CONTENTS
»Introducon
»Safety Precauons
»Pre-Installaon
»Installaon
»Operaon
»Maintenance
»Troubleshoong
»Warranty
Airius, LLC (Manufacturer)
811 South Sherman St.
Longmont, Colorado 80501 - USA
Toll free: 1-888-247-7327
Telephone: 303-772-2633
Fax: 303-772-8276
Web: www.airiusfans.com
May be covered by one or more of the following
United States Patents:7,381,129 B2; D514688
and other patents pending
AIRIUS®, AIR PEAR®, AIRIUS PUREAIR®,
PEARLINK®, and THE THERMAL EQUALIZER®
are trademarks of Airius, LLC, registered in
the U.S. and in some countries abroad. Other
trademarks pending in the U.S. and abroad.
NOTE: Carefully check fans/controls for shipping
damage. Report any damage to the carrier
immediately. Do not aempt to operate if visible
damage is evident to either the circuit or to the
electronic components. All informaon contained
in this manual is intended to be correct, however
informaon and data in this manual are subject to
change without noce. Airius makes no warranty
of any kind with regard to this informaon or
data. Further, Airius is not responsible for any
omissions or errors or consequenal damage
caused by the user of the product. Airius reserves
the right to make manufacturing changes that
may not be included in this manual.
Delta T EC Control Installaon Guide: V1.1
©2023 Airius, LLC.
Introducon
Congratulaons on the purchase of an Airius fan
system. Our patented, American-made, air-mixing
system will ensure beer thermal comfort in
both the summer and winter while driving down
expensive energy bills. We are here to support
you and if you have any quesons or comments,
we can be contacted through our website,
airiusfans.com, or give us a call: 1-888-247-7327.
About the Airius Delta-T EC Control
Airius Delta-T EC controls allow for 5 modes
of operaon: 24 hr mer, automac Delta
T Control, thermostat control, humidistat
control and manual mode. Automacally take
control of stracaon in your space using the
supplied ceiling/oor temperature sensors. The
control output is 0-10VDC making this control
compable with all Airius EC motor opons. For
Airius shaded pole or slit-capacitor fans, please
refer to the Airius Delta-T AC controller.
Operang Temperature: 15 to 150˚F
Humidity Range: 10 to 99% RH (non-condensing)
Power Input: 24VDC
Power Output: 0-10VDC
Communicaon Wiring: 4 conductor 22-24AWG
Interface Display Type: LCD
Units: Fahrenheit or Celsius
High Sensor: Air Temperature and humidity
Low Sensor: Air Temperature and humidity
Limitaons: Max distance of 82 between
interface and sensors.
Only for use indoors.
What’s In the Box
Each Delta T EC Control package includes:
• 24VDC Power Supply
• Control interface
• (2) temperature sensors
What You Will Need
• Phillips screwdriver
• 2x4 job box for wall mounted control
• 2x4 job box for each temperature sensor
• Conduit for wire runs
• Twisted pair cable (4 conductors)
• 2 Conductor signal/control cable