SOYAL
ACCESS CONTROL SYSTEM
®AR-321-H /AR-721-H/ AR-331-H
AR-725-H / AR-757-H V221226
- 13 -
Command List
Function
Card or PIN(M6)
Set up the mutual PIN in Card or PIN mode
Card and PIN(M6)
Set up the mutual PIN in Card and PIN mode
Setting duress PWD(M4/M8)
Setting arming PWD(M4/M8)
Node ID setting (Connected to 716E)(M4/M8)
Node ID setting (Connected to the PC directly
without 716E) (M4/M8)
Door Relay Time setting
Alarm Relay Time setting
Arming Delay Time setting
Alarm Delay Time setting
Arming Pulse Time setting
Door Close Time
Controller time clock setting
Same tag reading interval time
Command
15 ????
17 ????
15 ????
17 ????
00 NNN
00 NNN VVV nnn
02 TTT
03 TTT
05 TTT
06 TTT
14 TTT
18 TTT
25 YYMMDDHHmmss
31 TTTT
Description
????=4-digit PIN(0001~9999 ; default value=4321)
????=4-digit PIN(0001~9999 ; default value=1234)
0000= Set as card only
????=4-digit PIN(0001~9999 ; default value=4321)
※The Duress Code 0000 means that disable
Duress Function and the default value is set as
0000 already.
????=4-digit PIN(0001~9999 ; default value=1234)
NNN=Node ID of Access Controller (range:
001~016)
NNN=Node ID of Access Controller
(range: 001~254)
VVV=Virtual 716E Node ID, nnn=Door number
(range:001~254)
TTT=Door relay time 000= Output continuously
001~600=1~600 sec.
601~609=0.1~0.9 sec.
TTT=Alarm relay time 000= Output continuously
001~600=1~600 sec.
TTT=the buer time before entering arming mode
001~600=1~600 sec.
TTT=the buer time before the alarm is activated
001~600=1~600 sec.
TTT=Arming output time; 000=output continuously
001~250=0.1~2.5 sec.
TTT=Door Close Time: 001~600=1~600 sec.;
default value: 15 sec.
YYMMDDHHmmss=Year/ Month/ Day/ Hour/ Min./
Sec.
TTTT=10~6000 (Base on 10ms, range from 10 to
6000; default value: 1 sec.
:
0100)
Access Mode
Setting
Arming /Duress
Function
Setting
(M4/M8 applicable
, but not M6)
Node ID
Setting
Time /Delay
Setting
Please refer to Compound Command Function List
for details.
N= 0 (1st time zone) / 1 (2nd time zone)
HHMM= Starting time; hhmm= ending time
(i.e.: 08301600=08:30 to 16:00)
7123456H= 7 days of week (Sun/Mon/Tue/Wed/
Thu/Fri/Sat)+ Holiday(H= 0: disable; 1: enable);
Holidays can be set by 701Client software.
SSSSS=Starting User Address;
EEEEE=Ending User Address;
N=0: Enable; N=1: Disable; N=2: Reset
After enabling keypad lock function, press any
button will only has two beeps and no reaction.
Disable the keypad lock function will bring controller
keypad function back to normal. (only Keypad
Controllers have this function ex. AR-721-H; Touch
Keypad Controllers do not have this function ex.
AR-725-H)
UUUUU=User Address, S=4 sets of lift control (0~3);
FFFFFFFF=8 assigned oor(F=0: Disable, 1: Enable)
NNN=site number,
TTT= relay time: 000~600=1~600 sec.
UUUUU=User Address; FF=Floor (01~32 oor)
20 ???
24 ???
28 ???
08 N HHMMhhmm 7123456H
26 SSSSS EEEEE N
(simultaneously)
24 002
21 UUUUU S FFFFFFFF
23 NNN TTT
27 UUUUU FF
Controller
Additional
Function
Setting
Lift
Control
Setting
Exit
Program
Mode
Reader additional setting
Controller parameter setting
Double Door Control / Force Open Alarm
Auto-open time zone setting
Anti-pass-back (Enable user)
Enable/Disable keypad lock
Controller parameter setting
Lift control setting: multi-oor(M4/M8)
AR-401RO16 Lift Relay Activated TM
(M4/M8)
Lift control setting: single oor
(M4/M8)
Exit program mode
Exit program mode and enter arming
mode(M4/M8)
※More Details:Introduction of New Function Commands for Enterprise E Controller and Home H Controller