Advanced Energy Thyro-PX User manual

Thyro‑PX® DC Power Controller
User Manual
June 2021 57010241-00B

COPYRIGHT
This manual and the information contained herein are the proprietary property of
Advanced Energy Industries, Inc.
No part of this manual may be reproduced or copied without the express written
permission of Advanced Energy Industries, Inc. Any unauthorized use of this manual
or its contents is strictly prohibited. Copyright © 2020-2021 Advanced Energy
Industries, Inc. All Rights Reserved.
DISCLAIMER AND LIMITATION OF LIABILITY
The information contained in this manual is subject to change by Advanced Energy
Industries, Inc. without prior notice. Advanced Energy Industries, Inc. makes no
warranty of any kind whatsoever, either expressed or implied, with respect to the
information contained herein. Advanced Energy Industries, Inc. shall not be liable in
damages, of whatever kind, as a result of the reliance on or use of the information
contained herein.
PRODUCT USAGE STATEMENT
WARNING:
Read this entire manual and all other publications pertaining to the work
to be performed before you install, operate, or maintain this equipment.
Practice all plant and product safety instructions and precautions. Failure
to follow instructions can cause personal injury and/or property damage. If
the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment might be impaired. All personnel who
work with or who are exposed to this equipment must take precautions to
protect themselves against serious or possibly fatal bodily injury.
Advanced Energy Industries, Inc. (AE) provides information on its products
and associated hazards, but it assumes no responsibility for the after-sale
operation of the equipment or the safety practices of the owner or user.
NEVER DEFEAT INTERLOCKS OR GROUNDS.
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B ii

AVERTISSEMENT:
Lire ce manuel au complet ainsi que toutes les autres publications portant
sur le travail à effectuer avant d’installer, d’utiliser ou d’entretenir cet
équipement. Suivre toutes les consignes de sécurité et appliquer toutes
les mesures de précautions de l'usine et du produit. Ne pas suivre ces
consignes peut entraîner des blessures corporelles et/ou des dommages
matériels. Si l’équipement est utilisé de manière non spécifiée par le
fabricant, la protection fournie par l’équipement peut être compromise. Tous
les membres du personnel travaillant sur cet équipement ou qui y sont
exposés doivent prendre des mesures de précaution pour se protéger contre
des blessures graves, voire mortelles.
Advanced Energy Industries, Inc. (AE) fournit des renseignements sur
ses produits et les dangers qui y sont liés, mais elle ne peut être
tenue responsable du fonctionnement après-vente de l’équipement ou des
pratiques de sécurité du propriétaire ou de l’utilisateur. NE JAMAIS METTRE
EN ÉCHEC OU CONTOURNER LES DISPOSITIFS DE PROTECTION DE
VERROUILLAGE OU DE MISE À LA TERRE.
TRADEMARKS
All Advanced Energy trademarks are the property of Advanced Energy
Industries, Inc. For the list of Advanced Energy trademarks, visit: https://
www.advancedenergy.com/legal/. Any unauthorized use of Advanced Energy
trademarks is prohibited.
All other trademarks are the property of their respective owners.
CUSTOMER FEEDBACK
Advanced Energy’s technical writing staff has carefully developed this manual using
research-based document design principles. However, improvement is ongoing, and
the writing staff welcomes and appreciates customer feedback. Please send any
comments on the content, organization, or format of this user manual to:
To order a manual, please contact Technical Support:
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B iii

