Alean AL-238P User manual

AL-238
PPROGRAMMING GUIDE
AL-238P
Installation Manual

AL-238
PPROGRAMMING GUIDE
2
Contents
Part 1 General description ................................................................................................................................................................... 3
1. AL-238P main function ............................................................................................................................................................ 3
2.System wiring instructions ....................................................................................................................................................... 5
3. Main board LED lights status description ............................................................................................................................... 8
4.Main parts description .............................................................................................................................................................. 9
Part 2 System Operation Instruction .................................................................................................................................................. 11
1.User operation guide.............................................................................................................................................................. 11
2.System programming instruction ........................................................................................................................................... 12
3. Control panel programming list and each item default value ................................................................................................ 12
Attachment 1 ............................................................................................................................................................................. 12
Attachment 2 ............................................................................................................................................................................. 13
4. Programming example .......................................................................................................................................................... 23
Part 3.Zone type and password permission description .................................................................................................................... 25
1. Zone type and description .................................................................................................................................................... 25
2. System password permission description ............................................................................................................................. 26
Part 4. Expansion module function application .................................................................................................................................. 26
1. The 4G module uploads the network alarm center, only 1 center can be uploaded ............................................................. 26
2. The IP module is uploaded to the network alarm center, and the IP can be uploaded to 2 centers at the same time ......... 26
3. The user telephone alarm notice .......................................................................................................................................... 27
Address code list ....................................................................................................................................................................... 29

AL-238
PPROGRAMMING GUIDE
3
Part 1 General description
This series of control panel is a kind of intelligent voice-based security technology prevention product that integrates many
advanced technologies and functions. It is widely used in various types of security systems such as villa community, perimeter
alarm system and office building.
The alarm system consists of a control keypad, a control panel, a remote control, an infrared detector, a door magnet, a smoke
detector, and a strong siren. Easy to install, simple to operate, can store 8 alarm calls (such as: user mobile phone number, fixed
phone number, etc.). It can be used alone (not connected to the Internet), or can be used for networking through GPRS/IP. It can
realize computer software management, cloud service alarm system connection, and easy integration with other systems. It is an
ideal choice for installing anti-theft alarm equipment in homes, business places, financial systems and other units.
1. AL-238P main function
1.1、 Features
Up to 40 zones can be connected: with 8 wired zones, up to 40 wired zones can be extended through the 485 expansion
module; up to 40 433MHz or LORA wireless zones can be extended.
The control panel itself supports 2 programmable outputs and one alarm output.
Each programmable output supports 200mA current, supports arming linkage, alarm linkage, software control.
The panel supports a siren interface, which can be set with active or passive output.
DC13.8V power input; 1 group of auxiliary power output (max 1500mA); 1 group of backup battery interface.
Extend 40 relay outputs through 485, which can be used as linkage output, and the
linked zones and attributes can be programmed.
Support 6 groups of timed arming and disarming functions, support Monday to
Sunday optional. Arm and disarm the entire control panel.
The control panel can communicate through phone, SMS, GPRS, IP and other alarm
notifications, support 8 SMS and telephone alarm numbers;
1 GPRS center, 2 IP centers; support alarm calls and SMS notifications. Telephone and text messages can remote arming/
disarming. Each group of SMS numbers can be set to disarm. You can call, program, and listen to the intercom on the phone.
Support 8 LED keypads, LED keypad can display the status of zone, programming, armed and disarmed.
The control panel supports 1 installer password and 1 programming password, 1 hijack password, 16 user passwords
(programmable disarming authority), and 40 zone operation passwords.
Support RS232 interface, support local program upgrade and access 232 serial
printer, real-time alarm printing.
Support 10 seconds recording, record the name of the installation location of the alarm control panel, broadcast the recording
when the alarm, let the alarm personnel know the alarm position at the first time.

AL-238
PPROGRAMMING GUIDE
4
Intelligent voice prompts, support for arming and disarming, programming, alarm voice broadcast, and zone broadcast
content synchronization zone name (use "local control panel name" + "zone name" + "alarm" combination). Voices include
local broadcasts and user phone voice broadcasts. Support remote reminders, off duty reminders and warning reminders for
networked alarm users.
The system comes with a real-time clock, and continues to run under power failure.
The system supports the black box function, which can save the latest 6000 alarm records and operation records separately.
Voice broadcast alarm record and time.
The voice broadcast is queried through the keypad operation: alarm record, operation record, system status, system time,
system version, and GPRS signal strength.
Modular design, the circuit board contains LORA module interface, IP module interface, GPRS module interface, PSTN
module interface. Users can choose.
Support 16 groups remote control, remote control one-button self-learning.
Support multiple arming and disarming methods such as outgoing arming, forced arming, staying arming, and quick arming.
1.2.Electrical performance index
Input power DC12-24V
Backup battery 12V7AH lead acid battery
Auxiliary output DC12V 1500mA
Static current 300mA
Alarm current ≥1000mA
Siren interface Active,DC12V 2000mA;or passive NO output
PGM output DC12V 200mA
Wired zone 2.2KΩ EOL Resistor
Wireless parameters 433MHz,encoding mode 1527,oscillation
resistance220KΩ
Operating temperature -10~55℃
Chassis size 255*265*88mm
Keypad size 161*120*28mm
Weight ≥3kg

