air sniper Spectrum-800 User manual

1
Air Sniper
Spectrum-800
USER MANUAL

2
A WORD TO AIR SNIPER OWNERS
At Air Sniper, we design and build supplemental air sanitization systems with complete
customer satisfaction in mind. To assure trouble-free operation of your Air Sniper system,
please read this manual and follow installation recommendations.
An authorized Air Sniper dealer will know the system best, and if service or maintenance
is needed, the Air Sniper team is here to help. Our team is dedicated to providing you with
the best possible service and assuring your satisfaction with our product.
For any questions or service requirements, please contact an Air Sniper representative at
the toll-free number: 1-888-338-9549

3
IMPORTANT SAFETY INSTRUCTIONS
WARNING: NEVER EXPOSE SKIN OR EYES TO UV LAMP WHEN OPERATING
Read and follow all instructions prior to installation. Read the directions and all safety labels
prior to operation. Failure to follow any instructions or labels may result in injury of the user or
damage to the unit. Save this manual for future reference.
1. The Spectrum-800 Unit is intended to be used
for air sanitization inside of a sealed air
chamber. Do Not attempt to operate the UV-C
Lamps outside of a sealed housing.
2. Electrical shock may cause Injury or possible
death. Ensure that the unit is turned off and
disconnected from the power source prior to
installation or replacement.
3. Untrained personnel can perform installation and
replacement of the unit as per the Instructions
within this manual. Do Not attempt to perform
any maintenance on your unit. Improper
maintenance can result in damage to the unit
and injury of the user. If your unit requires
maintenance, please contact Air Sniper.
Replacement of the UV-C emitter by an
untrained professional is not allowed.
4. Do Not attempt to modify your unit. Modification
of this unit may result in injuries to the user or
damage to the unit.
5. Inspect your unit for any abnormalities or
damage prior to installation and use. Damaged
units can result in harmful UV-C leaks. Units that
are obviously damaged must not be operated.
6. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a
hazard.
7. This appliance contains a UV-C emitter. UV-C
lamps contain small amounts of mercury
amalgam. If the lamp is broken or damaged,
clean and dispose of it properly as per local
safety regulations.
8. The Spectrum-800 unit is not to be used by
persons (including children) with reduced
physical, sensory or mental capabilities, or a
lack of experience and knowledge, unless
properly supervised. Children shall be supervised
so that they do not to play with the unit.
9. It is recommended a minimum of two people
present when installing the unit. Units can be
heavy and require care and precision when
installing.
10. Air Sniper products are not waterproof. Do Not
attempt to use your unit in a wet environment.
11. Air Sniper products are designed for INDOOR
USE ONLY. Do Not attempt to install your unit
outdoors.
12.The use of this device is a supplement to and
not a substitute for standard infection control
practices; users must continue to follow all
current infection control practices related to
cleaning and disinfection of environmental
surfaces.
13. The Spectrum-800 Unit does not require cleaning
to continue to operate effectively.
14. FIRST AID INSTRUCTIONS: If Injury occurs,
contact your doctor or appropriate emergency
services.
15. WARNING: UV RADIATION EMITTED FROM
THIS DEVICE. Unintended use of the appliance
or damage to the housing may result in the
escape of dangerous UV-C radiation. UV-C
radiation may, even in small doses, cause harm
to the eyes and skin.

5
ABOUT THE SPECTRUM-800 UNIT
Thank you for purchasing the Air Sniper Spectrum-800 supplemental air sanitizing unit.
Following installation, you will be able to enjoy air sanitization that is proven to kill
99.99% of airborne contaminants from the air passing through the unit, while producing
no ozone. All Air Sniper products are tested and verified in independent laboratories and
are 100% made in North America. Find the test results here: https://airsniper.ca/test-
results/
For more information on the Spectrum-800 unit and all other Air Sniper products and
services, call 1-888-338-9549 to speak to one of our representatives, or email Air
Sniper at info@airsniper.ca with any questions that you may have.
DESIGN
The Spectrum-800 is made up of several key components listed below.
The Spectrum-800 unit is designed for supplemental air purification in occupied spaces
such as: classrooms, office spaces, or communal living areas.
1. LED Indicators
2. Display Screen
3. On/Off Switch
4. Merv 8 Air Filter

6
FEATURES
-300 Watt UV-C induction bulb
-Bluetooth enabled
-Whisper quiet
-Up to 10 year lifespan
-10 Fan speeds
SPECIFICATIONS
-Power Supply
110 V 50/60 Hz
-Energy Consumption
6 A @ 110 V Maximum
-Operating Temperature Range
-25°C / 100°C
-Power control Systems
On/Off switch, airflow differential pressure switch/sensor
-Bulb Life
55,200 Bulb life hours of high intensity UVC
-Electrical Safety Certification
ETL certified for USA and Canada
-Ozone Compliance
UL 867 (the bulb meets the requirements of UL 2998)
-Weight
75 lbs (34 kg)
-Dimensions
42.5" (H) x 24.5" (W) x 19" (D)
-Noise
21-47 dB
-Monitoring
Bluetooth functionality for remote scheduling and monitoring
-Housing Material
White powder coated aluminum

7
INCLUDED PARTS
Included in the package you will find:
1. Air Sniper Spectrum-800 unit
2. 10’ Power cable
3. AC Infinity fan user manual
4. MERV 8 filter
1
2
3
4

8
DIRECTIONS FOR USE
To operate the Air Sniper Spectrum-800 unit,
1. Connect the supplied power cable to the unit. The connector end for the cable is
found on the back of the unit.
2. Insert the MERV8 air filter from the front ensuring that the direction of the filter is
correct. To ensure this make sure that the metal edges inside the filter are facing
upwards.

