Power and Data Connections
RS 485 and power via XLR 4
RS485 and power via Ethercon
RJ 45 Plug
EIA/TIA 568B
RS 485 Description
1
Orange/White
RS 485 +
2
Orange
RS 485 -
3
Green White
Not Connected
4
Blue
DC +
5
Blue /White
DC +
6
Green
Not Connected
7
Brown/White
DC Ground
8
Brown
DC Ground
RJ45 –XLR4 Pin-out
RJ45 Plug
EIA/TIA 568B
RS485
Description
XLR 4 Male
1
Orange/White
RS485 +
2
2
Orange
RS485 -
3
3
Green/White
Not Connected
Not Connected
4
Blue
DC +
4
5
Blue/White
DC +
4
6
Green
Not Connected
Not Connected
7
Brown/White
DC Ground
1
8
Brown
DC Ground
1
Agile Remote Cameras Ltd
Otterbourne Farm, Kiln Lane. Winchester. Hants. SO21 2EN UK
+44(0) 1962 711211 hello@agileremotecameras.com
ARCMaxiController
OperatingInstructions
IP/POE
IMPORTANT NOTE: The desk must use the 12V power supply provided.
XLR 4
RS 485 Description
1
Ground
2
RS 485 +
3
RS 485 -
4
9-24V 1.5A
Introduction
The ARC Maxi controller provides full functional control for up to 12 ARC cameras.
Designed to offer the operator an ergonomic layout with easy access to all the key
engineering functionally required.
The desk has a single RJ45 connector to provide an interface to the POE switch,
providing by power for the desk as well as the data connection to the cameras. We
recommend that you also use the 12V power supply provided.
The controller has a number of dedicated controls as well as additional
configuration options and setting accessed via the OLED display and menu button.
The menu is set out with a simple A-Z menu offering operators easy navigation.
Set up and configuration
The web interface can be access through any internet browser. The standard IP
address of the controller is 192.168.100.235. The web interface is shown below.
The web interface provides access to the IP address of the controller and the IP
addresses associated with the cameras to be controlled.
Please Note: When changing addresses on the desk, the system needs to be power
cycled to allow any new MAC addresses to be registered.
Landing Page
IP/POE via Ethercon
RJ 45 Plug
EIA/TIA 568B
Description
1
Orange/White
Transmit + (Tx +)
2
Orange
Transmit –(Tx-)
3
Green White
Receive + (Rx +)
4
Blue
DC +
5
Blue /White
DC +
6
Green
Receive –(Rx -)
7
Brown/White
DC Ground
8
Brown
DC Ground
A Camera Address
B
AutoFocusOn/Off
C ExposureMode
D Iris Values
E WhiteBalanceManual/Auto/3200K/5600K
G
Shutter
H
Gain
I
BGain
J
RGain
K
Pedestal
L
Gamma
M Reverse Pan
N
Reverse Tilt
O
ReverseZoom
P
Mirror Image
Q
ImageFlip
R
VideoFormat(Videoformatwillchangeonnextpowerup)
S IR Mode On/Off
T
UpdateCamera
U Softwareversion
V
–
PresetStore
W Preset Delete
X
Roll Offset (Roll is only available on the ARC360 PTZ)
Y
SettingStore(RGain, BGain,Focus,WB,ExposureMode)
Joystick and Head Control
Individual cameras are selected using the buttons 1-12.
The two-axis joystick provides control for the pan and tilt axis.
Configuration of the joystick can be accessed via the menu.
Lens Control
Focus and zoom are operated via zoom rocker and focus wheel.
Configuration of the zoom rocker can be accessed via the menu.
Focus
Auto and manual focus can be accessed via the menu or the dedicated button on
the controller.
White Balance and Exposure Control
Control of these functions is accessed via the menu. Manual white balance will
allow for full control of the RGain and BGain functions.
Please note, when powering up the ARC Maxi Controller, the WB, Focus and
exposure mode need to be adjusted to ensure that they are in sync with the
camera.
Video Format
Video format can be changed through menu R. Using the rotary encoder, select the
required video format and press the execute button. Once the command has been
sent, the camera must be power cycled for the change to take effect.
Login
Username: admin
Password: pw
IP Configuration Page
Address Set UP
Saving Configuration Files
Presets
Storing and deleting presets is managed through menu’s V and W. To store a preset
position, drive the camera to the desired position and adjust the zoom and focus.
With Preset Store selected, press the allocated numbered button, the button will
illuminate to confirm the position has been stored. To recall any pre-set positions,
the menu must be moved away from the Preset Store option. To delete previous
positions, select Preset Delete on the menu and simply press the preset button and
the illuminated button will turn out.
Update Camera
There is no bidirectional communication between the camera and the desk,
therefore when a camera is first turned on, there can be a difference between the
values shown on the menu display and the values within the camera. Selecting the
update camera menu allows you to set the camera values to the camera to ensure
all control inputs are relative.
Roll Offset
The ARC360 cameras offers a driven third axis or driven horizon. This third axis is
controlled through menu X. There are 7 degrees of +/- rotation. If needed, pressing
EXECUTE will reset the zero value.
Setting Store
This allows you to configure the camera to a specific set of values which will
retained on power up. Profiles that can be stored include RGain, BGain, Focus
Auto/Manual, WB, Exposure Mode, and orientation of pan, tilt and zoom control.

Popular Controllers manuals by other brands

DIEL me 100 V2 Installation and instruction manual

DIEL

DIEL me 100 V2 Installation and instruction manual

Victron energy BlueSolar MPPT 150/70 manual

Victron energy

Victron energy BlueSolar MPPT 150/70 manual

SHAKS S2i Product service manual

SHAKS

SHAKS S2i Product service manual

Weidmüller STARTERKIT-UC20-WL2000-IoT quick start guide

Weidmüller

Weidmüller STARTERKIT-UC20-WL2000-IoT quick start guide

Teledyne JCU-3 Installation & operation instructions

Teledyne

Teledyne JCU-3 Installation & operation instructions

AmerTac SLC6 instructions

AmerTac

AmerTac SLC6 instructions

Omron SYSMAC C200HS installation guide

Omron

Omron SYSMAC C200HS installation guide

Mitsubishi MELSEC-A series user manual

Mitsubishi

Mitsubishi MELSEC-A series user manual

Franke ZA3OP0024 Installation and operating instructions

Franke

Franke ZA3OP0024 Installation and operating instructions

Sunricher SR-2309PRO-5C instructions

Sunricher

Sunricher SR-2309PRO-5C instructions

Adaptec ACB-2072A installation guide

Adaptec

Adaptec ACB-2072A installation guide

CTA Optiplus 3 operating manual

CTA

CTA Optiplus 3 operating manual

JUMO IMAGO 500 operating manual

JUMO

JUMO IMAGO 500 operating manual

ComAp InteliDrive Lite reference guide

ComAp

ComAp InteliDrive Lite reference guide

Metso VALVCON QX Series Installation maintenance and operating instructions

Metso

Metso VALVCON QX Series Installation maintenance and operating instructions

GF EA15 instruction manual

GF

GF EA15 instruction manual

DMC TSC-30/IC Product specification

DMC

DMC TSC-30/IC Product specification

Danfoss AME 110 NL datasheet

Danfoss

Danfoss AME 110 NL datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.