AL-238
PPROGRAMMING GUIDE
5
2.System wiring instructions
2.1.System wiring diagram
2.2.AL-238P connection to the power supply
AL-238P adopts wide voltage design, can withstand DC12-24V power supply (factory standard DC13.8V 3A power supply); it will
prompt the system under voltage,when the power supply voltage is lower than 10V;
2.3.AL-238P and the keypad connection
The VCC, A, B, and GND of the keypad correspond to the red, green, yellow, and black
terminals of the master keypad, and up to 8 keypads are connected.
Alarm Control Panel System Wiring Diagram
Siren in terfa ce
Auxiliary output
Power input
PGM1
COM Z ONE 1
Siren interface
active output:
Siren interface
passive output:
plug-in AB and CD of JP2
plug-in BC of JP2
Battery
12V 7AH
RS232 port
Record button
MC1 microphone
Program upgrade
jumper
Password restore
jumper
4G module
Network module
433 wireless
IP network
Battery
PGM2
COM Z ONE 2
COM Z ONE 3
COM Z ONE 4
COM Z ONE 5
COM Z ONE 6
COM Z ONE 7
COM Z ONE 8
Keypad interface
power+
-power
DC power supply-1
Warning sign
Siren
Zone 1
Zone 2
NO PIR detector
NC PIR detector
power+
-power
DC power supply-2
Red
Grn
Yel
Blk
Master keypad
Red GrnYel Blk Central software
Note: Please use wires to plug-in the zone
terminals t hat do not need to be
connected to the detect or.
LoRa module

AL-238
PPROGRAMMING GUIDE
6
2.4.AL-238P connection to wired detector
The AL-238P series control panel can connect up to 8 wired detectors, and supports 4 kinds of zone wiring methods.
The specific connection method is as follows:
1、NC wired detector
connection
2、NO wired detector
connection
3、With 2.2K NO wired
detector connection
4、With 2.2K NC wired
detector
connection
Remarks: Description of the default wiring method between the AL-238P panel zone port and the wired detector
The portof the zone (zone 1 to zone 8) is connected to the "NC signal" of the detector by default;
Please use a wire to plug-in the zone terminals that do not need to be connected to the detector, or close it through keypad
programming. For programming, please refer to the "command 05" in the programming table of the manual;
2.2K
EOL resistor
2.2K
EOL resistor

AL-238
PPROGRAMMING GUIDE
7
2.5.AL-238P connection to siren
AL-238P siren interface description
Siren interface active output: plug-in AB and CD of JP2
Siren interface passive output: plug-in BC of JP2
As shown in FIG:
Plugged-in AB and CD of JP2 jumper of AL-238P panel, the siren interface is active output, and the output power
consumption is DC12V 2000mA;
Plugged-in BC of JP2 jumper of AL-238P panel, the siren interface is passive output;
2.6.AL-238P connection to bus device (8 zones extend module, linkage relay, slave keypad)
The AL-238P control panel is connected to the bus device (8 zones extend module, linkage relay module) through the RS485
keypad communication interface. The power supply of the bus device and its detector is recommended to be powered by a
separate power supply. The total power consumption of all devices attached to the same power supply should not exceed the
power rating of the power supply
Alarm Control Panel System Wiring Diagram
Siren in terfa ce
Auxiliary output
Power input
PGM1
COM Z ONE 1
Siren interface
active output:
Siren interface
passive output:
plug-in AB and CD of JP2
plug-in BC of JP2
Battery
12V 7AH
RS232 port
Record button
MC1 microphone
Program upgrade
jumper
Password restore
jumper
4G module
Network module
433 wireless
IP network
Battery
PGM2
COM Z ONE 2
COM Z ONE 3
COM Z ONE 4
COM Z ONE 5
COM Z ONE 6
COM Z ONE 7
COM Z ONE 8
Keypad interface
power+
-power
DC power supply-1
Warning sign
Siren
Zone 1
Zone 2
NO PIR detector
NC PIR detector
power+
-power
DC power supply-2
Red
Grn
Yel
Blk
Master keypad
Red GrnYel Blk Central software
Note: Please use wires to plug-in the zone
terminals t hat do not need to be
connected to the detect or.
LoRa module

