Aikyo AD-1500B User manual



1
I. Important Notices for Safety
Before application, please read all the instructions.
- Before application, please confirm that the power supply is 220V/50Hz /1PH.
Do not stop operation of the dehumidifier by pulling out the power cord.
- Be careful with movement of dehumidifier and avoid rolling on and damaging
the wire.
- Do not put hand or stick-shape object to the grid.
- Do not allow kids to climb, stand or sit on the dehumiditier
- Disconnect the power cord before cleaning and repair.
- Please use appropriate power supply switch, do not use plug and ensure safe
earthing.
- Do not operate in closed and narrow room.
- Please keep this manual safely. .
Note: We advice that any repair should be carried out by professionals.
II. Introduction to Product
Dehumidifier is able to reduce air humidity of the space, leaving people to live work
and store goods in comfortable environment.
Dehumidifier of our company possesses such advantages of nice appearance,
compact structure and easy operation. It is widely applied to research and medical
products, commodity storage, underground project, kitchen, bathroom, archives room
and warehouse for dehumidification. With this dehumidifer, loss caused
by damp,
erosion and corrosion of apparatuses and instruments can be prevented.
III. Introduction to Structure
1. Air filter
2. Dry air outlet
3.Caster
4. Condensated water pipe
5. Return air inlet
6. Control panel

2
IV. Operation instuction
Button Function
Button
Description
1
Turn on and turn off machine
2
Press this button for once, and it enters the mode of setting
humidity
Press this button for successively twice, it enters the mode of preset
start-up
Press this button for three times, it enters the mode of preset stop
Long press this button for four times, it exit the setting mode.
3
Press this button directly to increase the set humidity. Buzzer buzzes
once for each pressing and the set humidity increases by 1% RH.
Press this button to increase the presetting time, each pressing and
the time il by 1 hour
4
Press this button directly to decrease the set humidity. Buzzer
buzzes
once for each pressing and the set humidity decreases by
1%RH.
Press this button to decrease the presetting time, each pressing and
the time d by 1 hour.
1. Display range for humidity is 5 % -98 %.
2. Auto detection of temperature/humidity failure.
a. When the system detects that temperature sensor exceeds the limited range,
the system enters mode of temperature sensor failure. Under this mode, LCD displays
temperature failure code “E1”, the system works in circle of dehumidification for 30
minutes and defrosting for 10 minutes;
b. When the system detects that humidity sensor exceeds the limited range, the
system enters mode of humidity sensor failure. Under this mode, LCD displays
humidity failure code “E2” and stop working
c. After temperature/humidity sensor failure is eliminated, the system works

3
normally.
d. Water drain pipe to drain continuously, so the unit can work continuously.
V. Start-up
a. Press the "On/Off’ button for once, the LCD display is light. After all the displays
are normal, the LCD displays current environment humidity and temperature;
Setting of “humidity: press “ + ”and ”--”buttons to set the required humidity. When
the setting humidity is 3% less than current humidity, the dehumidifier works; when the
setting humidity is 3% more than current humidity, the compressor stops working. The
humidity setting range is 5%-98%.
b. When the set humidity is less than 20%, the dehumidifier enters the mode of
successive dehumidification.
c. Setting of preset time:
Press the “Time“ button for the first time,
the “hour” time on the display flashes,
press “+”and “-”to adjust the current hour and minute time;
Press the “Time” button for the second time, the“T ON‘“on the LCD flashes, press
“+”and “-”to adjust the setting hours;
Press the“Time” button for the third time, the “T OFF” on the LCD flashes, Press
“+” and “-”to adjust the setting hours.
After setting timing boot/shutdown, the unit will timing automatically, when the
hours decrease to be 0, then it shutdown automatically.
d. After setting the mode of preset time, if the dehumidifier is shut off, it will
operate the whole mode of preset time; if it is in operation, it will operate the mode of
“preset stop time'". The setting hours range is 0-24hours.
e. Press "Time’" button for 10s, it display ‘F1", it‘s humidity correction; Press
“Time” button for successively twice, it displays "F2”, it’s defrost interval time (default:
30 minutes). Press “Time” button for successively three times. Is displays “F3”. it’s
defrost time (default: 8 minutes); Press ‘Time” button for successively four times, is
displays “F4”, it can choose the defrost mode, when displays "1
F4”. it enters intelligent
defrosting mode, suitable for ambient temperature is above 10oC; when displays "2
F4”, it enters fixed defrosting mode, suitable for ambient temperature is below 10oC.
VI.Notices
1. If the set humidity is higher than the actual humidity, the dehumidifier stops
working;
2. During dehumidification, after the compressor starts working, the fan and
compressor can only be stopped after working for at least 3 minutes; the compressor
can only be re-started 3 minutes after it stops;
3. If works under low temperature, the dehumidifier may judge the system
temperature automatically and defrost automatically; when defrosting, the indicator
of
defrosting is light, the fan works and compressor stops working.
4. The system has auto memory. When all the mode setting has been finished, if
there is sudden power cut during operation or the power jack slips out, the system may
store the current status before the power is cut and enter the operation mode before
power cut automatically after power is supplied;

