7224 & 7226 OPERATOR’S MANUAL – SECTION 4
14
Front-Panel Indicators
4.1.4 Main Status Indicators
Four Main Status indicators are located on the am-
plier’s front-panel (see Figure 4.4). These LEDs
monitor the internal conditions of the amplier and
indicate the current state of operation. The chart in
Figure 4.5 details the operational modes indicated
by the Main Status indicators.
NOTE: See the “Applications” section for main
status indicator interpretation when operating a
multi-amp system.
Figure 4.6 – Fault Status Indicators
Indicator is lit Indicator is not lit Indicator may be lit
Main Status
Indicators Fault Status
Indicators State of Operation
Action Needed to Clear Fault
Condition and Return to
Run Mode
Run
Ready
Standby
Stop
Fault
Over Load
Over Temp
Over Voltage
Output Fault status: This indicates
that an Output Fault condition has oc-
curred and the amplier has been placed
in Standby mode. The Fault indicator
will light under two conditions: 1) High-
frequency oscillation is causing high
shoot-through current; or 2) An output
transistor has shorted, causing the output
fault condition.
This fault condition cannot be cleared
using the front-panel Reset button. See
the “Troubleshooting” section for more
information on diagnosing and clearing
this fault condition.
Run
Ready
Standby
Stop
Fault
Over Load
Over Temp
Over Voltage
Over Load status: This indicates that
the output of the amplier could not follow
the input signal due to voltage or current
limits. Under normal operation with the
factory-default settings, an Over Load
condition will not place the amplier in
Standby mode. If the amplier has been
congured to be forced to Standby on
Over Load, the amplier will be placed in
Standby mode when the Over Load indica-
tor lights.
To remedy the Over Load fault during
operation, turn down the level of the input
signal until the Over Load indicator turns
off. To clear an Over Load fault condition
when the amplier is forced to Standby,
turn down the level of the input signal,
then push the Reset button.
Run
Ready
Standby
Stop
Fault
Over Load
Over Temp
Over Voltage
Over Temp status: The amplier
monitors the temperature inside the high-
voltage transformers, low-voltage trans-
former and in the output stage heat sinks.
The Over Temp indicator will light and the
amplier will be placed in Standby mode
when the temperature sensors detect a
condition that would damage the ampli-
er. If the Over Temp pulse is extremely
short, as in the case of defective wiring or
switches, the Over Temp LED may be lit
too briey to observe.
To reset after an Over Temp fault has
occurred, make sure the fans are running,
and then remove the input signal from the
amplier. Allow the fans to run for about
5 minutes, and then push and hold the
Reset button to return the amplier to
Run mode (factory default) or Standby/
Stop mode (if the amplier has been
congured to start up in Standby mode).
See the “Troubleshooting” section for
information on correcting the cause of an
Over Temp fault condition.
Run
Ready
Standby
Stop
Fault
Over Load
Over Temp
Over Voltage
Over Voltage status: This indicates
that the AC mains voltage is more than
+10% of nominal. The amplier will be
forced to Standby when an Over Voltage
condition occurs. When the Over Voltage
condition is cleared, the amplier will auto-
matically return to Run mode.
To clear an Over Voltage fault condition,
the AC mains must be brought down to
the nominal value. If the amplier does
not return to Run mode when the Over
Voltage condition has cleared, the ampli-
er may require servicing. Please see
the “Troubleshooting” section for more
information.