Table of Contents
Chapter 1. Safety and Product Compliance Guidelines
Important Safety Information ................................................................................. 1-1
Danger, Warning, and Caution Boxes ................................................................... 1-1
Safety Guidelines .................................................................................................. 1-2
Rules for Safe Installation and Operation ....................................................... 1-2
Interpreting Product Labels ................................................................................... 1-2
Product Compliance .............................................................................................. 1-4
Product Certification ................................................................................ ....... 1-4
Safety and EMC Directives and Standards ............................................. ....... 1-5
Conditions of Use .................................................................................... ....... 1-5
Environmental Compliance ............................................................................. 1-5
Interlocks and Limiting Conditions ................................................................. ....... 1-6
Chapter 2. Product Overview
General Description ....................................................................................... ....... 2-1
Unit Features ......................................................................................................... 2-1
Chapter 3. Specifications
Physical Specifications .......................................................................................... 3-1
Electrical Specifications ................................................................................. ....... 3-2
Cooling Specifications ........................................................................................... 3-4
Environmental Specifications ................................................................................ 3-5
Type Designation ........................................................................................... ....... 3-6
Chapter 4. Communication Controls
Controls and Indicators .................................................................................. ....... 4-1
Status Indicators (LEDs) ................................................................................. 4-2
Relay Indicators .............................................................................................. 4-4
Analog and Digital I/O .................................................................................... ....... 4-4
Module Slots .................................................................................................. ..... 4-10
Thyro‑Touch Display ........................................................................................... 4-11
Thyro‑Touch Display Menus ......................................................................... 4-13
Accessing the Main Menu ....................................................................... ..... 4-13
Software User Interface ................................................................................. ..... 4-13
Using the Software .................................................................................. ..... 4-14
Installation .............................................................................................. 4-14
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B ivTable of Contents

Chapter 5. Installation, Setup, and Operation
Preparing to Install the Unit ................................................................................... 5-1
Spacing Requirements ............................................................................ ....... 5-1
Dimensional Drawings .................................................................................... 5-1
Installation Requirements ............................................................................... 5-2
Unpacking the Unit .................................................................................. ....... 5-3
Lifting the Unit ................................................................................................. 5-3
Installing the Unit ................................................................................................... 5-4
Installing Optional Modules ..................................................................... ....... 5-4
Mounting the Unit .................................................................................... ....... 5-5
Grounding ....................................................................................................... 5-6
Connecting I/O and Auxiliary Connectors ....................................................... 5-6
Connecting Load and Auxiliary Power ............................................................ 5-7
Connection Diagrams ..................................................................................... 5-8
First Time Operation ...................................................................................... ..... 5-13
Normal Operation ................................................................................................ 5-13
Setpoint Control ............................................................................................. ..... 5-14
Monitoring ...................................................................................................... ..... 5-15
Minimum and Maximum Monitoring .............................................................. 5-15
Fuse Monitoring ............................................................................................ 5-16
Mains Voltage Monitoring ............................................................................. 5-16
B12C and B18C Operation ............................................................................ ..... 5-16
Connection .............................................................................................. ..... 5-17
Control Wiring ............................................................................................... 5-18
Configuring for B12C and B18C Operation ............................................. ..... 5-18
Maintenance ........................................................................................................ 5-21
Fan Maintenance .......................................................................................... 5-21
Chapter 6. Troubleshooting and Global Services
Troubleshooting Checklist ..................................................................................... 6-1
AE Global Services ........................................................................................ ....... 6-2
Primary Contact Information ........................................................................... 6-3
Alternate Contact Information ......................................................................... 6-3
Returning Units for Repair ..................................................................................... 6-3
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B vTable of Contents

