manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Air King
  6. •
  7. Fan
  8. •
  9. Air King 9898L User manual

Air King 9898L User manual

1. Connect the black wire in the light fitter with the blue
wire marked “For Light” using the supplied wire nuts.
(Figure 8)
2. Connect the white wire in the
light fitter with the white wire
marked “For Light” using the
supplied wire nuts.
3. Tuck the wires and wire nuts into
switch cup. Lift the light fitter
into place and insert the three
screws and tighten.
4. Install light bulb (not included)
and lift globe into place and
secure with the three thumb
screws. Do not overtighten.
2. Place one of the phillips pan head screws into one of the
recessed holes in the blade bracket. Turn screw until it
mates with threaded hole in hub. Do not tighten screw
completely at this time. (Figure 7)
3. Install the second screw
in the same manner,
then tighten both screws
firmly.
4. Install the remaining
blade assemblies by
repeating the above
steps.
52" PORCH CEILING FAN
NOTE: The blades should be attached to the fan after it is
hung and wired to prevent blade brackets from being bent
and causing the fan to wobble.
BLADE ASSEMBLY AND ATTACHMENT INSTRUCTION MANUAL
Model 9898L
MAINTENANCE
Periodic cleaning of your ceiling fan is the only maintenance
that is needed. When cleaning, use only a soft brush or lint
free cloth to avoid scratching the finish. Abrasive cleaning
agents are not required and should be avoided to prevent
damage to the finish. Do not spray water directly onto your
ceiling fan. It could damage the motor or the blades and create
the possibility of an electrical shock or fire.
WARRANTY
The ceiling fan you have purchased is warranted by the
manufacturer for one year from the date of purchase against
defects in workmanship and/or materials. The motor is
warranted for ten years. This warranty means that only the
parts that prove to be defective during the period of warranty
will be either repaired or replaced at our option. The right is
reserved by the manufacturer to replace the whole product in
lieu thereof. Should repair become necessary during the
warranty period, write to: AIR KING c/o LASKO PRODUCTS,
INC., Appliance Service Department, 820 Lincoln Ave., West
Chester, PA 19380. Describe the problem you are having. DO
NOT SEND FAN!
This warranty does not apply if the damage occurs because of
accident, improper handling, installation or operation, shipping
damage, abuse, misuse or unauthorized repairs made or
attempted. ALL WARRANTIES, EXPRESSED OR IMPLIED LAST
FOR ONE YEAR FROM DATE OF ORIGINAL PURCHASE, EXCEPT
FOR THE MOTOR. THIS WARRANTY DOES NOT COVER LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY
CAUSE WHATSOEVER. Some states do not allow limitations on
how long any implied warranty lasts, or the exclusion or
limitations of incidental or consequential damages, so that the
above limitation or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may have
other rights that vary from state to state.
FOR REPLACEMENT PARTS: Please call 1-800-966-2028, Monday
- Friday, between the hours of 8am and 4 pm EST. Reference
the type and style of product when you call.
FOR QUESTIONS OR COMMENTS ABOUT YOUR CEILING FAN:
Please call 1-800-233-0268, Monday - Friday, between the hours
of 8am and 4pm EST.
New 11/00
Your new ceiling fan is UL listed for Damp locations and will
require a grounded electrical supply line of 120 volts AC, 60
Hz, 15 amp circuit. The 52" total fan weight is 26 lbs maximum.
WARNING: To reduce the risk of fire, electrical shock or personal
injury, mount fan at least 7 feet above the floor to an outlet
box marked “Acceptable for fan support.” Use screws provided
with outlet box. Most outlet boxes commonly used for the
support of lighting fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician
if in doubt.
Your ceiling fan will fit any of the following electrical boxes:
4" octagon box, 3" octagon box, 1/2" deep ceiling pan, or a
plaster ring with 3 1/2" mounting hole centers mounted on
one of the above listed boxes. Your new fan will also install on
a “wiremold” No. 5738 fixture box. The electrical box must be
securely anchored an capable of withstanding a load of at least
50 pounds.
If your ceiling fan does not have one of the above electrical
boxes for proper wiring, you may wish to contact a licensed
electrician for installation.
READ AND SAVE THESE INSTRUCTIONS
Remove the three shipping
stabilizer tabs from the
bottom of the fan. Remove Remove
1. Using three phillips washer head screws, secure one bracket
to each of the blades. Complete this assembly before
attaching blades to ceiling fan. (Figure 6)
Figure 6
Phillips Washer
Head Screw
Blade Bracket
Blade
Screws
Figure 7
Motor Hub
Blade
Bracket
Phillips Pan
Head Screw
USING YOUR CEILING FAN
1. Restore power to the electrical box.
2. Check the operation of the fan
by gently pulling the chain
switch.
3. To reverse airflow direction, turn
fan off and wait for the blades
