Aerpro FTS600P User manual

DCTOAC
POWER INVERTER
INSTRUCTIONMANUAL
FTS600P FTS800P FTS1200P
Applicablefor:600W,800W,1200W

Ⅰ.Description:
Pure sine wave power inverter converts the DC electricity to AC electricity. It has been
widely used in cars, boats, mobile offices, telecommunications, public security,
emergencyservicesetc...
This power inverter incorporates a unique circuit design, with the advantage of a compact
size, light weight, super stable, and a high rate of conversion efficiency. It has five
protection functions which include, input under voltage protection, input over voltage
protection, overload protection, over temperature protection, output short circuit
protection.Pleasereadthiscarefullybeforeusing.
FeaturesandApplication
•Puresinewaveoutput
•Highefficientandportable
•Intelligentfancontrol
•Advancedmicroprocessordesign
•Withlowvoltage,highvoltage,overload,shortcircuitandoverheatprotection
Ⅱ.Productsandcablesdiagram:
①ACoutlet ②USBports
③Externalfuse ④DCinput“+”terminal(red)DCinput“”terminal(black)
⑤Coolingfans ⑥ON/OFFSwitch
⑦Powerindicator(green)Faultindicator(red)
Batterycable(red=positive,black=negative)

Ⅲ.ConnectionExplanation:
Connecting the DC power in the wrong way (reverse polarity) will destroy the power
inverter and may damage the electrical equipment in use, please follow the steps below
inthecorrectsequenceandmakesuretousetheinverterinthecorrectway.
1. Thereisoneredcableandoneblackcableforthebattery.Screwtightlyred
cablewithinverter’s“+”andbattery’s“+”terminal.
2. Screwtightlyblackcablewithinverter’s“”andbattery’s “” terminal; please
don’treversethepolarityoritwilldamagetheinverterand/orbattery.
3. Turnontheinverterswitch,greenlightshouldcomeon
4. Insert the plug of desired electrical appliance into the AC output socket of
inverter.
Note: For better operation, we recommend consumer to use with battery that exceeds
100AH.
Ⅳ.Application
1)Scopeofapplication:
a)OnlyuseforclassⅡappliances
Electricpowertoolseries:ElectricSaw,Drill,Sanderetc..
Officeequipment:Computers,printers,displays,scanners,facsimileapparatus;
Household appliances: Vacuum cleaner, fan, fluorescent lamp, filament lamp,
sewingmachine;
Kitchen series: Microwave oven, refrigerator, freezer, coffee machine, blender,
icemachine;hotoven;
Commercial installation series: Metal halogen light, watercraft, cars, solar energy
andwindpowergeneration.
Electric Field series: TV, radio, game player, VCR, power amplifier; monitoring
equipment,satellitecommunicationequipment.
Note: While using please follow the related power of the inverter. Do not over load the
inverter.Itisbettertokeeptheinverterworkingat85%ofit'srelatedpower.

b)Electricalappliancesthatareincompatiblewiththeseinverters
Allelectricappliancesthatexceedtheratedpoweroftheinverter
Generally capacitive loads and perceptual load appliances are not applicable: Air
conditioners,highpowerelectricdrills,fridges,microwaveovens,blenders;
We do not recommend using these inverters with appliances which have strict power
requirements, such as precise equipment, if using ordinary power inverters with this kind
ofequipmentitwillaffectthedatameasurement.
c) Scope of electric appliance that are incompatible with the USB (Only for
inverterswithUSBport.
1. USB is only for charging and does not have data exchange
function;
2. Before charging please check carefully if the charging current of
the appliance is below the inverters current, if it is exceed the
charging current of the inverter please do not use, or it may destroy
theUSBport.
3. Some appliance must be charged using a specific charger, so
pleasedon’tchargewiththeinvertersUSBport.
2)Usage.
a) The inverters input voltage must be same as battery’s voltage. The appliance’s
working voltage must be same as inverters output voltage; once all are the same, connect
theminrightwaybasedon“ConnectionExplanation”ofthemanual.
b)Pleaseusetheinverterinventilatedareasandmakesurethefanisnotblocked.
c) Do not put the inverter in rain or in humid places, keep it dry. In order to keep a
longlifespanoftheinverter,pleasekeepitworkingunder85%oftherelatedpower.
d) The inverters have an input under voltage protect function, input over voltage
protect function, over load protection function, over temperature protect function
and short circuit protect function. If these conditions occur, the inverter will stop
working, after a short period where it may need to cool down the inverter will
restartworkautomatically.Pleasecheckallapplianceratingsandconnections.
e)Tosaveenergy,thefanwillnotworkunless
1. The fan will work when the load is exceeded by 30% of the related
poweroftheinverter;
2. When the inside temperature of the inverter exceeds 60 degree, the
fanswillwork.
f.Aboutextensioncableuse:

