AirMan W03A-54 User manual

OWNER’S MANUAL
MODEL NO: W03A-54
KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE OPERATING THIS UNIT,
READ THE MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE.
INFLATION
STATION
Everyday
CORDLESS
[ACT 050] Manual E 3/30/06 9:43 AM Page 3

1
HIGH-PRESSURE
APPLICATIONS
•Car tires
•Bicycle tires
•Basketball
•Sporting equipment
•Party balloons
HIGH-VOLUME
APPLICATIONS
•Air mattresses
•Rafts
•Inflatable toys
•Pool toys
INFLATION
STATION
Everyday
CORDLESS
[ACT 050] Manual E 3/30/06 9:43 AM Page 4

www.activeproducts.com 2
1
2
3A
4
5
678
910 11
12 13
14 15A 16
Accessories include:
PARTS LIST
ITEM NO. QTY DESCRIPTION PARTS NO.
1 1 High-volume air inflator ATI-W03A-201
2 1 High-pressure air compressor ATI-W03A-101
3A 1 Charger station ATI-W03A-304
4 2 Wall-mount/desktop bracket ATI-W03A-302
5 1 Adapter holder ATI-W03A-303
6 1 Large adapter ATI-W03A-421
7 1 Medium adapter ATI-W03A-423
8 1 Inflatable connector ATI-W03A-424
9 1 Ball adapter ATI-W03A-411
ITEM NO. QTY DESCRIPTION PARTS NO.
10 1 Small adapter ATI-W03A-422
11 1 Balloon adapter ATI-W03A-412
12 1 12V cigarette lighter ATI-W03A-401
adapter pack
13 1 Pressure gauge hose ATI-W03A-402
14 2 Ni-Cd rechargeable battery ATI-W03A-501
15A 1 AC charger ATI-W03A-404
16 2 Hardware kit ATI-W03A-601
[ACT 050] Manual E 3/30/06 9:43 AM Page 5

INSTALLATION PROCEDURE
THE INFLATION STATION COMES WITH TWO BRACKETS TO BE USED FOR EITHER
WALL-MOUNTING OR DESKTOP POSITIONING. A HARDWARE KIT IS PROVIDED
FOR WALL-MOUNTING INSTALLATION. EXTRA HARDWARE MAY BE REQUIRED TO
SECURE THE STATION ONTO SOME WALLS. MAKE SURE THE STATION IS FIRMLY
SECURED ONTO THE WALL BEFORE PLACING THE COMPONENTS ON THE STATION.
1
Important: Remove all components from
the charger station prior to the installation.
Install two brackets onto the bottom two
holes on the back of the charger station,
as shown.
2
Seat the charger station on a flat surface.
Connect the AC charger and return all com-
ponents back onto the charger station.
DESKTOP PLACEMENT
3
[ACT 050] Manual E 3/30/06 9:43 AM Page 6

www.activeproducts.com
WALL-MOUNT INSTRUCTIONS
1
Important: Remove all components from
the charger station prior to the installation.
Install two brackets into the top two holes
on the back of the charger station.
2
Install the charger station onto drywall
using the hardware kit provided. Extra
hardware may be required to secure the
station onto some walls. For concrete
walls, purchase appropriate concrete
fasteners.
Mount the charger station onto the wall,
making sure it is securely mounted.
3
Connect the AC charger and place all com-
ponents back onto the charger station.
4
[ACT 050] Manual E 3/30/06 9:43 AM Page 7

