Advanced Brewing Systems KoolSource KS-1 User manual

#INNOVATIONS 4U!
(855)532-5522
INSTRUCTION MANUAL
KS-1 NITRO-GENERATOR
SINGLE NITRO & ICED COFFEE

#INNOVATIONS 4U!
(855)532-5522
Content:
Installation of KoolSource KS-1.........................................................................................................3
Dispensing taps and accessories on the Koolsource System........................................................... 4
Connections Schematic ……………………………………............................................................................. 5
Nitro and Product flow adjustmen…………………………....................................................................... 6
Coffee and Cleanout system……………….. ......................................................................................... 7
Daily Cleaning Instructions …………………..…...................................................................................... 8
Weekly Cleaning Instructions………………………………………………………………………………………………………9
Monthly Cleaning Instructions…………………………………………………………………………………………………….10
Troubleshooting……….. ……............................................................................................................. 11

#INNOVATIONS 4U!
(855)532-5522
Installation of KoolSource KS-1
Lines Connections:
Out: From Pump to
Coffee IN located in
the back
In: from RTD product
IMPORTANT:
Your RTD product
most be connected
to the pump before
the system is being
turn “ON”
Power Requirement for Machine:
Voltage: 115V/60Hz
Wattage: 575 Watts
Power for pump:
Voltage: 115v/60Hz 2 x (Nema 5-15R)
Wattage: 345 Watts
Dimensions W x H x D :
(283mm x 478mm x 495mm)
(11-1∕16’’x 18-3/4’’x 19-1/2’’
IMPORTANT:
The Cooling unit has a time delay of 2 minutes after plugging it in, make sure you give the system time to engage properly.
When compressor stops for the first time (approx. 7 minutes) → unit is ready fordispensing
WARNING:
TO AVOID ANY DAMAGE TO THE SYSTME MAKE SURE ALL
CONNECTION ARE PROPERLY CONNECTED AND SECURITY
RED CLIPS ARE INSTALLED BEFORE THE UNIT IS BEING
PURGE FOR THE FIRST TIME!
IMPORTANT:
Make sure to install the Strainer in
the appropriate orientation to avoid
any blockage or debris in the system.

#INNOVATIONS 4U!
(855)532-5522
Dispensing taps and accessories
1. NITRO/ICED & COLD BREW COFFEE Single dispensing tap
2. NITRO dispensing tap –stainless steel disc must be mount between tap and shank
3. Two beverages can be dispensed from the same tap by swithching on and off the nitro
activator
4. Filter strainer must be installed in coffee line to avoid residues in the system
5. Restrictor Disc
Dispensing Tap Dispensing Switch (Nitro & Coffee) Tap Restrictors
Filter Strainer
1
2
3
4
5
5

#INNOVATIONS 4U!
(855)532-5522
Connection Schematic
Picture 5 : Connection schematic –one type of product
1. Nitrogen Flow Regulator
2. Nitrogen Pressure regulator
3. Cleanout System
4. Nitro Pump Switch
5. Coffee Inlet 3/8’’ Quick-connect
6. Main Pump Switch
1
3
4
5
2
6

#INNOVATIONS 4U!
(855)532-5522
Nitrogen and Product Flow adjustment
The product flow adjustment is very important for the quality of your drinks
Important: Dispensing valve (D) must be Horizontal for Dispensing the product before starting
A) Nitrogen Flow adjustment:
a. Make sure the the valve is completely close at the 0 position
b. Adjust to type of mixsure you prefer
B) Nitrogen Pressure adjustment:
a. The pressure of the system is already set at the factory: Do not adjust it!
C) Nitrogen Pump Power Switch (Should be''ON'')
D) Cleanout system is located in the back left of the unit for an easy access
a. The horizontal position is the Dispense Mode
b. The vertical position is for Cleaning Mode
A
B
C
D

#INNOVATIONS 4U!
(855)532-5522
Daily Cleaning Instructions
➢Daily
✓Is very important is to keep your KoolSource System clean, the surface, around,
dispensing towers, taps and drip trays.
✓The regular maintenance planning (cleaning) is necessary to extend the life of your
system.
✓Rinse your system with water daily to maintain the lines clean by swtching the unit
to ''Cleaning Mode''.
➢Daily cleaning
Wipe down and clean all surfaces with a warm soapy water (no chlorinated cleaners)
➢Exterior surfaces of the system including beneath the unit and the drip tray
1- Clean both stouts faucet nozzles by removing and soaking with sanitizer
2–Remove and clean drip tray with water
3- Remove and rinse Filter Strainer with sanitizer
(Consulted Monthly Cleaning Instructions)
Step
1
–Clean Solution for Daily cleaning of tap handles and Drip tray
WATER
Step 2 –Sanitize Solution for Daily sanitizing of tap handles and Drip Tray
WATER
Clearly Cold
water
7.5 ml
1 liter
30 ml
4 liters
Complete Café
water
7.5 ml
1 liter
30 ml
4 liters
1
2
1
4
2
3
4
1
2
3

