alcatraz Rock User manual

The Rock
Install Guide

Mount 2-gang switch box in wall
Alternate corridor install for tight spaces
Installation to be performed only by certified installer
Power Sourcing Requirement: PoE+ (802.3at Type 2) 30W
Unit to be powered by UL294B certified IEEE PoE+ 802.3at Type 2 Power
Sourcing Equipment using unshielded cat5e or better cable with a maximum
cable length of 330 feet (100 meters)
A ULC 60839-11-1 Listed power supply with appropriate grade is required to
be provided for ULC installations
Panel maximum cable length: 500 ft - 22 AWG (152 m), 300 ft - 24 AWG (91 m),
Badge Reader maximum cable length: 3.2 ft - 22 AWG (1 m)
Complies with US FDA performance standards for laser products except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007
CAUTION: Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure
ATTENTION: L’utilisation de commandes, réglages ouinstructionsautres que ceux
spécifiés ci-dessus présenteunrisque d’exposition dangereuse aux radiations
Step 1 –Installation Prerequisite
Parts Included
1x Alcatraz Rock
1x Wall Mount
1x Wiring Harness
1x Wall release tool
4x Cable Ties
4x Mounting Screws #6-32
Required tools and supplies
2-Gang switch box
Gel filled B connectors or equivalent
22/6 cable, 5-9 conductor, Genesis 12061109 or equivalent (Wiegand)
Level
Measuring tape
Wire stripper / cutter
Phillips screwdriver
Install on door opening side
5ft (1.5m) from floor
5ft (1.5m) from floor
½” (13mm) minimum
Screw tabs must be in
vertical position
Badge reader
mounted at
standard height
Lenses towards users
using door, ignore
door arrow marking
on wall plate
Position close to corner:
leave minimum of 3” (76mm) of space for
cooling and for tool to remove Rock
For best performance,
place within 6” (150mm) of door
Leave minimum of ½” (13mm)
between 2-gang switch box
and door frame
2-gang
switch box

Wire cable harness to badge reader and access control panel
Step 2 –
Connection Overview Wiring table
Minumum wires required for Wiegand in RED
Minimum Required Connections
CAUTION: Incorrect wiring may cause permanent damage
ATTENTION: Un mauvais câblage peut causer des dommages irréversibles
Wire the badge reader and Access Control system as required for your installation
For wiegand installations that require 1-Wire LED control, connect the ORANGE wire
(Panel LED Green) to the LED terminal on the panel
Alcatraz
Rock
Unshielded
Cat5e/Cat6
Badge
Reader
Access
Control
Panel
PoE+ Ethernet
Wiegand Cable
NOTE: LED line is required to be hooked up to ACS
Badge Reader Panel
Panel +12v RED
Panel GND BLACK
Panel D0 / RS485A GREEN
Panel D1 / RS485B WHITE
Panel Beeper YELLOW
Panel Tamper VIOLET
Panel Hold BLUE
Panel LED Green*ORANGE
Panel LED Red BROWN
Badge Reader +12v RED
Badge Reader GND BLACK
Badge Reader D0 / RS485A GREEN
Badge Reader D1 / RS485B WHITE
Badge Reader Beeper YELLOW
Badge Reader Tamper VIOLET
Badge Reader Hold BLUE
Badge ReaderLED Green*ORANGE
Badge Reader LED Red BROWN
Wiegand
READER
PANEL
Badge
Reader
Access
Control
Panel
+12v
GND
D0
D1
LED Green
+12v
GND
D0
D1
LED Green
RED
BLACK
GREEN
WHITE
ORANGE
RED
BLACK
GREEN
WHITE
ORANGE
~1m / 3ft

