SECTION 1 –General Information.............................................. 1–1
About the 6270ADT......................................................................... 1–1
System Features .............................................................................. 1–1
Security......................................................................................... 1–1
Setup............................................................................................. 1–1
Compatibility ................................................................................... 1–2
ECP Error......................................................................................... 1–2
SECTION 2 –Mounting and Wiring ............................................ 2–1
Mounting the 6270ADT................................................................... 2–1
Wiring the 6270ADT ....................................................................... 2–2
SECTION 3 –Front Panel LEDs and Buttons........................... 3–1
Front Panel LEDs............................................................................ 3–1
Front Panel Buttons ........................................................................ 3–2
SECTION 4 –Initial Setup............................................................. 4–1
Programming the Control Panel..................................................... 4–1
6270ADT Initialization.................................................................... 4–2
Power Up ...................................................................................... 4–2
How to Change the ECP Address ................................................... 4–2
How to Access the Central Station Screen..................................... 4–3
How to Select System Options .................................................... 4–6
How to Set the NIGHT Setup Button Function......................... 4–7
How to View and Edit Screen Security....................................... 4–8
How to View the Panel Configuration ........................................ 4–9
6270ADT Setup.............................................................................. 4–10
How to Adjust the Touch Screen Contrast ............................... 4–11
How to Adjust the Volume......................................................... 4–12
How to Select Screen Saver Activation Time........................... 4–13
How to Set the Time and Date.................................................. 4–14
Setting Chime Mode On/Off.......................................................... 4–15
SECTION 5 –User Codes................................................................ 5–1
Introduction to User Code Setup .................................................... 5–1
How to Access User Setup............................................................... 5–1
How to Add a User ....................................................................... 5–3
How to Delete a User................................................................... 5–5
How to Edit a User....................................................................... 5–6
SECTION 6 –Maintenance ............................................................ 6–1
About 6270ADT Maintenance......................................................... 6–1

iv
How to Clean the 6270ADT ............................................................ 6–1
Routine Care .................................................................................... 6–3
SECTION 7 –Troubleshooting...................................................... 7–1
Troubleshooting ............................................................................... 7–1
Diagnostics....................................................................................... 7–1
About Diagnostics ........................................................................ 7–1
How to Access the Diagnostics .................................................... 7–1
Performing Diagnostics................................................................... 7–3
LCD Display Test......................................................................... 7–3
Audio Test..................................................................................... 7–6
LED Test....................................................................................... 7–7
SECTION 8 –Specifications .......................................................... 8–1
Specifications ................................................................................... 8–1
SECTION 9 –Index.......................................................................... 9–1

v
Conventions Used in This Manual
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Before you begin using this manual, it is important that you
understand the meaning of the following symbols (icons) and text
note.
ULThese notes include specific information that must be followed if you are
installing this system for a UL Listed application.
These notes include information that you should be aware of before
continuing with the installation, and which, if not observed, could result
in operational difficulties.
Note: These text notes are provided throughout the manual to provide
informative information and shortcut tips for the installer.

vi

1–1
SECTION 1
General Information
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦
About the 6270ADT
♦
System Features
♦Compatibility
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
About the 6270ADT
The 6270ADT is an intuitive, graphical touch-screen keypad that
combines security and home control. The 6270ADT can be used for:
x
Quick and easy security system operation
x
Messages
x
Control of the home environment, including lights and contains
provisions for the future control of heating and air-conditioning.
ULThe home environment control feature has not been evaluated by UL.
System Features
Security
x
Arm System
–Away
–Stay
–Night
x
Disarm System
x
User Codes - Allows authorized user to add or delete codes
x
Bypass Zones
Setup
x
Volume
x
Contrast

6270ADT Installation and Setup Guide
1–2
x
Diagnostics
x
Keypad Emulation
Compatibility
The below listing identifies the alarm systems that the 6270ADT can
interface with, the maximum number of 6270ADTs that can be used
with each system, and the minimum alarm panel software revision
level for compatibility.
MAXIMUM NUMBER MINIMUM SOFTWARE
ALARM SYSTEM OF 6270ADTs REVISION LEVEL
Safewatch Pro 3000EN 2 All Levels
VISTA-128BPADT 3 2.4
VISTA-250FBPADT 1 1.5
VISTA-15P 2 3 (When available)
VISTA-20P 2 3 (When available)
VISTA-20PS 2 All Levels
VISTA-128BP 3 2.4
VISTA-128FBP 3 1.6
VISTA-250BP 3 2.4
VISTA-250FBP 1 1.5
On all panels except the residential panels, you may obtain the software
revision level of the alarm panel by entering the program mode and then
entering #92 on the keypad. The second line of the keypad displays the
software revision level (without the decimal point).
ECP Error
The message “ECP Error”will be displayed at the top of the screen (except for
the Home screen) when the 6270ADT cannot communicate with the alarm
panel. This may be caused by and incorrect ECP address in the 6270ADT or
because AUI type devices have not been enabled in the panel. While this
message is being displayed, you must use the 6270ADT default code of “4140”
any time the 6270ADT requests an authorized code.

