AP-MS
DESCRIPTION:
The expanded AP-MS system provides high powered
two-waycommunicationwithupto50remotelocations.
One or two masters can be used, and a variety of
remote stations are available. Choose from standard
substations,horn speakers, vandalproofsub stations,
or two call sub stations. Expand a 10-call master with
a 10, 20, or 40-call add-on selector.
*NOTE: Add-on selectors cannot be connected to
standard AP-5M or AP-10M masters.
Aiphone Communication Systems • 1700 130th Ave. N.E. • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com
- 10 -
AP-10MS
SPECIFICATIONS:
Power Source: AC 110~125V, 50/60Hz. Cord on AP-10MS plugs into AC outlet.
Current Consumption: Maximum 45W
Output: 10W (master to sub); 0.3W (sub to master)
Calling: Mono-electronic tone while call button is pressed, plus LED for 20 seconds.
Communication: Press-to-talk at calling master
Hands free at remote station or responding master
Talk Channel: Single talk channel
Wiring: 1 twisted pair homerun from each remote station
Use Aiphone #832202 (22AWG)
Mounting: Desk or wall mount
Wiring Distance: 490’ w/ 22AWG; 1200’ w/18AWG
Dimensions (HxWxD):
AP-10MS: 9-15/16” x 10-7/8” x 5-1/2”
AP-10AS, AP-20AS: 9-15/16” x 6-15/16” x 5-1/2”
AP-40AS: 9-15/16” x 12-7/8” x 5-1/2”
FEATURES:
• Expands to 20, 30, or 50 stations
• Two master stations, with master-to-master
communication
• 10 watts of output power to remote station
• Call tone and LED to indicate call from remote
• Two-way communication
• Hands free communication at remote
• Separate transmit and receive volume controls
AP-40AS
SOME APPLICATIONS:
• Parking Garages or Lots
• Automotive Service Centers
• Warehouses
• Manufacturing Facilities
• Marinas
• High Noise Areas
High Powered Intercom System with Expanded Capacity
AP-MS Expandable High Power System
ARCHITECTS & ENGINEERS SPECIFICATIONS:
The intercom system shall be of an open voice, selective
calling type, with 10 watts of output power when transmitting
to a remote. Master station shall have capacity of 10 stations,
and add-on selectors shall be available in 10, 20, and 40
call sizes.
Master station shall have individual selector buttons with
associated LEDs for call-in indication, and a directory for
stationlabeling. Acall-inshall lightthe LEDfor approximately
20 seconds and activate a momentary call tone. The call
shall be answered by pressing the station’s selector button,
then press TALK button to transmit, and release to listen.
The person at the remote speaks hands free.
SPECIAL ORDER PRODUCTS:
Master Station
AP-10MS 10-call Master station
Add-on Selectors
AP-10AS 10-call Add-on selector
AP-20AS 20-call Add-on selector
AP-40AS 40-call Add-on selector
Sub Stations
LS-NVP/A Vandal proof, weather resistant
sub station
Accessories
BA-1P Paging adaptor
STANDARD PRODUCTS:
Sub Stations
AS-3A Sub station, surface mount
AS-3WA 2-call sub station, surface mount
AS-3N Ceiling speaker sub station
AH-108 10W 8 ohm horn with built-in capacitor
AH-16TN 16W 8 ohm horn (NP-25V capacitor or
NP-B call button required)
Accessories
NP-B Call button
NP-W Surface mount box for NP-B
NP-25V 33mfd, 25V, non-polarized capacitor
RY-AC External signaling relay
NBZ-M Mounting frame for AS-3N
N-EA Surface mount enclosure for AS-3N
SBX-NVP Surface mount box for LS-NVP/A
SYSTEM LAYOUT EXAMPLE:
Master station shall be equipped with power ON/OFF switch,
transmitand receivevolume controls,CALL andTALK buttons.
Station selectors shall be in rows of five, with an OFF button
for each row. An “Occupied” LED shall indicate if the system
is in use.
Compatible remote stations shall include 8 ohm horns or
speakers, standard sub stations with one or two call buttons,
and weather resistant vandal proof stations (able to be flush
or surface mounted).
System shall be manufactured by Aiphone.
AH-108AS-3ALS-NVP/A
LS-NVP/A
LS-NVP/A
=Twisted Pair Wire
(Aiphone Wire #832202)
AP-20M
- 11 -
AP-MS (2)
AS-3A

