ADS-tec IRF2000 series User manual

Instruction manual
IT Infrastructure
IRF2000 series - standard
Version 2.7
Updated 2020-03-30
Translation of the original
instruction manual

IRF2000 series - standard Doc v2.7 2
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
Table of Contents
1Notes.......................................................................................................................................4
1.1 General remark 4
1.2 Limitation of liability 4
1.3 Manufacturer 4
1.4 Relevant device documentation 5
2Safety instructions ...................................................................................................................6
2.1 Structure of safety instructions 6
2.2 Graduation of risk level 6
2.3 Explanation of used symbols 6
2.4 Symbols 7
2.5 Data, figures and modifications 7
2.6 Trademarks 8
2.7 Copyright 8
2.8 Compliance 9
3Operating and safety instructions ...........................................................................................11
3.1 Safety instructions 12
3.2 Operating location 13
3.3 Damage due to improper use 13
3.4 Warranty / repairs 13
3.5 Intended use 13
3.6 Improper use 14
3.7 Safety instructions 15
3.8 Safety instructions concerning mobile telephony and GNSS (GPS) 16
3.9 Calculation example for the transmission power (EIRP) 17
4Introduction...........................................................................................................................18
4.1 Cut & Stop 18
4.2 Alarming 18
4.3 Event log 18
4.4 Mobile phone modem 18
4.5 Equipment versions 19
4.6 Scope of delivery 19
4.7 Environmental conditions 20

IRF2000 series - standard Doc v2.7 3
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5Assembly ...............................................................................................................................21
5.1 External dimensions IRF22xx 21
5.2 External dimensions IRF26xx 22
5.3 Mounting options 23
5.3.1 Table mounting 23
5.3.2 Wall mounting 23
5.3.3 Top-hat rail mounting 24
6System features .....................................................................................................................25
6.1 General LED status display 25
6.1.1 Front LEDs 26
6.2 Operational LED status indicators 27
6.2.1 Behaviour of the status indicators during the boot-up process 27
6.2.2 Behaviour of the status indicators when resetting to default settings 27
6.2.3 Behaviour of the status indicators during a firmware update 27
6.3 Interface overview IRF22xx 28
6.4 Interface overview IRF26xx 29
6.4.1 Power supply 24 VDC 31
6.4.2 LAN (RJ45) 32
6.4.3 WAN (RJ45) 32
6.4.4 VPN Control 32
6.4.5 CUT & ALARM 33
6.4.6 Serial interface COM (RS232) 33
6.4.7 USB connections 34
6.4.8 Smartcard reader in accordance with ISO 7816 34
7Putting into operation ............................................................................................................35
7.1 Initial configuration 35
7.2 Manual configuration of the network adapter 36
7.3 Settings for use with Internet Explorer 8 37
7.4 Calling up the device web interface 37
8Technical data........................................................................................................................39
9Service & support...................................................................................................................41
9.1 ADS-TEC support 41
9.2 Company address 41

IRF2000 series - standard Doc v2.7 4
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1 Notes
1.1 General remark
This instruction manual is intended to ensure safe and efficient handling and operation of IT
Infrastructure products.
The instruction manuals must be read carefully by personnel before commencing any type of work.
All of the safety notices and handling instructions given in the manual must be obeyed in order to
ensure that work is carried out safely.
Operation of the system is subject to the laws and regulations which are applicable in the respective
country at national, federal, European and international level.
The generally accepted rules of technology, usually in the form of standards, directives, regulations,
conditions and technical rules specified by national and federal organisations as well as trade
associations and committees for the field of specialisation concerned, shall apply.
Figures used in this instruction manual are provided for basic understanding and may differ from the
actual design.
The operator/operating company is independently responsible for compliance with and observance of
any subsequently introduced technical innovations or new legal requirements, as well as for all usual
obligations of the operator/operating company.
The original version of this instruction manual was written in German. All non-German versions of this
instruction manual are translations of the German instruction manual.
1.2 Limitation of liability
ads-tec Industrial IT GmbH shall not be liable for personal injury, property damage or damage caused to
the product as well as consequential damage that is/was the result of non-compliance with this
instruction manual, improper use of the product, repairs and other actions on the product by unqualified
specialists and specialists not certified by ads-tec Industrial IT GmbH, or that is/was the result of using
unapproved replacement parts.
1.3 Manufacturer
The manufacturer of the product is ads-tec Industrial IT GmbH. The company is referred to in the
following as ADS-TEC.

