Airline DB038 User manual

•The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample
may be said to have been obtained.
•This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability
are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any
loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or one of its
marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced
from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek
certification program.
•For Terms And Conditions of the services, it can be provided upon request.
•The evaluation data of the report will be kept for 3 years from the date of issuance.
TRF No.: FCC 15C_Tx_b
Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch
6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China
Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com
Airline Mechanical Co., Ltd
Application
For
Certification
FCC ID: ZGIDA065
Remote wall switch with Z-WAVE
Model: DB038
Additional Model: DA065, ZFM-80US, ZFM-M80US
Transceiver
Report No.: SZ12060359-1
We hereby certify that the sample of the above item is considered to comply with the
requirements of FCC Part 15, Subpart C for Intentional Radiator,
Mention 47 CFR [
10-1-11
]
Prepared and Checked by: Approved by:
Sign on file
Andy Yan
Engineer Billy Li
Supervisor
Date: July 14, 2012
Digitally signed
by Billy Li
Location: Intertek
Testing Services

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
i
LIST OF EXHIBITS
INTRODUCTION
EXHIBIT 1: General Description
EXHIBIT 2: System Test Configuration
EXHIBIT 3: Emission Results
EXHIBIT 4: Equipment Photographs
EXHIBIT 5: Product Labelling
EXHIBIT 6: Technical Specifications
EXHIBIT 7: Instruction Manual
EXHIBIT 8: Miscellaneous Information
EXHIBIT 9: Test Equipment List

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
ii
MEASUREMENT/TECHNICAL REPORT
Airline Mechanical Co., Ltd
- Model: DB038
Additional Model: DA065, ZFM-80US, ZFM-M80US
FCC ID: ZGIDA065
July 14, 2012
This report concerns (check one:) Original Grant X Class II Change
Equipment Type: DXT - Part 15 Low Power Transceiver, RX Verified
Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X
If yes, defer until:
date
Company Name agrees to notify the Commission by:
date
of the intended date of announcement of the product so that the grant can be issued on that
date.
Transition Rules Request per 15.37? Yes No X
If no, assumed Part 15, Subpart C for intentional radiator −the new 47 CFR [10-1-11
Edition] provision.
Report prepared by:
Billy Li
Intertek Testing Services Shenzhen Ltd.
Kejiyuan Branch
6F, Block D, Huahan Building, Langshan Road,
Nanshan District, Shenzhen, P. R. China
Phone: (86 755) 8601 6288
Fax: (86 755) 8601 6751

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
iii
Table of Contents
1.0 General Description............................................................................................2
1.1 Product Description............................................................................................2
1.2 Related Submittal(s) Grants ...............................................................................2
1.3 Test Methodology...............................................................................................3
1.4 Test Facility........................................................................................................3
2.0 System Test Configuration.................................................................................5
2.1 Justification........................................................................................................5
2.2 EUT Exercising Software....................................................................................5
2.3 Special Accessories...........................................................................................5
2.4 Equipment Modification......................................................................................5
2.5 Measurement Uncertainty ..................................................................................6
2.6 Support Equipment List and Description.............................................................6
3.0 Emission Results................................................................................................8
3.1Radiated Test Results…………………………………………………………………. 9
3.1.1 Field Strength Calculation................................................................................9
3.1.2 Radiated Emission Configuration Photograph................................................10
3.1.3 Radiated Emissions.......................................................................................10
3.1.4 Transmitter Spurious Emissions (Radiated)…………………………………….. 12
3.2 Conducted Emission at Mains Terminal…………………………………………… 14
3.2.1 Conducted Emissions Configuration Photograph………………………………..14
3.2.2 Conducted Emissions………………………………………………………………14
4.0 Equipment Photographs...................................................................................18
5.0 Product Labelling..............................................................................................20
6.0 Technical Specifications...................................................................................22
7.0 Instruction Manual ............................................................................................24
8.0 Miscellaneous Information ...............................................................................26
8.1 Bandedge Plot .................................................................................................27
8.2 Emissions Test Procedures..............................................................................29
9.0 Test Equipment List..............................................................................................32

