AerAtron E502 User manual

AerAtron
Ceiling fans
UserManual&TechnicalSpecifications
Models:e502&e503
Australianedition2011

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
2
Instructions.....................................................................................................................................................3
Generalprecautions ...........................................................................................................................................3
Locationandinstallationrequirementsforyourfan..........................................................................................3
Mechanicalissues...............................................................................................................................................4
Electricalissues...................................................................................................................................................4
Unpackingyourfan....................................................................................................................................5
Checkingceilingconditionandpreparingforfaninstallation .........................................6
InstallingRemoteControlReceiverintohangerbracket ...................................................................................7
PreparingFanMotorHousing ............................................................................................................................8
AttachingFanMotorHousingtoMotorAssembly.................................................................9
ClosingScrewCover ..................................................................................................................................9
FanBladesandMiddlePieceAssembly.......................................................................................10
e502..................................................................................................................................................................10
e503..................................................................................................................................................................11
FanBladestoShaftAssembly............................................................................................................12
RemoteControlSet‐up..........................................................................................................................13
Codematchyourtransmitterandreceiver ......................................................................................................13
CodematchforTransmitter(Handheld)andReceiver....................................................................................13
Technicalspecifications.........................................................................................................................14
e503ande502 ..................................................................................................................................................14
SlopedCeiling ...................................................................................................................................................15
Care&Cleaning..........................................................................................................................................16
Ifthefanisnoisy...............................................................................................................................................16
Ifthefanrotatesbutdoesnotcreatemuchairflow ........................................................................................16
GeneralInformation................................................................................................................................16
NormalWearandTear. ....................................................................................................................................17
CeilingFanWarranty. .......................................................................................................................................17
CeilingFanWarrantyPeriod.............................................................................................................................17
RemoteControlWarrantyPeriod.....................................................................................................................17
BalanceofWarrantyonRepairedorReplacedProducts. ................................................................................17
TransferofWarranty. .......................................................................................................................................18
ThefollowingisNOTcoveredbywarranty. .....................................................................................................18
Aeratronceilingfanwarrantydetails ...............................................................................................................19

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
3
Instructions
ThankyouforchoosinganAeratron™CeilingFan.Youhavechosenthebest!Weareconfidentthat
yournewceilingfanwillprovidemanyyearsofenjoyment.
Generalprecautions
Pleasereadandfollowtheseinstructionscarefully,andbemindfulofallwarningsshownthroughout
thismanual.
Thisfanmustbeinstalledbyalicensedandqualifiedelectricianaccordingtolocalauthority
regulations.
Becautious!Readallinstructionsandsafetyinformation,andreviewtheaccompanyingassembly
diagramsbeforeinstallingyournewfan.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryor
mentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionor
instructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
Locationandinstallationrequirementsforyourfan
Toprovideadequateclearancefromthefloorthelowestpointonthefanbladesmustbeatleast2.1m
(7’)fromthefloorinAustralia,andatleast2.3mfromthefloorintheEuropeanUnionandaffiliated
countries.
Note:Forafanmounteddirectlytotheceiling,thelowestpointofthefanbladeisapproximately
300mm(1foot)belowtheceiling.
Makesurethatthechosenlocationofthefanwillnotallowtherotatingfanbladestocomeinto
contactwithanyobject.

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
4
Ensureceilingjoistsaresoundandofadequatesizeandstrengthtosupporta35Kg(77lb)load.
Toreducetheriskoffire,electricalshockorpersonalinjury,ensurethatthefanmounting
bracketissupporteddirectlyfromthebuildingstructure.DONOTmounttoanoutletbox.
Themountingbracketmustbefirmlyscrewedtoaloadbearingstructuree.g.aconcreteceiling,steel
structureortimberframe.Ifatimberframeistobeaddeditmustbesecurelynailedorscrewed
betweentwobeams.
Mechanicalissues
Donotremovethefanfromtheceilingafterinstallation.
DonotattachtheFanAssemblybeforetheFanMotorHousingisinstalledandsecured.Toprotectthe
finish,theFanMotorHousingshouldbekeptinthecartonuntilreadytobeinstalled.
Afterthefaniscompletelyinstalled,checktomakesurethatallconnectionsaresecuretopreventthe
fanfromfallingand/orcausingdamageorinjury.
Toreducetheriskofpersonalinjury,donotbendordamagethemotorDriveShaftorFanAssembly
whenhandlingorinstalling
Aeratronfansareequippedwithaself‐balancingsystemanddonotrequiremanualbalancing!
Electricalissues
!Meansfordisconnectionmustbeincorporatedinthefixedwiringinaccordancewithnationalwiring
rules!
Thefancanbeusedinconjunctionwithsomehomeautomationsystems.Forfurtherinformation
pleasecontactAeratronPtyLtd.
Toavoidpossibleelectricshockduringinstallation,besureelectricityisturnedoffatthemainpower
boxbeforecommencingwork.Disconnectpowerbyremovingfuseorturningoffcircuitbreaker
beforeinstallingthefan.Ensureallsplicedconnectionsareadequatelyinsulated.
Note:
Nothinginthismanualisintendedtoinstructorassistuntrainedorunqualifiedpersonstoinstallthis
product.Additionally,itistheresponsibilityoftheinstallerandusertoapplycommonsenseandcare
atalltimes.

