airinspace Wall-i CO2 User manual

User manual –Wall-i CO2–Ed 01_28_October_2021
Wall-i CO2
CO2sensor
USER MANUAL
Wall-i CO2
European Low Voltage Directive (LVD) 2014/35/EU
European Electromagnetic Compatibility Directive (EMC) 2014/30/EU

User manual –Wall-i CO2–Ed 01_28_October_2021
1 /12
WARNING
We strongly recommend that you read the entire manual before putting the Wall-i CO2into operation for the first
time.
PACKAGE CONTENTS
•1 Wall-i CO2Unit.
•1 Box bracket
•1 Micro USB type B power supply with universal plug.
•1 fixing set (nylon plugs + screws).

User manual –Wall-i CO2–Ed 01_28_October_2021
2 /12
TABLE OF CONTENTS
SECTION 1 - GENERAL INFORMATION............................................................................................................3
1.1 Safety instructions ............................................................................................... 3
1.2 Regulatory standard ............................................................................................. 4
1.3 Normative standards ............................................................................................ 4
1.4 Classification ........................................................................................................ 4
1.5 Description of the device ...................................................................................... 5
1.5.1 Overview......................................................................................................... 5
1.5.2 Markings and warnings........................................................................................ 5
1.6 Functional description of the device ..................................................................... 6
1.6.1 Intended use.................................................................................................... 6
1.6.2 Operating principles ........................................................................................... 6
1.6.3 Physical characteristics ....................................................................................... 6
1.7 Instruction ........................................................................................................... 6
1.8 Disposal................................................................................................................ 6
SECTION 2 - INSTALLATION/USE.....................................................................................................................7
2.1 Installation ........................................................................................................... 7
2.2 Start-up .............................................................................................................. 10
2.2.1 Use ..............................................................................................................10
2.2.2 Calibration procedure.........................................................................................11
2.3 Distributor warranty........................................................................................... 12
2.4 Model identification ............................................................................................ 12

User manual –Wall-i CO2–Ed 01_28_October_2021
3 /12
SECTION 1 - GENERAL INFORMATION
1.1 SAFETY INSTRUCTIONS
•READ THESE INSTRUCTIONS THOROUGHLY and strictly follow the chronological order of
installation and start-up operations.
•The device must be used at temperatures from +5°C to +35°C, with relative non-condensing
humidity lower than 99%, with dust levels of less than 0.1 mg/m3.
•Do not allow any liquid to penetrate the device.
•When cleaning, only use a dry cloth.
•Do not place the device near a heat source.
•Do not block the vents of the box while in operation.
•Do not twist, stretch or damage the power supply cable.
•Make sure the power pack is accessible so that it can be disconnected if necessary.
•Only connect the device to earthed sockets that meet legal requirements and are inspected
periodically.
•Unplug the device when not in use for extended periods.
•Avoid knocks as they could damage the device.
IMPORTANT: BEFORE CARRYING OUT ANY WORK ON AN ELECTRICAL COMPONENT, SWITCH OFF
THE DEVICE BY DISCONNECTING IT FROM THE MAINS.
IMPORTANT: WORK ON WALL-I CO2(INCLUDING ELECTRICAL CIRCUITS, ELECTRONIC CARDS)
MUST ONLY BE CARRIED OUT BY airinspace®MAINTENANCE PERSONNEL OR DULY
TRAINED PERSONNEL.

