Fehom PDGT701BE User manual

Commercial Dehumidifier
www.fehom.com
PDGT701BE
Please read the manual carefully
before using the unit
USER MANUAL


Thank you for purchasing our dehumidifier.
Fehom wishes our products and services can bring convenience to your work
and life.
We highly recommend you to keep the manual for reference, in case you
encounter unexpected issues using this unit.
Please read the manual carefully to ensure proper use of the dehumidifier.
Our dehumidifiers are widely used in family bedrooms, bathrooms, basements,
offices and storage rooms, etc.
It can be operated quickly and efficiently to reduce the room's humidity and
bring you a healthy and comfortable life.
If there is any problems of the product, please contact Fehom Customer
our efforts to help you address the problems.

12
01
02
03
04
13
15
16
17
Warranty & Contact Information
Common Faults and Solutions
The graphics and functions provided in this manual may not be the same as
the actual product. Please always refer to the actual product.
The model of the machine on the manual is for reference only. Please operate
the machine based on the actual product.
The right to interpret the relevant terms belongs to the company.

Safety Notes:
For your safety, please read the manual carefully and keep the manual before
you use the product for reference. Please use this product according to the
installation and operation instructions of this manual.

1
2
3
4
5
6
4
1
5
2
3
6

1.Understand the Control panel

When water tank is full, the PUMP will automatically start pumping water, and
the indicator light will flash.
When the water level in the water tank is too low, the PUMP will automatically
stop pumping water, and the indicator light goes out.
In the power-on state, long press the "PUMP” button for 3 seconds, the
PUMP function is forced to open, the indicator PUMP will flash.
In the power on or standby state, press the "Timer" button once to enter the
timer setting state: Timing indicator light up and the digital number " " flashes
to show the time.
In the timing setting state, press the "Up" or "Down" button to set the desired
time (setting range: 01-24h, can be cycled).
Press the button once again or no button operation for a few seconds, the
timing setting state will automatically be exited.
If the time is set to be 00, the time setting is invalid.
The humidity level can be set within a range of 10%RH to 98%RH in 1%
increments.
When it starts work, it will first automatically detect and show the room's
humidity. Press the "UP" button to change the humidity selection in 1%
increments.Press "DOWN" to make it decrease by 1%RH. " " Flash and
show the setting humidity.
When the humidity level is set at 30%RH, the dehumidifier will work at
continuous dehumidifying mode.
Press the "function" button once or no button operation for a few seconds will
automatically exit the humidity setting state.


1. Digital number will be flashing when the target humidity is setting or the
room humidity is lower than the set humidity.
2. When the setting value is read out to be lower than the room humidity, the
digital number will remain illuminated.
When the fan delays to start, running indicator will be flashing; it will
light up when the fan is running.
RUNNING

The dehumifidier will not be
ready for operation.
1.Turn off the dehumidifier
and unplug it;
2. Find the gravity drain
outlet at the bottom of the
dehumidifier and connect
the emergency hose to
drain;
3.After emptying the reser-
voir, close the gravity drain
outlet;
4.Connect the pump drain
hose;
Re-plug and start the
dehumidifier to check the
pump function.
EC

When the machine signals the alarm, it will flash or display the alarm, in case
there are multiple errors on the unit, it will display the errors in turn.
When one of above malfunctions occurs, the buzzer will alarm for a few
seconds, press any key during the alarm to release the alarm sound.
Fehom

1. Take out 4 screws and a handle from the accessories, and put the handle
into the groove at the back of the humidifier, making the screws correspond
to the screw holes.
2. Tighten all the four screws on the hands respectively, the installation is
finished.
Handle
Screws
Tighten all the four hand screws,
complete the installation.
Put the handle into the groove
at the back of the dehumidifier,
making the 4 screws correspond
to the screw hole.

This dehumidifier has an internal pump that will automatically drain the
condensate out via the long drain hose. Before turning on the dehumidifier,
make sure the hose has been connected to the drain outlet properly.
1. Uncoil the entire hose;
2. Attach the hose to the drain outlet;
3. Place the unattached end of the hose in a sink, drain bucket or outdoors:
Anywhere that the water can drain out safely (Please ensure that no kinks or
other obstructions will stop the water to flow).
NOTE:
• Ensure that water which runs to outdoors does NOT create a slip hazard.
• If you use a bucket or other container for water collection, check it regularly
to prevent overflows.
• The drain hose for the water pump can drain up to 15ft vertically. More than
15ft may cause water back up to the pump resulting in leakage.
• When turning off the dehumidifier, please take the hose out from the water
collection container to avoid the water back-flow and cause water leakage.

In power-disconnected status, tilt the dehumidifier as the figure shown, pull
out the rubber plug and put the dehumifier straight to drain the sewage in the
water tank.
Rubber plug
Inclination≥45°


Dehumidifier operating
but room not dry
Check the information below for troubleshooting steps that will save
you time to resolve issues that may happen with the unit.
The list includes most issues but not the results of defective unit, crafts
or materials in the unit. If all the troubleshooting steps have been
exhausted and isse is stilling occuring, feel free to get in touch with
Waykar Customer Service to get further assistance.

The dehumidifier is titled.
Drain hose connection is
not tight
The drain hose is blocked
The dehumidifier is titled
Place the dehumidifier on
flat surface.
Make sure the drain hose
connection is tight
Check hose for restrictions
Install the dehumidifier on
flat surface to minimize
vibration and noise
Leaking
The filter is blocked
The pump reservoir is not
in place
The pump is defective
The pump reservoir gets
dirty
Clean the filter
Place the pump reservoir
at the correct position
Replace the pump
Clean the pump reservoir
Noise
The pump does not drain
If the dehumidifier is still not working properly as expected and the
troubleshooting steps or solutions above may not resolve the issues,
please unplug the power and shut down the dehumidifier, then contact

Please clean the filter every
two weeks (do not use hot
water above 104℉,
gasoline or toluene).

MODEL NO.
P0WER SOURCE
REFRIGERANT
HIGH PRESSURE
RATED POWER(95°F,90%RH)
RATED CURRENT(95°F,90%RH)
LOW PRESSURE
INPUT POWER(65°F,60%RH)
INPUT CURRENT( ,60%RH)65°F
PDDT701BE
120V 60Hz~
1150W
10.3A
610W
5.5A
R410a(20.11oz.) (570g)
6.2MPa
4.0MPa
1.7M
P
a
MOISTURE REMOVAL(65°F,60%RH) 50 Pints/Day
MOISTURE REMOVAL(80℉,60%RH)
MOISTURE REMOVAL(86℉,80%RH)
MOISTURE REMOVAL(95℉,90%RH)
90 Pints/Day
150 Pints/Day
180 Pints/Day
MAXIMUM ALLOWABLE PRESSURE
This product can expose you to chemicals including Styrene and its compounds,
which is known to the State of California to cause cancer and birth defects or
other reproductive harm.
For more information, please visit: www. P65Warnings.ca.gov
Table of contents
Other Fehom Dehumidifier manuals