ADS-tec IRF3000 Series User manual

00
Instruction manual
Industrial router & firewall
IRF3000 series
Translation of the original
instruction manual
Version 1.1
Updated 2023-01-11

IRF3000 series Instruction manual v1.1 2
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
Table of Contents
1Notes.......................................................................................................................................4
1.1 General remark 4
1.2 Manufacturer 4
1.3 Limitation of liability 4
1.4 Relevant device documentation 5
2Safety instructions ...................................................................................................................6
2.1 Structure of safety instructions 6
2.2 Graduation of risk level 6
2.3 Explanation of used symbols 6
2.4 Symbols 7
2.5 Data, figures and modifications 7
2.6 Trademarks 8
2.7 Copyright 8
2.8 Conformity 9
3Operating and safety instructions ...........................................................................................10
3.1 Safety instructions 11
3.2 Operating location 11
3.3 Damage due to improper use 11
3.4 Warranty / repairs 12
3.5 Intended use 12
3.6 Improper use 12
3.7 Safety instructions 12
3.8 Safety instructions on mobile radio 13
3.9 Calculation example for the transmission power (EIRP) 14
3.10 Notes on using the device according to UL approval 15
4Introduction...........................................................................................................................16
4.1 Equipment versions 16
4.2 Event log 16
4.3 Mobile radio modem (optional) 16
4.4 Scope of delivery 16
4.5 Environmental conditions 17
5Installation.............................................................................................................................18
5.1 External device dimensions IRF34x1 18
5.2 External device dimensions IRF38x1 19
5.3 Top-hat rail mounting 20
5.4 Optional accessory: Attaching the VESA holder 20
5.5 Optional: Attaching antennas 21

IRF3000 series Instruction manual v1.1 3
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
6Electrical interfaces ................................................................................................................22
6.1 Power supply 22
6.2 Modbus RTU (RS-485) 23
6.3 Digital I/O #2 23
6.4 Digital I/O #3…5 23
6.5 Smart card reader and slot for SIM card 24
7Commissioning.......................................................................................................................25
7.1 Connecting the device to a laptop or PC 25
7.2 Configuration of the network adapter of the PC 25
7.3 Calling up the device web interface 26
7.4 Front LEDs 27
7.5 Operating-mode related LED status displays 28
7.5.1 Boot-up 28
7.5.2 Resetting to default settings 28
7.5.3 Firmware update 28
8Technical data........................................................................................................................29
9Service & support...................................................................................................................30
9.1 ADS-TEC support 30
9.2 Company address 30

IRF3000 series Instruction manual v1.1 4
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
1 Notes
1.1 General remark
This instruction manual is intended to ensure safe and efficient handling of the
industrial router and firewall of type IRF3xxx, referred to in the following as "device".
The instruction manual must be read carefully by personnel before commencing any type of work.
All of the safety instructions and handling instructions given in the manual must be obeyed in order to
ensure that work is carried out safely.
Operation of the device is subject to the laws and regulations which are applicable in the respective
country at national, federal, European and international level.
The generally accepted rules of technology, usually in the form of standards, directives, regulations,
conditions and technical rules specified by national and federal organisations as well as trade
associations and committees for the field of specialisation concerned, shall apply.
Figures used in this instruction manual are provided for basic understanding and may differ from the
actual design.
The operator/operating company is independently responsible for compliance with and observance of
any subsequently introduced technical innovations or new legal requirements, as well as for all usual
obligations of the operator/operating company.
The original version of this instruction manual was written in German. All non-German versions of this
instruction manual are translations of the German instruction manual.
1.2 Manufacturer
The manufacturer of the product is ads-tec Industrial IT GmbH. The company is referred to in the
following as ADS-TEC.
1.3 Limitation of liability
ADS-TEC shall not be liable for personal injury, property damage or damage caused to the device as
well as consequential damage that is/was the result of non-compliance with this instruction manual,
improper use of the device, repairs and other actions on the device by unqualified electricians and
electricians not certified by ADS-TEC, or that is/was the result of using unapproved replacement parts.
Failure to observe the maintenance intervals shall also result in exclusion from liability. Furthermore, it is
strictly forbidden to make any unauthorised alterations or technical modifications to the device.