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
iv
List of attached file
Exhibit type File Description Filename
Test Report Test Report report.pdf
Test Setup Photo Radiated Photos radiated photos.pdf
Test Setup Photo Conducted Photos conducted photos.pdf
Test Report Bandedge Plot bandedge.pdf
Test Report 20dB BW Plot bw.pdf
External Photo External Photo external photos.pdf
Internal Photo Internal Photo internal photos.pdf
Block Diagram Block Diagram block.pdf
Schematics Circuit Diagram circuit.pdf
Operation Description Technical Description descri.pdf
ID Label/Location Label Artwork and Location label.pdf
User Manual User Manual manual.pdf
Cover Letter Letter of Agency agency.pdf

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
1
EXHIBIT 1
GENERAL DESCRIPTION

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
2
1.0 General Description
1.1 Product Description
The Equipment Under Test (EUT) is a Remote wall switch with Z-WAVE
transceiver connected directly to AC 120V/60Hz main line. The EUT is a
remote controlled On/Off switch for household appliance and it is designed to
act as a repeater, which will re-transmit the 908.42MHz RF signal (when
receive a command signal from the remote controller) to ensure that the
signal is received. It also has manual function. For more detail, please refer to
the user manual.
The Model: ZFM-M80US is the same as the Model: DB038 in hardware
aspect. The models are difference in plastic colour, packaging and marketing
purpose only.
The Models: DA065, ZFM-80US are the same as the Models: DB038 in
hardware aspect of RF portion. The difference between the models is as
below.
DB038, ZFM-M80US with power meter function.
DA065, ZFM-80US without power meter function.
Antenna Type: Integral antenna
Modulation Type: FSK
For electronic filing, the brief circuit description is saved with filename: descri.pdf.
1.2 Related Submittal(s) Grants
This is an application for certification of a transceiver for the Remote wall switch
with Z-WAVE. The verification procedure of the receiver portion of this
transceiver is being processed at the same time.

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
3
1.3 Test Methodology
Both AC mains line-conducted and Radiated emission measurement were
performed according to the procedures in ANSI C63.4 (2009). Radiated
emission measurement was performed in semi-anechoic chamber and
conducted emission measurement was performed in shield room. For radiated
emission measurement, preliminary scans were performed in the semi-
anechoic chamber only to determine the worst case modes. All radiated tests
were performed at an antenna to EUT distance of 3 meters, unless stated
otherwise in the "Justification Section" of this Application.
1.4 Test Facility
The Semi-Anechoic chamber and shielding room used to collect the radiated
data and conducted data are Intertek Testing Services Shenzhen Ltd.
Kejiyuan Branch and located at 6F, Block D, Huahan Building, Langshan
Road, Nanshan District, Shenzhen, P. R. China. This test facility and site
measurement data have been fully placed on file with the FCC (Registration
Number: 242492).

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
4
EXHIBIT 2
SYSTEM TEST CONFIGURATION

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
5
2.0 System Test Configuration
2.1 Justification
The system was configured for testing in a typical fashion (as a customer would
normally use it), and in the confines as outlined in ANSI C63.4 (2009).
The EUT was powered by AC 120V/60Hz during the testing.
The models DB038 and DA065 have been tested for radiated emission and
AC conducted emission, only the worst case is shown on this report.
For maximizing emissions, the EUT was rotated through 360°, the antenna
height was varied from 1 meter to 4 meters above the ground plane, and the
antenna polarization was changed. This step by step procedure for
maximizing emissions led to the data reported in Exhibit 3.0.
The rear of unit shall be flushed with the rear of the table.
The equipment under test (EUT) was configured for testing in a typical fashion
(as a customer would normally use it). The EUT was placed on a turn table,
which enabled the engineer to maximize emissions through its placement in the
three orthogonal axes.
2.2 EUT Exercising Software
The EUT exercise program (provided by client) used during radiated and
conducted testing was designed to exercise the various system components in a
manner similar to a typical use.
The parameters of test software setting:
During the test, power controlling software provided by the applicant was used
to control the operating channel.
2.3 Special Accessories
No special accessories used.
2.4 Equipment Modification
Any modifications installed previous to testing by Airline Mechanical Co., Ltd
will be incorporated in each production model sold / leased in the United
States.
No modifications were installed by Intertek Testing Services Shenzhen Ltd.
Kejiyuan Branch.

