EDM Solution 6+6 Wireless-AE User manual

Solution 6+6 Wireless - AE
Installation Manual
ISSUE 1.20


This page has been included for you to cut out and insert into the spine
of the folder
MA660I
S
olution
6+6
Wireless
AE
Installation
Manual
(61-2) 9672 1233
ISSUE 1.20


Solution 6+6 Wireless - AE
Installation Manual
Copyright 1997 by Electronics Design and Manufacturing Pty Limited,
SYDNEY, AUSTRALIA
Document Part Number MA660I
Document ISSUE 1.20
Printed 02 July 2001
This documentation is provided to suit Solution 6+6 Wireless - AE (CC660/LP660)
Firmware Revision 1.00 – 1.02
Hardware Revision A
Alarm Link Form - Software Version 1.00 = CRO1V10
Copyright Notice
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or
by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of
Electronics Design and Manufacturing Pty Limited.
Trademarks
Throughout this document trademark names may have been used. Rather than put a trademark symbol in every occurrence
of a trademark name, we state that we are using the names only in an editorial fashion and to the benefit of the trademark
owner with no intention of infringement of the trademark.
Notice of Liability
While every precaution has been taken in the preparation of this document, neither Electronics Design and Manufacturing
Pty Limited nor any of its official representatives shall have any liability to any person or entity with respect to any
liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this book.
Electronics Design and Manufacturing Pty Limited reserves the right to make changes to features and specifications at any
time without prior notification in the interest of ongoing product development and improvement.


Table Of Contents
Introduction_____________________________________________________________________ 15
Introduction__________________________________________________________________________ 16
Features _____________________________________________________________________________ 17
Quick Start___________________________________________________________________________ 18
Zone Defaults ________________________________________________________________________________ 18
Programming____________________________________________________________________ 19
Programming_________________________________________________________________________ 20
Programming With The Remote Codepad_________________________________________________ 21
Programming With The Hand Held Programmer___________________________________________ 22
Programming With The Programming Key________________________________________________ 23
Programming Option Bits ______________________________________________________________ 23
Installer’s Programming Commands _____________________________________________________ 24
Command 958 - Enable/Disable Zone Status Mode ___________________________________________________ 25
Command 959 - Test Programming Key ___________________________________________________________ 26
Command 960 - Exit Installer's Programming Mode __________________________________________________ 26
Command 961 - Reset Control Panel Back To Factory Default Settings ___________________________________ 27
Command 962 - Copy Control Panel Memory To Programming Key _____________________________________ 27
Command 963 - Copy From Programming Key To Control Panel________________________________________ 28
Command 964 - Erase Programming Key __________________________________________________________ 29
Command 965 - Set Up Domestic Dialling Format ___________________________________________________ 30
Command 966 - Enable/Disable Automatic Stepping Of Locations_______________________________________ 31
Command 999 - Display Software Version Number __________________________________________________ 32
Disable Factory Default ________________________________________________________________________32
Defaulting The Control Panel ____________________________________________________________________ 33
System Indicators and Operations ___________________________________________________ 35
System Indicators and Operations________________________________________________________ 36
CP5 Eight Zone Codepad_______________________________________________________________ 36
Zone Indicators _______________________________________________________________________________ 36
AWAY Indicator______________________________________________________________________________ 36
STAY Indicator_______________________________________________________________________________ 36
MAINS Indicator _____________________________________________________________________________ 37
FAULT Indicator _____________________________________________________________________________ 37
Audible Indicators_____________________________________________________________________________ 37
CP5 Eight Zone LCD Codepad __________________________________________________________ 38
Zone Indicators _______________________________________________________________________________ 38
AWAY Indicator______________________________________________________________________________ 38
STAY Indicator_______________________________________________________________________________ 38
System Disarmed _____________________________________________________________________________ 39
MAINS Indicator _____________________________________________________________________________ 39
Zone Isolating Mode ___________________________________________________________________________ 39
FAULT Indicator _____________________________________________________________________________ 39
Programming Mode ___________________________________________________________________________ 39
Off Indicator/Zone Sealed_______________________________________________________________________40
On Indicator/Zone In Alarm _____________________________________________________________________ 40
Audible Indicators_____________________________________________________________________________ 40
System Operations_____________________________________________________________________ 41
Arming The System In AWAY Mode _____________________________________________________________ 41
Forced Arming _____________________________________________________________________________ 41
Disarming The System From AWAY Mode_________________________________________________________ 41
Arming The System In STAY Mode ______________________________________________________________ 42
Forced Arming _____________________________________________________________________________ 42
Disarming The System From STAY Mode__________________________________________________________ 43