AL-238
PPROGRAMMING GUIDE
8
8 zones expansion module address dial code description: the address dial code range is 0-4; the address dial 0, the zone
number represents 1-8 zone, dial 1 represents 9-16 zone, and so on;
Linkage module address dial code description: the address dial code range is 64-66; the address dial 64, the relay linkage
output point is 1-16, dial 65 represents 17-32 channels, and so on;
Keypad address description: the address range is 0-7; the address is 0, it represents the main keypad, 1 represents the slave
keypad, and so on;
2.7.Backup battery
Backup battery 12V/7AH, the red line of the control panel battery interface is connected to the battery + and the black wire is
connected to the battery -. When the power supply fails, the control panel automatically switches to the backup power
supply.
3. Main board LED lights status description
LED Light LED function LED status
LED1 Power light Light on when in power
LED2 Serial communication light Light on when serial port receives the data
LED3 485 communication light Light on when 485 communication is normal and
flashing, light off when abnormal
LED4 System running light Light flashes once every 1 second when system
runs
normally
LED5 GPRS communication light Light flashes once every time GPRS receives data
LED6 IP module communication
light
Light flashes once every time IP receives data
LED7 LORA communication light Light flashes once every time LORA receives data
GrnYel Blk
Keypad interface
DC power supply-2
8 zones expansion
module(address 0-4)
Partition keypad
(address 1-7)
16-output module
(address 64-66)
Red Grn yel B lk

AL-238
PPROGRAMMING GUIDE
9
4.Main parts description
4.1.Keypad
Keypad layout:
The keypad is mainly divided into two areas: the display area and the keypad
area.
The keypad display area shows the running status of the control panel: such
as arm, alarm, communication , power supply, program, bypass, and zone.
The keypad area is mainly divided into: password input and programming
command input, system arming, disarming, staying arming, bypass and other
function buttons.。
Keypad display status description:
Power light Light on when in power
Arming light Light on when system armed, off when system disarmed
Bypass light Light on when staying armed
Program light Light on when in programming
Communication light Light on as long as one center and software communication is normal
Alarm light Light on when any zone alarm
1-24 zone light The zone lights are off when zones are normal; the zone light will be on the zone is
triggered; the zone light will be on for a long time when zone alarms and the zone light will
flash after the alarm time expires.
4.2.Module function
4G module Network module
4G module is the panel GPRS、GSM mobile network
expansion module; the status of the module LED is as
follows:
LED1=Module power-on status
Constantly light on means the module is turned on; light off:
not initialized or turned off;
LED2=SIM status light;
Constantly light on means the SIM card
is detected, light off means the SIM card is not detected.
LED3=receiver indicator:
When the module serial port receives data, the light is on;
The module is a network extension module of alarm panel,
which can realize TCP/IP communication and achieve the
network alarm function.

AL-238
PPROGRAMMING GUIDE
10
when there is no data, the light is off;
LED4=Send indicator:
When the module serial port sends data, the light is on; when
there is no data, the light is off;
LED5=Network indicator:
Long flashing once every 3s: successful registration of the
network; flashing once every 800ms: network off; light off: no
network registered
LED6=Module power light:
Light on: module power supply; light off: module no power
supply
8 zones module LORA module
8 zones module address dial code range 0-4; the address
dial 0, the zone number represents 1-8 zone, dial 1
represents 9-16 zone, and so on.
LoRa module: The LoRa module is the LoRa communication
extension module of the alarm panel, which supports the
access of LoRa wireless alarm device.