POWER SOURCE
Both the air compressor and air inflator can
be powered by both the Ni-Cd rechargeable
battery and the 12V cigarette lighter adapter.
RECHARGEABLE BATTERIES
The Inflation Station comes with two 9.6V
1,000 mAh Ni-Cd rechargeable batteries. The
two batteries are identical and can be used on
both the air compressor and air inflator. The
batteries can be charged either on the charger
station, or from the AC charger port on
the battery.
CHARGING BATTERY
ON THE CHARGER STATION
Before initial use, place both high-pressure air
compressor and high-volume air inflator on the
charger station for an initial charge time of 15 to
18 hours. Repeat charging times are approxi-
mately 8-12 hours, if batteries are depleted.
Warning! Failure to fully charge the battery will
result in shorter life, compromised perform-
ance and will void battery warranty. To keep
both air compressor and air inflator fully
charged at all times, place both units on the
charger station whenever they are not in use.
The charger station red LED indicator will be
“ON” once the air compressor and/or air infla-
tor has been properly placed on the station.The
charger station will control battery charging to
ensure optimal battery charge. We recommend
that if the inflation station is not going to be
used for an extended period of time (i.e. 4
months or more), the unit should be unplugged
and stored indoors. When the inflation station
is removed from storage, please re-charge for
15 to 18 hours before use.
CHARGING FROM THE AC CHARGER
PORT ON THE BATTERY
Remove the battery from the air compres-
sor/inflator by gripping the end of the battery
and pulling it out.The same AC charger can be
used to charge the battery directly by con-
necting the AC charger to AC charger port on
the battery and plugging the AC charger to an
110V-120V power source. The red LED indica-
tor will be “ON” when the battery is charging.
When charging directly from the AC charger
port on the battery, the charging time must
not exceed 24 hours. Repeat charging times
are approximately 10 -15 hours, if the battery
is depleted.
Power Source
Indicator
AC Charger Port
Red LED Indicator
Red LED Indicator
AC Charger Port
STEP 1
STEP 2
5
[ACT 050] Manual E 3/30/06 9:43 AM Page 8

www.activeproducts.com
TYPICAL RUN-TIME*
DEVICE TYPICAL RUN-TIME*
Air Compressor 10-15 minutes
Air Inflator 15-20 minutes
* REMARK:
1. Typical run-time will vary depending on
the battery level, pressure load during use,
and the operating conditions.
2. High-pressure loading, or excessive back
pressure will result in a shorter run-time
than indicated above.
3. Cold temperature conditions will reduce
battery run-time. We recommend
using the 12V cigarette lighter adapter
pack during cold temperature
operating conditions.
When the operating period per charge is
significantly reduced, it indicates the
battery is worn-out and should be replaced.
To order a replacement battery,
please call 1-866-9AIRMAN,
or visit www.activeproducts.com
12V CIGARETTE LIGHTER ADAPTER PACK
Switching between the battery and 12V ciga-
rette lighter adapter pack
•Roll out the 12V cord before use.
•Remove the battery from the
air compressor/inflator by gripping the
end of the battery and pulling it out.
•Slide the 12V adapter pack into the
air compressor/inflator until clicks into
place. Make sure that the cord runs
through the small hole at the base of
the cable pack.
•Connect the 12V car cigarette lighter
adapter to the cigarette lighter socket in
your car.
6
[ACT 050] Manual E 3/30/06 9:43 AM Page 9

ON/OFF
trigger button
Union valve
Air nozzle
Lock switch
(counterclockwise)
Loosen
(clockwise)
Tighten
Balloon adapter
Ball adapter
Pressure gauge hose
A
B
BA
INFLATION INSTRUCTION
HIGH-PRESSURE AIR COMPRESSOR
The Air Compressor has been specially
designed for simple and fast inflation of car
tires, bicycle tires, basketball, sporting equip-
ment, and party balloons.The air compressor
provides a small quantity of air at a relatively
high pressure.
INFLATING A CAR TIRE AND BICYCLE TIRE
1. Loosen the union valve from the air nozzle.
2. Insert the pressure gauge hose into
the air nozzle and tighten the union valve.
3. Screw the thread connector onto tire’s
valve stem.
4. Unlock the trigger lock switch and press
the trigger button. For continuous infla-
tion, engage the trigger lock switch.
5. Operate the air compressor until the
desired pressure is reached.
6. Remove the thread connector from the tire.
Note: To avoid over-inflation of tires, please
check the recommended car tire pressure in
the vehicle’s owner’s manual. For bicycle tire,
please check the tire marking.
INFLATING SPORTING EQUIPMENT
(I.E. BASKETBALL) OR PARTY BALLOONS
1. Loosen the union valve from the air nozzle.
2. Insert the ball/balloon adapter into the air
nozzle and tighten the union valve.
3. Insert the ball/balloon adapter into valve of
the object to be inflated.
4. Operate the air compressor until the object
is fully inflated.
5. Remove ball/balloon adapter from the
inflated object’s valve.
Note: If a pressure reading is required during
inflation, use the pressure gauge hose provided.
CAUTION
•Do not run the air compressor continuously for more than 15 minutes.
After each 15 minutes, allow it to cool for a minimum of 15 minutes.
•Do not leave the air compressor unattended while in operation.
Keep out of reach of children.
•Do not exceed maximum pressure of 150 psi.
•The built-in pressure gauge will provide an estimated reading only.
Please use a digital pressure gauge for more accuracy pressure information.
7
[ACT 050] Manual E 3/30/06 9:43 AM Page 10

