LEF-LD
Aiphone Communication Systems • 1700 130th Ave. N.E. • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com
- 20 -
LEF Loudspeaker Intercom System for Long Distance/Elevators
DESCRIPTION:
The LEF-LD system is designed with the
capability to operate at distances up to 4,000’
and for use in elevators. The sub stations are
availableineithersurfaceorflushmountstyles.
Any LEF, LAF-C/CA, or LDF master station is
available in the Long Distance version.
NOTE:
This is a SINGLE MASTER SYSTEM ONLY.
SOME APPLICATIONS:
The LEF-LD system can be used in
a variety of commercial applications:
• Commercial buildings
• Parking Lots
• Airports
• Gated entries
• Office complexes
FEATURES:
• Available in 3, 5, 10, 20, and 40 station sizes
• Systems up to 80 stations with LAF-C-LD system
• Surface mount (LEF) or semi-flush mount (LEF-C)
• Remote stations call to master with momentary
electronic tone and LED, remaining lit for 20 seconds
• Press-to-talk communication at master, hands free at
remote station
• Flush mount (IE-JA-LD), or surface mount (IF-DA-LD)
remote stations
• Simple wiring: 3 conductors to each remote
SPECIFICATIONS:
Power: 12V DC. Use PS-12C.
Output: 500mW at 20 ohms (transmit); 800mW at 20 ohms (receive).
Calling: Mono-electronic tone while call button is pressed, plus LED for 20 seconds.
Wiring: 2 common wires plus 1 individual wire per sub station. Use Aiphone #822203 (homerun)
or #822206 for up to 4 stations (looped).
Wiring Distance:
2,000’ with 22AWG; 4,000’ with 18AWG.
Mounting: Desk or wall mount
Dimensions: (H x W x D)
LEF-3-LD: 7-1/16” x 5-5/8” x 2-3/16” LEF-3C-LD: 8-1/4” x 6-1/8” x 1-3/8”
LEF-5/10/10S-LD: 8-1/8” x 7-1/2” x 2-3/16” LEF-5C/10C-LD: 9-7/16” x 7-7/8” x 1-3/8”
LAF-20C-LD: 5-1/2” x 13-5/8” x 10-1/4” LAF-20CA-LD: 5-1/2” x 17-9/16” x 10-1/4”
LEF-10-LD
LEF-LD Long Distance and Elevator Intercom System
- 21 -
ARCHITECTS/ENGINEERS’ SPECIFICATIONS:
The intercom system shall be of an open voice, selective
calling type with three channels for communication and
selective control.
Master station shall have selector buttons with associated
LEDsforcall-inindication,and a directoryfor station labeling.
A call-in shall light the LED for approximately 20 seconds
and activate a momentary call tone. The call shall be
answered by pressing the station’s selector button, then
pressing TALK button to transmit, releasing to listen. The
person at the remote speaks hands free.
SPECIAL ORDER PRODUCTS:
Surface Mount Master Stations
LEF-3-LD 3-call master for L.D./elevators
LEF-5-LD 5-call master for L.D./elevators
LEF-10-LD 10-call master for L.D./elevators
LEF-10S*-LD 10-call master for L.D./elevators
*Incl. All Call button. Add BG-10C
and PS-12F for All Call
Flush Mount Master Stations
LEF-3C-LD 3-call master for L.D./elevators
LEF-5C-LD 5-call master for L.D./elevators
LEF-10C-LD 10-call master for L.D./elevators
Console Style Master Stations
LAF-20C-LD 20-call master for L.D./elevators
LAF-20CA-LD 20-call hndst. mstr. for L.D./elevators
LAF-40C/CA-LD available upon request
LDF-LD available upon request
STANDARD PRODUCTS:
Sub Stations
IF-DA-LD Remote station, surface mount
IE-JA-LD Remote station, flush mt. stainless steel
Accessories
RY-AC External signaling relay
PS-12C 12V DC power supply, 1A
BG-10C All Call, Chime, and Music Adaptor
PS-12F Power supply for system with BG-10C
NP-25V Non-polarized, 33µfd, 25V Capacitor
(Required for each sub when using
the BG-10C.)
Master station shall be capable of transmitting and receiving
audio communication with remotes up to 2,000’ away with
22AWG wire, and 4,000’ with 18AWG wire. Controls on the
master stations shall include TALK and OFF buttons, voice
and call tone volume controls, and an “Occupied” LED to
indicate if the system is in use.
Compatible remote stations shall include surface or flush
mount styles designed for outdoor use, rated as weather
resistant.
System shall be manufactured by Aiphone.
LEF-LD (2)
SYSTEM LAYOUT EXAMPLE:
LEF-3-LD
IF-DA-LD
IE-JA-LD
IF-DA-LD
2
3
3
3
PS-12C