9
3. The other end of the power plug should next be plugged into a 110V AC
receptacle. If required an extension cable can be used to extend the distance
from the power receptacle. Please note that the Spectrum-800 is for use with
110V AC only.
4. Turn on the unit using the switch on the front of the unit.
5. Adjust the fan speed to the desired level.
6. Additional programming features can be found in the AC Infinity fan user manual.
BULB STATUS
The Lamp Operating LED will glow three different colors, indicating different bulb status.
The variations are as follows:
-Green: Lamp operating, the lamp is operating as intended
-Yellow: Lamp life warning, the lamp is nearing the end of its lifespan, requires
replacement in near future
-Red: Lamp life exceeded, lamp has reached the end of its lifespan, requires -
immediate replacement
When the Lamp Operating LED color is yellow, please contact your local distributor or
Air Sniper directly for a replacement. The Spectrum-800 is designed to sanitize in an
environment with an airflow of as little as 80 CFM to a maximum of 800 CFM.
FILTER REPLACEMENT
The Air Sniper Spectrum-800 uses a MERV 8 air filter that is sized at 10” by 18” by 1”,
and Air Sniper recommends changing of this once every three (3) months. These filters
can be purchased locally or ordered online.
The Air Sniper Spectrum-800 warranty and performance specifications are only
applicable to users who consistently use a MERV 8 air filter in their Spectrum-800. All
other air filters are not capable of filtering the level of particulates required by the
Spectrum-800.

10
TROUBLESHOOTING
If your unit is not operating as expected, there are several steps you can take to attempt
to correct the problem.
WARNING: Do Not attempt to operate the UV-C lamp outside of the unit. UV-C
radiation is extremely harmful to unprotected skin and eyes.
If the Bulb is not operating:
-Inspect the unit and the power cable to verify nothing appears damaged.
-Check that the selected power source is providing power for the unit.
- Check that both ends of the 10’ power cable are securely connected to either the
unit or the power source.
-Check that the On/Off switch is flipped to the on position.
-Once airflow is established, the lamp indicator light will be lit.
If the Lamp Operating LED is Red, the bulb has expired. Contact your local distributor or
Air Sniper to replace the unit.
REPLACING YOUR UNIT
The Air Sniper Spectrum-800 unit uses a built in 300W UV-C lamp with a lifetime of 6+
years (55,200 hours, based on 24/7 operation). To track the life of the lamp on your unit,
check the bulb status LED Color when the unit is activated to determine the state of
your unit. It is strongly recommended that the unit be replaced when the lamp life
warning LED is illuminated (LED glows yellow). When the lamp life has been exceeded
(LED glows red), the entire unit will need to be replaced. Contact your local distributor or
Air Sniper to order replacement units.

11
WARRANTY
Limited Five Year Warranty
Alpine Innovative Research Inc. (AIR) warrants the Air Sniper™ to be free from defects
in the workmanship or materials under normal use and service (the “Warranty”) for a
period of five (5) years (the “Warranty Period”) from the date of purchase through an
AIR-authorized dealer/distributor. During the Warranty Period, should an Air Sniper™
be determined to be defective, AIR shall repair or replace the defective Air Sniper™
unit(s) (at AIR or dealer’s option) within a reasonable period.
Remedy Procedures
If the Air Sniper™ proves defective within the Warranty Period, the purchaser may
choose one of the following remedies, after contacting AIR for a Return Authorization
Number: 1. Return the defective Air Sniper™ unit to the dealer/distributor from whom it
was purchased together with a copy of the bill of sale, or dated proof of purchase
thereof and the Return Authorization Number; or 2. Ship the defective Air Sniper™ unit
directly to Air Alpine Innovative Research customer warranty department along with the
Return Authorization Number.
Limitations
This Warranty is the only representation regarding the Air Sniper™, by Alpine
Innovative Research Inc. of merchantability and fitness for use and shall extend to five
(5) years from the date of purchase. If it is determined by either Alpine Innovative
Research Inc. or an authorized dealer/distributor that the defect is the result of damage
caused by the purchaser, the Warranty is null and void.
Contact Us Any questions or concerns pertaining to this Warranty may be directed to Air
Sniper by E-mail, telephone, or facsimile: AIR, Alpine Innovative Research.
Customer Warranty Department
Bay 11, 6565 40th Street SE Calgary, Alberta, Canada, T2C 2J9
Toll Free: 1-888-338-9549
Email: service@airsniper.ca
Other manuals for Spectrum-800
1
Table of contents
Other air sniper Water Filtration System manuals