3
normally.
d. Water drain pipe to drain continuously, so the unit can work continuously.
V. Start-up
a. Press the "On/Off’ button for once, the LCD display is light. After all the displays
are normal, the LCD displays current environment humidity and temperature;
Setting of “humidity: press “ + ”and ”--”buttons to set the required humidity. When
the setting humidity is 3% less than current humidity, the dehumidifier works; when the
setting humidity is 3% more than current humidity, the compressor stops working. The
humidity setting range is 5%-98%.
b. When the set humidity is less than 20%, the dehumidifier enters the mode of
successive dehumidification.
c. Setting of preset time:
Press the “Time“ button for the first time,
the “hour” time on the display flashes,
press “+”and “-”to adjust the current hour and minute time;
Press the “Time” button for the second time, the“T ON‘“on the LCD flashes, press
“+”and “-”to adjust the setting hours;
Press the“Time” button for the third time, the “T OFF” on the LCD flashes, Press
“+” and “-”to adjust the setting hours.
After setting timing boot/shutdown, the unit will timing automatically, when the
hours decrease to be 0, then it shutdown automatically.
d. After setting the mode of preset time, if the dehumidifier is shut off, it will
operate the whole mode of preset time; if it is in operation, it will operate the mode of
“preset stop time'". The setting hours range is 0-24hours.
e. Press "Time’" button for 10s, it display ‘F1", it‘s humidity correction; Press
“Time” button for successively twice, it displays "F2”, it’s defrost interval time (default:
30 minutes). Press “Time” button for successively three times. Is displays “F3”. it’s
defrost time (default: 8 minutes); Press ‘Time” button for successively four times, is
displays “F4”, it can choose the defrost mode, when displays "1
F4”. it enters intelligent
defrosting mode, suitable for ambient temperature is above 10oC; when displays "2
F4”, it enters fixed defrosting mode, suitable for ambient temperature is below 10oC.
VI.Notices
1. If the set humidity is higher than the actual humidity, the dehumidifier stops
working;
2. During dehumidification, after the compressor starts working, the fan and
compressor can only be stopped after working for at least 3 minutes; the compressor
can only be re-started 3 minutes after it stops;
3. If works under low temperature, the dehumidifier may judge the system
temperature automatically and defrost automatically; when defrosting, the indicator
of
defrosting is light, the fan works and compressor stops working.
4. The system has auto memory. When all the mode setting has been finished, if
there is sudden power cut during operation or the power jack slips out, the system may
store the current status before the power is cut and enter the operation mode before
power cut automatically after power is supplied;