User manual –Wall-i CO2–Ed 01_28_October_2021
4 /12
1.2 REGULATORY STANDARD
Wall-i CO2 devices are CE-marked and comply with European regulations:
European Low Voltage Directive (LVD) 2014/35/EU
European Electromagnetic Compatibility Directive (EMC) 2014/30/EU
1.3 NORMATIVE STANDARDS
•NF EN 61010-1 (2011). Safety requirements for electrical equipment for measurement, control
and laboratory use. Part 1: General requirements.
•EN 61326-1 (2013). Electrical equipment for measurement, control and laboratory use - EMC
requirements - Part 1: General requirements
•NF S 90351 (2013). Healthcare establishments - Clean rooms and associated controlled
environments. Requirements relating to the control of airborne contamination.
1.4 CLASSIFICATION
Type of protection against electric shocks
Class III
The unit operates on SELV (5Vcc).
Level of protection of applied parts against
electric shocks
No applied parts
Degree of protection against water and solids
IP 20
Operating mode
Continuous service
Operation under normal conditions of an unlimited duration without
exceeding operating temperature limits.
Level of safety when used in the presence of
flammable anaesthetics mixed with air,
oxygen or nitrous oxide
Device not suitable for use with flammable anaesthetics mixed with air,
oxygen or nitrous oxide.
Wall-i CO2is not an AP or APG category medical device. It must always be
kept more than 25 cm from the point where there is a mixture of flammable
anaesthetic with air, oxygen or nitrous oxide. The user is therefore
responsible for positioning Wall-i CO2accordingly in the room to be treated.
Electromagnetic interference
EN 61326-1 class B standard for conducted and radiated
disturbances.
Wall-i CO2is suitable for operation in an environment consisting of devices
which meet equivalent criteria.

User manual –Wall-i CO2–Ed 01_28_October_2021
5 /12
1.5 DESCRIPTION OF THE DEVICE
1.5.1 OVERVIEW
1.5.2 MARKINGS AND WARNINGS
1
Painted plastic housing
2
Touchscreen
3
Air intake vents
4
USB power supply
Label
Description
Position
Product –serial number
On the back of the product
2
1
4
3

User manual –Wall-i CO2–Ed 01_28_October_2021
6 /12
1.6 FUNCTIONAL DESCRIPTION OF THE DEVICE
1.6.1 INTENDED USE
The Wall-i CO2 is a sensor that measures CO2concentration. It is used in buildings where air quality
needs to be controlled, such as schools, offices, meeting rooms and, as a result, gives an indication as
to the level of CO2 in the room where it is installed. It constitutes a health measure that supplements
protective measures.
1.6.2 OPERATING PRINCIPLES
The Wall-i CO2 is mounted to the wall or placed on a flat surface. CO2 molecules are collected and
counted, and the screen displays an indicative value in ppm (parts per million). The colour of the screen
(green, yellow, red) tells the user whether the CO2 concentration complies with “recommended”
thresholds.
1.6.3 PHYSICAL CHARACTERISTICS
Power supply
90-264V; 47-63 Hz / 5.1V -13W 2.5A
Water/solids protection index
Complete device
IP20
Control panel
Overall dimensions
H 87.5 x W 60.8 x D 26 mm
Weight
70g
Environmental operating range
Temperature
+5 °C to +35 °C
Relative humidity
< 95% non-condensing
Environmental storage range
Temperature
0°C to 45°C
Relative humidity
20% to 90%
Dust level
< 1 mg/m3
Note: The information contained in this table is for information only. For any information on
measurements and tolerance intervals, please contact airinspace®at the address given at the
end of this document.
1.7 INSTRUCTION
The unit must be protected from direct sunlight, heat sources, frequent changes in temperature and
humidity, potentially corrosive chemicals or other products.
1.8 DISPOSAL
This product is covered by European Directive 2012/19/EU of 4 July 2012 on waste electrical and
electronic equipment (WEEE) and falls within category 6. “Electrical and electronic tools” as defined in
annex I to this directive.
Disposal of this product and the recovery of the resultant waste must respect regulations arising from the
application of the European directive by the different member states, as well as any local regulations that
complement it.

User manual –Wall-i CO2–Ed 01_28_October_2021
7 /12
SECTION 2 - INSTALLATION/USE
2.1 INSTALLATION
The Wall-i CO2is initially designed to be mounted to a wall. It can however be placed on a support
(shelf, cabinet, desk, etc.)
Wall bracket installation procedure: Screw fastening
The unit comes with a fixing kit including 2 nylon plugs for concrete, plaster or plasterboard walls and 2
screws.
▪Using a drill and a 5mm diameter concrete drill bit, drill two holes in the desired location, 50
millimetres apart. Or use the bracket as a template
▪Install the plugs using a hammer
▪Loosen the safety screw of the box supplied to secure the bracket to the wall.
▪Position the box bracket opposite the drilling holes and tighten the screws until they are flush
with the box.

