1-3
Models SLA5810/20 amd SLAMf10/20
Section 1 Introduction
Installation and Operation Manual
X-PR-SLA5800-SLAMf-Series-RevB-PC-eng
Part Number: 541B198AAG
January,2017
Table 1-1 Flow Ranges and Pressure Ratings
Table 1-2 Specifications
*Alarm modes are dependent on the communications interface. These are described in the corresponding digital communication interface manual.
**Hazardous area certifications have a temperature range limitation of 0-65°C.
PerformancePerformance
PerformancePerformance
Performance
Pressure AccuracyPressure Accuracy
Pressure AccuracyPressure Accuracy
Pressure Accuracy +0.25% of Transducer F.S., F.S. > 300 psia
(Including Linearity and Hysteresis)(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis)(Including Linearity and Hysteresis)
(Including Linearity and Hysteresis) +0.12% of Transducer F.S., F.S. ≤300 psia
Flow Accuracy (N2 equivalent)Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent)Flow Accuracy (N2 equivalent)
Flow Accuracy (N2 equivalent) N/A
Control RangeControl Range
Control RangeControl Range
Control Range 20:1 Typical - Application specific
Repeatability & ReproducibilityRepeatability & Reproducibility
Repeatability & ReproducibilityRepeatability & Reproducibility
Repeatability & Reproducibility 0.20% S.P.
LinearityLinearity
LinearityLinearity
Linearity Included in accuracy
Response Time (Response Time (
Response Time (Response Time (
Response Time (Settling time withinSettling time within
Settling time withinSettling time within
Settling time within System dependent
±2% F.S. for 0-100% command step)±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)±2% F.S. for 0-100% command step)
±2% F.S. for 0-100% command step)
Zero StabilityZero Stability
Zero StabilityZero Stability
Zero Stability < + 0.001% F.S. per 30 days
Temperature CoefficientTemperature Coefficient
Temperature CoefficientTemperature Coefficient
Temperature Coefficient ±0.1% of F.S. per °C
Pressure CoefficientPressure Coefficient
Pressure CoefficientPressure Coefficient
Pressure Coefficient N/A
(Flow Measurement Only)(Flow Measurement Only)
(Flow Measurement Only)(Flow Measurement Only)
(Flow Measurement Only)
Attitude SensitivityAttitude Sensitivity
Attitude SensitivityAttitude Sensitivity
Attitude Sensitivity The accuracy of the Pressure Sensor is not attitude dependent
RatingsRatings
RatingsRatings
Ratings
Operating Temperature RangeOperating Temperature Range
Operating Temperature RangeOperating Temperature Range
Operating Temperature Range -14 to 65
o
C (7 to 149
o
F)**
Transducer Pressure RatingsTransducer Pressure Ratings
Transducer Pressure RatingsTransducer Pressure Ratings
Transducer Pressure Ratings 15 psia/1.03 bara for < 15 psia full scale
15 psig/1.03 barg for < 15 psig full scale
100 psia/6.9 bara for < 100 psia full scale
100 psig/6.9 barg for 15-100 psig full scale
300 psia/20.7 bara for 100-300 psia full scale
300 psig/20.7 barg for 100-300 psig full scale
3000 psia/206.9 bara for 300-3000 psia full scale
4500 psia/310.3 bara for 3000-4500 psia full scale
Leak Integrity (external)Leak Integrity (external)
Leak Integrity (external)Leak Integrity (external)
Leak Integrity (external) 1x10
-9
atm. cc/sec He
MechanicalMechanical
MechanicalMechanical
Mechanical
Valve TypeValve Type
Valve TypeValve Type
Valve Type Normally Closed, Normally Open
Primary Wetted MaterialsPrimary Wetted Materials
Primary Wetted MaterialsPrimary Wetted Materials
Primary Wetted Materials 316L Stainless Steel, High Alloy Stainless Steel, Viton
®
fluoroelastomers.
Optional Buna-N, Kalrez
®
, Teflon
®
/Kalrez
®
, and EPDM
DiagnosticsDiagnostics
DiagnosticsDiagnostics
Diagnostics
Status LightsStatus Lights
Status LightsStatus Lights
Status Lights MFC Health, Network Status
Alarms*Alarms*
Alarms*Alarms*
Alarms*
Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption
Diagnostic/Service PortDiagnostic/Service Port
Diagnostic/Service PortDiagnostic/Service Port
Diagnostic/Service Port
RS485 via 2.5 mm jack (Located under the top cover in SLAMf version)
SLA58510/20 & SLAMf10/20SLA58510/20 & SLAMf10/20
SLA58510/20 & SLAMf10/20SLA58510/20 & SLAMf10/20
SLA58510/20 & SLAMf10/20
Flow Ranges and PrFlow Ranges and Pr
Flow Ranges and PrFlow Ranges and Pr
Flow Ranges and Pressuressur
essuressur
essure Ratings:e Ratings:
e Ratings:e Ratings:
e Ratings:
Pressure ControllerPressure Controller
Pressure ControllerPressure Controller
Pressure Controller Pressure ControllerPressure Controller
Pressure ControllerPressure Controller
Pressure Controller Flow RangesFlow Ranges
Flow RangesFlow Ranges
Flow Ranges MinimumMinimum
MinimumMinimum
Minimum MaximumMaximum
MaximumMaximum
Maximum Pressure EquipmentPressure Equipment
Pressure EquipmentPressure Equipment
Pressure Equipment
ModelModel
ModelModel
Model Control ModeControl Mode
Control ModeControl Mode
Control Mode N2 Eq. Ratings (lpm)N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm)N2 Eq. Ratings (lpm)
N2 Eq. Ratings (lpm) Full Scale PressureFull Scale Pressure
Full Scale PressureFull Scale Pressure
Full Scale Pressure Full Scale PressureFull Scale Pressure
Full Scale PressureFull Scale Pressure
Full Scale Pressure Directive (PED)Directive (PED)
Directive (PED)Directive (PED)
Directive (PED)
Min. F.S.Min. F.S.
Min. F.S.Min. F.S.
Min. F.S. Max. F.S.Max. F.S.
Max. F.S.Max. F.S.
Max. F.S. StandardStandard
StandardStandard
Standard StandardStandard
StandardStandard
Standard Module H CategoryModule H Category
Module H CategoryModule H Category
Module H Category
SLA5810/SLAMf10 Downstream 0.003 50* 1 psi 1500 psia/103 bara Sound Engineering
(Pressure Regulator) 0.1 10 1500 psi 4500 psia/310 bara Practices (SEP)
SLA5820/SLAMf20 Upstream 0.003 50* 1 psi 1500 psia/103 bara Sound Engineering
(Back Pressure Regulator) 0.1 10 1500 psi 4500 psia/310 bara Practices (SEP)
* Consult sales agent or Brooks Instrument for flow limitations < 10 psi F.S. pressure