IRF3000 series Instruction manual v1.1 5
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
1.4 Relevant device documentation
The following documents are decisive to device setup and operation:
•This instruction manual contains information for installation, commissioning and operation of the
device along with technical data of the device hardware.
•Technical data sheet (see download area)
•Website: You can download drivers, software, user manuals, leaflets and flyers from the
Download area of our website www.ads-tec.com

IRF3000 series Instruction manual v1.1 6
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
2 Safety instructions
2.1 Structure of safety instructions
The signal word classifies the hazard.
Reference to the type/consequences and source of the hazard is made underneath the signal word.
Information on how to avoid the hazard is indicated by an arrow ().
SIGNAL WORD
Type/consequences of hazard!
- Source of hazard
Measures to prevent hazard
2.2 Graduation of risk level
The signal word classifies the hazard.
Instructions for preventing the hazard are identified by an arrow ().
2.3 Explanation of used symbols
DANGER
Indicates an imminent danger. If not avoided, death or severe injury will result.
WARNING
Indicates a possible danger. If not avoided, death or severe injury could result.
CAUTION
Indicates a possible danger. If not avoided, light or minor injuries could result.
ATTENTION
Indicates a possibly damaging situation. If not avoided, the system or something in
its surroundings could be damaged.

IRF3000 series Instruction manual v1.1 7
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
Recommendation for use:
The symbol "Recommendation for use" indicates terms and/or conditions that strictly
need to be observed to ensure optimised and/or zero-defect operation. Tips and
suggestions for the efficient use of the device and software optimisation are also
provided.
2.4 Symbols
Symbol
Meaning
Label on batteries. The batteries may not be disposed of with
household waste, but must rather be disposed of separately. Used
batteries must be returned to the point of sale or a disposal system.
Label on electrical and electronic devices. Electrical and electronic
devices must not be disposed of with household waste, but must
rather be taken to a collection point for waste electrical equipment.
Such a collection point is generally operated by public waste
management authorities, i.e., by municipalities.
Symbol for the protective earth connection (PE)
Symbol for the functional earth connection (FE)
2.5 Data, figures and modifications
All data, text and figures were prepared to the best of our knowledge. They do not represent any
assurance for the properties themselves. Despite taking utmost care, no liability can be assumed for
accuracy, completeness and actuality of the information. Subject to changes.

IRF3000 series Instruction manual v1.1 8
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
2.6 Trademarks
It is noted that any software and/or hardware trademarks and any company brand names mentioned in
this documentation are all subject to the general trademark protection rights.
Big-LinX®and X-Remote®are registered trademarks of ADS-TEC.
All other third-party trademarks used are hereby acknowledged.
In the case of infringement of trademark rights, ADS-TEC reserves the right to exercise all rights.
2.7 Copyright
This instruction manual is protected by copyright. For the authorised user, simple usage rights are
granted within the scope of the intent of the contract. Any modified use or exploitation of the provided
content, particularly duplication, modification or publishing in whatever form is permitted only with the
prior consent of ADS-TEC.
In the case of copyright infringement, ADS-TEC reserves the right to exercise all rights.

IRF3000 series Instruction manual v1.1 9
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
2.8 Conformity
The manufacturer hereby declares that this device has been marked with the CE mark in accordance
with the basic requirements and other relevant conditions of the following European Directives:
•2011/65/EU RoHs Directive
•2014/30/EU EMC Directive (only devices without WWAN)
•2014/53/EU RED Directive (only devices with WWAN)
•2014/35/EU Low Voltage Directive
•EG 1907/2006 REACH Regulation
The following applies with respect to electromagnetic compatibility: The device is a Class A device
(industrial sector).
The EU conformity declaration is available for download at
https://www.ads-tec.de/en/support/download/industrial-it/ec-declaration.html.
Recommendation for use:
For full compliance with the EMC legislation, all components and cables used for
device connection must also be compliant with these requirements. It is therefore
necessary to employ BUS and LAN cables with shielded connectors and these must
be installed as per the instructions contained in the instruction manual.
Devices with FCC marking on the type plate:
Compliance with the requirements of the FCC (USA)
Class A digital device
This device has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when used in a commercial
environment. This device generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. Operation of this device in a residential area is
likely to cause harmful interference. In such a case, the user must correct the
interference at his own expense.
Compliance applies for models with a corresponding FCC marking on the type plate.

IRF3000 series Instruction manual v1.1 10
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
3 Operating and safety instructions
The device operates under electrical voltage and contains highly sensitive components. Intervention by
the user is required only for connecting the power supply lines. Should any further modifications be
required, it is necessary to consult either with the manufacturer directly or with service personnel
authorised by the manufacturer. The device must be de-energised during work. Appropriate measures
must be taken to prevent electrostatic discharges on components. If the device is opened up by an
unauthorised person, the user may be subject to hazards and the warranty is invalidated.
General information
Installation, commissioning and operation may only be performed by qualified and
trained personnel.
The safety instructions and the instruction manual are to be observed by all
persons who work with the device.
At the installation site the valid guidelines and regulations for accident prevention
must be observed.
The instruction manual contains the most important information for safely
operating the device.
Appropriate storage, proper transport, installation and commissioning, as well as
careful operation are prerequisites for ensuring safe and proper operation of the
device.