2–1
SECTION 2
Mounting and Wiring
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦
Mounting the 6270ADT
♦
Wiring the 6270ADT
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Mounting the 6270ADT
The 6270ADT should be mounted using the following criteria:
x
The 6270ADT must be mounted indoors, and
x
should be mounted at eye level for easy viewing by the user.
To mount the 6270ADT, see Figure 1 and complete the following
steps:
1. Detach the case back by pushing up into the two tabs located at
the bottom of the 6270ADT with the blade of a screwdriver while
pulling the case back and case front apart.
2. Locate the case back over the mounting surface such that the
opening in the case back is aligned with the wire/cable access
opening (in the mounting surface) while passing the wires/cable
through the opening in the case back.
3. Secure the case back to the mounting surface using four screws
(supplied).
Prior to attaching the case front to the case back, be sure to wire the
6270ADT as described in the "
Wiring the 6270ADT
" paragraph in this
section.

6270ADT Installation and Setup Guide
2–2
MOUNTING
SCREWS (4)
(TYP)
WALL OR
MOUNTING
SURFACE
CASE
FRONT
CASE
BACK
6270-003-V1
ARMED
READY
MESSAGE
ARMED
HOME FUNC PANIC BACK
Figure 1. Mounting the 6270ADT
Wiring the 6270ADT
Connect 6270ADT in parallel with keypads and other peripheral
devices using the keypad data (ECP) bus. To wire, see the Summary
of Connections diagrams at the back of this guide, or the appropriate
Systems Interconnection Diagram provided, and follow the
instructions below.
UL
x
On single partition systems, at least one keypad MUST receive
power from the control panel’s auxilary power.
x
On multiple partition systems, at least one keypad in each partition
MUST receive power from the control panel’s auxilary power.
x
You may use a Listed Class 2 power supply suited for the appli-
cation to power additional keypads.
Unshielded 4-conductor cable is recommended for the power/data wire.

SECTION 2: Mounting and Wiring
2–3
Connect the wires to the 6270ADT terminal block as follows:
1. The 6270ADT has holding clips on the case back to hold the case
front while you are wiring the unit. Hang the case front on the
holding clips as shown in Figure 2.
6270-009-V1
G
Y+
WALL OR
MOUNTING
SURFACE
CASE
FRONT
CASE
BACK
Figure 2. Wiring
Preparation
2. Connect +12VDC to the 6270ADT using step a or b below.
a. If powering the keypad from the control panel, connect the
AUX + terminal of the control panel to terminal block position
2 (+12VDC terminal of the 6270ADT (red wire)).
b. If powering the keypad from a supplementary power supply,
connect the + terminal of the supplementary power supply to
terminal block position 2 (+12VDC terminal of the 6270ADT
(red wire)).

6270ADT Installation and Setup Guide
2–4
6270-002-V1
DATA OUT (YELLOW)
GROUND (BLACK)
DATA IN (GREEN)
+12VDC (RED)
G
Y+
+
+
+
+
Figure 3. Wiring the
6270ADT
3. Connect ground to the 6270ADT using step a or b below.
a. If powering the keypad from the control panel, connect the
AUX –terminal of the control panel to terminal block position
3 (GND terminal of the 6270ADT (black wire)).
b. If powering the keypad from a supplementary power supply,
connect the AUX –terminal of the control panel to the (–)
terminal of the supplementary power supply (black wire).
Then, connect the (–) terminal of the supplementary power
supply to terminal block position 3 (GND terminal of the
6270ADT (black wire)).
4. Connect Data Out terminal of the control panel to terminal block
position 1 (Data In terminal of the 6270ADT (yellow wire)).
5. Connect the Data In terminal of the control panel to header
terminal block position 4 (Data Out terminal of the 6270ADT
(green wire)).
6. Attach the case front of the 6270ADT to the case back. Attach the
top of the case first, and then press the bottom section inward
until it snaps into place securely.

3–1
SECTION 3
Front Panel LEDs and Buttons
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦
Front Panel LEDs
♦
Front Panel Buttons
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Front Panel LEDs
ARMED
READY
MESSAGE
FUNC PANIC BACK
HOME
6270-001-V1
Front Panel LEDs and Buttons

6270ADT Installation and Setup Guide
3–2
LED DESCRIPTION
ARMED ON –Security system is armed.
OFF –Security system is not armed.
READY ON –Security system is disarmed and ready to arm.
OFF –Security system is armed or disarmed but not ready. If
disarmed, faults or troubles are present.
MESSAGE FLASHING –The 6270ADT contains message(s) for the User
OFF –No messages.
Front Panel Buttons
BUTTON DESCRIPTION
HOME Used to return to the HOME screen display from any sub-
menus.
FUNC Reserved for future use.
PANIC Used to display the EMERGENCY screen (Fire or Panic signal
generation).
BACK Used to exit the current screen display and return to the prior
screen display.
▲Used to scroll through screen lists in an upward direction.
▼Used to scroll through screen lists in a downward direction.