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
5
Unpackingyourfan
Unpackyourfanandcheckthecontents.Donotdiscardthecarton.Ifwarrantyreplacementorrepair
isevernecessary,thefanshouldbereturnedintheoriginalpackaging.
Examineallparts.Youshouldhavethefollowing:
HangerBracket MotorAssembly MotorHousing HangerBracket
Fastener
RemoteControlReceiver RemoteControlTransmitter 9VBattery
OR
HUB SCREW x 10

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
6
Checkingceilingconditionandpreparingforfaninstallation
Beforecommencinginstallation,turnoffelectricitysupplyatthemainpowerbox.
Disconnectpowerbyremovingfuseorturningoffcircuitbreakerbeforecommencingwork.
InstallationmountedtoCeilingJoist
Installmountingbrackettoceilingjoistusingthescrewsandwasherprovided.Themountingplate
shouldbeabletoholdaweightofatleast18kgs.
NOTE:Propercaremustbetakenwhenmountingtoconcreteceilings.Forsafemountingthese
ceilingsmayrequireplasticplugs/anchorsandstrongerscrews.
PreparingFanMotorAssembly
RemoveoneMotorHousingfixing AdjustremainingtwoMotorHousing
Screw,andputitasideforre‐assembly screwstoprovideclearancefor
withFanMotorHousinglater installingtheMotorHousing

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
7
NOTE:Installationofmultiplefansusingindependenttransmitterrequire“CODEMATCH”beforeinstallingthe
receiver,seepage#13.
InstallingRemoteControlReceiverintohangerbracket
SlideRemoteControlReceiverAfterinstallingreceiver,re‐
intoHangerBracketsinorientationadjustFanMotorassembly
showntoensurethedriveshaftis
vertical

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
8
MakeLIVE,GROUNDandNEUTRALconnectionsfromMainsPower(House)toTerminalBlock.
MakeLIVE,GROUNDandNEUTRALconnectionsfromRemoteControlReceivertoTerminalBlock.
Plugthe9‐PoleplugconnectorfromtheDCMotorintothe9‐PoleplugconnectorfromtheReceiver.
PreparingFanMotorHousing
EnsurethatMotorHousingScrew
Coversareinfullopenposition

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
9
AttachingFanMotorHousingtoMotorAssembly
LineupfixingholeInstallmotorhousing
inMotorHousingwithusingaclockwise
screwholeinchassisBayonetaction
andinstallscrew
EnsurethatFanMotorHousingfixingpointwithhole(notbayonetslot)isalignedwithchassisarm
fromwhichfixingscrewwasremoved(seepage6).
ClosingScrewCover
CloseallthreeScrewCovers

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
10
FanBladesandMiddlePieceAssembly
!CONSTANTLYHANDLEFANWITHCAREATALLTIMESTOAVOIDDAMAGINGTHEFAN/SURFACE!
e502
Placee502HubUpperontoacleanworkingarea.
Line‐upthethreemountingholesinthee500FanBlade
withthetwoscrewbossandholeintheHubUpper.
Fixthee500FanBladetightandfirmusing2Hubscrews
Fixseconde500Bladetightandfirmusing2Hubscrews
Withcare,turnthefanoverandfastenthee502HubLower
tothefanassemblyusingthe2Hubscrews

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
11
!CONSTANTLYHANDLEFANWITHCAREATALLTIMESTOAVOIDDAMAGINGTHEFAN/SURFACE!
e503
Placee503HubUpperontoacleanworkingarea.
Line‐upthethreemountingholesinthee500FanBlade
withthetwoscrewbossandholeintheHubUpper.
Fixthee500FanBladetightandfirmusing2Hubscrews
Fixsecondandthirde500Bladestightandfirmusing2Hub
screwsforeachBlade
Withcare,turnthefanoverandfastenthee503HubLower
tothefanassemblyusingthe3Hubscrews

