manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Air Gunsa
  6. •
  7. Paint Sprayer
  8. •
  9. Air Gunsa AZ10 User manual

Air Gunsa AZ10 User manual

This AIR GUNSA spray guns kit complies to ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated.
IMPORTANT
This spray gun should be operated only by an adequately trained operator, for safe use and maintenance of the equipment. Any
misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee. AIR GUNSA disclaims all
responsibility for any accident or damage caused by failure to observe the operational and safety procedures as from this man-
ual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding spray guns operations, or if any missing parts or any damage during
transportation is found, please contact your nearest AIR GUNSA Company (see last cover page).
IMPORTANT SPECIFICATIONS
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
WARNING Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-
perty damage.
IMPORTANT Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the mini-
mum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and
safety as well as your own company regulations.
TECHNICAL SPECIFICATIONS
Manufactured by: AIR GUNSA _ Anest Iwata Gruop
(1) Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows.
(2) Paint viscosity:
21 sec/Ford cup#4 AZ10 HTE SP
54 sec/Ford cup#4 AZ10 HTE PC
Before use, adjustment or maintenance, it is important to read this instruction manual very
carefully. This manual must be stored in a safe place for any future reference that may be necessary.
GB
Model Nozzle Air Cap (1) Atomizing (2) Fluid Air Pattern
Orifice set Mark Air pressure Output Consumption Width
Ø mm (in) bar (PSI) ml/min Nl/min (cfm) mm (in)
AZ10 HTE SP / AZ10 HTE SP AV / AZ10 HTE PC Pressure feed
AZ10 HTE SP 0.8 0.8 (0.031) 08 150 210 (7.41) 190 (7.48)
AZ10 HTE SP 1.0 1.0 (0.039) 10 150 210 (7.41) 200 (7.87)
AZ10 HTE SP 1.3 1.3 (0.051) 13 200 210 (7.41) 230 (9.05)
AZ10 HTE SP 1.5 1.5 (0.059) 15 200 210 (7.41) 240 (9.45)
AZ10 HTE SP 1.8 1.8 (0.070) 18 250 280 (9.89) 280 (11.02)
AZ10 HTE SP 2.0 2.0 (0.079) 20 250 280 (9.89) 290 (11.42)
AZ10 HTE SP 2.5 2.5 (0.098) 25 300 290 (10.23) 300 (11.81)
AZ10 HTE PC with Pressure Container
AZ10 HTE PC 1.5 1.5 (0.059) 15 180 (6.36)
AZ10 HTE PC 1.8 1.8 (0.070) 18 250 (8.83)
AZ10 HTE PC 2.0 2.0 (0.079) 20 250 (8.83)
AZ10 HTE PC 2.5 2.5 (0.098) 25 190 (6.71)
2.5 (36)
2.5 (36)
300-400
(11.81-
15.75)
_
ANEST IWATA Europe S.r.l.
46, Corso Vigevano
10155 Torino - Italy
Tel. ++39 011 24 80 868
Fax ++39 011 22 74 406
www.anest-iwataeu.com
e-mail: [email protected]
Instruction Manual
AIR GUNSA s.r.l.
46, Corso Vigevano
10155 Torino - Italy
Tel. ++39 011 24 80 868
Fax ++39 011 22 74 406
Quality Air Spray Guns Since 1944
www.anest-iwataeu.com/airgunsa
Distributed by:
Recommended condition
Max. Pressure: 7.0 bar (100 PSI) Max. Temperature:
Noise Level (LAeqT) 75.2 dB (A) AZ10 HTE SP Atmosphere 5 ~ 40 °C
73.7 dB (A) AZ10 HTE PC Air and fluid 5 ~ 43 °C
Spray conditions
Recommended condition in Tech. Specifications
Air connection G 1/4”
Measuring point 1m backwards from gun, 1,6 m height
Model Weight Fluid
g (lbs) Connection
AZ10 HTE SP 1/4” 480 (1.06) G 1/4” M
AZ10 HTE SP 3/8” 480 (1.06) G 3/8” M
AZ10 HTE SP AV 1/4” 490 (1.08) G 1/4” M
AZ10 HTE SP AV 3/8” 490 (1.08) G 3/8” M
AZ10 HTE PC 970 (2.13) M16x1 F
SPRAY GUN
AZ10 HTE SP 1/4”- AZ10 HTE SP 3/8”
AZ10 HTE SP AV 1/4”- AZ10 HTE SP AV 3/8”- AZ10 HTE PC
72
SAFETY WARNINGS
1. Spark and open flames are strictly prohibited.
Paints can be highly flammable and can cause fire.
Avoid any ignition sources such as smoking, open flames, electrical goods, etc.
2. Never use the following HALGOGENATED HYDROCARBON SOLVENTS
which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.
- Unsuitable solvents: methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride, trichloroethylene, 1.1.1-
trichloroethane
(Be sure that all fluids and solvents are compatible with gun parts. We are ready to supply a material list used in the product.)
3. Securely ground spray gun by using air hose with built-in ground wire.
Ground wire : Less than 1MΩ. Check the earth stability periodically.
If not, insufficient grounding can cause fire and explosion due to static electric sparking.
1. Never point gun towards people or animals.
If done, it can cause inflammation of eyes and skin or bodily injury.
2. Never exceed maximum operating pressure and maximum operating Temperature.
3. Be sure to release air and fluid pressures before cleaning, disassembling or servicing.
If not, remaining pressure can cause bodily injury due to improper operation or scattering of cleaning liquid.
In order to release pressure, first stop supply of compressed air, fluid and thinner to spray gun. Then remove