IRF2000 series - standard Doc v2.7 5
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1.4 Relevant device documentation
The following documents are decisive to unit setup and operation:
•This instruction manual: Contains information for installation, commissioning and operation of
the device along with technical data of the device hardware.
•Data sheets for IRF22xx and IRF26xx: Contain detailed technical data.
•Website: You can download drivers, software, user manuals, data sheets, leaflets and flyers
from the Download section of our website www.ads-tec.de.

IRF2000 series - standard Doc v2.7 6
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2 Safety instructions
2.1 Structure of safety instructions
The signal word classifies the hazard. Reference to the type/consequences and source of the hazard is
made underneath the signal word. Instructions for preventing the hazard are identified by an arrow ().
SIGNAL WORD
Type/consequences of hazard!
- Source of hazard
Measures to prevent hazard
2.2 Graduation of risk level
The signal word classifies the hazard.
Instructions for preventing the hazard are identified by an arrow ().
2.3 Explanation of used symbols
DANGER
Indicates an imminent danger.
If not avoided, death or severe injury will result.
WARNING
Indicates a possible danger.
If not avoided, death or severe injury could result.
CAUTION
Indicates a possible danger.
If not avoided, light or minor injuries could result.
ATTENTION
Indicates a possibly damaging situation. If not avoided, the system or
something in its surroundings could be damaged.

IRF2000 series - standard Doc v2.7 7
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
Recommendation for use:
The symbol "Recommendation for use" indicates terms and/or conditions that strictly
need to be observed to ensure optimised and/or zero-defect operation. Tips and
suggestions for the efficient use of the device and software optimisation are also
provided.
2.4 Symbols
Symbol Meaning
Designation of batteries in accordance with § 13 of the German
Battery Act (BattG). Batteries may not be disposed of with
household waste, but must rather be disposed of separately. Used
batteries must be returned to the point of sale or a disposal system.
Labelling of electrical and electronic devices in accordance with § 7
of the German Electrical and Electronic Equipment Act (ElektroG).
Electrical and electronic devices must not be disposed of with
household waste, but must rather be taken to a collection point for
waste electrical equipment. Such a collection point is generally
operated by public waste management authorities, i.e., by
municipalities.
Symbol for the protective earth connection
2.5 Data, figures and modifications
All data, text and figures were prepared to the best of our knowledge. They do not represent any
assurance for the properties themselves. Despite taking utmost care, no liability can be assumed for
accuracy, completeness and actuality of the information. Subject to changes.

IRF2000 series - standard Doc v2.7 8
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2.6 Trademarks
It is noted that any software and/or hardware trademarks and any company brand names mentioned in
this documentation are all subject to the general trademark protection rights.
StoraXe® and Big-LinX® are registered trademarks of ADS-TEC.
All other third-party trademarks used are hereby acknowledged.
In the case of infringement of trademark rights, ADS-TEC reserves the right to exercise all rights.
2.7 Copyright
This instruction manual is protected by copyright. For the authorised user, simple usage rights are
granted within the scope of the intent of the contract. Any modified use or exploitation of the provided
content, particularly duplication, modification or publishing in whatever form is permitted only with the
prior consent of ADS-TEC.
In the case of copyright infringement, ADS-TEC reserves the right to exercise all rights.

IRF2000 series - standard Doc v2.7 9
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2.8 Compliance
The manufacturer hereby declares that this device has been marked with the CE mark in accordance
with the basic requirements and other relevant conditions of the following European Directives:
•2011/65/EU, RoHS Directive
•2014/30/EU, EMC Directive
•2014/53/EU, RED Directive
•2014/35/EU, Low Voltage Directive
A corresponding EU conformity declaration is available for competent authorities at the manufacturer
and can be viewed upon request.
The EU conformity declaration can be requested at
http://www.ads-tec.de/en/support/support-request.html and is available for download at http://www.ads-
tec.de/en/support/download/industrial-it/ec-declaration-of-conformity.html
Recommendation for use:
For full compliance with the EMC legislation, all components and cables used for
device connection must also be compliant with these requirements. It is therefore
necessary to employ BUS and LAN cables with shielded connectors and these
must be installed as per the instructions contained in the instruction manual.

IRF2000 series - standard Doc v2.7 10
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
Devices with FCC mark on the type plate:
Conformance with FCC rules (USA)
Class A digital device – instructions:
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.
This conformance is valid for the versions with a FCC marking on the type plate.