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
12
FanBladestoShaftAssembly
RotateScrewCovertohidescrewhead.(Note:RotatingtheScrewCoverwillprevent
Pivotscrewfromfallingoutshoulditbecomeloose.)
PivotScrew

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
13
RemoteControlSet‐up
Codematchyourtransmitterandreceiver
Note:receiveritselfdoesnotneedtosetDIPswitch
Speed Up1‐2‐3‐4‐5‐6
Down6‐5‐4‐3‐2‐1
Tostartthefanpressspeedbutton
Tochangespeedoffanpressor(indicatedbyashortbuzzersound)
LCDindicatesmaximalspeed(max)
On/Off Pressthebuttontostartorswitchoffthefan
ForwardForcoolingeffectandincombinationwithAirConditionSystem
ReverseTosupportheatingsystemtoexchangetemperature
CodematchforTransmitter(Handheld)andReceiver
1. SetthecodetobeencodedbytheDipSwitchoftransmitter
2. Switchonthemainpowertoactivatethereceiver
3. Within3minutesafterthepoweristurnedon,pressthetransmitter’s“ON/OFF”keyanddo
notreleasefor5seconds
4. Receiverissuesfour(beep)shortsoundswhichindicatessuccessfulcodematch
5. Aftersuccessfulcodematch,thefanautomaticallyreturnstotheoriginalspeedasindicated
onLCDscreen
6. Pressanytransmitterbuttontocheckforproperfunctioning
7. Forcodechanges,repeatsteps1to6
ÆThetransmitterandreceiverwillmemorisethecodeforfutureuse(alsoifswitchedoff).
RemoteControlCodeSetting
SetyourDipSwitchtocontrolindividual
fan(s)(oneperfanhandset)orchosesame
codesettingforupto16fanswithina7m
radius

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
14
Technicalspecifications
e503ande502
Colour:white/silver/black
Remotecontrol:HandHeld,RF
Dimensions:e502ase503
Operatingspeed(rpm)/
PowerUsage(Watt)
e503
Speed1:51rpm/3.8W
Speed2:70rpm/4.5W
Speed3:103rpm/7.5W
Speed4:119rpm/9.5W
Speed5:139rpm/13.6W
Speed6:158rpm/18W
e502
Speed1:52rpm/3.9W
Speed2:73rpm/4.5W
Speed3:113rpm/7.7W
Speed4:131rpm/9.6W
Speed5:153rpm/13.6W
Speed6:177rpm/18.2W

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
15
SlopedCeiling

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
16
Care&Cleaning
RegularcleaningoftheAeratronCeilingfanbladesandfanmotorhousingistheonlymaintenance
thatisneeded.Duetotheself‐balancingdesign,alargebuildupofdustonbladesmayonlyin
extremecasescreateanimbalance,causingthebladetowobbleduringuse.Thisislikelytobemore
apparentonfanswithaextensionrod.
Regularcleaningofthebladeisrecommendedtopreventdustfrombuildingup.
1. Whencleaningyourfan,onlyuseasoftbrushorlintfreeclothtoavoidscratchingthefinish.
DONOTusewaterwhencleaningyourceilingfan.Itcoulddamagethemotororbladesand/or
createthepossibilityofelectricshock.
2. Whendustingtheblades,youmustsupportthebladestopreventbending‐nopressure
shouldbeappliedtothebladepivot.Aftercleaningtheblades,checktoensurethattheDrive
Shaftisvertical,otherwisethefanmaywobble.
3. Occasionally,itmaybenecessarytore‐tightenthefanbladesandfanmotorhousingfixing
screwstopreventanyclickingorhummingsoundsduringoperation.Thisisespeciallytruein
climateswithbroadtemperatureandhumidityranges.
4. Ifyouexperienceanyflawsintheoperationofyourfan,pleasecheckthepointsintheTrouble
Shootingsectionbelow.
WARNING:Exceptforitems1and2below,thefollowingrequireaccesstoareasofthefan
whichcarrylethalvoltage.Therearenoothercheckswhichcanbecarriedoutbytheuser.
Apartfromitems1and2,thefollowingmustbecarriedoutbyproperlyqualifiedpersonnel.
Ifthefandoesnotoperateproperly,orturnsonoroffatrandom.
1. Ifapplicable,changethebatteryintheRemoteControlTransmitter(Handset).
2. Theroommaycontainitemswhichobstructtheairflow.
3. Thefanmaybetoosmallforthesizeoftheroom.
4. Resetcodematch(seepage13)
5. Checkthemainandbranchcircuitbreakersand/orfuses.
6. Checkthewireconnectionstothefan.
Ifthefanisnoisy.
1. ChecktomakesurethatthescrewssecuringtheSuspensionBall,FanMotorHousingandFan
Bladesaretightenedsecurely(seepages9and12).
2. CheckthatallthescrewsintheHangingBracketaretight.
Note:Insomeareas,signalsaresentthroughthepowerlinesbytheelectricitysupplierforthecontrol
ofoffpeakhotwater,streetlightsandsoon.Thesesignalsmaycauseanintermittenthumminginthe
ceilingfan.FiltersareavailableinAustraliaatcustomercost.Itisnotthefaultoftheceilingfan.
Ifthefanrotatesbutdoesnotcreatemuchairflow
1. Theroommaycontainitemswhichobstructtheairflow.
2. Thefanmaybetoosmallforthesizeoftheroom.
GeneralInformation
1. Allelectricalmotors,includingfanmotorsmakesomenoise,andmayfeelhottothetouch.
ThisisNOTafault.
2. Ceilingfanstendtomoveduringoperationduetothefactthattheyarenotrigidlymounted.
(Rigidmountingscangenerateexcessivevibrationandstressonthemountings).Movementof