fluid adj. knob and pull fluid needle set towards you.
4. Tip of fluid needle set has a sharp point.
Do not touch the tip of fluid needle during maintenance for the protection of the human body.
1. Use in a well-ventilated site by using spray booth.
If not, poor ventilation can cause organic solvent poisoning and catch fire.
2. Always wear protective gear (safety glasses, mask, gloves).
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
If you feel something wrong with eyes or skin, immediately see a doctor.
3. Wear earplugs if necessary.
Noise level can exceed 85 dB(A), depending on operating conditions and
painting site
4.If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome.
Be sure to take a rest if you feel tired.
1. Never alter this spray gun.
If done, it can cause insufficient performance and failure.
2. Enter working areas of other equipment (robots, reciprocators, etc.) after machines are turned off.
If not, contact with them can cause injury.
3. Never spray foods or chemicals through this gun.
If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter.
COMMENTS
FIRE OR EXPLOSION HAZARD
IMPROPER USE OF EQUIPMENT
PROTECTION OF HUMAN BODY
OTHER PRECAUTIONS
AIR CAP 1
NOZZLE HOLDER 2
NEEDLE PACKING NUT 4
TRIGGER STUD 5
COMPLETE AIR VALVE 7
AIR VALVE SHAFT 7-1
AIR VALVE SET 7-2
AIR VALVE SPRING 7-3
AIR VALVE SPRING SEAT 7-4
FLUID ADJUSTMENT GUIDE 7-5
PATTERN ADJUSTMENT 10
FLUID NEEDLE SPRING 12
FLUID NEEDLE ADJ. KNOB 13
FLUID NOZZLE 14
FLUID NEEDLE 15
TRIGGER 17
AIR NIPPLE 20
FLUID NIPPLE 24
AIR FLOW CONTROL VALVE 25
(AZ10 HTE SP AV/ AZ10 HTE PC)
PACKING SET C
AIR CAP PACKING SET D
NEEDLE PACKING SET (AZ10 HTE SP W) F
1l Aluminium Pressure CUP PC 19 B
for AZ10 HTE PC
36
SPARE PARTS LIST
NOTE: When ordering parts, specify gun’s model,
part name with ref.No. and marked No.of air cap
set, fluid nozzle and fluid needle.
SPARE PARTS LIST
Description Ref. Part
4. If something goes wrong, immediately stop operation and find the cause. Do not use again until you have solved the
problem.
HOW TO CONNECT
1. Connect an air hose to air nipple tightly.
2. Connect an applicable cup to fluid nipple tightly.
3. Flush the gun fluid passage with a compatible solvent.
4. Pour paint into container, test spray and adjust fluid output as well as pattern width.
HOW TO OPERATE
Suggested air pressure is 2.0 to 3.0 bar (29 to 44 PSI)
Recommended paint viscosity differs according to paint property
and painting conditions. 12 to 23 sec. / Ford cup #4 is recommendable.
Keep fluid output as small as possible to the extent that the job will
not be hindered. It will lead to better finishing with fine atomization.
Set the spray distance from the gun to the work piece as near as
possible within the range of 100_200 mm (3.9_7.9 in).
The gun should be held so that it is perpendicular to the surface of the workpiece at all times. Then, the gun should move in a straight
and horizontal line. Arcing the gun causes uneven painting.
CAUTION
- Use clean air filtered through air dryer and air filter. If not, dirty air can cause painting failure.
- When you use this gun for the first time after purchasing, adjust fluid needle packing set.
Slowly tighten fluid packing seat and loosen a bit when fluid needle set does not return
smoothly, and adjust so that fluid needle set smoothly moves.
- When use this gun for the first time after purchasing, clean fluid passages spraying thinner
and remove rust preventive oil.
If not, remaining preventive oil can cause painting failure such as fish eyes.
- Firmly fix hose or container to spray gun. If not, disconnection of hose and drop of container can
cause bodily injury.
OTHER PRECAUTIONS
100.200 mm
3.9-7.9 in
AZ10 HTE PC CUP
PC 19 B
AZ10 HTE PC
54
PROBLEMS AND REMEDIES
Problem Where it Parts to be Cause Remedy
occurred checked Retighten Adjust Clean Replace
Air leaks Air valve set Air valve *Dirt or damage on seat x x
(from tip
of air cap) Air valve seat set *Dirt or damage on seat x x
*Wear on air valve spring x
O ring *Damaged or deteriorated x
Paint Fluid nozzle Fluid nozzle - *Dirt, damage, wear
leaks fluid needle set on seat x x
*Loose fluid needle
adj. knob x
*Wear on needle spring x
Fluid nozzle - *Insufficient tightening x
gun body *Dirt or damage on seat x x
Fluid needle - *Needle does not return due
packing set to packing set too tight x x
*Needle does not return due
to paint buildup
on fluid needle x x
Fluid needle Needle packing *Wear x x
set, needle set
Packing seat *Insufficient tightening x
Paint does not Tip of gun Fluid adj. knob *Insufficient opening x
flow Tip hole of nozzle *Clogged x
Paint filter *Clogged x x
TROUBLESHOOTING
Spray Pattern Problems Remedies