AL-238
PPROGRAMMING GUIDE
11
Part 2 System Operation Instruction
1.User operation guide
1.1 .Arming
Keypad arming: password(123456) + “ARM ” key
Remote controller arming: Press“ ”key
After right operation, control panel sounds di…di…di…, wait till control panel delay arming time is up(10s), and the arming
succeeds.
1.2.Disarming
Keypad disarming: password(123456)+"disarming " key
Press remote control disarming:“ ”key
Keypad buzzer sounds once, the alarm enters disarming status.
1.3.Quick arming
Keypad quick arming: "ARM" key for 3sec or more, control panel buzzer sounds
di…di…di…, wait until control panel delay arming time is up, and succeeds. (Buzzer +
voice hint till delay arming ends).
Note: this function requires turn on “Quick arming”, for programming, please refer to "Command 13" in the programming table of
the user manual
1.4.Stay arming
Keypads stay arming: password(123456) + "stay” key
Press remote control stay arming: “ ”key, control panel starts sound di…di…di…,
wait till delay time is up, control panel arming succeeds. (Buzzer + voice hint till delay
arming ends).
Staying arming mode, when there is a zone set to the home zone, adapting Stay Arming, all of home zones are invalid, which
means they are in disarming status, only effective when are not home zone.
1.5.Single zone arming and disarming(For 1-8 zone)
123456+”bypass” key,when enter the single zone arm and disarm programming state, press the “zone number” + “arm or disarm
“key, you can arm or disarm the corresponding zone, press * to exit the programming state;
1.6.Duress disarming:
Keypad operation: seized & held password +"disarming " key, control panel disarms and report to receiver to tell Duress alarm.
1.7.Enter / exit programming instructions
Enter programming——password(123456)+#;
Exit programming—— “*”key ;
1.8.Eliminate alarm
Keypad operation: password(123456)+"*" key (can remove voice, linkage, siren, display)
1.9.Query alarm record
Enter the password ( 123456)) +#, enter the programming, and then enter 00+01, the panel broadcasts the latest alarm record,
press the “1” key to query the previous alarm record, press the “2 “key to query the next alarm record, and press the “0 “key to
repeat to broadcast once, press “*# “to exit the query.
If you need to query information such as "Operation Record", "System Version", "System Time" and "GSM Antenna Signal Value",
please refer to "Command 00" in the programming table of the user manual;

AL-238
PPROGRAMMING GUIDE
12
1.10.Keypad lock and unlock
If keypad locked function is turned on, keypad disarming operates 3 times error password, and enters locked status. Only beep
when you press any key. The keypad will unlock automatically after15 minutes or cut off the control panel and restart.
1.11.Recovery keypad programming password is123456
<1>. Disconnect the keypad power.
<2>. Plug-in the keypad J1jumper.
<3>. Turn on the keypad power.
<4>. Plug-out the keypad J1jumper.
1.12.Modify keypad address
(1). Press and hold the [bypass] key on the keypad for more than 3 seconds; enter the keypad programming password: 6 digits,
the factory default password is 123456
(2). Press and hold the [*] key for 3 seconds. The programming light is always on to show that you have entered the programming
mode;
(3). Enter function code 0100 (function code is 4 digits);
(4). Enter a 2-digit keypad address such as 01 (keypad address is from 0 to 7, a total of 8 keypad addresses). If input correct, the
panel will make a long beep; if input wrong, it will issue a "di di di" 3 Sound error prompt, the keypad will automatically exit the
programming mode when the input is wrong, you must press the above operation again to enter the programming and enter the
correct programming value to succeed;
(5). During or after programming, just press and hold the "*" key for 3 seconds to exit the programming mode;
1.13.Recover the panel master password
Power off the panel, short-circuit the jumper J11 on the main board of the panel, and then power on the master password to
restore the default value; after the power off to reset the jumper J11 ;
1.14.Panel restore factory settings
Power off the panel, short-circuit the jumper J11 of the panel motherboard, and then power on, enter the password (123456) +#,
enter the programming, and then enter 44+02+1# to initialize immediately, and the panel will restore the factory settings and
restore after power off to reset jumper J11 ;
2.System programming instruction
Enter programming——input format: master password (6 digits) + # (factory default master password: 123456)
Note: Note: enter programming successfully, buzzer sounds a long beep, programming LED turns on voice broadcasts “enter
programming” which means the control panel is in state of programming.
Exit programming——Input format: under programming press “*”directly to exit programming.
Note: when exiting programming state, buzzer sounds a long beep, programming LED
turns off, or stop operating keypad in 30 seconds,control panel will exits automatically, buzzer does not sound,programming
LED turns off
3. Control panel programming list and each item default value
Attachment 1
Control panel query list:
Function
menu
Main
code
Sub-
code
Factory value/
programming
digits
Function
instruction
Allowed programming function
code range and operation
instruction