Codepad Duress Alarm_________________________________________________________________________ 44
Codepad Panic Alarm__________________________________________________________________________ 44
Codepad Fire Alarm ___________________________________________________________________________ 44
Codepad Medical Alarm________________________________________________________________________ 44
Isolating Zones ________________________________________________________________________45
Standard Isolating_____________________________________________________________________________ 45
Code To Isolate_______________________________________________________________________________ 46
Fault Analysis Mode____________________________________________________________________47
Fault Descriptions_____________________________________________________________________________ 48
Low Battery _______________________________________________________________________________ 48
Date and Time______________________________________________________________________________ 48
Sensor Watch ______________________________________________________________________________ 48
Horn Speaker Monitor _______________________________________________________________________ 48
Reserved __________________________________________________________________________________ 48
E2Fault ___________________________________________________________________________________ 48
Zone Transmitter Low Battery _________________________________________________________________ 48
Communication Failure ______________________________________________________________________ 49
AC Mains Failure ___________________________________________________________________________ 49
System Functions_________________________________________________________________ 51
System Functions ______________________________________________________________________52
Installer Code Functions ________________________________________________________________52
Fault Analysis Mode_________________________________________________________________________ 53
How To Enter Fault Analysis Mode_____________________________________________________________ 53
Enable/Disable Wireless Zones ________________________________________________________________ 54
Set The Number Of Days Until The First Test Report_______________________________________________ 55
Event Memory Recall Mode___________________________________________________________________ 56
Walk Test Mode ____________________________________________________________________________ 57
Satellite Siren Service Mode___________________________________________________________________ 57
Initiate Modem Call _________________________________________________________________________ 57
How To Initiate A Modem Call ________________________________________________________________ 57
Turning Telephone Monitor Mode On/Off________________________________________________________ 58
Reserved __________________________________________________________________________________ 58
Send Test Report____________________________________________________________________________ 58
Master Code Functions _________________________________________________________________59
Arm Or Disarm Both Areas At The Same Time____________________________________________________ 59
Changing and Deleting User Codes _____________________________________________________________ 60
Changing and Deleting Remote Radio User Codes _________________________________________________ 62
Changing Domestic Phone Numbers ____________________________________________________________ 64
Event Memory Recall Mode___________________________________________________________________ 65
Walk Test Mode ____________________________________________________________________________ 66
Fault Analysis Mode_________________________________________________________________________ 67
Setting The Date and Time____________________________________________________________________ 68
Turn Day Alarm On and Off___________________________________________________________________ 68
Reset Latching Outputs_______________________________________________________________________ 69
Initiate Modem Call _________________________________________________________________________ 69
User Code Functions – Partitioned Systems Only____________________________________________70
Arm Or Disarm Both Areas At The Same Time____________________________________________________ 70
Hold Down Functions___________________________________________________________________71
Arm The System In AWAY Mode______________________________________________________________ 71
Arm The System In STAY Mode_______________________________________________________________ 71
Horn Speaker Test __________________________________________________________________________ 71
Bell Test __________________________________________________________________________________ 71
Strobe Test ________________________________________________________________________________ 72
Turning Day Alarm On and Off ________________________________________________________________ 72
Fault Analysis Mode_________________________________________________________________________ 72
Initiate A Modem Call _______________________________________________________________________ 73
Reset Latching Outputs_______________________________________________________________________ 73
Codepad ID & Beeper Tone Change ____________________________________________________________ 73
Initiate A Test Report ________________________________________________________________________ 73