IRF3000 series Instruction manual v1.1 11
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
3.1 Safety instructions
ATTENTION
To prevent damage to the device, all cable lines (power supply, interface cables) must
only be connected while the device is switched off.
ATTENTION
All installation work performed on the device must be performed only under safe, secure
and de-energised conditions.
Recommendation for use:
Always adhere to the safety measures applicable when handling components at
risk of being damaged by electrostatic discharges (EN 61340-5-1 / EN 61340-5-2).
3.2 Operating location
This device is designed for industrial use. Make certain that the specified environmental conditions are
maintained at all times. Use in non-specified environments, i.e., on board ships, in explosive
atmospheres or at extreme elevations, is prohibited. See also chapter 8 Technical data.
ATTENTION
Damage caused by condensation!
To prevent short circuits and malfunctions caused by the formation of water condensate,
the device may only be turned on after it has reached the specified ambient
temperature. This also applies if the device is exposed to extreme temperature
fluctuations.
Damage caused by heat!
Do not expose the device to direct radiation by sunlight or any other light or heat
source!
3.3 Damage due to improper use
Should the control system have evident signs of damages caused, e.g., by improper operation or
storage conditions or due to improper use or handling, the device must be shut down immediately.
Ensure that it is secured against being started up accidentally.

IRF3000 series Instruction manual v1.1 12
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
3.4 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by
service personnel that has been authorised by the manufacturer.
3.5 Intended use
The device was developed especially for IT security in machines and plants and for secure remote
maintenance via the Internet.
The following application areas are realised with the industrial firewall:
Remote maintenance, NAT router, mobile radio router, machine firewall
The device is only to be assembled, installed and operated within the permissible specifications. Use in
non-specified environments is prohibited.
3.6 Improper use
Operation other than or beyond that described for the device shall be deemed improper use.
The device is not allowed to be used to control vehicles or for applications for which further approvals
beyond the manufacturer's declaration are necessary, e.g. applications with explosion hazard, medical
technology, shipping industry. The device must not be put into operation in the case of transport
damage or nonconformity with the specifications and, if necessary, must be taken out of operation in the
case of changing conditions.
In the case of improper use, ADS-TEC shall not accept responsibility or liability for injury or damage that
is directly or indirectly attributable to the handling of the device. Should the device have evident signs of
damages caused, e.g., by improper operation or storage conditions or due to improper use or handling,
it must be shut down immediately. Ensure that it is secured against being started up accidentally.
3.7 Safety instructions
ATTENTION
Damage due to electrostatic discharge!
Damage to the device can be caused by electrostatic discharge.
•Always adhere to the relevant safety measures applicable when handling
components at risk of being damaged by electrostatic discharge (e.g. EN 61340-
5-1 / EN 61340-5-2).
•All installation and service work performed on the device must be performed only
under safe, secure and de-energised conditions.

IRF3000 series Instruction manual v1.1 13
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
3.8 Safety instructions on mobile radio
WARNING
Radio interference may have unforeseeable effects in certain environments!
•The wireless card must NOT be operated in the following environments:
– in the vicinity of medical and life-saving equipment,
– in explosive atmospheres (e.g. in the vicinity of fuel depots or chemical
plants),
– in the vicinity of blasting operations.
•In these environments, switch the device OFF and safeguard it against
unintentional startup.
WARNING
Communication via wireless connections cannot be guaranteed.
•The device must not be used for applications in which people could be
injured or objects damaged due to interference of the wireless connection.
WARNING
Risk of lightning strikes if the antenna is installed in an exposed position!
•Check whether lightning protection is required at the installation location
(protection from direct lightning strikes and protection from induced voltages
in the event of distant lightning strikes).
WARNING
Electromagnetic radiation could be hazardous to health.
•Per the requirements of the U.S. Federal Communications Commission
(FCC) and ISED (Industry Canada), maintain a minimum distance of 20 cm
between the transmitting antennas and people.