#INNOVATIONS 4U!
(855)532-5522
Weekly Cleaning Instructions
➢Weekly
Clean your KoolSource system by following all instruction carefully
•USE COLD WATER FOR THE CLEANING PROCESS
•Prepair cleaning products fron your 1-2 Cold Brew Kit
•Diluded 30ml of Clearly Cold Step 1 on 4 liters of
cold water.
•Diluded 30ml of Complete Café Step 2 on 4 liters of
Cold water.
To start the process set the unit to Cleaning Mode by turning the knob counter-clock located in
the back of the machine. (See Picture Cleaning Mode)
•Remove the down tubes from you RTD Product containers
•Insert them into you pre-mix Clearly Cold solution Step 1
•Open your taps to purge the lines until the cleaning solution
Starts to come out and Close Taps.
•Wait for 5 minutes, open tabs and run the solution for 30sec.
•Wait for 5 minutes, open tabs and run the soluton to the end.
•Insert now the down tube into the pre-mix Complete Café solution
•Open tabs for 30 sec. To eliminated the previous soltuion
•Wait for 5 minutes, open tabs and run the solution for 30sec.
•Wait for 5 minutes, open tabs and run the soluton to the end.
•Insert now the down tube into frech clear cold water (Cleaning Mode)
•Start the Final Rinsing, open tabs until Clear Water start coming out
•Open Tabs for 30 sec. And close them for 5-10 sec. Repeat this step until your run about
10liters of clear water.
•DO NOT FORGET TO RETURN THE KNOB TO DISPENSE MODE
•Last step of your weekly cleaning, clean the system by following instructions on your
DAILY CLEANING INSTRUCTIONS in Page 9.

#INNOVATIONS 4U!
(855)532-5522
Monthly Cleaning Instructions
➢Every month
The cleaning your KoolSource System is extremely important to prolong the performance and
life of the equipment.
•Start by following the routine of you Daily & Weekly Cleaning Instructions
•Clean inlet condenser coil located on top of the unit with vacuum cleaner or brush if
necessany.
•The maintenance of the condenser coil will eliminate overheating of your system.
FILTER STRAINER CLEANING
- Dissasemble filter strainer by truning the cap conter-clock
and wash all components with warm water 25˚C- 35˚C
Use sanitizer ( See Complete sanitize solution instructions page 9)
Filter strainer Orientation
Picture 7 : Filter strainer cleaning
3
Top view
of the unit

#INNOVATIONS 4U!
(855)532-5522
Troubleshooting Instructions
PROBLEM
CAUSE
SOLUTION
Pump runs but doesn’t
pump any product
•Air-lock
•Air leakage
•Bad installation
•Reset pump by turn it off for 2 minutes
•Clean Filter Strainer (Monthly Cleaning instructions)
•Verify all your lines from the RTD to the unit for leakage
•Make sure all the connections are properly push in
Product is not being
dispensed properly
•The lines are dirty
•Blockage on line
•General Cleaning will be necessary
•Tap nozzle disc dirty
No Nitro
•Nitro pump Switch
•Nitro Dispensing Swith
•Switch ON Nitro pump in the back of unit
•Switch Nitro dispensing swith to Nitro
•Unplug and re-start the system
No Cold Coffee
•Cold Coffee Dispensing
Switch
•Main pump Switch
•Switch the Dispensing Switch to Cold Coffee
•Turn OFF Main Pump switch for 2 minutes
No Product is being
dispensed but the pump
seems to run
•Main pump has an air-lock
•Main pump is on pretection
mode
•Dispensing Tap blocked
•Filter Strainer blocked
•Verify all line and re-connect them if needed
•Reset pump by turn it off for 2 minutes
•Make sure there's enough product inside of your RTD
container
•Clean the disc inside of the nozzle on the Tap
•Clean the Filter Strainer
System not working
•Power failure
•Make sure the units and the main pump are properly
plug to 110 volts source (System & Pump)
•Verify the braker on the electrical panel
IF NONE OF THE SOLUTIONS SOLVED THE PROBLEM, PLEASE CONTACT YOUR SERVICE PROVIDER.
Table of contents
Popular Brewing System manuals by other brands

BRAVILOR BONAMAT
BRAVILOR BONAMAT Aurora GTBSH-001 user manual

Blichmann Engineering
Blichmann Engineering Fermenator TC Blow-off kit V2 Operation, Assembly & maintenance manual

Blichmann Engineering
Blichmann Engineering Hybrid Manifold Assembly

Blichmann Engineering
Blichmann Engineering Yeast Harvester Assembly operation maintenance

Bloomfield
Bloomfield Koffe-King Wunder-Bar 8573 owner's manual

TopBrewer