Remote Operations _______________________________________________________________ 75
Remote Operations ____________________________________________________________________ 76
Remote Radio Transmitter Operation ____________________________________________________ 76
Arming Via Transmitter In AWAY Mode ________________________________________________________ 76
Disarming Via Transmitter From AWAY Mode ___________________________________________________ 76
Arming Via Transmitter In STAY Mode _________________________________________________________ 77
Disarming Via Transmitter From STAY Mode ____________________________________________________ 77
Panic Alarm Via Transmitter __________________________________________________________________ 77
Turning An Output On Via Transmitter __________________________________________________________ 77
Turning An Output Off Via Transmitter__________________________________________________________ 77
Remote Arming Via The Telephone ______________________________________________________ 78
Upload/Download Via Alarm Link Software _______________________________________________ 79
Remote Connect ______________________________________________________________________________ 79
Remote Connect With Customer Control _________________________________________________________ 79
Remote Connect Without Call Back Verification___________________________________________________ 79
Remote Connect With Call Back Verification _____________________________________________________ 80
Dialler Reporting Formats _________________________________________________________ 81
Dialler Reporting Formats ______________________________________________________________ 82
Contact ID Format ____________________________________________________________________________ 82
Point ID Codes _______________________________________________________________________________ 83
Securitel ____________________________________________________________________________________ 84
Domestic Reporting Format _____________________________________________________________________ 85
Domestic Dialling Function ___________________________________________________________________ 85
Acknowledge Domestic Dialling _________________________________________________________________ 85
Programming Domestic Reporting ______________________________________________________________ 86
Disable Domestic Dialling ______________________________________________________________________ 87
Basic Pager Reporting Format ___________________________________________________________________ 88
Base Station Information __________________________________________________________ 89
Base Station Information _______________________________________________________________ 90
Primary Telephone Number _____________________________________________________________________ 91
Secondary Telephone Number ___________________________________________________________________ 91
Call Back Telephone Number____________________________________________________________________ 91
Dialling Format_______________________________________________________________________________ 92
Handshake Tone ______________________________________________________________________________ 92
Transmission Format___________________________________________________________________________ 93
Reserved ____________________________________________________________________________________ 93
Subscriber ID Number _________________________________________________________________________ 93
Ring Count __________________________________________________________________________________ 94
Answering Machine Bypass _____________________________________________________________________ 94
User Codes______________________________________________________________________ 95
Access Codes _________________________________________________________________________ 96
Installer Code ________________________________________________________________________________ 96
User Codes __________________________________________________________________________________ 96
Remote Radio User Codes ______________________________________________________________________ 96
Teaching Radio User Codes ___________________________________________________________________ 96
Default User Codes ____________________________________________________________________________ 97
User Code Priority ____________________________________________________________________________ 98
Arm and Disarm ____________________________________________________________________________ 98
Arm Only _________________________________________________________________________________ 98
Patrolman Code_____________________________________________________________________________ 98
Arm and Disarm + Code To Isolate _____________________________________________________________ 98
Patrolman Code + Code To Isolate______________________________________________________________ 98
Arm and Disarm + Master Code Functions________________________________________________________ 98
Arm and Disarm + Master Code Functions + Code To Isolate_________________________________________ 98
Code Retries _________________________________________________________________________________ 99