1. We do not recommend the use of any extended cables between the
inverter and the battery, It will cause loss of DC electricity and the
invertersoutputvoltage.
2. If you really need use an extension cable we suggest you use high
qualitycabletoreducethelossofelectricity.
g.Othermatters:
1. This is a pure sine wave inverter; If you are measuring the voltage
pleaseusepreciseequipment.(RMS)
2. When supplying power to audio system, radio or TV, the appliance
mayhaveinterferenceandthisisnormal.
3. When using in cars, please don't run the inverter while the engine
hasstopped.
4. Please do not open the inverter, for service please use a
professionaltomendit.
Ⅴ.Safety:
1. Please do not operate the inverter while your hands are wet, Keep it away from
children.
2. The temperature of the shell will be high after extended use, so do not touch it in case
ofscalding;
3.Donotputmetalobjectsintotheinverterintothecasetopreventelectricshock.
4. Do not touch the metal of the socket while inserting the plug into the socket of the
inverter.
5.Keeptheinverterawayfromexplosives;
6.KeepallACelectricawayfromtheinverterDCinputoritwilldamagetheinverter
andalsomaycausesevereelectricshock.

Ⅵ.ProtectfunctionandRestartworkmethod;
Function
Statedescription
Restartworkmethod
LEDlight
alarm
ACoutput
Inputlow
voltage
alarm
Greenon
Redoff
Alarm
AChaveoutput
Whenthevoltageofthe
batteryreturnstothe
relatedvoltage,alarm
willstopautomatically.
Inputlow
voltageshut
down
Greenon
Redon
No
alarm
NoACoutput
Whenthevoltageofthe
batteryreturnstothe
relatedvoltagethe
inverterwillstart
working,greenlightwill
goon,redlightwillgo
off.
Inputover
voltage
protection
Greenon
Redon
No
alarm
NoACoutput
Whenthevoltageofthe
batteryreturnstothe
relatedvoltagethe
inverterwillstart
working,greenlightwill
goon,redlightwillgo
off.
Overload
protection
Greenon
Redon
No
alarm
NoACoutput
Reducetheloadto
acceptablerange,
theinverterwillstart
working,greenlightwill
goon,redlightwillgo
off
Over
temperature
shutdown
Greenon
Redon
Alarm
NoACoutput
Whentheinside
temperaturereturnsto
acceptablerange,
inverterwillstart
working,greenlightwill
goon,redlightwillgo
off.
Outputshort
circuit
Greenon
Redoff
No
Alarm
NoACoutput
Whenshortcircuitis
removed,inverterwill
starttowork
automatically.
TheUSBportwillobserveallprotectionconditionsasabove.
Ⅶ.Wastedisposal:
Pleasediscardthisproductthoughtfullyasitmaycauseenvironmentalpolluti

Ⅷ. Specification:
specification FTS600P FTS800P FTS1200P
Input voltage DC 12V (DC 11-15V)
Output voltage AC 220V ± 10%
Output frequency 50 ± 1Hz
USB outputs x 2 DC 5V,2100mA
Continuous power 600W 800W 1200W
Peak power 1200W 1600W 2400W
Output wave Pure sine wave
Distortion rate < 3%
Effiency >85%
No load current <0.95A
Input under
voltage alarm
12V input DC 10.2 – 10.8V
Input under
voltage shut
down
12V input DC 9.2 – 9.8V
Input over
voltage shut
down
12V input DC 15 – 16V
Overload shut down 660W – 780W 960W – 1060W 1300W – 1500W
Working temperature 5 – 35℃
Heat dissipation method fans
Cable Red/Black Battery Cable
Technical Assistance. If you need assistance Aerpro Inverter now or in the
future, contact Aerpro Support Australia: www.aerpro.com/Contact
This manual suits for next models
2
Other Aerpro Inverter manuals
Popular Inverter manuals by other brands

Jefferson Professional Tools & Equipment
Jefferson Professional Tools & Equipment JEFGENDIEWEL180 user manual

Samlex Europe
Samlex Europe PURE SINEWAVE PS3000-12 owner's manual

Schumacher
Schumacher PID-410 owner's manual

FireBird
FireBird CPK 7210 N manual

Fluke
Fluke 6062A instruction manual

INVT
INVT CHV160A Series Operation manual

CEA
CEA PROJECT 1300 Operator's manual

Digital Instruments
Digital Instruments MXS-EVO Manual guide

Oase
Oase Solarsafe 17 operating instructions

MPP Solar
MPP Solar Grid PV-Inverter 10Kw Installation and operation manual

Hopewind
Hopewind hopeSun Series Quick installation guide

V-TAC
V-TAC 11583 instruction manual