List of Tables
Table 1-1. Interlocks and limiting conditions .................................................. ....... 1-7
Table 3-1. Physical specifications ......................................................................... 3-1
Table 3-2. Electrical specifications ........................................................................ 3-2
Table 3-3. Type voltage 500 volts ......................................................................... 3-3
Table 3-4. Type voltage 690 volts ........................................................................ 3-3
Table 3-5. Current derating ................................................................................... 3-4
Table 3-6. Fan current, air volume, and sound pressure ............................... ....... 3-4
Table 3-7. Environmental standard specifications ........................................ ....... 3-5
Table 3-8. Climatic specifications ......................................................................... 3-5
Table 3-9. Type designation .................................................................................. 3-6
Table 4-1. Thyro-PX DC status LEDs ............................................................ ....... 4-3
Table 4-2. Relay indications .................................................................................. 4-4
Table 4-3. 9-pin digital I/O connector (X51) ................................................... ....... 4-6
Table 4-4. 9-pin analog I/O connector (X52) ......................................................... 4-7
Table 4-5. 16-pin analog/digital I/O connector (X53 or X54) ................................. 4-7
Table 4-6. 16-pin digital I/O connector (X53 or X54) ............................................. 4-7
Table 4-7. Relay K1, K2, and K3 connectors (X21, X22, X23) ...................... ....... 4-9
Table 4-8. AC auxiliary power supply input (X1) ................................................... 4-9
Table 4-9. DC auxiliary power supply input (X3) ................................................. 4-10
Table 5-1. Terminal screw size ...................................................................... ....... 5-8
Table 5-2. Terminal screw torque .................................................................. ....... 5-8
Table 5-3. Setpoint characteristics ...................................................................... 5-14
Table 5-4. Minimum and maximum conditions .................................................... 5-16
Table 6-1. Using LED states for troubleshooting ........................................... ....... 6-2
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B viList of Tables

List of Figures
Figure 3-1. Current derating .................................................................................. 3-4
Figure 4-1. Total setpoint ............................................................................... ....... 4-2
Figure 4-2. Status LEDs ........................................................................................ 4-3
Figure 4-3. Front I/O connectors ........................................................................... 4-6
Figure 4-4. Bottom I/O connectors ........................................................................ 4-9
Figure 4-5. Module slots ...................................................................................... 4-11
Figure 4-6. Thyro‑Touch display ................................................................... ..... 4-12
Figure 4-7. Connection to local installed server .................................................. 4-14
Figure 5-1. Thyro-PX DC 3PX 500-1000 HF DC, 1250 HF DC, 1800 HF
DC, Thyro-PX DC 3PX 690-1000 HF DC, 1700 HF DC ...................................... 5-2
Figure 5-2. Anybus module removal .............................................................. ....... 5-5
Figure 5-3. I/O module removal ..................................................................... ....... 5-5
Figure 5-4. 3PXDC 1000A_1250A power controller connections .................. ..... 5-10
Figure 5-5. 3PXDC 1700A...1800A power controller connections ................. ..... 5-11
Figure 5-6. 3PXDC snubber connections ............................................................ 5-12
Figure 5-7. Total setpoint ............................................................................... ..... 5-14
Figure 5-8. Control characteristics for U control .................................................. 5-15
Figure 5-9. B12C vector group ............................................................................ 5-17
Figure 5-10. B18C vector group .......................................................................... 5-17
Figure 5-11. Shield clamp .............................................................................. ..... 5-18
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B viiList of Figures

Safety and Product Compliance
Guidelines
IMPORTANT SAFETY INFORMATION
To ensure safe installation and operation of the Advanced Energy Thyro-PX DC unit,
read and understand this manual before attempting to install and operate this unit. At
a minimum, read and follow the safety guidelines, instructions, and practices.
DANGER, WARNING, AND CAUTION BOXES
This symbol represents important notes concerning potential harm to people, this
unit, or associated equipment. Advanced Energy includes this symbol in danger,
warning, and caution boxes to identify specific levels of hazard seriousness.
DANGER:
DANGER indicates an imminently hazardous situation that, if not avoided,
will result in death or serious injury. DANGER is limited to the most extreme
situations.
DANGER:
DANGER indique une situation dangereuse imminente qui, si elle n’est pas
évitée, pourrait provoquer la mort ou des blessures graves. DANGER est
réservé aux situations les plus extrêmes.
WARNING:
WARNING indicates a potentially hazardous situation that, if not avoided,
could result in death or serious injury, and/or property damage.
AVERTISSEMENT:
AVERTISSEMENT indique une situation potentiellement dangereuse qui, si
elle n’est pas évitée, pourrait provoquer la mort ou des blessures graves
et/ou des dommages matériels.
Thyro‑PX® DC Power Controller Chapter
1
57010241-00B Safety and Product Compliance Guidelines 1‑1