Zone Information________________________________________________________________ 101
Zone Information _____________________________________________________________________102
Day Alarm Mask ____________________________________________________________________________ 102
Day Alarm Resetting _______________________________________________________________________ 102
Day Alarm Latching________________________________________________________________________ 102
Day Alarm Operation _________________________________________________________________________ 103
Day Alarm When Partitioned _________________________________________________________________ 103
EOL Resistor Value __________________________________________________________________________ 104
Connections Of Split EOL Resistors Using N/O Contacts_____________________________________________ 105
Zone Programming ___________________________________________________________________106
Zone Operating Information__________________________________________________________________ 106
Zone Reporting Options _____________________________________________________________________ 106
Tamper Zones_______________________________________________________________________________ 107
Zone Defaults _______________________________________________________________________________ 108
Zone Types_________________________________________________________________________________ 108
Instant Zone ______________________________________________________________________________ 108
Handover Zone____________________________________________________________________________ 108
Delay-1 Zone _____________________________________________________________________________ 108
Delay-2 Zone _____________________________________________________________________________ 108
Reserved _________________________________________________________________________________ 108
Reserved _________________________________________________________________________________ 109
Instant Zone + Isolated In STAY Mode _________________________________________________________ 109
Handover Zone + Isolated In STAY Mode_______________________________________________________ 109
Delay-1 Zone + Isolated In STAY Mode ________________________________________________________ 109
Delay-2 + Isolated In STAY Mode_____________________________________________________________ 109
Reserved _________________________________________________________________________________ 109
Keyswitch Zone ___________________________________________________________________________ 109
24 Hour Burglary Zone______________________________________________________________________ 109
24 Hour Fire Zone _________________________________________________________________________ 109
Chime Zone ______________________________________________________________________________ 109
Zone Not Used ____________________________________________________________________________ 109
Zone Options _______________________________________________________________________________ 110
Lockout Siren & Lockout Dialler______________________________________________________________ 110
Silent Alarm ______________________________________________________________________________ 111
Sensor Watch _____________________________________________________________________________ 111
Keyswitch Zone Options ______________________________________________________________________ 112
Latching Arm and Disarm In AWAY Mode _____________________________________________________ 112
Latching Arm In AWAY Mode _______________________________________________________________ 112
Latching Disarm From AWAY Mode Or STAY Mode _____________________________________________ 112
Latching Arm and Disarm In STAY Mode ______________________________________________________ 112
Latching Arm In STAY Mode ________________________________________________________________ 112
Latching Disarm From AWAY Mode Or STAY Mode _____________________________________________ 112
Momentary Arm and Disarm In AWAY Mode ___________________________________________________ 113
Momentary Arm In AWAY Mode _____________________________________________________________ 113
Momentary Disarm From AWAY Mode Or STAY Mode___________________________________________ 113
Momentary Arm and Disarm In STAY Mode ____________________________________________________ 113
Momentary Arm In STAY Mode ______________________________________________________________ 113
Momentary Disarm From AWAY Mode Or STAY Mode___________________________________________ 113
Zone Pulse Count ____________________________________________________________________________ 114
Zone Pulse Count Handover__________________________________________________________________ 114
Zone Pulse Count Time _______________________________________________________________________ 114
Reporting Options _______________________________________________________________ 115
Reporting Options ____________________________________________________________________116
Report Options 1_____________________________________________________________________________ 116
Enable Zone Bypass Reports _________________________________________________________________ 116
Enable Zone Bypass Restore Reports___________________________________________________________ 116
Enable Zone Trouble Reports_________________________________________________________________ 116
Enable Zone Trouble Restore Report ___________________________________________________________ 116
Report Options 2_____________________________________________________________________________ 117
Enable Duress Reports ______________________________________________________________________ 117
Enable Panic, Medical & Fire Reports __________________________________________________________ 117
Enable Access Denied Reports________________________________________________________________ 117

Enable Test Reports ________________________________________________________________________ 117
Report Options 3_____________________________________________________________________________ 118
Enable AC Mains Fail Reports ________________________________________________________________ 118
Enable Low Battery Reports__________________________________________________________________ 118
Enable Sensor Watch Reports_________________________________________________________________ 118
Enable Opening/Closing Reports ______________________________________________________________ 118
Test Reports ________________________________________________________________________________ 119
Programmable Outputs___________________________________________________________ 121
Programmable Outputs _______________________________________________________________ 122
Output Defaults______________________________________________________________________________ 122
Redirecting Outputs To The Codepad Buzzer_______________________________________________________ 123
Output Event Types___________________________________________________________________________ 124
Output Polarity ______________________________________________________________________________ 131
Output Not Used ___________________________________________________________________________ 131
Normally Open, Going Low __________________________________________________________________131
Normally Open, Pulsing Low _________________________________________________________________ 131
Normally Open, One Shot Low________________________________________________________________ 131
Normally Open, One Shot Low With Retrigger ___________________________________________________ 131
Normally Open, One Shot Low With Reset ______________________________________________________ 131
Normally Open, One Shot Low With Alarm______________________________________________________ 132
Normally Open, Latching Low ________________________________________________________________132
Normally Low, Going Open __________________________________________________________________ 132
Normally Low, Pulsing Open _________________________________________________________________ 132
Normally Low, One Shot Open________________________________________________________________ 132
Normally Low, One Shot Open With Retrigger ___________________________________________________ 132
Normally Low, One Shot Open With Reset ______________________________________________________ 132
Normally Low, One Shot Open With Alarm______________________________________________________ 132
Normally Low, Latching Open ________________________________________________________________132
Timing Of Outputs ___________________________________________________________________________ 133
Pulsing Polarities_____________________________________________________________________________ 133
One Shot Polarities ___________________________________________________________________________ 134
System Event Timers _____________________________________________________________ 135
System Event Timers _________________________________________________________________ 136
How To Program Entry/Exit Timers____________________________________________________________ 136
Entry Time _________________________________________________________________________________ 136
Entry Timer 1 _______________________________________________________________________________ 136
Entry Timer 2 _______________________________________________________________________________ 136
Exit Time __________________________________________________________________________________ 137
Entry Guard Timer For STAY Mode _____________________________________________________________ 137
Sensor Watch Time___________________________________________________________________________ 137
Codepad Lockout Time________________________________________________________________________ 138
Siren Run Time______________________________________________________________________________ 138
Siren Sound Rate_____________________________________________________________________________ 138
Swinger Shutdown Count ______________________________________________________________________ 139
System Time ________________________________________________________________________________ 140
Setting The Date and Time ___________________________________________________________________ 140
Options Bits ____________________________________________________________________ 141
Dialler Options ______________________________________________________________________ 142
Dialler Options 1_____________________________________________________________________________ 142
Enable Dialler Reporting Functions ____________________________________________________________ 142
Disable Dialler Reporting Functions____________________________________________________________ 142
Enable Remote Arming Via The Telephone______________________________________________________ 142
Enable Upload/Download Via Alarm Link_______________________________________________________142
Terminate “Alarm Link” Session On Alarm______________________________________________________ 142
Dialler Options 2_____________________________________________________________________________ 143
Send Open/Close Reports Only If A Previous Alarm Has Occurred ___________________________________ 143
Enable First To Open, Last To Close Reporting When Partitioned ____________________________________ 143
Send Open/Close Reports When In STAY Mode__________________________________________________ 143
Delay Siren Until Transmission Complete _______________________________________________________ 143