AL-238
PPROGRAMMING GUIDE
13
Query 00 01 Query alarm record Input format:00+N(01~06);
N means programming address
01~06,that is: various record
numbers;
Press 1 to previous, press 2 to next
query, press 0 to repeat.*#to exit.
E.g. query alarm record, after
entering programming, input 0001.
When querying, voice broadcasts
certain event:E.g., mmddyy hhmm
zone 5 alarms, mmddyy hhmm
arming.
02 Query operation record
03 Query system AC supply,
expand module and
accidents details
04
Query system version
05
Query system time
06 Query GPRS signal
strength
Voice broadcasts
Attachment 2
Control panel programming function list and each address default value:
Function
menu
Main
code
Sub-
code
Factory value/
programming
digits
Function
instruction
Allowed programming
function code range and
operation instruction
Password
setting
01 01 123456(6 digits) Master password
(administrator
password)
Input format:
01+N+new
user password (6digits)+#;
N indicates programming
Address01~59, that is: main
password, programming
password, user password
1~16, zone password 1~40.
E.g. to modify master password to:
123456
Under programming state
input 01+01+123456+# ;
02 654321(6 digits) Programming
password
03 100001(6 digits) Group 1 user
password
04 100002(6 digits) Group 2 user
password
… … …
18 100016(6 digits) Group 16 user
password
19 200001(6 digits) Zone 1
password
... …. …
58 200040(6 digits) Zone 40
password
59 987654(6 digits) Duress
password
User
password
permission
setting
02 01 3(1 digit) Group 1password
arming/disarming
permission
Input format:
02+N+X+#;
N indicates programming
Address01~16,that is:user password
1~16;
X indicates 0 :prohibited;1: arming
allowed ;2:arming allowed ;3:
arming/disarming allowed;
E.g. to set password 1 arming disarming
are allowed, under
programming state, input format:
02+01+3+#;
02 3(1 digit) Group 2password
arming/disarming
permission
… … …
16 3(1 digit) Group 16
password
arming/disarming
permission
Arm &
Disarm
timing
setting
03 01 99999999(8
digits)
Arm &Disarm
timing setting
1 time setting
Input Format:03+N+XXXXYYYY+#;
N indicates programming address
01~06,that is:which means 1~6
groups’ time of Arm &disarm timing.
XXXX means arming time,
02 99999999(8
digits)
Arm &Disarm
timing setting
2 time setting
… … …

AL-238
PPROGRAMMING GUIDE
14
06 99999999(8
digits)
Arm&Disarm
timing setting
6 time setting
the first two digits means hour(s),
the last two digits means minute(s);
YYYY means disarming time,the first
two digits means hour(s), the last
two digits means minute(s);
More than 23:59 is invalid Default factory
value is
99999999.
Arm
&Disarm
timing
Permissions
settings
04 01 1(1 digit) Attribute of
Monday
Input Format:04+N+X+#;
N indicates the
programming address01~07,which
means
Monday to Sunday X means 0::
Forbid arming & disarming timing setting
on that day;
X means 1:Allow arming & disarming
timing setting on
that day
Default factory value is 1which means all
are enabled.
… … …
07 1(1 digit) Attribute of
Sunday
Panel on-
board
zones
attribute
settings
05 00 1(1 digit) Attribute of
control panel
with wired
Zones(overall)
Input format:05+N+X+#;
N indicates programming address
00~08,which means:00 means the
overall zone attributes of the panel,
01~08,means 1~8 zones terminal
attributes;
X means 0=forbid;1=NC;2=NO;
3=comes with 2.2Kresistor;
Default factory value is 1,
which means NC and do not need to
connect to 2.2K
resistor.
01 1(1 digit) Attribute of
control panel
with wired
zones terminal
1
02 1(1 digit) Attribute of
control panel
with wired
zones terminal
2
… … …
08 1(1 digit) Attribute of
control panel
with wired
zones terminal
8
Trigger
valid time
settings
of control
Panel with
wired
zones
06 01 30(2 digits) Triggered valid
time of control
panel with
zone 1
Input format:06+N+X+#;
N indicates programming address
01~08,that is:comes with 1~8
zones;
X indicates triggering
time:programming value01~30;
Formula:(01~30)*20ms which
means 20ms~600ms;
Default factory time is:30(means
600ms);
02 30(2 digits) Triggered valid
time of control
panel with
zone 2
…
…
…
08 30(2 digits) Triggered valid
time of control
panel with
zone 8
Settings
of
zones’
attribute
07 01 111(3 digits) Attribute of
zone 1
Input format:07+N+XYZ+#;
N indicates programming address:
01~40,which means:zone 1~40;
02 111(3 digits) Attribute of
zone 2
…
…
…