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
17
acoupleofcentimetresisquiteOKanddoesnotsuggestthatthefanwillfalldown.The
AeratronfanismountedsecurelyonametalHangerBracketwithrubbercushioningandaball
jointtoallowfreemovement.Pleasenotethatduetomanufacturingvariationsnotall
Aeratronceilingfansareexactlythesame‐somemaymovemorethatothers.Note:Excessive
wobblecanbecausedbytheDriveShaftnotbeingpositionedvertically.Thiscanbeeasily
rectifiedbyadjustingthepositionoftheFanMotorAssemblyintheHangerBracket(seepage
7).
3. Ceilingfansareanenvironmentallysmartchoicetohelpcoolyouinyourhome.Theyworkby
creatingairflowwhichcausesacoolingsensationontheskin.Thefasterthespeedoftheair
flow,thegreaterthecoolingsensation.Ceilingfansdonotworkbycoolingtheroom,sothey
shouldbeswitchedoffwhenthereisnooneintheroom,tosaveenergy.Theeffectivenessof
ceilingfansisalsodependentonthehumidityintheair‐theyaremoreeffectiveinhumid
environments,andlesssoindryones.
4. Duringwinter,ainreverseturningfanhelpstoreduceheatingcosts.Warmairrisestothe
ceiling,whereitcannotbefeltbytheoccupantsofaroom,especiallyinareaswithhigh
ceilings.Thefanhelpstokeepwarmairawayfromtheceiling,andmixesitwiththeairbelow.
NormalWearandTear.
1. Threadedcomponentsworkingslightlylooseorpartsevenslightlydamagedorbentduring
vigorouscleaningorbumpingcancausewobbleandnoise.Thisisnotcoveredunder
warranty,butcareduringmaintenanceandcleaningshouldpreventthisfromoccurring.
CeilingFanWarranty.
Youmusthavetheoriginalpurchasereceiptorbillofsaletomakeawarrantyclaim.Noclaimwillbe
acceptedunlessproofofdateofpurchaseisavailableatthetimeofmakingthewarrantyclaim.
CeilingFanWarrantyPeriod.
Theceilingfanitself,excludingtheRemoteControlTransmitterandReceiver,iscoveredbya2yearin‐
homewarranty.Duringthisperiod,AeratronPtyLtdwill,atitsdiscretion,repairorreplacedefective
product.LabourandproductdeliverycostsarebournbyAeratronPtyLtdduringthis2yearperiod.
Thecostofobtainingorusingspecialaccessequipment(scissorlifts,scaffoldingetc.)isspecifically
excluded,anditistheresponsibilityoftheownertoprovidesuchequipmentandhaveitsafely
installedandoperated.
Followingthe2yearin‐homewarrantyperiod,AeratronPtyLtd,offersarepairor
replacementwarrantyonthemotorassemblyonly,foranadditional3years.Duringthis3years,the
ownerisresponsibleforlabourcostsincurredinremovingandre‐installingthefan,andfortransport
coststoAeratron’srepaircentre.ReturnfreightwillbepaidbyAeratronPtyLtd.
RemoteControlWarrantyPeriod.
GeneralAeratronPtyLtdRemoteControlReceiversandTransmitters(Handsets)arecoveredbya1
yearin‐homewarrantyunderthesameconditionsasdescribedaboveforfans.Theadditional3year
repairorreplacementwarrantyoptionisnotofferedforRemoteControlTransmittersorReceivers.
BalanceofWarrantyonRepairedorReplacedProducts.
Anyreplacedorrepairedproductiscoveredonlybythebalanceofthewarrantyremainingonthe
originalarticle.

