LOOP MODEL DESIGN (Fig.1)
LOOP series extraction fan includes body
1with mounted motor and propeller.
Control plate is mounted in the central
ow section (protected by cover 3,
mounted with screws 4). Part 5is xed to
the front part of the body and serves to
insert the power supply cable. Power
supply cable is protected by the cover 2.
The device and the inlet are protected by
masking front 6.
Preparations for fan mounting should
start with taking o the masking front 6
(snap-in mounted)and cover 2. Next,
power supply cable opening should be
made in part 5. Last preparation step
before mounting the fan is driving screws
4to make it possible to take cover 3o
and access control plate with power
terminals.
Warning !!! LOOP WL100R, WL125R model has a movement detection sensor attached with a tape to cover 3-
remain cautious not to damage the connecting tape (it is recommended to take the cover o after mounting
the fan in the ventilation duct).
MOUNTING INSTRUCTIONS
• place the prepared fan body in a
ventilation duct - mark mounting
openings
• make openings for anchors and
space them equally to the openings
on the fan body
• place the fan in the ventilation duct,
inserting the power cable through
the opening made in the body
beforehand
X
Y
ZW
D
C
A
B
Ø
LOOP Ø100 Ø125
Operating Range I II I II
Capacity [m³/h] 55 85 120 165
Power [W] 3,3 4,6 7 10
Power supply [V] 230
Rated Frequency [Hz] 50
Protection Rating IPX4
Fig. 1
2
6
1
3
4
5
INDEX Ø X Y A B C D Z W
LOOP WL100
100 160 160 125 125 109 109 76 102
LOOP WL125
125 200 200 153 153 137 137 77 102