to come to a full stop, then slide
reversing switch to opposite
position. (Figure 9)
4. Your ceiling fan is equipped
with four position, three speed
pull chain switch.
Figure 9
Reversing Switch
LIGHT KIT INSTALLATION
Figure 8
White
Wires
Blue
Wire
Black
Wire
Screw
Light
Fitter
Globe
1. Follow the recommended instructions for the proper method
of wiring your ceiling fan. If you do not know enough
about electrical wiring, have your fan installed by a licensed
electrician.
2. All wiring must satisfy National and Local electrical codes.
The ceiling fan must be grounded as a precaution against
possible electrical shock.
3. The electrical outlet box and joist must be securely mounted
and capable of reliably supporting at least 50 pounds.
4. WARNING: To reduce the risk of fire, electrical shock and/or
personal injury:
a) Be sure electricity is turned off at the main fuse box
before wiring, cleaning or servicing.
b) Fan should not be mounted in areas where it might
come in direct contact with water.
1. Be careful of the fan and moving blades when cleaning,
painting or working near fan.
2. Do not put anything into the blades while they are turning.
3. Do not bend the blade brackets when installing the brackets,
balancing the blades or cleaning the fan.
4. WARNING: The fan must be hung with at least 7 feet of
clearance from floor to blades.
RULES FOR SAFE INSTALLATION
RULES FOR SAFE OPERATION
1. Attach the hanger bracket to the electrical box capable
of reliably supporting at least 50 pounds. Insert the screws
through the slotted holes in the bracket and attach to the
electrical box. Tighten both screws to the electrical box.
(Figure 1)
NOTE: If bracket and/or electrical box are not securely attached,
the fan could wobble.
INSTALLATION INSTRUCTIONS
WARNING: Failure to completely install the cotter pin or tighten
the set screw could result in the fan loosening and possibly
falling.
NOTE: Check to see that all connections are tight, including
the ground and that no bare wire is visible at the wire nuts,
except for the ground wire.
8. Raise canopy up to mounting bracket and fit screws into
slots on canopy and rotate to the left to lock into place.
Tighten both screws. (Figure 5)
NOTE: Make sure that the electrical wires are completely inside
the electrical box and not pinched between the ceiling canopy
and the ceiling.
Figure 4
White Fan
(Neutral)
Black Fan
(Hot)
Green Jumper
Wire
Supply Ground
Green or Bare Black Supply
(Hot) White Supply
(Neutral)
Figure 1
Screw
Electrical Box
Mounting
Bracket
3. Carefully lift the fan and seat the pipe flange and ball
assembly on the hanger bracket that was just attached to
the electrical box. Be sure the notch on the side of the ball
is lined up with tab on the hanger bracket. (Figure 3)
WARNING: Failure to seat tab on bracket into notch on ball
could cause damage to electrical wires and cause fan to fall.
NOTE: Do not pinch wires between the ball and pipe flange
assembly and hanger bracket.
Figure 2
Pipe Flange
Yoke Cross Pin
Cotter Pin
Canopy
Set Screw
Cotter Pin
4. Make sure the electrical box is properly secured. If romex
cable (plastic sheathed) was used to wire the electrical box,
the presence of a third wire connected to the electrical
box indicates that the box is grounded. This ground wire
may be bare wire (no insulating jacket), or a green insulated
wire. The two supply wires will be white and black insulated
wires.
5. If the wiring to the electrical box is enclosed in electrical
conduit pipe, the ground wire may not be present. The
conduit itself could serve as the ground.
GROUNDING:
6. Romex (plastic sheathed) Cable: If romex cable was used
to wire the electric box, connect the green ground wire
attached to the hanger ball and the green ground wire in
the Romex cable using a 72B listed wire nut.
6a. Conduit Pipe: If the wiring to the electrical box is enclosed
in electrical conduit pipe, connect the ground wire to the
ground screw in the electrical box.
Figure 3
NOTE: Ceiling canopy
supply wires and fan wires
omitted from figure for
clarity Electrical Box
Pipe Flange
Assembly
7. Electrical Supply: Connect the fan motor white wire to the
supply white (Neutral) wire using a listed wire nut. Connect
the fan motor black wire and blue wire to the supply black
(hot) wire using a listed wire nut. Your fan is now wired
to be turned on and off from the fan (pull chain) switch.
(Figure 2) With wire nuts turned upward, place green and
white connections to one side of box and blue and black
connections towards the other side and push carefully up
into outlet box.
2. Install motor leads through the canopy then through the
hole in the center of the pipe flange. Insert downrod into
downrod yoke. Make sure to align hole in downrod with
hole in downrod yoke. Lift canopy and install yoke cross
pin through yoke and downrod. Insert cotter pin into cross
pin until it snaps into place. Using a phillips head screwdriver
firmly tighten set screws in yoke. (Figure 2) Figure 5
Screw
Canopy
Mounting
Bracket