1. Air enters between fluid nozzle and 1. Remove fluid nozzle to clean seat.
Fluttering tapered seat of gun body. If it is damaged, replace nozzle.
2. Air is drawn from fluid needle packing set 2. Tighten fluid needle packing.
3. Air enters at fluid container fitting nut or fluid 3. Fully tighten joint section.
hose joint.
1. Paint buildup on air cap partially 1. Remove obstructions from horn holes with
Crescent clogs horn holes. Air pressure from attached brush. But do not use metal
both horns differs. objects to clean horn holes.
1. Paint buildup or damage on fluid nozzle cir- 1. Remove obstructions.
Inclined cumference and air cap center. Replace if damaged.
2. Fluid nozzle is not properly fitted. 2. Remove fluid nozzle, clean seated section
1. Paint viscosity too low. 1. Add paint to increase viscosity.
Split 2. Fluid output too high. 2. Tighten fluid adj. knob to reduce fluid output
or turn pattern adj. knob clockwise.
Heavy 1. Paint viscosity is too high. 1. Add thinner to reduce viscosity.
Center 2. Fluid output is too low. 2. Turn fluid adj. knob counter-clockwise to
increase fluid output.
1. Fluid nozzle and fluid needle set are 1. Clean or replace fluid nozzle and fluid
Spit not seated properly. needle set.
2. The first-stage travel of trigger 2. Replace fluid nozzle and fluid
(when only air discharges) decreases. needle set.
3. Paint buildup inside air cap set. 3. Clean air cap set.
MAINTENANCE AND INSPECTION
Step-by-step procedure Important
1.Pour remaining paint to another container. Clean fluid passages and air cap set. 1. Incomplete cleaning can fail pattern shape and uniform particles.
Spray a small amount of thinner to clean fluid passages. Especially clean fully and promptly after use with two-component paint.
2.Clean each section with brush soaked with thinner and wipe out with waste cloth. 2. Do not immerse the whole gun in thinner. If done, it can damage parts.
When cleaning, never scratch any holes of air cap set and fluid nozzle, and
fluid needle set.
3. Before disassembly, fully clean fluid passages. 3. During disassembly, do not scratch seat section.
(1) Disassemble fluid nozzle. (1) Remove fluid nozzle after removing fluid needle set or while keeping
fluid needle pulled, in order to protect seat section.
(2) Disassemble fluid needle set. (2) Be careful when handling tip of fluid needle set since it is sharp.
You do not need to remove fluid adj. guide set from gun body. Disassemble fluid adj. guide set as little as possible.
Remove fluid adj. knob and fluid needle spring, and then pull out fluid needle
spring, and then pull out fluid needle set from back of fluid adj. guide set.
4.To adjust fluid needle packing set, while keeping fluid needle set inserted, 4.Too much tightening of fluid needle packing set can cause bad movement
tighten fluid needle packing seat by hand and then tighten further by spanner. of fluid needle set and fluid leakage from the tip of fluid needle set.
5.In order to assemble air valve, first assemble air valve & air valve spring 5. If you try to fit air valve spring and air valve to gun body set without fluid
& fluid adj. guide set together. Next, insert fluid needle set into fluid adj. guide set, needle set, air valve will not be fitted correctly and packing inside fluid
then fit it to gun body set and screw fluid adj. guide set. adj. guide set will be damaged.
6.Turn pattern adj. knob or air adj. knob counterclockwise to fully open. 6. If pattern adj.Knob or air adj. Knob are not fully opened, tip of it can contact
And then tighten pattern adj. set or air adj. set. and damage fluid nozzle and cause seizure of thread.
Where to inspect Parts replacement standard
1. Each hole passage of air cap and fluid nozzle Replace if it is crushed or deformed.
2. Packing and O ring Replace if it is deformed or worn out.
3. Leakage from seat section between fluid nozzle and fluid needle set Replace them if leakage does not stop after fully cleaning fluid nozzle and
fluid needle set.
If you replace fluid nozzle or fluid needle set only, fully match them
and confirm that there is no leakage.
WARNING
- First release air and pressure fully according to item No. 3 of “Improper use of equipment” of WARNING on page 2.
- Tip of fluid needle set has a sharp point. Do not touch the tip of needle valve during maintenance for protection of
the human body.
- Be careful not to damage the tip of the fluid nozzle or put your hand on it.
- Only an experienced person who is fully conversant with the equipment can do maintenance and inspection.
CAUTION
- Never use commercial or other parts instead of AIR GUINSA original spare parts.
- Never immerse the whole gun into liquid such as thinner.
- Never damage holes of air cap fluid nozzle or fluid needle.