AL-238
PPROGRAMMING GUIDE
15
40 111(3 digits) Attribute of
zone 40 X indicates the type of zone:0:Shield
zone;1:instantaneous zone;2:
delay zone;3:24-hour zone;4:fire
zone;5:blank;6:temperature
sensing zone
7:ambulance zone;
8:Trigger the arm and disarm zone
(When triggered, the panel arming ,
triggers again the panel disarming )
9:Intelligent arming and disarming the
zone (if the zone is not triggered for a
long time, the panel will automatically
arming, trigger the zone, and the panel
will disarm. Time refers to the smart
zone settings, including time and trigger
times)
Y indicates siren status:
0 : Silent alarm;
1 : sound alarm;
2:Intercom zone (after setting as an
intercom zone, answer the call and enter
the intercom mode directly);
Z means:0: zone at home;1:zone
not at home;
System default value is 111;
For example: The first zone will be set
as 24 hours zone and sound zone, then
we need input: 07+01+3+1+0+#;
Settings of
smart
zones
08 01 00000(5 digits) Parameter setting
of smart zone 1 Input format:08+N+XXYYZ+#;
N indicates programming address:
01~40,means:zone 1~40;
XXYY indicates:XX m YY s Z indicates
times of being triggered -- programming
value is 1~9.
For example:The smart zone of wired
zone 1 is set to last 10 seconds. trigger
3 times as an alarm prompt,
Under programming state enter:
08+01+0010+3+#;
02 00000(5 digits) Parameter setting
of smart zone 2
... .... ...
39 00000(5 digits) Parameter setting
of smart zone 39
40
00000(5 digits) Parameter setting
of smart zone 40
Settings
of wireless
zones
09
00
Eliminate all
wireless zones.
Input Format:09+00+9+# ;that
means eliminate all
wireless zone codes.
01 Zone 1 wireless
self-learning Input Format:
09+N+X+#;
N indicates programming address
01~40,which means:which
means the match code of zones 1-40
X means: X=1,which means to wait for
the wireless detector to trigger, to trigger
twice, each time interval more than 2
seconds, the prompt "wireless self-
learning success" twice indicating
successful learning, and quit the current
self-taught programming.; X=9 Means to
clear the original learned wireless code.
Within 30 seconds, if there is no button,
it will automatically exit the self-learning
mode;
For example: study zone 1
02 Zone 2 wireless
self
-
learning
.....
40
Zone 40
wireless self-
learning

AL-238
PPROGRAMMING GUIDE
16
wireless code, the
operations are as below: input:
09+01+1+#, when" wireless self-learning
entry"
is heard, to trigger wireless detector
twice, each time interval more than 2
seconds, the prompt "wireless self-
learning success" twice indicating
successful learning.If you want to delete
the wireless code of
zone 1, then input:
09+01+9+#
Settings
of
wireless
remote
control
10
00
Eliminate all
wireless remote
controls
Input Format:10+00+9#Eliminate all
encodes of remote controls;
01 wireless remote
control 1
Input Format:10+N+X+#;
N indicates programming address
01~16, which means: remote control
1~16 learning code;
X means: X=1, start learning and wait for
the wireless remote control to be
triggered twice, each time interval more
than 2 seconds, the prompt "wireless
self-learning success" twice indicating
successful learning, and quit the current
self-taught programming.;
X=9 means clear the original learned
wireless code;
Within 30 seconds, if there is no button,
it will automatically exit the self-learning
mode;
For example: To learn the wireless code
of remote control 1, the operation is as
follows:
Input: 10+01+1+#, prompt "wireless self-
learning entry", press the wireless
remote control twice,each time interval
more than 2 seconds, the prompt
"wireless self-learning success" twice
indicating successful learning. To delete
the wireless code of the remote control
1, enter: 10+01+9+#, after the prompt
"Operation is successful";
02 wireless remote
control 2
..... .....
16
wireless remote
control 16
Settings
of LORA
zones
11 00 Eliminate all
LORA zones
Input Format:11+00+9+# ,
eliminate all LORA zones
01
LORA zone 1
wireless
self
-
learning
Input Format:11+N+X+#;
N indicates programming address
01~40,that means:zones 1~40
matching code study.;
X means: X=1 to start learning, wait for
LORA self-study to report, after the code
is successfully, it will automatically exit
the current self-learning programming
;X=9 means clear the original learned
wireless code;
Within 30 seconds, if there is no button,
it will automatically exit the self-learning
mode;
For example: To learn the wireless code
of LoRa zone 1, the operation is as
follows:
Enter 11+01+1+# in the programming
state to prompt "wireless self-learning
entry". At this time, the LoRa detector is
triggered and the prompt "wireless self-
learning successful" means the learning
is successful. If you want to delete the
wireless code of LoRa zone 1, enter
02 LORA zone 2
wireless
self
-
learning
…
…
…
40
LORA zone 40
wireless
self-learning

