manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Airmax
  6. •
  7. Air Compressor
  8. •
  9. Airmax ProAir 4 User manual

Airmax ProAir 4 User manual

Other Airmax Air Compressor manuals

Airmax LR25 Maintenance and service guide

Airmax

Airmax LR25 Maintenance and service guide

Airmax SilentAir RP25 (87R) User manual

Airmax

Airmax SilentAir RP25 (87R) User manual

Airmax SilentAir G33 User manual

Airmax

Airmax SilentAir G33 User manual

Airmax T100 User manual

Airmax

Airmax T100 User manual

Airmax SilentAir LR50 User manual

Airmax

Airmax SilentAir LR50 User manual

Airmax Pond Logic SilentAir SW Series Maintenance and service guide

Airmax

Airmax Pond Logic SilentAir SW Series Maintenance and service guide

Airmax Crystal Clear PondAir 2 User manual

Airmax

Airmax Crystal Clear PondAir 2 User manual

Airmax AMC062-1 User manual

Airmax

Airmax AMC062-1 User manual

Airmax SilentAir G25 User manual

Airmax

Airmax SilentAir G25 User manual

Airmax SilentAir G75 User manual

Airmax

Airmax SilentAir G75 User manual

Airmax SW20 User manual

Airmax

Airmax SW20 User manual

Popular Air Compressor manuals by other brands

Craftsman 919.724591 owner's manual

Craftsman

Craftsman 919.724591 owner's manual

Atlas Copco GA 30+ Instruction book

Atlas Copco

Atlas Copco GA 30+ Instruction book

Hitachi Highly WHP11500VSDPC9EQ installation manual

Hitachi

Hitachi Highly WHP11500VSDPC9EQ installation manual

Craftsman 919.167810 owner's manual

Craftsman

Craftsman 919.167810 owner's manual

Yamato 24/2 M1CD instruction manual

Yamato

Yamato 24/2 M1CD instruction manual

Clarke 2242117 Operation & maintenance instructions

Clarke

Clarke 2242117 Operation & maintenance instructions

Sparmax DC-25XR user manual

Sparmax

Sparmax DC-25XR user manual

Briggs & Stratton Air Compressor Operator's manual

Briggs & Stratton

Briggs & Stratton Air Compressor Operator's manual

Fini F3GST2TK Operator's manual

Fini

Fini F3GST2TK Operator's manual

Campbell Hausfeld RP3300 Easy setup guide

Campbell Hausfeld

Campbell Hausfeld RP3300 Easy setup guide

Ingersoll-Rand UP6 20 HP Option manual

Ingersoll-Rand

Ingersoll-Rand UP6 20 HP Option manual

Parkside PKO 270 A1 operating instructions

Parkside

Parkside PKO 270 A1 operating instructions

Clas Ohlson QIE-ZTH-15 manual

Clas Ohlson

Clas Ohlson QIE-ZTH-15 manual

Ferm CRM1046 Original instructions

Ferm

Ferm CRM1046 Original instructions

BE AC153 Operation manual

BE

BE AC153 Operation manual

RIDGID OF25150A Operator's manual

RIDGID

RIDGID OF25150A Operator's manual

Johnson Controls QUANTUM LX Setup

Johnson Controls

Johnson Controls QUANTUM LX Setup

Ring Automotive RAC700 instructions

Ring Automotive

Ring Automotive RAC700 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

airmaxeco.com | 866-424-7629 | P.O.Box 38 | Romeo, MI 48065
ProAir™ 4 Diuser
For All PondSeries™ and LakeSeries™
Aeration Systems
Item # 510166
4
INSTALLATION INSTRUCTIONS
Product Contents .........................2
Installation ..............................3
Maintenance .............................4
Troubleshooting ..........................4
Replacement Parts........................4
Warranty ................................4
Table of Contents:
MAINTENANCE
Every 12 months, we recommend purging the membrane sticks. To do this, force all
air to one ProAir™ 4 diuser for 10 seconds by closing all valves on the compressor
manifold except one. Repeat for all ProAir™ 4 diusers. For aeration systems
containing only one diuser, pull the pressure relief valve on the compressor and
let go. Repeat this process 6 to 8 times.
TROUBLESHOOTING
If you have loss of airow to one or more diusers:
• Check to ensure airow valves on compressor manifolds
are adjusted correctly.
If large boiling bubbles are present on the water’s surface:
• Check membrane sticks for tears.
• Check for loose connections on diuser manifold.
REPLACEMENT PARTS
REPLACEMENT PARTS ITEM #
Diuser Manifold w/Check Valve #490374
Diuser Sled #490337
PTFE 6”Membrane Stick #510168
Marine Stainless Hose Clamp #490158
½”to ¾”Insert Reducer Adapter #490118
3⁄8”to ¾”Insert Reducer Adapter #490118
Check Valve #490340
WARRANTY
All PondAir™ 4 diusers carry a 5-year warranty extended exclusively to the
original purchaser. This warranty begins from the date of original purchase
receipt. Any component which proves to be defective in material or workmanship
as determine by Airmax®, Inc. will be repaired or replaced at no charge. The
end user shall assume all responsibility and expense for removal, packaging
and freight to ship to Airmax®, Inc. to determine the warranty claim and for all
reinstallation expenses.
Improper installation, careless handling, misuse, abuse or failure to follow
maintenance or operating instructions as well as any modication or repair by
an unauthorized repair facility will void all warranty. Diuser membranes are
considered wear parts and are not covered under warranty.
airmaxeco.com | 866-424-7629 P.O.Box 38 | Romeo, MI 48065
2 3
The ProAir™ 4 is the most advanced diuser on the market today and is specically
designed to maximize circulation and oxygen transfer in ponds and lakes. The
ProAir™ 4’s weighted sled design keeps the diuser submerged and prevents it
from sinking into the muck. The exclusive PTFE non-stick membrane sticks provide
the synergy of air stones while being virtually maintenance-free. Each diuser also
includes a check valve to prevent back pressure to the compressor.
PRODUCT CONTENTS INSTALLATION INSTRUCTIONS
Step 2
Hand tighten two Membrane Sticks
onto Diuser Sled.
NOTE: Do not remove black rubber
o-rings from membrane sticks.
Step 3
Align second Diuser Sled with
Diuser Manifold.
Step 4
Hand tighten two more Membrane
Sticks onto the second Diuser Sled.
Step 5
Depending on the size of airline, screw
corresponding reducer adaptor into
the check valve. Slide hose clamp
onto the airline and connect airline
to the reducer adaptor. Firmly tighten
stainless hose clamp onto airline to
secure into place.
Step 1
Align Diuser Manifold with one
Diuser Sled ensuring the Airmax®
logo on the Diuser Manifold is
facing up.
C
E F
A
B
D
A2 – Diuser Sleds
B4 – PTFE 6” Membrane Sticks
C1 – Diuser Manifold w/Check Valve
D1 – ½” to ¾” Insert Reducer Adapter
E1 – 3/8” to ¾” Insert Reducer Adapter
F1 – Marine Stainless Hose Clamp