device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number Maximum
Nodes Description
15 Z-Wave Plus Lifeline.When the load state of Nano Switch (on/off) is changed, the Hail CC, Switch
Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes
in this group.
25Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the
Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller.
35 Send Basic Set (configured by parameter 82) to the associated nodes in Group 3 when the external
switch S1 is operated
45 Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external
switch S2 is operated
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 3: Current Overload Protection.
Over current protection. Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A)
Size: 1 Byte, Default Value: 1
Setting Description
0Disable
1Enable
Parameter 4: Overheat protection.
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100°C.
Size: 1 Byte, Default Value: 0
Setting Description
0Disable
1Enable
Parameter 20: Configure the output status after re-power on it.
Configure the output status after re-power on it.
Size: 1 Byte, Default Value: 0