3
2
[System design safety points]
wWARNING
• Refer to this manual for details on the operating status of the robot controller and
related instruction manuals.
Design and configure the system including the robot controller so that it will
always work safely.
• The robot controller has an emergency stop terminal to trigger emergency stop.
Using this terminal, prepare a physical interlock circuit so that the system
including the robot controller will work safely.
cCAUTION
• Do not bundle control lines or communication cables together or in close contact with the
robot controller main circuit or power lines. As a general rule, separate them by at least
100mm. Noise in the main circuit or power lines may cause faulty operation or malfunctions.
• Data (programs, point data, etc.) stored in the robot controller is not guaranteed to be
unchanged, so be sure to save it into an external storage device.
[Installation safety points]
wWARNING
• Securely install the connectors into the robot controller, and when wiring the
connectors, make the crimp, press-contact or solder connections correctly, using
the tool specified by the manufacturer.
• Always shut off all phases of the power supply externally before starting
installation or wiring work. Failure to shut off all phases could lead to electric
shocks or product damage.
cCAUTION
• Use the robot controller within the environment specifications listed in this manual.
Using the controller in an environment outside the specification range could lead to electric
shocks, fires, malfunctions, product damage or deteriorated performance.
• Tighten the screws on the robot controller firmly to make secure connections.
• Never directly touch the conductive sections or electronic parts other than the rotary switches
and DIP switches on the outside panel of the robot controller.
• Securely install each connection cable connector into the receptacles or sockets.
Poor connections will cause faulty operation or malfunctions.
[Wiring safety points]
wWARNING
• Always shut off all phases of the power supply externally before starting
installation or wiring work. Failure to shut off all phases could lead to electric
shocks or product damage.
• Always attach the terminal cover (supplied) before turning on the power to the
robot controller after installation and wiring work are complete. Failure to attach
the terminal cover could lead to fire, electrical shock, product damage or
malfunctions.
cCAUTION
• Tighten the terminal screws within the specified torque range.
A loose terminal screw could lead to short-circuit, faulty operation or malfunctions. In
contrast, if the terminal screw is too tight, short-circuit, faulty operation or malfunctions could
also occur due to screw damage.
• Make sure that foreign matter, such as cutting chips or wire scraps, do not enter the robot
controller.
• Always store the cables connected to the robot controller in a conduit or clamp them securely
in place.
If the cables are not stored in a conduit or properly clamped, excessive play or movement, or
mistakenly pulling on the cable may damage the connector or cables, and poor cable contact
may lead to faulty operation or malfunctions.
• When disconnecting the cable, detach by holding the connector itself and not by tugging on the
cable. Loosen the screws on the connector (if fastened with the screws), and then disconnect
the cable.
Detaching by pulling on the cable itself may damage the connector or cables, and poor cable
contact may lead to faulty operation or malfunctions.