System Options 1 ____________________________________________________________________________ 144
Enable Forced Arming ______________________________________________________________________ 144
Enable EDM Smart Lockout__________________________________________________________________ 144
Enable Monitoring Of Horn Speaker ___________________________________________________________ 144
Allow Horn Speaker Beeps For Remote Control Operations_________________________________________ 144
System Options 2 ____________________________________________________________________________ 145
Enable Radio Key/Keyswitch Interface or Night Arm Station________________________________________ 145
Enable Handover Delay To Be Sequential _______________________________________________________ 145
Enable Codepad Panic To Be Silent____________________________________________________________ 145
Enable Access Denied To Be Silent ____________________________________________________________ 145
System Options 3 ____________________________________________________________________________ 146
Enable Data Output To Display Data For Area 1 - Partitioned Systems Only ____________________________ 146
Enable Resetting Of Sirens From All Areas (Partitioned Systems Only)________________________________ 146
Ignore AC Mains Fail Indication ______________________________________________________________ 146
Enable Zone Pulse Count Handover____________________________________________________________ 146
System Options 4 ____________________________________________________________________________ 147
Enable AC Fail In 1 Hour____________________________________________________________________ 147
Extend Time To Wait For Handshake From 30 Seconds To 1 Minute__________________________________ 147
Enable Control Panel To Power Up In The Disarmed State__________________________________________ 147
Enable Remote Radio Zone Low Battery Reports _________________________________________________ 147
Consumer Options 1__________________________________________________________________________ 148
Send Test Reports Only If The System Is Armed__________________________________________________ 148
Enable Operation Of Siren & Strobe In STAY Mode ______________________________________________ 148
Enable Answering Machine Bypass Only When Armed ____________________________________________ 148
Enable Codepad Extinguish Mode _____________________________________________________________ 148
Consumer Options 2__________________________________________________________________________ 149
Enable Single Button Arming In AWAY Mode Or STAY Mode _____________________________________ 149
Enable Single Button Disarming From STAY Mode_______________________________________________ 149
Enable Alarm Memory Reset On Disarm________________________________________________________ 149
System Options 5 ____________________________________________________________________________ 149
Enable Internal Crystal To Keep Time__________________________________________________________ 149
Partitioning_____________________________________________________________________ 151
Partitioning__________________________________________________________________________152
Master Partitioned Codepad Indicators____________________________________________________________ 152
Zone Indicators____________________________________________________________________________ 152
Area ON/OFF Indicators ____________________________________________________________________ 152
Area Display Indicators _____________________________________________________________________ 152
Status Indicators ___________________________________________________________________________ 152
Operating Codepads In Partitioning ______________________________________________________________ 153
Operating From A “CP-5 Area Addressable (CP500A)” Codepad ____________________________________ 153
Operating From A “CP-5 Master Partitioned (CP500P)” Codepad ____________________________________ 153
Securitel and Partitioning ______________________________________________________________________ 154
Subscriber ID Number ________________________________________________________________________ 154
Open/Close Reports __________________________________________________________________________ 155
Dialler Options 2 ____________________________________________________________________________ 155
Send Open/Close Reports Only If A Previous Alarm Has Occurred ___________________________________ 155
Enable First To Open, Last To Close Reporting When Partitioned ____________________________________ 155
Send Open/Close Reports When In STAY Mode__________________________________________________ 155
Delay Siren Until Transmission Complete _______________________________________________________ 155
Zone Allocations_____________________________________________________________________________ 156
Zones Allocations For Area 1___________________________________________________________________ 156
Zones Allocations For Area 2___________________________________________________________________ 156
Tamper Zone Allocations______________________________________________________________________ 157
User Code Allocations ________________________________________________________________________ 157
Remote Radio User Code Allocations ____________________________________________________________ 158
Codepad Connections For Partitioning ___________________________________________________159
Optional Equipment______________________________________________________________ 161
Optional Equipment___________________________________________________________________162