AL-238
PPROGRAMMING GUIDE
17
11+01+9+#, and it will prompt "Operation
successful";
Time
settings
12 01 010(3 digits)
System alarm
time
Input Format:
12+01+XXX+#
XXX means alarm time is 000-999s,
default factory
value is 010s
02 010(3 digits)
Keypad arming
delay
Input Format:
12+02+XXX+#
XXX means keypad arming time is 000-
999s,default
factory value is 010s.
03 030(3 digits)
Zone 1 enters
alarm delay
Input Format:
12+03+XXX+#
XXX means zones 1 entry delay time is
000-999s,
default factory value is 030s
… … … …
42 030(3 digits)
Zone 40 enters
alarm delay
Input Format:
12+42+XXX+#
XXX means zones 40 entry delay time is
000-999s,
default factory value is 030s.
43 000(3 digits)
Power-on time
restricts alarm
Input Format:
12+43+XXX+#
XXX means that the system power-on
time restricts
alarm time is
000-999 s , default factory value 000s;
44 000(3 digits)
Siren prompt
after arming
is completed
Input Format:
12+44+XXX+#
XXX means time of siren alarm after arm
completed
is 000-999s,default factory value
is000s.
Arm
quickly/
Force
arming/
system low
voltage/
Reminder of
delay
Zones/
keypad
locked/
AC test/
battery test
13
01 1(1 digit) Quick arming
operation allows
Input Format:12+01+X+#
X indicates: 0 means forbid, while 1
means allow.
Default factory value is 1.
Function description: If the function is
turned on, long press the arm button for
3 seconds to start arming;After this
function is turned on, you do not need to
enter a password to arm , but you must
enter the password to disarm , if the
function is turned off, you need to enter
the password to arm or disarm;
02 1(1 digit) Force arming
turn on/off
Input Format:12+02+X+#
X indicates: 0 means forbid, while 1
means allow.
Default factory value is 1.
Function instruction: The
function is turned on, the fault zone
can be armed directly. If the function is
off,
it is not allowed to arm in faulty zone.
03 0(1 digit) System
undervoltage
buzzer prompt
Input Format:12+03+X+#
X indicates: 0 means forbid, 1 means
allow.
Default factory value is 0.

AL-238
PPROGRAMMING GUIDE
18
Function instruction: If this
function is enabled, the master keypad
buzzer will sound every 10 seconds
when the system is under voltage until
the voltage is
restored. If the function is off, it won’t
prompt.
04 0(1 digit)
Reminder when
delay zones’
arming be
triggered
Input Format:12+04+X+#
X indicates: 0 means forbid, while 1
means allow.
Default factory value is 0.
Function instruction:If this
function is turned on, it will prompt when
the defense
zone of delay type is
triggered until the defense zone is
restored. If this
function is turned off, it will not prompt.
05 0(1 digit)
Keypad locked
Input Format:12+05+X+#
X indicates: 0 means forbid, 1 means
allow.
Default factory value is 0.Function
instruction:If this
function is enabled, the keypad will be
locked automatically when the password
is incorrectly
entered for more than 3 times. To unlock
it, the
control panel needs to be powered off or
wait for 15
minutes to unlock
automatically. If this
function is turned off, the keypad will not
be locked.
06 0(1 digit)
Ac power off/
recovery test
Input Format:12+06+X+#
X indicates: 0 means forbid, 1 means
allow.
Default factory value is 0.Function
instruction:If this
function is on, it will be reported to the
center when the system is power off or
restored. If this function is off, do not
report.
07 0(1 digit) Battery voltage
test
0 means forbid, 1 means allow
PGM
settings
14 01 0(1 digit) PGM1 attribute Input Format:14+N+X+#
N indicates programming
address 01, 02, which means
control panel comes with attribute PGM1
and PGM 2.
X indicates: 0: Remote control (not
following the output of control panel
status, remote
control only)
1:Arming linkage,
disarming disconnects
2:Alarm linkage, disarming
disconnects.
3:Alarm linkage(following
the alarm time of control panel),
disarming
disconnects.
4: Arming linkage (pulse output),
02 1(1 digit) PGM2 attribute