Plug in and retain cables
Step 4 –
Included cable ties
Cable ties secured
and trimmed
Cable tie
attachment point
Pre-loop cable
ties to post
Thread cables through and attach
wall plate to 2-gang box
Step 3 –
Attach wall plate to 2-gang box with provided flat head screws, paying
attention to point the arrow towards door
Installed screw heads must be flush to the wall plate. Protruding screw
heads will cause interference when installing the Rock onto the wall plate
Use edge of tunnel to level wall plate
Arrow towards door
PoE+ Ethernet
Wiring harness
Unit to be powered by
IEEE PoE+ 802.3at Type2
UL294 Certified Power
Sourcing Equipment.
PoE+ input power:
42-57 VDC 0.5A
Complies with ULC 60839-11-1, Grade 2,
Environmental Indoor. Refer to Installation Guide
part #541-0001-00-00 for Wiring Diagram and details.
For standard
install, point
arrow towards
door.
For corridor
install, point
arrow away
from door.
Alcatraz AI, Inc.
Rock-1 Alcatraz Facial Identification
Access Control Device
RED
BLACK
GREEN
WHITE
YELLOW
VIOLET
BLUE
ORANGE
BROWN
Badge & Panel Wires
+12 VDC
GND
D0 / RS485A
D1 /RS485B
Beeper
Tamper
Hold
LED Green
LED Red
OPTIONAL
REQUIRED
ntal In
0001-

Attach Alcatraz Rock to wall plate
Step 5 –
To remove Rock from wall plate, press spring pin hidden behind the vent mesh
Press and snap Rock onto installed wall plate
The Rock has TAMPER detection: Removal of Rock from wall plate
will result in TAMPER signal assertion to ACS
To complete the Installation and onboarding please refer to the
User Guide (see QR code on back cover)
CAUTION:
Do not press
on glass lens
cover during
installation,
glass may
break
ATTENTION:
Lors de
l’installation,
ne pas appuyer
sur le couvercle
en verre de la
lentille pour ne
pas le briser
Spring Pin
Release Opening
Spring Pin Release Tool
(3mm metal shaft)
Post installation check
Step 6 –
One or more of the following status icons may be present in the status bar on
the display after bootup
Display Zones & LED ring colors
Rock Power up
The Rock must have PoE+ (802.3at Type 2, minimum 30W) plugged into a
reliable source to provide the Rock with sufficient power
The bootup sequence will not be successful if the Rock does not have
sufficient power.
Booting
A circular progress bar appears in the main
display to indicate booting and will complete in
approximately 2 min
Running
By default all new Rocks start in demo mode
until configured. This will be indicated by the
word DEMO down the left side of the display
QR Code read active
Server connection bad
Not on-boarded to server
Person in range
*PoE Power Fault
No network connection
*Panel Power Fault
*Tamper detected
WHITE Idle / Standby
BLUE Badge ID sent
GREEN Access Granted
Info Bar
Status Bar
Main
Display
* Must be resolved before completing install

ROCK-1 ALCATRAZ FACIAL AUTHENTICATION
ACCESS CONTROL DEVICE
Part Number S10-0001
Input Power PoE+ (42.5 to 57V DC) Rock Power Consumption 10W Typical at 25C
Badge Reader Output 12VDC 200mA
Operating Temp -20º – 66ºC (-4º – 150ºF), UL Tested: 0º – 49ºC
Humidity Relative humidity 10-90% non condensing
Weight 709g (1lb 9oz)
Size W 13.2cm (5.2”) x H 12.2cm (4.8”) x D 8.3cm (3.3”)
FCC
CE Marking
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
CAUTION: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to
operate this equipment.
ATTENTION: Tout changement ou toute modification apportés à cet appareil sans l’approbation expresse du fabricant risque
d’invalider l’autorisation relative à son utilisation.
Equipment not intended for connection to telephone, or outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70
Ethernet/PoE+ and Wiegand Cable to Reader and Panel are Class II/Power Limited
Max number of face/templates enrolled shall not exceed 10,000
Alcatraz AI hereby declares that these facial authentication devices are in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.
WARNING: This product can expose you to chemicals including DINP, which is known to the State of California
to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive
harm. For more information go to www.P65Warnings.ca.gov.
AVERTISSEMENT: Ce produit peut vous exposer aux produits chimiques, dont DINP, connu de l’Etat de
Californie pour causer le cancer et DIDP, connu de l’Etat de Californie pour causer des anomalies congéniales ou
d’autres dommages reproductifs. Pour plus d’informations, visitez le site www.P65Warnings.ca.gov.
©2020 Alcatraz AI, Inc., All rights reserved
Support:
1 (650) 600-0197
support.alcatraz.ai
Alcatraz AI, Inc.
1808 El Camino Real
Redwood City, California 94063
541-0001-00-00 www.alcatraz.ai Scan for User Guide
Other manuals for Rock
2
This manual suits for next models
1
Table of contents