4–1
SECTION 4
Initial Setup
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦Programming the Conrol
Panel
♦6270ADT Initialization
♦How to Change the ECP
Address
♦ How to Access the Central
Station Screen
♦6270ADT Setup
♦Setting Chime Mode On/Off
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Programming the Control Panel
The 6270ADT will not be fully operational unless its address in the
control panel has been enabled for an alpha console, AUI type device,
and assigned to a partition (where applicable). Refer to
“Compatibility”on page 1–2 of this document for the quantity of
6270ADTs that may be used and the required control panel software
revision level.
On residential control panels (Safewatch Pro 3000EN or
equivalent), two 6270ADTs may be used (addresses 1 and 2). These
addresses (in field *189) are enabled by default. If the defaults have
been changed, enable these addresses (in field *189) using an alpha-
keypad and the Data Field Programming procedures located in the
panel Installation and Setup Guide.
On commercial control panels (VISTA-128BPADT, VISTA-
250FBPADT, or equivalent), addresses between 1 through 30 may
be used for the 6270ADT. These addresses in the control panel are
normally not defaulted for AUI type devices. To enable the addresses
you will be using for 6270ADTs, use an alpha-keypad and follow the
procedures for “Device Programming”in your control panel
“Programming Guide.”

6270ADT Installation and Setup Guide
4–2
6270ADT Initialization
Power Up
When initially powered, the screen displays the boot sequence as it is
performed. After it is determined what services are available, the
screen displays the Set ECP Address screen.
SCREEN ACTION
If the system is incorporating only one
6270ADT, leave the address set to 1 and
press the OK button. The boot-up
process will continue until completion.
If there are to be additional 6270ADT units
in the system, refer to the
How to Change
the ECP Address
paragraph.
How to Change the ECP Address
After enabling addresses in the control panel using an alpha-keypad,
power up each 6270ADT one at a time, and set its address to one of
the addresses you enabled in the control panel. If this is a first time
power-up of the unit, follow the initialization procedure in this
section. Otherwise, access the Central Station screen then follow the
procedure to change the address on the unit.

SECTION 4: Initial Setup
4–3
How to Access the Central Station Screen
To Access the “Central Station”screen perform the following:
1. Press the SECURITY button on the “Home”screen. The “Arming”screen is
displayed.
SCREEN ACTION
2. Press the MORE CHOICES button.
The “More Choices”screen is displayed.
3. Press the SETUP button on the “More
Choices”screen. The “Setup”screen is
displayed.
4. Press the ADVANCED SETUP button.
The Enter Authorized Code:
authorization screen is displayed.

6270ADT Installation and Setup Guide
4–4
SCREEN ACTION
5. Enter your 4-digit Installer code. The
“Advanced Setup”menu screen is
displayed.
Note: If the top of the screen is displaying
ECP Error, the ECP address in the
6270ADT is not valid for the panel that it is
connected to. To change the ECP
address in the 6270ADT when ECP Error
is being displayed, enter the 6270ADT
default code of “4140”to advance to the
next screen.
6. Press the Central Station button. The
“Central Station”menu screen is
displayed.

SECTION 4: Initial Setup
4–5
To change the address, perform the following.
SCREEN ACTION
1. On the “Central Station”screen press
the ECP Address button. A pop-up
window is displayed with options for
selecting the 6270ADT's ECP address.
2. The available ECP addresses are:
1-2 for residential controls or
1-30 for commercial controls
Select the ECP address for this 6270ADT
using the Up/Dn arrows. Press the OK
button to accept the address setting or the
CANCEL button to maintain the original
ECP address. The 6270ADT goes to the
"Central Station" menu screen.
3. Press the "Back" button three times to
save the new address. The "More
Choices" screen is displayed.

6270ADT Installation and Setup Guide
4–6
How to Select System Options
The system options allow you to place buttons on the "Home" screen.
The SECURITY and MESSAGES buttons are always displayed and
cannot be removed. A Lighting button can also be added to the
“Home”screen. To avoid confusion to the user, only buttons whose
options are functional in the system should be displayed. To select
the system options, do the following:
SCREEN ACTION
1. On the “Central Station”screen press
the Options button. A pop-up window is
displayed with an option for selecting
Lighting.
2. Touch the Lighting button to turn the
Lighting option on or off. A checkmark
appears in the button with the Lighting
option is “ON”.
Note: DO NOT select the Demo Mode
option. This option should only be
selected if instructed to do so by factory
service. When this option is selected, the
keypad will not communicate with the
control panel and any user can select
Advanced Setup screens.