)
• Idle (w/o RTM): 12.2W
• Full loading (w/o RTM): 15W
• Idle (w/ RTM): 15.5W
• Full loading (w/ RTM): 20W
NOTE:
NOTE:
Specifications are subject to change without prior notice.

6 Specifications & Board Interfaces
Leading EDGE COMPUTING
2.2 Board Layout
Figure 2-1: cPCI-6S10 Board Layout
U100 BCM5221 RJ1-3 10/100/1000 GbE
U67 BCM56150 RJ4 10/100 Mgmt GbE
U66 BCM54685 CN6 UART Port
J1-J5 CompactPCI connectors CN22-23 SFP+ Uplink ports
SW6 Standalone mode switch
U67
U66
U100
J1
J2
J3
J4
J5
RJ1
RJ3
RJ2
RJ4
CN23
CN22
CN6
SW6

Specifications & Board Interfaces 7
cPCI-6S10
2.3 Front Panel Layout
The following section describes the behavior of the LEDs on the
front panel.
Power LED
HW LED (Hardware Health)
Power LED (Green) Status
On Power status normal
Off Power off
HW LED (Yellow) Status
On POST and sensor status
of IPMC is normal
Blinking TBD
Off POST and sensor status
of IPMC is abnormal
Management
Port
SFP+ COM GbE x3 LED x22 HW LED
Power LED

8 Specifications & Board Interfaces
Leading EDGE COMPUTING
Rear IO GbE Status LEDs (LP1 - LP20)
SFP+ Status LEDs (XE 0 - XE 1)
Upper LED
On: Link up
Off: Link down
Lower LED
Blink: Packet Activity
Link LED (Green)
ON: Link up
OFF: Link down
Act LED (Orange)
Blink: Packet Activity

Specifications & Board Interfaces 9
cPCI-6S10
2.4 Connector Pinouts
UART COM Connector (CN6)
Set SW21 to IPMI or BCM56150 UART MUX debug port
RJ-45 10/100BASE-T Mgmt. Ethernet Connector (RJ4)
Pin # 10BASE-T/
100BASE-TX
1NC
2NC
3NC
4 IPM_DBG_TX
5 IPM_DBG_RX
6GND
7NC
8NC
Pin # 10BASE-T/
100BASE-TX
1NC
2NC
3NC
4 IPM_DBG_TX
5 IPM_DBG_RX
6GND
7NC
8NC
18
18

10 Specifications & Board Interfaces
Leading EDGE COMPUTING
RJ-45 Gigabit Ethernet Connectors ((RJ1/2/3)
GbE Status LEDs
Pin # 1000BASE-T
1LAN_TX0+
2 LAN_TX0-
3LAN_TX1+
4LAN_TX2+
5 LAN_TX2-
6 LAN_TX1-
7LAN_TX3+
8LAN_TX3+
Left LED
On: Link up
Off: Link down
Right LED:
Blink: Packet Activity
18
Link Activity
Table of contents
Other ADLINK Technology Switch manuals
Popular Switch manuals by other brands

Murphy
Murphy TSB Specification sheet

TP-Link
TP-Link JetStream TL-SG2008 reference guide

Chromalox
Chromalox HVS-02 nstallation Instructions and RENEWAL PARTS IDENTIFICATION

Clarion
Clarion MSS7100 Owner's manual & installation manual

Sony
Sony DVS-V3232M Operation manual

Dymec
Dymec KY-501U installation guide