Page 10 of 78
IEC 60950
Clause Requirement Test Result – Remark Verdict
TRF No.: I950___E TRF originator: FIMKO
Measured voltage (V)...........................................:
<15k
Measured capacitance (PF).................................. :
<45µC
2.4.3 Connection of limited current circuits to other
circuits Complies. P
2.5 Limited power sources N
Inherently limited output N
Impedance limited output N
Overcurrent protective device limited output N
Regulating network limited output under normal
operating and single fault condition N
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N
Output voltage (V), output current (A), apparent
power (VA) ........................................................... :
Current rating of overcurrent protective device (A)
2.6 Provisions for earthing and bonding P
2.6.1 Protective earthing Reliable connection of the
metal chasis to the PE
terminal (appliance inlet) via
a green/yellow insulated wire.
P
2.6.2 Functional earthing N
2.6.3 Protective earthing and protective bonding
conductors See below. P
2.6.3.1 Size of protective earthing conductors No power cord provided. N
Rated current (A), cross-sectional area (mm2),
AWG..................................................................... :
2.6.3.2 Size of protective bonding conductors See 2.6.3.3. N
Rated current (A), cross-sectional area (mm2),
AWG..................................................................... :
2.6.3.3 Rated current (A), type and nominal thread
diameter (mm) ...................................................... :
N
Resistance (:) of earthing conductors and their
terminations, test current (A) ................................ :
See appended table 2.6.3.3. P
2.6.3.4 Colour of insulation............................................... :
Green/yellow wire used. P