4
VII. Safe Operation and Maintenance
Do not connect relay, extension cord or adaptor with this machine.
Otherwise, fire, electric shock and heating can be caused.
Do not place it near to equipments give heat such as furnace and heater.
Otherwise, the resin may be melted and causes fire.
Do not use this dehumidifier in places with direct sunlight or exposed to wind and
rain.
This machine is for indoor use only.
When there is any abnormity (smell of burnt), please shut off the machine and
unload the power cord.
Otherwise, fire, electric shock and new failures may be caused.
Do not use this dehumidificr in places exposed to chemicals.
The chemicals and solvent in the air may bring adverse effect to the machine and
result in leakage in water tank.
If the machine is spared for a long time, please unload the power cord.
When clearing the machine, stop it first and unload the power cord.
Otherwise, human injury may be caused.
During continuous drainage, please place the drain pipe appropriately for smooth
drainage.
If there is any possibility that temperature around pipe may result in icing,
continuous water drain is not allowed.
Do not repair, disassemble or alternate the machine without authorization so as
to avoid fire or electric shock accidents;
Please place the machine in firm places;
If the machine falls down, the water in water tank may leak out and damages stuff
around and results in creepage and cause fire or electric shock accidents;
Knacks to extend the service life of air purification filter mesh: .
If to be spared for a long time, keep the air purification filter mesh in plastic bag
and save hermetically.
Do not use dehumidifier in places that may be exposed to water.
There may be creepage if there is water and result in fire or electric shock.
Please use proper switch. Otherwise, fire or electric shock accidents may be
caused. Do not damage or alternate the power cord.
Do not place heavy things on power cord or heat up or pull forcefully the power
cord, otherwise power cord may be damaged and causes fire or electric shock
accidents.
Please connect the power cord firmly with the switch.
If the power cord is loose, there may be risk of electric shock.
Do not stop operation of dehumidifier by pulling out the power cord.

5
Otherwise fire or electric shock accident may be caused.
VIII. Electrical wiring diagram
IX. Unit Dimension

6
X. Operation Notices
1. When moving the machine. do not incline the machine for over 45° to avoid
damaging the compressor.
2. Temperature for operation of this machine is 5-38oC
3. When it is operating, the compressor gives off heat when it works, and
ambient temperature may raise by 1-3oC . Such phenomenon is normal and is safe to
use. When ambient temperature is below 10°C and absolute humidity is relatively
low, there is no need to use dehumidifier.
4.The air inlet and outlet must be away from the wall for at least 10 cm in order
not to impair the dehumidification effect.
5. Working environment shall be as airproof as possible to maximize
dehumidification effect.
6. Dust on the air purification filter mesh may impair its effect or even cause
failure. Please clear regularly for at least once a month. If there is much dust in the
environment, it must be cleared once a week or once a day. Pull does the front panel,
clear the filter mesh. Tap the filter mesh slightly or eliminate the dust by vacuum
cleaner or place the mesh in warm water (<40oC and add
appropriate neutral scour)
and brush and then wash with clear water and dry it.
Direct sunlight or baking shall be avoided to prevent deformation.
XI. Instruction on Code Failure
This dehumidifier is able to automatically judge failure. If there is any lailure,
there will be failure code displayed on the humidity display window.
Failure display
Problem
E1
Temperature defrost sensor failure
E2, E3
Ambient humidity/Temp sensor failure, if failure of humidity, it
displays E2; if failure of temp, it display E3
E8
Compressor protection