www.activeproducts.com
ON/OFF
trigger button
Inflation outlet
Deflation outlet
Lock switch
Large adapter
Medium adapter
Small adapter
Inflatable
connector
HIGH-VOLUME AIR INFLATOR
The Air Inflator is designed for quick and easy
inflation and deflation of high air volume
objects such as air mattresses, rafts, inflatable
toys and pool toys.
BEFORE INFLATING
Choose the appropriate inflatable adapter.
There are four inflatable adapters provided
for high-volume inflation/deflation.The small
and medium adapters must be used with the
inflatable connector provided.The inflatable
connector and large adapter can be directly
attached to the inflation air outlet.
INFLATING PROCEDURE
1. Insert the appropriate inflatable adapter
into inflation outlet.
2. Insert adapter into the air valve of the
object to be inflated.
3. Unlock the trigger lock switch and press
the trigger button. For continuous
inflation, engage the trigger lock switch.
4. Operate the air inflator until the desired
firmness is reached.
5. Remove adapter from the inflated object
valve and close the valve cap.
DEFLATING PROCEDURE
1. Insert the inflatable adapter into
deflation outlet.
2. Insert adapter into the valve of the object
to be deflated.
3. Unlock the trigger lock switch and press
the trigger button. For continuous defla-
tion, engage the trigger lock switch.
4. Operate the air inflator until desired
deflation is reached.
5. Remove adapter from the deflated
object valve.
Note: Make sure the stop valve or resisted
valve is opened, before inflation or deflation.
INFLATION TIPS FOR LARGE OBJECTS:
The performance of an air inflator depends on
air flow rate, size of adapter and the valve of the
inflatable object. The smaller the valve and/
or adapter used, the lower the air flow rate.
Therefore, always buy inflatable objects with
the largest possible valves.Typically, air mat-
tresses or large inflatable objects may have
two sizes of air valve, always inflate from the
largest valve to get maximum performance.
CAUTION
•Do not run the air inflator for continuously for more than 15 minutes. After each
15 minutes, allow it to cool for a minimum of 15 minutes.
•Do not leave the air inflator unattended while in operation. Keep out of reach of children.
•Make sure the stop valve or resisted valve is opened, before inflation or deflation.
8
[ACT 050] Manual E 3/30/06 9:43 AM Page 11

GENERAL SAFETY MEASURES AND
PRECAUTIONS THAT APPLY TO THE
USE OF AIR COMPRESSOR/INFLATOR.
The following instructions apply to both the
air compressor and air inflator.
Safe operation of the air compressor and
inflator require that you read the instructions
and safety precautions carefully and follow
all instructions before using the air compres-
sor or inflator.
1. The air compressor and inflator are
designed for occasional use. Inflation
over a long period will overheat the
air compressor or air inflator and may
cause damage.
2. The air compressor and inflator must not
operate for more than 15 minutes
at a time, after which it must be switched
off and set aside to cool for at least
15 minutes before restarting.
3. If the air compressor or inflator emits
abnormal sounds or overheats,
turn it off immediately and let it cool
off for minimum 30 minutes.
4. Inspect air compressor, inflator and
batteries before use. If cracked, broken
or damaged parts are found, qualified
technicians should repair damaged parts.
5. Incorrect use of air compressor/inflator
may result in personal injury and/or
property damage.
6. Never expose the air compressor, inflator
or battery to rain, frost or temperatures
above 50 ºC (122 ºF). Never charge the
battery in humid or wet locations.
7. Never use the air compressor or inflator
near flammable fluids or gases. Make
sure your working area is well-lit.
8. Protect yourself against electric shock.
Avoid physical contact with grounded
surfaces such as pipes, radiators, electric
stoves, refrigerators, etc.
9. Never allow children to connect/disconnect
the air compressor or inflator to/from
power sources. Never leave children
unattended with the air compressor or
inflator and never allow them to play with
the accessories.
10. Never allow anyone to pump air into
mouth, ears, nose, etc of people,
or animals.The air compressor/inflator
is not a toy.
11. Store air compressor and inflator
in a secure location. If the air
compressor/inflator for long periods
of time, it should be stored in a
dry space inaccessible to children.
12. Regularly check the charger cord.
Never carry the charger by the cord and
never pull the plug out of the outlet
by jerking the cord. Make sure the cord
is not exposed to hot objects, oil or
sharp edges.
13. Keep the air compressor and inflator
clean to maintain maximum output and
safety. Examine the plug, charger and
cable pack at regular intervals and have
them repaired by qualified technicians if
they are damaged.
14. Unplug the 12V car cigarette lighter
adapter from the cigarette lighter socket
in your car when is not in use.
15. Unplug the AC charger from the battery
when the charger is not in use.
16. Never charge the battery outdoors.
Do not open the battery. Protect it against
impact.The battery should be stored in a
dry, frost-free place.
17. The battery and charger are designed
for each other. Only an AirMan charger
should be used.
18. Protect the battery against heat and fire
to prevent danger due to explosion!
19. Do not place the battery on a heater and
do not expose it to solar radiation for a
prolonged period. Exposing battery to
temperatures above 50 ºC (122 ºF) will
damage the battery. Allow batteries to
cool off completely before charging.
20. Do not directly connect the positive (+)
and the negative (-) terminals.
This will result in a short-circuit caused
by metallic arcing.
21. Stay alert. Always pay attention to what
you are doing when working with the air
compressor, inflator, charger and battery.
22. Warning! For your own safety, you
should only use accessories and
parts specified in the instructions,
or recommended for use by the
manufacturer. Use of accessories
and other parts that are not mentioned
in the instructions may entail
an increased risk for the user of
the air compressor and inflator.
9
[ACT 050] Manual E 3/30/06 9:43 AM Page 12