This manual suits for next models

7

Other Aiphone Intercom System manuals

Aiphone LA-B User manual

Aiphone

Aiphone LA-B User manual

Aiphone LEM-1DL User manual

Aiphone

Aiphone LEM-1DL User manual

Aiphone IX-DVF-4A Installation guide

Aiphone

Aiphone IX-DVF-4A Installation guide

Aiphone LAF-10B User manual

Aiphone

Aiphone LAF-10B User manual

Aiphone VB-10DM User manual

Aiphone

Aiphone VB-10DM User manual

Aiphone IE-2AD User manual

Aiphone

Aiphone IE-2AD User manual

Aiphone MB-D User manual

Aiphone

Aiphone MB-D User manual

Aiphone JPW-BA User manual

Aiphone

Aiphone JPW-BA User manual

Aiphone MJ-1AD User manual

Aiphone

Aiphone MJ-1AD User manual

Aiphone MY-1HD User manual

Aiphone

Aiphone MY-1HD User manual

Aiphone DB-1SD Operating manual

Aiphone

Aiphone DB-1SD Operating manual

Aiphone LE-DL User manual

Aiphone

Aiphone LE-DL User manual

Aiphone HM-7 User manual

Aiphone

Aiphone HM-7 User manual

Aiphone ACCESS SENTRY LEM-1DLS User manual

Aiphone

Aiphone ACCESS SENTRY LEM-1DLS User manual

Aiphone DA-1MD User manual

Aiphone

Aiphone DA-1MD User manual

Aiphone VC-K User manual

Aiphone

Aiphone VC-K User manual

Aiphone TCS-MH User manual

Aiphone

Aiphone TCS-MH User manual

Aiphone TD-12Z User manual

Aiphone

Aiphone TD-12Z User manual

Aiphone LAF-1B User manual

Aiphone

Aiphone LAF-1B User manual

Aiphone IX System User manual

Aiphone

Aiphone IX System User manual

Aiphone TALKMASTER IP-EWST Safety guide

Aiphone

Aiphone TALKMASTER IP-EWST Safety guide

Aiphone KB-3SD User manual

Aiphone

Aiphone KB-3SD User manual

Aiphone IP-EWST User manual

Aiphone

Aiphone IP-EWST User manual

Aiphone NDR-10 User manual

Aiphone

Aiphone NDR-10 User manual

Popular Intercom System manuals by other brands

Pilot Communications PA-200T Operational guide

Pilot Communications

Pilot Communications PA-200T Operational guide

Videx VRVK 6358 Installation handbook

Videx

Videx VRVK 6358 Installation handbook

sks CASA instruction manual

sks

sks CASA instruction manual

TCS PUK  Series Product information

TCS

TCS PUK Series Product information

International Electronics Oracle 607 manual

International Electronics

International Electronics Oracle 607 manual

NuTone VSM4RK operating instructions

NuTone

NuTone VSM4RK operating instructions

Passotel 1 mini user guide

Passotel

Passotel 1 mini user guide

AMX MET-ECOM Dimensional drawing

AMX

AMX MET-ECOM Dimensional drawing

Bpt MTMAL/01 Programming manual

Bpt

Bpt MTMAL/01 Programming manual

Channel Vision ST-3108 Setup guide

Channel Vision

Channel Vision ST-3108 Setup guide

suprema FaceStation 2 installation guide

suprema

suprema FaceStation 2 installation guide

Vimar ELVOX 8000 Series Mounting instructions

Vimar

Vimar ELVOX 8000 Series Mounting instructions

Bouyer PGM-1247 quick guide

Bouyer

Bouyer PGM-1247 quick guide

Elite Security Products Enterview 5 instructions

Elite Security Products

Elite Security Products Enterview 5 instructions

Elvox Digibus Galileo Series Installation and connection manual

Elvox

Elvox Digibus Galileo Series Installation and connection manual

Videx VRVK Series Installation handbook

Videx

Videx VRVK Series Installation handbook

SOMFY V300 installation guide

SOMFY

SOMFY V300 installation guide

Viking K-1275-IP Series product manual

Viking

Viking K-1275-IP Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.