IRF2000 series - standard Doc v2.7 11
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3 Operating and safety instructions
The device operates under electrical voltage and contains highly sensitive components. Intervention by
the user is required only for connecting the power supply lines. Should any further modifications be
required, it is necessary to consult either with the manufacturer directly or with service personnel
authorised by the manufacturer. The device must be de-energised during work. Appropriate measures
must be taken to prevent electrostatic discharges on components. If the device is opened up by an
unauthorised person, the user may be subject to hazards and the warranty is invalidated.
General information
Assembly, commissioning and operation may only be performed by qualified and
trained personnel
The safety notices and the instruction manual are to be observed by all persons
who work with the device
At the installation site the valid guidelines and regulations for accident prevention
must be observed
The instruction manual contains the most important information for safely
operating the device
Appropriate storage, proper transport, installation and commissioning, as well as
careful operation are prerequisites for ensuring safe and proper operation of the
device
Recommendation for use:
Only the original ADS-TEC firmware / software is allowed for any of the settings
and features described in this instruction manual. Loading of any firmware /
software that has not been released by ADS-TEC invalidates the warranty.

IRF2000 series - standard Doc v2.7 12
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3.1 Safety instructions
ATTENTION
To prevent damage to the device, all cable lines (power supply, interface cables) must
be only be connected while the device is switched off.
ATTENTION
All installation work performed on the device must be performed only under safe,
secure and de-energised conditions.
CAUTION
Warning - hot surface
Protective gloves must be worn when handling devices with ambient temperatures
of 50 °C and higher.
Disregarding this warning can result in burn injuries or damage to property.
Recommendation for use:
Always adhere to the safety measures applicable when handling components at risk
of being damaged by electrostatic discharges. (DIN EN 61340-5-1 / DIN EN 61340-
5-2)

IRF2000 series - standard Doc v2.7 13
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3.2 Operating location
This device is designed for industrial use. Make certain that the specified environmental conditions are
maintained at all times. Use in non-specified environments, i.e., on board ships, in explosive
atmospheres or at extreme elevations, is prohibited.
ATTENTION
Risk of short circuit!
To prevent the formation of water condensate, the device may be turned on only after
it has reached the specified ambient temperature. This also applies if the device is
exposed to extreme temperature fluctuations.
Avoid overheating in operation!
The device must not be exposed to direct radiation by sunlight or any other light or
heat source.
Pollution degree acc. to IEC 61010-1 and CSA 22.2 No 107.1-01: pollution degree 2.
This device is designed for use in a controlled environment.
3.3 Damage due to improper use
Should the control system have evident signs of damages caused, e.g., by improper operation or
storage conditions or due to improper use or handling, the device must be shut down immediately.
Ensure that it is secured against being started up accidentally.
3.4 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by
service personnel that has been authorised by the manufacturer.
3.5 Intended use
The Industrial Firewall was specifically designed for the IT security of plant and machinery and the
secure remote maintenance via Internet.
The following applications are realized by the Industrial Firewall:
Remote maintenance, NAT routers, wireless routers, firewall machines, Gigabit Router.
Application-specific applications are buildable on various software development kits (SDK).
The unit must only be installed and operated within the allowed specifications.
The use of an unspecified environment is prohibited.

IRF2000 series - standard Doc v2.7 14
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3.6 Improper use
Operation other than or beyond that described for the device shall be deemed improper use.
The device is not allowed to be used to control vehicles or for applications for which further approvals
beyond the manufacturer's declaration are necessary, e.g. applications with explosion hazard, medical
technology, shipping industry.
The device must not be put into operation in the case of transport damage or nonconformity with the
specifications and, if necessary, must be taken out of operation in the case of changing conditions.
In the case of improper use, ADS-TEC shall not accept responsibility or liability for injury or damage that
is directly or indirectly attributable to the handling of the device.
Should the device have evident signs of damages caused, e.g., by improper operation or storage
conditions or due to improper use or handling, it must be shut down immediately. Ensure that it is
secured against being started up accidentally.

IRF2000 series - standard Doc v2.7 15
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3.7 Safety instructions
ATTENTION
Damage due to electrostatically sensitive components
Damage to the device can be caused by electrostatically sensitive components.
All installation and service work performed on the device must be performed only
under safe, secure and de-energised conditions.
Recommendation for use:
Always adhere to the safety measures applicable when handling components at risk
of being damaged by electrostatic discharges.
The provisions of DIN EN 61340-5-1 / DIN EN 61340-5-2 apply.