Other Air King Fan manuals

Air King 9124 User manual

Air King

Air King 9124 User manual

Air King AK863FL User manual

Air King

Air King AK863FL User manual

Air King AK965 User manual

Air King

Air King AK965 User manual

Air King FRAK110 User manual

Air King

Air King FRAK110 User manual

Air King AK50S User manual

Air King

Air King AK50S User manual

Air King AK100FL User manual

Air King

Air King AK100FL User manual

Air King EWF-180 User manual

Air King

Air King EWF-180 User manual

Air King AIDB4Y User manual

Air King

Air King AIDB4Y User manual

Air King 9525 Service manual

Air King

Air King 9525 Service manual

Air King AKZA130 User manual

Air King

Air King AKZA130 User manual

Air King AKLC701 User manual

Air King

Air King AKLC701 User manual

Air King 9842 User manual

Air King

Air King 9842 User manual

Air King BFQ90 User manual

Air King

Air King BFQ90 User manual

Air King 9020 User manual

Air King

Air King 9020 User manual

Air King BFQF70 User manual

Air King

Air King BFQF70 User manual

Air King 9236D User manual

Air King

Air King 9236D User manual

Air King ASF70 User manual

Air King

Air King ASF70 User manual

Air King AKA130 Owner's manual

Air King

Air King AKA130 Owner's manual

Air King AK100D User manual

Air King

Air King AK100D User manual

Air King 4C630N/9012N Instructions for use

Air King

Air King 4C630N/9012N Instructions for use

Air King IL Series User manual

Air King

Air King IL Series User manual

Air King AK200LS Owner's manual

Air King

Air King AK200LS Owner's manual

Air King Exhaust Fan AS70 User manual

Air King

Air King Exhaust Fan AS70 User manual

Air King AK150LS Series User manual

Air King

Air King AK150LS Series User manual

Popular Fan manuals by other brands

Vortice VORT QUADRO dMEV Instruction booklet

Vortice

Vortice VORT QUADRO dMEV Instruction booklet

Vornado VFANMC VFAN MINI CLASSIC instruction manual

Vornado

Vornado VFANMC VFAN MINI CLASSIC instruction manual

kincrome KP1005 manual

kincrome

kincrome KP1005 manual

Casablanca Campana owner's manual

Casablanca

Casablanca Campana owner's manual

Hoffrichter CARAT I Service manual

Hoffrichter

Hoffrichter CARAT I Service manual

aerauliqa QXD installation manual

aerauliqa

aerauliqa QXD installation manual

Modern Forms Renegade 52 installation instructions

Modern Forms

Modern Forms Renegade 52 installation instructions

Judge JEA53 instruction manual

Judge

Judge JEA53 instruction manual

Draper 08710 user manual

Draper

Draper 08710 user manual

Vents TwinFresh Style Wi-Fi user manual

Vents

Vents TwinFresh Style Wi-Fi user manual

DuraVent DuraTech Canada Installation and operation instructions

DuraVent

DuraVent DuraTech Canada Installation and operation instructions

Wagan 12V Fan/Defroster user manual

Wagan

Wagan 12V Fan/Defroster user manual

Emerson PREMIUM CF4800WW03 owner's manual

Emerson

Emerson PREMIUM CF4800WW03 owner's manual

Bimar VP455T Instruction booklet

Bimar

Bimar VP455T Instruction booklet

NuTone 761WHNT 761WHNT instructions

NuTone

NuTone 761WHNT 761WHNT instructions

Quest Engineering F9 Installation, operation and maintenance instructions

Quest Engineering

Quest Engineering F9 Installation, operation and maintenance instructions

Supra HEOLE manual

Supra

Supra HEOLE manual

Black & Decker BDHV2002 Use and care book

Black & Decker

Black & Decker BDHV2002 Use and care book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.