User manual –Wall-i CO2–Ed 01_28_October_2021
8 /12
.
Wall bracket installation procedure: Double-sided fastening.
▪Apply double-sided tape to the back of the bracket in order to fix it to the wall in the desired
location.
Once the wall bracket has been fastened,
▪Run the cable through the cut-out, and pull it out towards the inside of the bracket.
▪Connect the USB cable to the box and place the Wall-i CO2 on the cut-out of the bracket
provided for this purpose.

User manual –Wall-i CO2–Ed 01_28_October_2021
9 /12
▪Tighten the tamper-resistant screw to secure the Wall-i CO2 to its bracket.

User manual –Wall-i CO2–Ed 01_28_October_2021
10 /12
2.2 START-UP
Connect the transformer in the Wall-i CO2 package to a mains socket:
100-240V ~ 50/60 Hz.
Connect the USB cable to the box.
IMPORTANT: THE POWER PLUG MUST COMPLY WITH REGULATORY
REQUIREMENTS AND BE PERIODICALLY CHECKED.
2.2.1 USE
On starting up, the main screen displays the CO2 concentration value of the room via a ppm counter.
This counter is in green as long as the CO2rate indicated is below 800 ppm; it turns yellow once the
rate exceeds 800 ppm, which means that the room must be ventilated and action must be taken in
terms of air change and/or reducing the number of people in the room. If the red threshold is exceeded,
it is recommended to evacuate the room.

User manual –Wall-i CO2–Ed 01_28_October_2021
11 /12
2.2.2 CALIBRATION PROCEDURE
The Wall-i CO2can be calibrated on this screen..
To display the secondary screen, press the icon. Press the button to launch the
calibration, which will take 10 minutes.
IMPORTANT: DO NOT OBSTRUCT THE AIRFLOW OUTLET, OTHERWISE YOU MAY
OBTAIN INCORRECT RESULTS AND THE UNIT MAY BE DAMAGED.
Note: The Wall-i CO2is factory-calibrated and an automatic calibration is performed every week.
Only perform the calibration procedure if there is any doubt about the values displayed.

User manual –Wall-i CO2–Ed 01_28_October_2021
12 /12
2.3 DISTRIBUTOR WARRANTY
Contact your local airinspace® dealer.
Note: any problems arising from an unauthorised repair attempt, modification, fall, use at incorrect
voltage or operations that do not comply with the instructions in the User Manual are not covered by the
warranty.
2.4 MODEL IDENTIFICATION
When contacting airinspace®or a dealer, please provide the Wall-i CO2unit’s serial number and
date of purchase:
CONTACT airinspace®
airinspace® S.E.
14, Rue Jean Monnet
78990 Elancourt
France
+33 1 30 07 01 01
+33 1 30 07 01 02
www.airinspace.com
Table of contents
Popular Security Sensor manuals by other brands

CIAS Elettronica S.r.l.
CIAS Elettronica S.r.l. MWDT installation manual

ADEMCO
ADEMCO 11BR Installation instruction

BW Technologies
BW Technologies Quattro Technical reference guide

Honeywell
Honeywell BW Ultra Quick reference guide

Riken Keiki
Riken Keiki SD-1DOX-AS operating manual

Johnson Controls
Johnson Controls PG9200AX user manual

jablotron
jablotron JA-160PC manual

INIM Electronics
INIM Electronics ODI100H Installation and programming manual

Optex
Optex fit Series installation instructions

Visonic
Visonic DUET-AM C/O Installer's guide

Isimet
Isimet RLA Series Installation, Maintenance, Operations, and Start-up Instructions

B.E.G.
B.E.G. LUXOMAT net PD2N-KNX-DX Mounting instructions