IRF2000 series - standard Doc v2.7 16
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3.8 Safety instructions concerning mobile telephony and
GNSS (GPS)
WARNING
Radio interference may have unforeseeable effects in certain environments!
•The wireless card must NOT be operated in the following environments:
in the vicinity of medical and life-saving equipment,
in explosive atmospheres (e.g. in the vicinity of fuel depots or chemical
plants),
in the vicinity of blasting operations.
•In these environments, switch the device OFF and safeguard it against
unintentional startup.
WARNING
Risk of lightning strikes if the antenna is installed in an exposed position!
•Check whether lightning protection is required at the installation location
(protection from direct lightning strikes and protection from induced voltages
in the event of distant lightning strikes).
WARNING
Communication via wireless connections cannot be guaranteed.
•The device must not be used for applications in which people could be
injured or objects damaged due to interference of the wireless connection.
WARNING
Strong electromagnetic radiation is considered hazardous to health.
•In accordance with the rules of FCC/IC (Industry Canada), maintain at all
times a separation distance of at least 20 cm between the antenna and the
user’s body.

IRF2000 series - standard Doc v2.7 17
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
WARNING
Radio interference and possible health damage due to exceeding the permitted
transmission power!
The maximum permitted field strength can be exceeded when using directional
antennas with a high level of antenna gain.
•Comply with the maximum permitted signal strength (EIRP) as per the
national or local regulations (see calculation example for EIRP).
•Observe the regulations and standards which apply at the installation site
(e.g. the standards for antenna erection VDE 0855 and for lightning
protection VDE 0185-305).
•Always have the planning, installation and acceptance of antenna systems
carried out by a specialist with electro-technical qualifications.
•To comply with FCC / IC regulations limiting both maximum RF output power
and human exposure to RF radiation, the maximum antenna gain including
cable loss in a mobile-only exposure condition must not exceed:
6.5 dBi in Cellular band
3.0 dBi in PCS band
3.0 dBi in LTE Band 2
6.0 dBi in LTE Band 4
6.5 dBi in LTE Band 5
9.0 dBi in LTE Band 13
9.0 dBi in LTE Band 17
3.0 dBi in LTE Band 25
3.9 Calculation example for the transmission power (EIRP)
EIRP = Pout - Closs + Antgain = 22 dBm - 8 dB + 9 dBi = 23 dBm (≙200 mW)
EIRP = Equivalent Isotropically Radiated Power
Pout = Transmission power of the device
Closs = Losses caused by attenuation in the coaxial cable
Antgain = Antenna gain

IRF2000 series - standard Doc v2.7 18
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4 Introduction
The Industrial Firewall forms the link between the IT world and the automation system and meets the
requirements of IT security as well as of the maintenance personnel in the production facility. It allows
the network in plants and machines as well as access to this network to be monitored. Its fundamental
protective mechanism is situation-dependent and physical network disconnection. It additionally
provides safe access for service purposes, allows traffic shaping and can use existing virus scanners.
4.1 Cut & Stop
In critical start-up or production phases, the WAN interface can be disconnected via a 24 V input. This
makes deliberate or inadvertent manipulation absolutely impossible.
The WAN interface is reconnected via the same input. This function makes integration in an automation
concept extremely easy.
4.2 Alarming
In the event of rule violation, the alarm signal is sent to the control system via an output. Necessary
measures can be automated directly.
Acoustic indicator lights can, for example, signal the alarm condition.
Automatically sent emails can warn of rule violation.
4.3 Event log
If the firewall is disconnected from the power supply, a non-volatile event log saves all events.
The event log can be read out both locally and via a central syslog server.
4.4 Mobile phone modem
Connection is possible via LTE/UMTS/GSM using the integrated modem.

IRF2000 series - standard Doc v2.7 19
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4.5 Equipment versions
The device is available in five equipment versions.
Version WAN LAN 3G/UMTS 4G/LTE
IRF2200 RJ45 RJ45 - -
IRF2210 RJ45 RJ45 x -
IRF2220 RJ45 RJ45 x
IRF2601 RJ45 RJ45 - -
IRF2621 RJ45 RJ45 - x
RJ45 is an Ethernet standard frequently implemented in telecommunication applications. The
transmission method is equivalent to 10/100/1000Mbits half & full DUPLEX 1000 BASE-TX.
4.6 Scope of delivery
The contents of the package must be checked for completeness:
Scope of delivery
1 x Industrial Router Firewall with top-hat rail holder
1 x 3-pin plug
2 x 4-pin plug
4 x rubber feet
Ethernet cable 1m red
Quick Start-Up Guide / Quick Assembly Guide

IRF2000 series - standard Doc v2.7 20
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4.7 Environmental conditions
The device can be put into operation and used under the following conditions. Failure to observe any
one of these conditions will invalidate the warranty. ADS-TEC cannot be held liable for any damages
arising from improper use and handling.
Ambient temperature
in operation -20°C ... + 70°C
for storage -20°C ... + 85°C
Humidity
in operation 5 to 90%, without condensate
for storage 5 to 90%, without condensate