www.activeproducts.com
BATTERIES AND THE ENVIRONMENT
The accompanying batteries can be recharged
at least 500 times, when it is time to replace the
batteries, please consider the environment.
The EPA certified RBRC®Battery Recycling
Seal on the nickel-cadmium (Ni-Cd) battery
indicates that Active Products is voluntarily
participating in an industry program to collect
and recycle these batteries at the end of their
useful life, when taken out of service in the
United States or Canada.The RBRC®program
provides a convenient alternative to placing
used Ni-Cd batteries into trash or the munici-
pal waste stream. Please call 1-800-822-8837
for information on Ni-Cd battery recycling and
disposal bans/restrictions in your area. Active
Products’ involvement in this program is part
of our commitment to preserving our environ-
ment and conserving our natural resources.
WARRANTY
This Active Products equipment carries a two-
year limited warranty against defects in manu-
facturing workmanship, and a one-year limited
warranty on the batteries and accessories.
This Limited Warranty shall be limited to the
repair or replacement of parts which prove
defective under normal use and service and
which on examination shall indicate, to Active
Product’s satisfaction, they are defective. Active
Products reserves the right to request the
return of defective parts. Shipping charges may
apply. Before returning any parts, contact the
toll-free hotline 1-866-9AIRMAN (924-7626). If
Active Products confirms the defect and
approves the claim,Active Products will elect to
replace such parts without charge.
The foregoing warranty does not apply to
defects resulting from faulty installation, oper-
ation, disassembly, alterations or remodeling,
or misuse, misapplication, neglect, abuse, acci-
dent, tornado, hurricane, and earthquake; or
lack of proper maintenance, cleaning and care.
Warranty will not apply if this product is used
for commercial or rental purposes. This war-
ranty shall not extend to anyone other than
the original purchaser of this product.
Should this product become defective within
the stated warranty period, do not return to
store, but call 1-866-9AIRMAN (924-7626).
Have the sales receipt handy.
The warranty card is not a replacement for the
proof of purchase. Please keep your proof of
purchase in a secure place.
10
[ACT 050] Manual E 3/30/06 9:43 AM Page 13

Imported by:
Active Products Inc.
Toronto, Ontario, Canada M3B 2M3
Toll free:
1-866-9AIRMAN (1-866-924-7626)
www.activeproducts.com
Made in China
0306
[ACT 050] Manual E 3/30/06 9:43 AM Page 2
Table of contents
Popular Docking Station manuals by other brands

CableJive
CableJive dockBoss Air quick start

Listen Technologies
Listen Technologies ListenTALK LA480 quick start guide

Mockett
Mockett PCS98D quick start guide

Loewe
Loewe Audiodesign SoundBox ID operating instructions

Altec Lansing
Altec Lansing inMotion iM11 manual

StarTech.com
StarTech.com 101N-USBC-DOCK quick start guide