IRF3000 series Instruction manual v1.1 14
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
WARNING
Radio interference and possible damage to health due to exceeding the permitted
transmission power!
The maximum permitted field strength can be exceeded when using directional
antennas with a high level of antenna gain.
•Comply with the maximum permitted signal strength (EIRP) as per the
national or local regulations (see calculation example for EIRP).
•Observe the regulations and standards which apply at the installation site
(e.g. the standards for antenna erection VDE 0855 and for lightning
protection VDE 0185-305).
•Always have the planning, installation and acceptance of antenna systems
carried out by a specialist with electro-technical qualifications.
•Per the requirements of the U.S. Federal Communications Commission
(FCC) and the Canadian ISED (Industry Canada), the antenna gain
(including power losses) must not exceed the following values when
operating in North America:
LTE
Band 2 (1850–1910 MHz) 6 dBi
Band 4 (1710–1755 MHz) 6 dBi
Band 5 (824–849 MHz) 6 dBi
Band 7 (2500–2570 MHz) 9 dBi
Band 12 (699–716 MHz) 6 dBi
Band 13 (777–787 MHz) 6 dBi
Band 25 (1850–1915 MHz) 6 dBi
Band 26 (814–849 MHz) 6 dBi
Band 30 (2305–2315 MHz) 1 dBi (external vehicle antennas not permitted!)
Band 41 (2496–2690 MHz) 9 dBi
UMTS
Band 2 (1850–1910 MHz) 6 dBi
Band 4 (1710–1755 MHz) 6 dBi
Band 5 (824–849 MHz) 6 dBi
3.9 Calculation example for the transmission power (EIRP)
EIRP = Pout - Closs + Antgain = 22 dBm - 8 dB + 9 dBi = 23 dBm (≙200 mW)
EIRP = Equivalent Isotropically Radiated Power
Pout = Transmission power of the wireless card (see data sheet of the device)
Closs = Losses caused by attenuation in coaxial cables and connectors
Antgain = Antenna gain

IRF3000 series Instruction manual v1.1 15
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
3.10 Notes on using the device according to UL approval
For devices with a UL marking on the type plate, the following applies:
•Indoor use only!
•The communication cables may only be installed inside a building or a maximum of 42.7 m (140
feet) outside buildings.
•The device contains an internal fuse at the voltage input. This fuse and all other internal
components must not be replaced by service personnel, but only by the manufacturer.

IRF3000 series Instruction manual v1.1 16
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
4 Introduction
The industrial firewall forms the link between the IT world and the automation system and meets the
requirements of IT security as well as of the maintenance personnel in the production facility. It allows
the network as well as access to this network to be monitored. A fundamental protective mechanism is
situation-dependent and physical network disconnection. It additionally provides safe access for service
purposes.
4.1 Equipment versions
Variant Ethernet
connections
(1000 Mbit/s)
4G/LTE
(optional)
GPS
(GNSS)
Digital I/Os
IRF34x1 4 x RJ45 EU or
EMEA/US
- 2 I / 1 O
IRF38x1 8 x RJ45 x 5 I / 4 O
4.2 Event log
If the firewall is not disconnected from the power supply, an event log saves all events. The event log
can be read out both locally and via a central syslog server.
4.3 Mobile radio modem (optional)
The integrated LTE modem enables mobile radio connections.
4.4 Scope of delivery
Please check that the contents of the package are complete and that they are free of damage:
Scope of delivery
1 x Industrial router and firewall, type IRF3xxx
1 x 4-pin plug for power supply
1 x 3-pin plug for Modbus RTU
1 x 4-pin plug (grey) for digital I/Os #2
Only with IRF38: 1 x 8-pin plug for digital I/Os #3…5
1 x Quick-start guide
Optional: 2 x Mobile communications antenna
Optional accessory: 1 x VESA mounting plate

IRF3000 series Instruction manual v1.1 17
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
4.5 Environmental conditions
The device can be put into operation and used under the following conditions. Failure to observe any
one of these conditions will invalidate the warranty of the device. ADS-TEC cannot be held liable for any
damages arising from improper use and handling. See also chapter 8 Technical data.
Ambient temperature
in operation -30 … +70°C
for storage -40 … +85°C
Humidity
in operation 5 … 90 %, without condensation
for storage 5 … 90%, without condensation

IRF3000 series Instruction manual v1.1 18
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
5 Installation
5.1 External device dimensions IRF34x1

IRF3000 series Instruction manual v1.1 19
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
5.2 External device dimensions IRF38x1

IRF3000 series Instruction manual v1.1 20
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str.1 • 72622 Nürtingen • Germany
5.3 Top-hat rail mounting
1. Position the IRF on the top-hat rail from below at an angle (1).
2. Pull the top-hat rail locking mechanism (2) upwards using a screwdriver, push the device onto the
upper side of the top-hat rail and remove the screwdriver.
3. The top-hat rail locking mechanism springs back to its original position.
4. Check that the IRF is seated securely on the top-hat rail.
To release the device from the top-hat rail, proceed in the reverse order.
When removing, take care not to damage the top-hat rail adapter of the device.
5.4 Optional accessory: Attaching the VESA holder
Screw the mounting plate directly onto the device label using the screws provided. The positions of the
screw holes are marked with target crosses ( ) on the label.
⌖
Table of contents
Other ADS-tec Network Router manuals