CAUTION:
CAUTION indicates a potentially hazardous situation that, if not avoided,
could result in minor or moderate injury, and/or property damage. CAUTION
is also used for property-damage-only accidents.
ATTENTION:
ATTENTION indique une situation potentiellement dangereuse qui, si elle
n’est pas évitée, pourrait provoquer des blessures mineures ou modérées
et/ou des dommages matériels. ATTENTION est également utilisé pour des
accidents causant uniquement des dommages matériels.
SAFETY GUIDELINES
Review the following information before attempting to install and operate the
product.
Rules for Safe Installation and Operation
Please note the following rules:
• Do not attempt to install or operate this equipment without proper training.
• Ensure that this unit is properly grounded.
• Ensure that all cables are properly connected.
• Verify that input voltage and current source capacity are within specifications
before turning on the unit.
• Use proper electrostatic discharge (ESD) precautions.
• Maintenance and service must be performed only by AE-trained service
personnel.
INTERPRETING PRODUCT LABELS
The following labels might appear on your unit:
Capacitor discharge warning (5 minutes)
CE label
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑2

or
Complies with applicable European
directives.
Protective conductor terminal
This terminal must be connected first
and be of proper type and size for
the circuit with the highest voltage
and current carrying capacity. Note that
other connections might have higher
requirements than that of the mains
connection.
On or off
or Phase
Power on/standby
Hazardous voltage
Hazardous voltage
Voltage > 30 VRMS, 42.4 V peak, or
60 VDC
Hot surface
No user-serviceable parts
European Union RoHS compliant
Refer to manual for more information
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑3

Short-circuit protected
Environmentally Friendly Use Period
of 25 years per China RoHS—recycle
responsibly at end of life
Electrocution hazard
Heavy object—can cause muscle strain
or back injury
Heavy object—do not lift manually
Electrical fuse
Alternating current
Direct current
UL® Listed to Canadian and United
States safety standards
UL Listed to United States safety
standards
UL Recognized to Canadian and United
States safety standards
UL Recognized to United States safety
standards
PRODUCT COMPLIANCE
The following sections include information about unit compliance and certification,
including the conditions of use required to be in compliance with the standards and
directives.
Product Certification
Certain options of this product may be certified according to the list below.
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑4

For more information, refer to the Certificate or Letter of Conformity (US) or
Declaration of Conformity (EU), available on request.
• CE Marking – Self-declaration, assessed by AE Corporate Compliance
• EMC measurements – Verified by AE Corporate Compliance
• UL registration file E135074 according to UL 508
Safety and EMC Directives and Standards
For information concerning compliance to applicable EU requirements, refer to the
EU Declaration of Conformity for this unit. The Declaration of Conformity might
also include a supplementary section covering compliance to non-EU regulatory
requirements and/or industry standards or guidelines.
Conditions of Use
To comply with the stated directives and standards, you must meet the following
conditions of use:
• Before making any other connection to this product, connect the primary
Protective Earth (ground), and secondary Protective Earth (ground) if
applicable, to a local earth ground using wire that is sized according to the
applicable requirements.
• Install and operate this unit in an overvoltage category according to
environmental specifications.
• You must install and operate this unit with a circuit breaker on the AC input.
The circuit breaker must be easily accessible and near the unit. The circuit
breaker must be marked as the disconnecting device for the equipment.
• Use only a shielded cable for communications and/or control connections.
• Limit the system load current to the maximum specified level for the unit.
• Dispose of this product as directed by applicable laws and regulations.
• For the input and output power connections, use wires that are suitable for at
least 75°C (167°F).
• Do not allow condensation of any liquids or accumulation of conductive dust on
the instrument. Doing so will have unpredictable results, possibly including, but
not limited to, loss of accuracy.
Environmental Compliance
•EU RoHS – European Union Directive 2011/65/EU (RoHS 2)
Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment
This product is EU 2011/65/EU (RoHS 2) compliant, designed to contain
no more than the maximum concentration of hazardous substances listed in
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑5

