Aiphone Corporation
www.aiphone.com
(800) 692-0200
LEM-1DLC Instr
1221
LEM-1DLC
Master Station for Multiple Master Use, with Occupied Lamp
LEM-1DLC
Master #1
1
E
R
+
-
EL
EL
LEM-1DLC
Master #2
LE-D
Door
PT-1210NA PT-1210NA
1
E
R
+
-
EL
EL
EL-12S
OPERATION NOTES
1. Only one master station can be used at a time.
2. When the TALK button is pressed on the answering master station, the red LED above the OFF switch will light on
both masters. This feature is controlled by the “R” wire between master stations.
3. When the OCCUPIED light is illuminated, do not press the TALK button on the non-answering master stations, or
button. At that time, communication between the door and answering master station can continue normally.
4. Communication is not possible between master stations.
INSTALLATION GUIDELINES
1. Separate power supplies are required at each master station. DO NOT CONNECT +/- WIRES BETWEEN MASTERS.
Keep wires for power and communication in separate jackets.
2. The door strike can be powered from one of these power supplies (as shown) or from an independent source. See
3.
of door or door frame is used, install a door strike appropriate for that door.
4. The LEM-1DLC provides a normally open (N/O) contact closure for door release.
IMPORTANT
Each master
requires a
separate
power supply