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
6
2.5 Measurement Uncertainty
When determining the test conclusion, the Measurement Uncertainty of test has
been considered.
2.6 Support Equipment List and Description
Description Manufacturer Model No.
Lighting Load Airline Mechanical Co., Ltd
1800W, 120Vac/60Hz, 15A
External Switch Airline Mechanical Co., Ltd
N/A

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
7
EXHIBIT 3
EMISSION RESULTS

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
8
3.0 Emission Results
Data is included worst-case configuration (the configuration which resulted in the
highest emission levels). A sample calculation, configuration photographs and
data tables of the emissions are included.

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
9
3.1 Radiated Test Results
A sample calculation, configuration photographs and data tables of the
emissions are included.
3.1.1 Field Strength Calculation
The field strength is calculated by adding the reading on the Spectrum Analyzer
to the factors associated with preamplifiers (if any), antennas, cables.
A sample calculation is included below.
FS = RA + AF + CF - AG
Where FS = Field Strength in dBµV/m
RA = Receiver Amplitude (including preamplifier) in dBµV
CF = Cable Attenuation Factor in dB
AF = Antenna Factor in dB
AG = Amplifier Gain in dB
In the radiated emission table which follows, the reading shown on the data
table may reflect the preamplifier gain. An example of the calculations, where
the reading does not reflect the preamplifier gain, follows:
FS = RA + AF + CF - AG
Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4
dB and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is
subtracted. The pulse desensitization factor of the spectrum analyzer was 0
dB, and the resultant average factor was -10 dB. The net field strength for
comparison to the appropriate emission limit is 32 dBµV/m. This value in dBµV/m
was converted to its corresponding level in µV/m.
RA = 62.0 dBµV
AF = 7.4 dB
CF = 1.6 dB
AG = 29.0 dB
FS = 62 + 7.4 + 1.6 - 29 = 42 dBµV/m
Level in µV/m = Common Antilogarithm [(42 dBµV/m)/20] = 125.9 µV/m

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
10
3.1.2 Radiated Emission Configuration Photograph
For electronic filing, the worst case radiated emission configuration photograph
is saved with filename: radiated photos. pdf.
3.1.3 Radiated Emissions
The data on the following page lists the significant emission frequencies, the
limit and the margin of compliance. Numbers with a minus sign are below the
limit.
Worst Case Radiated Emission
at
96.074 MHz
Judgement: Passed by 5.3 dB
TEST PERSONNEL:
Sign on file
Andy Yan, Engineer
Typed/Printed Name
July 14, 2012
Date

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
11
Company: Airline Mechanical Co., Ltd Date of Test: July 14, 2012
Model: DB038
Sample: 1/1
Worst Case Operating Mode: Transmit
Table 1
Radiated Emissions
Polarization Frequency Reading Pre- Antenna Net Limit Margin
(MHz) (dBµV) Amp Factor at 3m at 3m (dB)
Gain (dB) (dBµV/m) (dBµV/m)
(dB)
Horizontal 114.684 44.4 20.0 7.4 31.8 43.5 -11.7
Horizontal 168.119 43.9 20.0 10.0 33.9 43.5 -9.6
Horizontal 396.302 38.0 20.0 16.5 34.5 46.0 -11.5
Vertical 36.016 37.2 20.0 14.4 31.6 40.0 -8.4
Vertical 96.074 50.0 20.0 8.2 38.2 43.5 -5.3
Vertical 444.322 35.7 20.0 17.7 33.4 46.0 -12.6
NOTES: 1. Quasi-Peak detector is used except for others stated.
2. All measurements were made at 3 meters. Harmonic emissions not
detected at the 3-meter distances were measured at 0.3-meter and an
inverse proportional extrapolation was performed to compare the signal
level to the 3-meter limit. No other harmonic emissions than those
reported were detected at a test distance of 0.3-meter.
3. Negative value in the margin column shows emission below limit.
4. All emissions are below the QP limit.