Annex II, with possible exemptions from Annex III or IV. Because this product
is installed as a component in a large-scale fixed installation or stationary
industrial tool: the product is outside the scope of this Directive, compliance is
not required, and the EU RoHS Directive is not declared on the CE Declaration
of Conformity.
European Delegated Directive (EU) 2015/863 (RoHS 3) – Amendment
to Annex II of Directive 2011/65/EU (RoHS 2) Regarding the List of
Restricted Substances
This product is also compliant to the 2015/863 amendment, containing no
more than the maximum concentration of four additional hazardous substances
(phthalates) listed in amended Annex II.
•EU REACH – European Union Regulation (EC) No. 1907/2006
Registration, Evaluation, Authorization and Restriction of Chemicals
Advanced Energy manufactures articles subject to Article 33 of REACH
and, upon request, will provide information regarding Substances of Very
High Concern (SVHC) currently identified by the European Chemical Agency
(ECHA) that are contained in this product, at concentrations greater than 0.1%
by weight.
•China RoHS – People’s Republic of China (PRC) Ministry of Industry and
Information Technology (MIIT) Order #32 (China RoHS 2)
Management Methods for the Restriction of the Use of Hazardous Substances
Electrical and Electronic Products
This product contains hazardous substances listed in PRC Standard GB/T
26572, above the maximum concentration limits stipulated. In compliance to
PRC Standard SJ/T 11364, AE provides a disclosure of hazardous substance
content and this product is marked with an Environmentally Friendly Use
Period (EFUP) of 25 years.
INTERLOCKS AND LIMITING CONDITIONS
WARNING:
Advanced Energy products only include interlocks when required by product
specification. Interlocks in Advanced Energy products are not intended to
meet or satisfy safety requirements. Where interlocks exist, you must still
meet and satisfy safety requirements. The presence of interlocks does not
imply operator protection.
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑6

AVERTISSEMENT:
Les produits Advanced Energy comprennent des dispositifs de verrouillage
uniquement si la spécification du produit l’exige. Les dispositifs de
verrouillage d’Advanced Energy ne sont pas destinés à satisfaire aux normes
de sécurité ni à s’y conformer. Lorsqu’un système comprend un dispositif
de verrouillage, vous demeurez responsable de satisfaire aux normes de
sécurité et de vous y conformer. La présence d’un dispositif de verrouillage
n’implique pas la protection de l’opérateur.
Table 1‑1. Interlocks and limiting conditions
Mechanism Detection Method Equipment Condition When
Interlock is Open
By opening the PULSE LOCK
jumper the unit is locked.
Opening the PULSE LOCK
jumper or external interlock
circuit
Terminal X51.2 connected to
terminal X51.3
The red PULSE LOCK LED
is lit on the front panel. The
output is disabled.
The interlock jumper can be removed and replaced with an external interlock circuit
capable of switching 24 V, 20 mA.
☞ Important
By default, the unit is configured to require a customer supplied PULSE LOCK
jumper. The unit may be customer configured to not require this jumper.
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Safety and Product Compliance Guidelines 1‑7