Terminals and Descriptions _______________________________________________________ 169
Terminal Definitions and Descriptions ___________________________________________________ 170
Glossary Of Terms ___________________________________________________________________ 171
Solution 6+6 Wireless - AE Wiring Diagram ______________________________________________ 173
Solution 6+6 Wireless - AE Component Overlay___________________________________________ 174
Connection Diagram For Radio Receiver_________________________________________________ 175
Telecom Connection Diagrams _________________________________________________________ 176
Appendices_____________________________________________________________________ 177
Appendix A _________________________________________________________________________ 178
Telephone Anti-Jamming ______________________________________________________________________ 178
Appendix B _________________________________________________________________________ 179
Test Reports Only When Armed_________________________________________________________________ 179
Specifications___________________________________________________________________ 181
Warranty Statement __________________________________________________________________ 182
Specifications________________________________________________________________________ 182
Software Version Number______________________________________________________________________ 182
Advice To Users _____________________________________________________________________________ 183
New Zealand Telepermit Notes__________________________________________________________________ 183
Programming Sheets_____________________________________________________________ 185
Index _________________________________________________________________________ 191


Introduction
This section includes the following;
•Introduction
•Features
•Quick Start

Introduction Congratulations on selecting the Solution 6+6 Wireless - AE control panel for your
installation. So that you can obtain the most from your unit, we suggest that you take the time
to read through this manual and familiarise yourself with the numerous outstanding operating
and installation features of this system.
You will notice that in all aspects of planning, engineering, styling, operation, convenience and
adaptability, we have sought to anticipate your every possible requirement. Programming
simplicity and speed have been some of the major considerations and we believe that our
objectives in this area have been more than satisfied.
This installation manual will explain all aspects of programming the Solution 6+6
Wireless - AE control panel from factory default to final commissioning. All system
parameters and options are detailed, however, suitability is left up to the individual. Every
control panel can be tailored to meet all requirements quickly and easily. The programming
simplicity will make your installation quick, accurate and rewarding each and every time.
The Solution range of control panels are very popular amongst thousands of people
throughout many countries of the world, all who have various levels of technical aptitude and
ability. We have tried to aim this installation manual to all levels of readers.
As the Solution control panels continue to be improved over the years, they have become
very powerful. Some of its early first-time users have advanced to true "power users" and we
need to address their needs too, while maintaining the simplicity of the manual and the product.
16
Solution 6+6 Wireless - AE Installation Manual
ISSUE120.DOC Electronics Design and Manufacturing Pty Limited