Other Air Gunsa Paint Sprayer manuals

Air Gunsa AZ3 HTE2 User manual

Air Gunsa

Air Gunsa AZ3 HTE2 User manual

Air Gunsa AZ40 HTE AV User manual

Air Gunsa

Air Gunsa AZ40 HTE AV User manual

Air Gunsa AZ30 HTE 1.0 User manual

Air Gunsa

Air Gunsa AZ30 HTE 1.0 User manual

Air Gunsa AZ3 HTE User manual

Air Gunsa

Air Gunsa AZ3 HTE User manual

Air Gunsa AZ30 HTE User manual

Air Gunsa

Air Gunsa AZ30 HTE User manual

Air Gunsa AZ4 HTE-S User guide

Air Gunsa

Air Gunsa AZ4 HTE-S User guide

Air Gunsa AZ3 HTE2 AV User guide

Air Gunsa

Air Gunsa AZ3 HTE2 AV User guide

Air Gunsa AZ3 HTE2 User manual

Air Gunsa

Air Gunsa AZ3 HTE2 User manual

Air Gunsa AZ PVA User manual

Air Gunsa

Air Gunsa AZ PVA User manual

Air Gunsa AZ3 HTE2 User manual

Air Gunsa

Air Gunsa AZ3 HTE2 User manual

Popular Paint Sprayer manuals by other brands

Central Pneumatic 60314 Owner's manual & safety instructions

Central Pneumatic

Central Pneumatic 60314 Owner's manual & safety instructions

Glas Craft Probler P2 user manual

Glas Craft

Glas Craft Probler P2 user manual

wiwa HERKULES PFP Operation manual

wiwa

wiwa HERKULES PFP Operation manual

Toro 41228 installation instructions

Toro

Toro 41228 installation instructions

Ferm GUN - 120W Original instructions

Ferm

Ferm GUN - 120W Original instructions

Fimco 110-3PT-17N-XL owner's manual

Fimco

Fimco 110-3PT-17N-XL owner's manual

C-Dax SPRAYRIDER Generation 2 owner's manual

C-Dax

C-Dax SPRAYRIDER Generation 2 owner's manual

Birchmeier REA 15 AZ1 Instructions for use

Birchmeier

Birchmeier REA 15 AZ1 Instructions for use

WAGNER Vector Pro owner's manual

WAGNER

WAGNER Vector Pro owner's manual

Apollo PRECISION-5 PRO PLUS Maintenance Guide

Apollo

Apollo PRECISION-5 PRO PLUS Maintenance Guide

BARDI 790 Operation manual

BARDI

BARDI 790 Operation manual

Fimco UTL-40-12V owner's manual

Fimco

Fimco UTL-40-12V owner's manual

Earlex 6900 Operating instructions manual

Earlex

Earlex 6900 Operating instructions manual

Mi Swaco MONGOOSE PRO Installation and operation manual

Mi Swaco

Mi Swaco MONGOOSE PRO Installation and operation manual

Smithco SS1320 Parts & Service

Smithco

Smithco SS1320 Parts & Service

AG SPRAY BR-25-SP-EC owner's manual

AG SPRAY

AG SPRAY BR-25-SP-EC owner's manual

Graco H.E.L.P. 1600 Instructions-parts list

Graco

Graco H.E.L.P. 1600 Instructions-parts list

Earlex HV2501EU instruction manual

Earlex

Earlex HV2501EU instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.