Product Overview
GENERAL DESCRIPTION
The Thyro-PX DC is a communication-enabled SCR power controller rectifier in
a 6-pulse (B6C) configuration. Due to its modular design, multiple units can be
combined to create a 12-pulse (B12C) or an 18-pulse (B18C) rectifier system. The
unit can be installed where DC voltages, currents, or power must be controlled
precisely. Several modes of operation and control, good coupling ability to process
and automation technology, high control precision by application of a 32-bit
processor, and simple handling ensure that the Thyro-PX DC power controller is
suitable for high current DC applications.
The Thyro-PX DC power controller is suitable for the following applications:
• Direct supply of resistive loads
• Rectifier systems consisting of up to 3 B6C stacks to create an 18 pulse system
(B18C)
Due to the use of high quality thyristors, the Thyro-PX DC power controller has a
type range of up to 1800 A, and the nominal design loads can reach up to ~1.5 MW at
950 VDC.
UNIT FEATURES
The Thyro-PX DC unit offers several features for improved handling and operation:
• Ease of use
◦ Thyro‑Touch display (optional)
◦ Thyro-Tool Pro computer user interface (optional)
• Wide application range
◦ 184 V to 690 V mains voltage
◦ 3-phase units
◦ Resistive and inductive loads
◦ External 90 VAC to 250 VAC or 24 VDC auxiliary power supply input
• Useful features
◦ Soft start function
◦ Load circuit monitoring
◦ Automatic rotating field recognition
Thyro‑PX® DC Power Controller Chapter
2
57010241-00B Product Overview 2‑1

◦U, U2, I, I2, and P control
◦ Operating mode VAR
• Flexible connectivity
◦ Standard USB interface
◦ Standard analog and digital I/O
◦ Optional analog and digital I/O extension modules
◦ I/O bus for future extension options
◦Optional Anybus® system interface modules
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Product Overview 2‑2

Specifications
PHYSICAL SPECIFICATIONS
Table 3‑1. Physical specifications
Description Specification
General Physical Specifications
Size
(WxHxD)
683 mm (26.9″) x 787 mm (31.0″) x 521 mm (20.5″)
Dimensional drawing Figure 5‑1
Weight 94 kg to 110 kg (207.2 lb to 242.5 lb)
Mounting
Mechanical Mounting hardware not included
Connectors
AC auxiliary power supply
input (X1)
Included 3-pin plug-in screw terminal block, 0.2 mm2 -
2.5 mm2 (24 AWG - 12 AWG)
RS-232 (powered) (X10) 9-pin subminiature-D socket (for Thyro‑Touch display
connection)
Anybus module (optional) Varies by Anybus module, according to the bus standard (not
included)
dASM module (optional) 2 RJ-45 sockets (connectors and cables not included)
USB (X6) μ USB (connector and cable not included)
Analog I/O 1 (X51) Included 9-pin, plug-in, screw terminal block, 30 AWG -
14 AWG
Analog and digital I/O 2
(X52)
Included 9-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Analog and digital I/O 3
(optional) (X53)
Included 16-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Analog and digital I/O 4
(optional) (X54)
Included 16-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
I/O Bus (X4) RJ-45 (connector and cable not included)
24 V DC auxiliary power
supply input (X3)
Included 2-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Relay K1 (X21)Included 3-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Thyro‑PX® DC Power Controller Chapter
3
57010241-00B Specifications 3‑1

Table 3‑1. Physical specifications (Continued)
Description Specification
Relay K2 (X22)Included 3-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Relay K3 (X23)Included 3-pin, plug-in, screw terminal block, 0.14 mm2 -
1.5 mm2 (30 AWG - 14 AWG)
Protection
Degree of protection IP10B
The unit meets IP20 safety of persons requirements, but not the
IP20 safety of device requirements.
ELECTRICAL SPECIFICATIONS
Table 3‑2. Electrical specifications
Description Specification
Electrical Requirements
AC input line voltage Type voltage 500 V units: 184 V to 550 V
Type voltage 690 V units: 400 V to 759 V
Auxiliary power supply
input voltage
90 VAC - 250 VAC (230 V, 150 mA), or 24 VDC at 1 A
Fan input voltage (type
HF models)
230 V, 50/60 Hz, for fan current and current derating see “Cooling
Specifications” on page 3‑4
AC line frequency 50/60 Hz nominal; 45 Hz to 65 Hz range
AC current
Type voltage 500 V units, see Table 3‑3
Type voltage 690 V units, see Table 3‑4
Rated power
Dissipation
Current transformer ratio
Burden resistor
Semiconductor fuse
Ground connection Chassis ground near AC connector suitable for ring lug connection
Clamp for grounding the control cable shields
Load description Resistive load (minimum 100 W)
Analog inputs 0(4) mA - 20 mA Ri = ca. 250 Ω / max. 24 mA. Max open-circuit
voltage = 24 V
0(1) V - 5 V Ri = ca. 6.6 kΩ / max. 12 V
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Specifications 3‑2