7
XII. Common troubleshooting
Failure
Cause analysis
Method
Dehumidifier
cannot work
1. Power cut
2. Power switch is not
energized
3. Power cord is not
connected
4. Fuse is melted
1. Recover the power
2. Energize the power
3. Connect the power cord
4. Replace the fuse
Dehumidification
is not ideal
1. Dust accumulated in air
purification filter mesh
2. Object blocking air inlet
and outlet
3. The door or window is
open
4. Refrigerant is leaking
1. Clear the filter mesh
2. Remove the blocking
object
3. Close the door and
window
4. Contact with distributor or
manufacturer for repair
Water leak
1. The machine in inclined
2. Water pipe is blocked
1. Level the machine
2. Remove the blocking
object
Abnormal noise
1. The machine is not placed
solidly
2. The filter mesh is blocked
1. Place the machine firmly
2. Clear the filter mesh
a. Where the above troubles cannot be fixed and repair is needed, please
contact supplier or distributor. Do not disassemble without authorization.
b. When the dehumidifier is in operation or stops, voice of circulating of
refrigerating can be heard. Such phenomenon is normal.
c. It is normal for the air outlet to drain hot air.

8
XIII. Table of Parameters
Model
AD-1500B
Power supply
220V/50Hz/1PH
Dehumidify capacity
(30oC, 80%)
138 L/Day
Rated input power
1450 W
Air Circulation
1300 m3/h
Compressor
Aikyo
Refrigerant/Charge
R410A / 930g
Suction pressure
2.5 MPa
Discharge pressure
4.0 MPa
Weight
52 kg
Unit size
480 * 415 * 1065 (mm)
The above parameters are subject to change without serving notice.

9
XIV. Warranty
Thank you for choosing our dehumidifier. It will bring you great convenience
on both work and life. If there is any failure, please contact our repair department
or after-sale service center. We will offer you good consultancy and repair service.
Warranty for the product purchased is one year since the day of purchase, for the
compressor is three years. Any failure occurred during this period can be repaired by
local distributor and repair station for free.
According to national law, the followings are not covered by warranty and will be
charged with cost (charge standard: repair fee + replacement of part)
1. Failure and damage caused by mal-operation of customer not following the
manual or instruction.
2. Damage caused by transportation or handling. Customer replaces,
disassembles and changes machine number without authorization.
3. Damage caused by such natural disaster as lightning strike, water disaster and
Fire.
4. Damage caused by use of power with abnormal voltage or power supplied by
non-power-supplying department.
5. Where the warranty card is lost, reproduced, or there is no invoice, or
no voucher of purchase or the warranty period has been expired.
6. Temperature sensor is easily damaged and is not covered by warranty.
7. Damages caused by use in adverse environment of being acid, alkaline, salty,
sticky, dusty and high temperature (over 38°C) are not covered by the warranty.
8. The machine has no explosion-protection. If there are any accidents caused
by use in explosive and corrosive environment, our company bears no liability.
9. Within the warranty period, parts to be replaced must be exchanged with
old
ones for new ones.

Table of contents
Popular Dehumidifier manuals by other brands

SMC Corporation
SMC Corporation IDG5*V4-***-*-X032 Series Operation manual

PoolPak
PoolPak ComPak AW Series Installation, operation and maintenance

Mitsubishi Electric
Mitsubishi Electric MJ-E152AK-H instruction manual

Ecoair
Ecoair DROID user manual

DèLonghi
DèLonghi DD30PE Instructions for use

Puredry
Puredry PDD 85200 FAMOUS user manual