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
18
TransferofWarranty.
Ifthedwellingwherethefanorremotecontrolisinstalledchangeshands,thebalanceofthewarranty
passestothenewowner,providingtheoriginalbillofsalefortheproductisretainedbythenew
owner.
Warrantyforthefandoesnotcoverdamagetothefanifitismovedfromonedwellingtoanother
duringthewarrantyperiod.Thewarrantyisvoidedintotaliftheproductissoldassecondhand
goods.
ThefollowingisNOTcoveredbywarranty.
1. Anydamageincurredafterdeliverytotheownerthatisnotcausedbyafaultintheproducts
materialsorworkmanship;damagefromlightningorpowersurges;incorrectinstallation;
damageduetoincorrectinstallation;noiseorotherinfluenceofripplecontrolorinformation
accesssystemsoperatedoverpowerdeliveryinfrastructure;waterdamageofanykind;
installationoruseoutdoors;damagearisingfromconnectiontoorusewithalternativepower
systems(e.g.inverters,solar,etc.).
2. Ceilingfansnotinstalledbyalicensedelectrician.
3. Repairofaceilingfanusedincorrectly,accidentallydamaged,modifiedinanywayornot
servicedinaccordancewiththemaintenanceinstructions.
4. TravellingcostsincurredbyAeratronPtyLtdpersonnelorserviceagentsand/orthecostof
transportingandinsuringtheceilingfanbetweenthenearestAeratronPtyLtdagents'service
depotanditsnormallocation.Thesecostsmustbemetbythepurchaser.
5. Subjecttoanystatutoryprovisionstothecontrary,claimsfordamagetofurniture,carpet,
walls,ceilings,foundationsoranyotherconsequentiallosseitherdirectlyorindirectly
resultingfromafaultyceilingfan.
6. Signalssentthroughthemainspowersupplybytheelectricitysupplierforoffpeakhotwater,
andothersignalsincludingthoseforstreetlightsandsuch.Thesesignalsmaycausean
intermittenthummingintheceilingfan.Itisnotthefaultoftheceilingfan.
7. AeratronCeilingFansnotpurchasedandinstalledinAustralia.
8. Aservicecallfeewillbechargedwhere;thereisnothingwrongwiththeceilingfanor;the
defectiveoperationoftheceilingfanisduetofailureofelectricityor;theinstallationisnotin
accordancewithAeratronPtyLtdinstructionsand/orapplicablelocalregulationsor;the
defectshavebeencausedbyincorrectapplicationorabuseoftheceilingfanor;thedamage
hasbeencausedbyunauthorisedpersonsattemptingtorepairthefan.

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
19
WARRANTYPHONENUMBER+6193656470(AUSTRALIAONLY9amto5pmAest)
PleaseNote:Whenphoningforwarrantyyouwillrequirethefollowinginformation;dateofpurchase;
modelandcolourofthefan.Theinstallingelectriciansdetailsmayalsoberequired.
Aeratronceilingfanwarrantydetails
PleaseFilewithyourPurchaseReceipt
CustomerDetails
Name;______________________________________________
Address:____________________________________________
PostCode:___________________________________________
PhoneNumber:_______________________________________
FanDetails
Model:______________________________________________
Colour:______________________________________________
DateofPurchase:______________________________________
ElectriciansDetails
NameofElectrician:____________________________________
LicenceNumber:_______________________________________
Pleasesendto:
AeratronPtyLtd
“Warranty”
POBox3006
TamaramaNSW2026
Australia

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
20
Thank you!
Your AerAtron team…
Australianedition2011.
This manual suits for next models
1
Table of contents
Other AerAtron Fan manuals

AerAtron
AerAtron AE+2 Series User manual

AerAtron
AerAtron AE2+ Series Installation and operating instructions

AerAtron
AerAtron Ceiling Extension User manual

AerAtron
AerAtron FR3 Series Installation and operating instructions

AerAtron
AerAtron AE2 User manual

AerAtron
AerAtron FR3 Series Installation and operating instructions