Table 3‑2. Electrical specifications (Continued)
Description Specification
0(2) V - 10 V Ri = ca. 11.1 kΩ / max. 12 V
Analog outputs Signal level 0 V - 10 V, 0 mA - 20 mA or 4 mA - 20 mA. The
maximum burden voltage is 10 V. Short-circuit proof.
Precision U-control: Better than ± 0.5%
I-control: Better than ± 0.5%
P-control: Better than ± 1%
All specifications are relating to the respective final value.
Limitations Voltage limitation Urms
Current limitation Irms = default setting
Effective power limitation P
Peak current limitation, MOSI starting mode
Relays Rated current: 6 A
Rated voltage: 277 VAC, 24 VDC
General use
Contact material: AgNi+Au
Table 3‑3. Type voltage 500 volts
Model
Type Current
(A)
Type Power
(kW)
Dissipation
(W)
Current
Transformer
T1
Burden
R (Ω)
Fuse F1
(A)
1000 HF 675 3330 1000/1 1.00 2x700
1250 HF 844 4370 1000/1 1.00 2x1000
1800 HF 1215 5335 1500/1 1.00 4x900
Table 3‑4. Type voltage 690 volts
Model
Type Current
(A)
Type Power
(kW)
Dissipation
(W)
Current
Transformer
T1
Burden
R (Ω)
Fuse F1
(A)
1000 HF 950 4500 1000/1 1.00 2x1000
1700 HF 1600 5000 1500/1 1.00 4x900
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Specifications 3‑3

COOLING SPECIFICATIONS
The Thyro-PX DC power controllers are type HF units and are force cooled. The
fan in HF units require a separate power source at 230 V, 50/60 Hz. A 115 V fan is
available by special-order for some units.
Table 3‑5. Current derating
Air Temperature I/IRATED CURRENT (A)
Forced Cooling
0°C to +25°C (32°F to 77°F) 1.10
30°C (86°F) 1.05
35°C (95°F) 1.00
40°C (104°F) 0.96
45°C (113°F) 0.91
50°C (122°F) 0.87
55°C (131°F) 0.81
Rating
Forced cooling
Temperature (°C)
Figure 3‑1. Current derating
Table 3‑6. Fan current, air volume, and sound pressure
Model Current (A) Air Volume
(m3/h)
Sound Pressure
(dbA @ 1 m)
50 Hz 60 Hz
1000 HF, 1250 HF, 1700
HF, 1800 HF
1.00 1.20 1600 81
Advanced Energy®Thyro‑PX® DC Power Controller
57010241-00B Specifications 3‑4
Other manuals for Thyro-PX
1
Table of contents
Other Advanced Energy Controllers manuals
Popular Controllers manuals by other brands

Linear Technology
Linear Technology LT8391EFE Demo Manual

Volt Polska
Volt Polska AVR PRO 1000 product manual

Generac Power Systems
Generac Power Systems PowerManager PM-GC manual

AMERITRON
AMERITRON SDC-102 instruction manual

Morningstar
Morningstar TriStar TS-MPPT-30 Installation and operation manual

Geovent
Geovent PowerSmart II user manual

Resol
Resol DeltaSol AL E Operator's manual

Advanced Illumination
Advanced Illumination DCS-400E user guide

thomann
thomann Botex LED Stripe All-in-One Control user manual

Jedia
Jedia JMA-5104 operating instructions

Stober
Stober SC6 Series Commissioning instructions

IMI SENSORS
IMI SENSORS 683A111001 Installation and operating manual