This manual suits for next models

10

Other Aiphone Intercom System manuals

Aiphone HM-7 User manual

Aiphone

Aiphone HM-7 User manual

Aiphone JF-DVF-HID-I User manual

Aiphone

Aiphone JF-DVF-HID-I User manual

Aiphone JK-1MD User manual

Aiphone

Aiphone JK-1MD User manual

Aiphone MY-1HD User manual

Aiphone

Aiphone MY-1HD User manual

Aiphone ??-??? User manual

Aiphone

Aiphone ??-??? User manual

Aiphone MP-1S User manual

Aiphone

Aiphone MP-1S User manual

Aiphone IE-1AD User manual

Aiphone

Aiphone IE-1AD User manual

Aiphone MK-2DG User manual

Aiphone

Aiphone MK-2DG User manual

Aiphone LE-SSV User manual

Aiphone

Aiphone LE-SSV User manual

Aiphone GT-1M-L User manual

Aiphone

Aiphone GT-1M-L User manual

Aiphone LAF-10B User manual

Aiphone

Aiphone LAF-10B User manual

Aiphone DE-UR User manual

Aiphone

Aiphone DE-UR User manual

Aiphone IX SERIES Manual

Aiphone

Aiphone IX SERIES Manual

Aiphone DA-2DS User manual

Aiphone

Aiphone DA-2DS User manual

Aiphone PC-359B User manual

Aiphone

Aiphone PC-359B User manual

Aiphone JM-DVF-L User manual

Aiphone

Aiphone JM-DVF-L User manual

Aiphone MK-DAC User manual

Aiphone

Aiphone MK-DAC User manual

Aiphone IP MULTIFUNCTIONAL MASTER STATION AN-8500MS User manual

Aiphone

Aiphone IP MULTIFUNCTIONAL MASTER STATION AN-8500MS User manual

Aiphone MY-1CD User manual

Aiphone

Aiphone MY-1CD User manual

Aiphone DOOR RELEASE RELAY MODULE RY-24L User manual

Aiphone

Aiphone DOOR RELEASE RELAY MODULE RY-24L User manual

Aiphone MK-DAC User manual

Aiphone

Aiphone MK-DAC User manual

Aiphone GFW-VBC User manual

Aiphone

Aiphone GFW-VBC User manual

Aiphone LEM-1 User manual

Aiphone

Aiphone LEM-1 User manual

Aiphone LEM-1DL/C User manual

Aiphone

Aiphone LEM-1DL/C User manual

Popular Intercom System manuals by other brands

KOCOM KIP-304 user manual

KOCOM

KOCOM KIP-304 user manual

Viking E-35-IP product manual

Viking

Viking E-35-IP product manual

Bticino PIVOT Technical data

Bticino

Bticino PIVOT Technical data

KOCOM KLP-305 series Operating & installation manual

KOCOM

KOCOM KLP-305 series Operating & installation manual

golmar PE-90-MS/6 quick start guide

golmar

golmar PE-90-MS/6 quick start guide

Fermax Cityline Installer manual

Fermax

Fermax Cityline Installer manual

Sygonix 1698497 operating instructions

Sygonix

Sygonix 1698497 operating instructions

Telex Audiocom IFB-1000 operating instructions

Telex

Telex Audiocom IFB-1000 operating instructions

Telex BTR-24 operating manual

Telex

Telex BTR-24 operating manual

Avidsen ELIA manual

Avidsen

Avidsen ELIA manual

DORANI C10 QUICK APARTMENT SETUP GUIDE

DORANI

DORANI C10 QUICK APARTMENT SETUP GUIDE

Vimar Elvox 7200 Series user guide

Vimar

Vimar Elvox 7200 Series user guide

Vimar ELVOX 0002/841.05 Installer's guide

Vimar

Vimar ELVOX 0002/841.05 Installer's guide

2N Helios IP Configuration manual

2N

2N Helios IP Configuration manual

Genway WL-03NL user manual

Genway

Genway WL-03NL user manual

Midland BTX1 quick start guide

Midland

Midland BTX1 quick start guide

Pentatech VT 81 Operating and safety instructions

Pentatech

Pentatech VT 81 Operating and safety instructions

IDTECK Star RFK101 user manual

IDTECK

IDTECK Star RFK101 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.