AL-238
PPROGRAMMING GUIDE
19
disarming
disconnects.
5:Linking alarm (pulse output),
disarming
disconnects.
6:Alarm linkage (pulse output)
(following the
alarm time of control panel),
disarming disconnects.
Default factory PMG1 is 0,
PMG2 is 1.
Extended d
evice settin
gs
15 01 0 (1 digit) Number of alarm
modules in the sy
stem
Extended device settings (reserved)
02 0 (1 digit) Number of alarm
modules in the sy
stem
Linkage
correspondi
ng zone
settings
16 01 0101(4 digits) The linkage zone
number of the
linkage point 1
Input format: 16+N+XXYY+#;
N represents programming address:
01~40, namely
Linkage setting of linkage output from 1
to 40;
XX means:the low end of the zone
number of the linkage (1~40 zone);
YY means: the high end of the zone
number of the linkage (1~40 zone);
Note: the high end cannot be less than
the low end;
For example: 01-05 alarm should be
linked to the first linkage output, as long
as any one of the 01 to 05 zones
changes or alarms, the light will be on;
Enter in the programming state:
16+01+0105+#;
The system defaults that there is a one-
to-one correspondence between zones
and linkage outputs, that is, the output
point of the alarm No. 1 in zone 1 is
output, and zones 2 to 40 and so on;
02 0202(4 digits) The linkage zone
number of the
linkage point 2
... ... ...
40 4040(4 digits)
The linkage zone
number of the
linkage point 40
Extend
output
attribute
settings
17 01 2(1 digit) Extend output
1 linkage attribute Input Format:17+N+X+#
N indicates programming
extend output 01~40,
Which means the attribute of
linkage point..
X indicates:
0 means forbid
1:Arming linkage,
disarming disconnects.
2:Alarm linkage, disarming
disconnects. 3:Alarm linkage,
(following alarm
time of control panel)Default factory
value is 2.
02 2(1 digit) Extend output
2 linkage attribute
… … …
40 2(1 digit)
Extend output
40 linkage attribute
User calls 18 01 Maximum 16 digits. User 1 alarm
phone number
Input format: 18+N+phone number (up
to 16 digits) +#;
N means programming address: 01~08,
which is the programming of user
numbers 1~8;
The phone number is a valid phone
number with less than 16 digits;
When using the group internal line to
transfer to an external line, add the
outgoing office number plus * (pause)
02 Maximum 16 digits. User2 alarm
phone number
… … …
08 Maximum 16 digits.
User 8 alarm
phone number

AL-238
PPROGRAMMING GUIDE
20
plus the phone number plus # before
entering the phone number;
For example: the group outgoing number
is 0, use the number 1 to dial the user's
phone:
Input in programming state
18+01+0+*+user number+#
Note: "*" means waiting for 1 second.
Each additional "*" means the waiting
time increases by one second. Press "#"
to end and save the programming.
Clear number method: 18+N+# clear
phone number;
Zone
correspondi
ng
phone
number
19 01 0(1 digit) Dial user’s
phone number
after zone 1 alarms
Input format: 19+N+X+#;
N represents the programming address:
01~40, that is, the alarm dialing setting
of the defense zone 1~40;
X means 1~8: designated to dial one of
the user numbers 1~8;
0=Dial all calls;
The factory default is 0;
For example: after zone 1 alarms, assign
user number 8 to dial:
Input in programming state
19+01+8+#;
02 0(1 digit) Dial user’s
phone number
after zone 2 alarms
… … …
40 0(1 digit) Dial user’s
phone number
after zone 40
alarms
Call Center 20 01 Call center 1 num
ber
Attachment: (only telephone line supp
orts CID protocol)
1. Up to 16 digits;
2. In the input of the address phone
number, when an internal line dials an
external line, enter the external line
number first, then enter "*" and wait f
or 1 second. Each additional "*" will i
ncrease the waiting time by one seco
nd, and then enter the phone number
Press "#" to end;
3. The information of automatic dialing
of the alarm center phone includes:
system restart, setting, reset, arming,
disarming, emergency alarm, zone ala
rm, and zone recovery;
02 Call center 2 num
ber
03 Call center 3 num
ber
04
Call center 4 num
ber
Center num
ber attribut
e setting
21 01 0 (1 digit) Center number 1
attribute setting
0=Main center; 1=Backup center; 2=D
edicated line for arming; 3=Dedicated
line for disarming;
02 0 (1 digit) Center number 2
attribute setting
03 0 (1 digit) Center number 3
attribute setting
04 0 (1 digit) Center number 4
attribute setting
Center uplo
ad report c
ontent setti
ngs
22 01 0 (1 digit) Center 1 upload r
eport content setti
ngs
0=All events are transmitted to the ce
nter;
1=Only the alarm information transmis
sion center;
2=Only the arm and disarm informatio
n transmission center;
02 0 (1 digit) Center 2 upload r
eport content setti
ngs
03 0 (1 digit) Center 3 upload r
eport content setti
ngs
Table of contents
Popular Security System manuals by other brands

Echomaster
Echomaster BUA-97C quick start guide

GeoVision
GeoVision UMV859-A user manual

Geemarc
Geemarc Shake me app instructions

AEI Security & Communications
AEI Security & Communications 3400 Installation & operation manual

jablotron
jablotron JA-162A quick start guide

Dakota
Dakota OverView DMOV-7MQ-C2 user guide