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
12
3.1.4 Transmitter Spurious Emissions (Radiated)
The data on the following page lists the significant emission frequencies, the
limit and the margin of compliance. Numbers with a minus sign are below the
limit.
Worst Case Radiated Emission
at
1816.840 MHz
Judgement: Passed by 7.9 dB
TEST PERSONNEL:
Sign on file
Andy Yan, Engineer
Typed/Printed Name
July 14, 2012
Date

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
13
Applicant: Airline Mechanical Co., Ltd Date of Test: July 14, 2012
Model: DB038
Sample: 1/1
Worst Case Operating Mode: Transmit
Table 2
Radiated Emissions
(908.420MHz)
Polarization Frequency Reading Pre- Antenna Net QP Limit Margin
(MHz) (dBµV) Amp Factor at 3m at 3m (dB)
Gain (dB) (dBµV/m) (dBµV/m)
(dB)
Horizontal 908.420 60.9 0.0 24.8 85.7 94.0 -8.3
Polarization Frequency Reading Pre- Antenna Net AverageLimit Margin
(MHz) (dBµV) Amp Factor at3m at 3m (dB)
Gain (dB) (dBµV/m) (dBµV/m)
(dB)
Horizontal 1816.840 55.7 36.8 27.2 46.1 54.0 -7.9
Horizontal 2725.260 49.3 36.7 29.6 42.2 54.0 -11.8
Horizontal 3633.680 49.8 36.5 31.8 45.1 54.0 -8.9
Notes: 1.Quasi-Peak detector is used for frequency up to 1GHz and Peak detector is
used for frequency over 1GHz.
2. All measurements were made at 3 meter. Harmonic emissions not detected
at the 3-meter distance were measured at 0.3-meter and an inverse
proportional extrapolation was performed to compare the signal level to the
3-meter limit. No other harmonic emissions than those reported were
detected at a test distance of 0.3-meter.
3. Negative value in the margin column shows emission below limit.
4. Horn antenna is used for the emission over 1GHz.
Test Engineer: Andy Yan

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
14
3.2 Conducted Emission at Mains Terminal
3.2.1 Conducted Emissions Configuration Photograph
For electronic filing, the worst case conducted emission configuration
photograph is saved with filename: conducted photos.pdf.
3.2.2 Conducted Emissions
Worst Case Neutral-Conducted Configuration
at
24.018 MHz
Judgement: Passed by 4.7 dB margin
TEST PERSONNEL:
Sign on file
Andy Yan, Engineer
Typed/Printed Name
July 14, 2012
Date

INTERTEK TESTING SERVICES
Report No: SZ12060359-1
FCC ID: ZGIDA065
TRF No.: FCC 15C_TX_b
15
Applicant: Airline Mechanical Co., Ltd Date of Test: July 14, 2012
Model: DB038
Sample: 1/1
Worst Case Operating Mode: Transmit With Full Load
Conducted Emission Test - FCC
0
10
20
30
40
50
60
70
80
150k 300 400500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Level in dBµ
Frequency in Hz
FCC Part 15 Class B Voltage on Mains QP
FCC Part 15 Class B Voltage on Mains AV
Result Table-QP
Frequency
(MHz) QuasiPeak
(dBμV) Line
Corr.
(dB)
Margin
(dB) Limit
(dBμV)
0.202000
43.8
L1 9.6
19.7
63.5
0.338000
41.2
L1 9.6
18.1
59.3
1.178000
29.8
L1 9.7
26.2
56.0
1.846000
26.8
L1 9.7
29.2
56.0
12.010000
38.6
L1 10.1
21.4
60.0
24.018000
41.6
L1 10.6
18.4
60.0
Result Table-AV
Frequency
(MHz) Average
(dBμV) Line
Corr.
(dB)
Margin
(dB) Limit
(dBμV)
0.202000
37.6
L1 9.6
15.9
53.5
0.338000
24.1
L1 9.6
25.2
49.3
1.178000
24.2
L1 9.7
21.8
46.0
1.846000
19.6
L1 9.7
26.4
46.0
12.010000
34.3
L1 10.1
15.7
50.0
24.018000
41.3
L1 10.6
8.7
50.0