Features The Solution 6+6 Wireless - AE security system uses the very latest in microprocessor
technology to provide you with more useful features and superior reliability and performance.
Following is a list of the main features that the control panel will provide.
Eight Programmable User Codes
Eight Additional Radio Remote User Codes
Codepad Duress, Panic, Fire, Medical Alarms
STAY Mode and AWAY Mode Operation
Entry and Exit Warning Beeper
Six Fully Programmable Hard Wired Or Wireless Burglary Zones
Six 24 Hour Tamper Zones
Partitionable To 2 Areas
Zone Lockout
Sensor Watch
Day Alarm
Dynamic Battery Testing
Remote Arming
Answering Machine Bypass
AC Fail and System Fault Indicators
Event Memory Recall
Walk Test Mode
Upload/Download Programmable
Monitored Siren Output
Strobe Output
Relay Output
EDMSAT – Satellite Siren Compatible
Separate Fire Alarm Sound
Securitel Compatible
Introduction 17
Electronics Design and Manufacturing Pty Limited ISSUE120.DOC

Quick Start The following steps will enable you to use the Solution 6+6 Wireless - AE control
panel with the factory default values. The factory default values allow the control panel to
communicate in the Contact ID format.
1. Connect the AC plug pack to the control panel.
2. Check the operation of the red overload indicator (LD1) on the PCB. In normal
operation the indicator will not illuminate. The MAINS indicator will remain on as will
the AWAY indicator. The system is now in the armed state.
3. Enter the factory default Master Code 2580 followed by the button. The
AWAY indicator will extinguish. The system is now in the disarmed state. Installer’s
Programming Mode can now be accessed.
4. The back-up battery should now be connected.
5. Enter the factory default Installer Code 1234 followed by the button. The
STAY and AWAY indicators will now flash simultaneously to indicate that you have
now entered Installer’s Programming Mode.
6. Enter the Primary Telephone Number followed by the Secondary Telephone Number
and the Subscriber ID Number.
7. Set the time for the test reports if required. Any other programming changes required
may also be made, otherwise the factory default settings will be used.
8. Enter Installer’s Command 960 followed by the button to exit Installer’s
Programming Mode. The system will now return to the disarmed state and is now ready
for use. Refer to “Installer’s Programming Commands” on page 24 for more
information
9. Use the Master Code to set the date and time.
How To Set The New Date and Time
1. Enter your followed by 6and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
2. Enter the day, month, year, hour and minute using the (DD, MM, YY, HH, MM)
format.
3. Press the button when finished.
Two beeps will be heard and the STAY and AWAY indicators will extinguish.
Zone Defaults
The default zone settings are as listed in the table below.
Zone No Zone Type
1 Delay-1
2 & 3 Handover
4 & 5 Instant
6 24 Hour Zone
Table 1: Zone Defaults
18
Solution 6+6 Wireless - AE Installation Manual
ISSUE120.DOC Electronics Design and Manufacturing Pty Limited

Programming
This section includes the following;
•Programming
•Programming With The Remote Codepad
•Programming With The Hand Held Programmer
•Programming With The Programming Key
•Programming Option Bits
•Installer’s Programming Commands
•Disable Factory Default
•Defaulting The Control Panel

Programming The programming options of this control panel are stored in a non-volatile Eprom. This
memory will hold all the relevant configuration and user specific data even during a total
power loss.
The data retention time is as long as ten years without power, therefore, no reprogramming will
be required after powering the control panel down.
The data can be altered as many times as required without the need for any additional
specialised equipment. This memory is laid out in numerous locations, each of which holds the
data for a specific function.
15 is the maximum value that can be programmed into any location.
In general, the entire programming sequence will consist of nominating the location number
required and then entering or altering the data. You will repeat this procedure until all the data
has been programmed to suit your requirements. The factory default settings have been
selected for reporting in the Contact ID Format.
There are two programming modes. The Installer's Programming Mode and the Operators
Programming Mode. Both programming modes have individual access codes and these two
codes must always be programmed differently. The Master Code, as well as being able to arm
and disarm the system gives access to the Operators Programming Mode. The Installers Code
only gives access to the Installer's Programming Mode and does NOT arm and disarm the
system.
Programming of the Solution 6+6 Wireless - AE control panel can be carried out via
any of the following four methods.
•System Codepad
•Hand Held Programmer (CC814)
•Programming Key (CC891)
•Alarm Link Upload/Download Software (CC816)
20
Solution 6+6 Wireless - AE Installation Manual
ISSUE120.DOC Electronics Design and Manufacturing Pty Limited
Other manuals for Solution 6+6 Wireless-AE
1
Table of contents
Other EDM Security System manuals