Alltime 16A/250 AC1 User manual

Sealable cover of the front panel, easy setting by 4 keys.
Automatic summer/winter time changeover
LCD display with backlight
Holiday mode.
single channel
Features
Technical data
Screen display and keys
Operating instruction
1 2 34567
C1
Days of the week Monday, Tuesday, ...Sunday
Channel 1
Relay status
Automatic mode
Manual mode
Holiday mode
Winter time
Summer time
Program setting
Prog
Description
Menu
Symbol legend
Keys
○ Confirm selection
○ Enter main menu
○ Select menu
○
○ Back to main menu
ok
C1
○C1 manual operation
Increase a numerical
value
○ Select menu
○
Decrease a numerical
value
Maximum pilotable power
2300W 2300W 1000W 500W 500W
40 programs
Manual control by keys combination.
Supply terminals
A1-A2
Rated frequency
50/60Hz, 0
Supply volltage tolerance ±10%
Number of channels
Program
weekly program, daily program
Mode of work
Summer/winter time
Time tolerance
Power reserve
Data readout
Number of contacts
Current of contacts
Switching capacity
Mechanical life
Electrical life
manual, automatic, holiday
off, automatic changes
≤1s/day at 25°C
16A/250V AC1
4000VA/AC1,384W/DC
Rated insulation voltage 250V
Permissable relative humidity
≤50%(40°C,without condensation)
Storage temperature
Wire size
Tightening torque
Mounting
Dimensions
Standard
-30°C~70°C
1mm ~ 4mm
0.5Nm
TH-35 Rail(EN60715)
90*36*64mm
IEC60730-1/IEC60730-2-7
Pollution degree
Protection degree
3
IP20
10
10
Altitude
≤2000m
Ambient temperature -20°C~55°C
Rated voltage
Power consumption
Number of programs
6
5
2
2
AC/DC24-264V
Single channel
40
Me nu ok
A2
161518
C1
1
C1
Output - channel 1
Supply terminal A1
Supply terminal A2
LCD display
A1
Control keys
1W
:DD-MM-YY, 23th.September.2013
Menu ok
C1
Pulse
-1-
Alltime Digital Timer -Pulse 16A/250 AC1
9 years +
LCD display with backlight
1 C/O
Model Alltime 16A/250 AC1
Alltime Digital timer Signal controller is used for acoustic signalling
control at factories, offices, farms and schools. It runs in an automatic
mode according to the preset programs
There is an internal battery which can protect real time clock and all
the settings when the electric power supply is off for 9 years +.
Factories, offices, farms & school signal controller
9 + yeasr power reserve(lithium battery).
Automatic transfer of weekdays.
24-264VAC/DC input supply.
Double-module, mounted on TH-35 DIN rail.

Main menu
Initial operation
1
2
3
4
5
6
Select adequate year with “ ” keys and press “Ok” key.
Select adequate month with “ ” keys and press “Ok” key.
Select adequate day with “ ” keys and press “Ok” key.
Select adequate hour with “ ” keys and press ” Ok” key.
Select adequate minute with “ ” keys and press ” Ok” key.
Note: If the settings were not ended and not operate by keys for 2 minutes, device will return to menu.
Select the desired language with “ ” keys and press “Ok” key.
123456
1
2
3
4
5
6
7
Program setting menu
Time setting menu
Date setting menu
Summer/winter setting menu
Holiday mode setting menu
Language setting menu
End settings and exit from menu
Press MENU key to enter menus setting, and symbol Prog appears.
If not operated for 1 minute, the device will automatically exit from setting.
Select the desired menu by pressing “ ” keys.
1
23456
Prog Prog Prog Prog Prog Prog
OK OK OK OK OK
Menu
C1
1
Prog Prog Prog Prog Prog Prog
Prog
7
Long press 0.5s, increase the numerical value quickly
Long press 0.5s, decrease the numerical value quickly
Prog
OK OK OK
Prog Prog Prog
Menu
1 2 3 4
Set time
1
2
3
4
Select TIME and press “Ok” key.
Select adequate minute with“ ” keys and press“Ok” key. adjusting range is 0~59.
Exit from the setting by pressing“Menu” key.
Select adequate hour with“ ” keys and press “Ok” key. adjusting range is 0~23.
Prog
OK OK OK OK
Prog Prog Prog Prog
Menu
12345
1
2
3
4
5
Select DATE and press “Ok” key.
Select adequate year with“ ” keys and press“Ok” key. adjusting range is 2000~2095.
Select adequate month with“ ” keys and press“Ok” key.
Select adequate day with“ ” keys and press“Ok” key.
Exit from the setting by pressing“Menu” key.
Set date
Long press 0.5s, increase the numerical value quickly
Long press 0.5s, decrease the numerical value quickly
Menu
2s
7
Press “Menu” key, the model of the device will display for 2 seconds
-2-
7

OK OK
Prog ProgProg
OK
Prog
Menu
OK
OK OK
Prog Prog
Create a new program
123
1
2
3
4
5
6
7
8
Select PROGRAM and press “Ok” key.
Select NEW and press “Ok” key.
Display the number of new program and press “Ok” key.
When the programs memory is full, new program will not be created, symbol “ ” appears on the screen.
Set the hour with “ ” keys and press “Ok” key.
Set the minute with “ ” keys and press “Ok” key.
Exit from the setting by pressing “Menu” key.
Set the program activity on a week day( from Monday to Sunday) with “ ” key
If is selected, program operation is enabled for flashing day. If is selected, program is not used for flashing day.
45
6
OK
1
Prog
2
3
4
5
6
7
Prog
78
1
2
Select SU-WI and press “Ok” key.
1 2
312
7
8
9
10
345
6
11 12 13
Set the start month of summer time and press “Ok” key.
Set the start day of summer time and press “Ok” key.
Set the start month of winter time and press “Ok” key.
Set the start day of winter time and press “Ok” key.
Select the required summer/winter
Exit from the setting by pressing “Menu” key.
Switchover summertime/wintertime
4
5
6
13
11
78
910
Prog
Prog
Prog
Prog
Prog Prog
Prog
Prog
OK OK
OK
OK OK OK
OK
OK
Prog Prog Prog
Prog Prog
OK
Menu
Menu
Menu
Menu
mode with “ ” keys and press“Ok” key.
Freely programmed Freely programmed
Free sum/win
Europe sum/win
U.S.A sum/win
No sum/win
Display Function Summer switching Winter switching
Last Sunday in March
Second Sunday in March
None
Last Sunday in October
First Sunday in November
None
Long press 0.5s, increase the numerical value quickly
Long press 0.5s, decrease the numerical value quickly
OK
Prog
Set bell ring duration with “ ” keys and press “Ok” key. The setting range is 0-59s.
-3-

Modify a program
Delete a program
1 2 3 4 6
5
7
8
9
1
2
3
4
5
6
7
8
9
10
Select PROGRAM and press “Ok” key.
Select DELETE and press “Ok” key.
Select SINGLE to delete single program and press “Ok” key.
Select or with “ ” keys and press “Ok” key.
Return to SINGLE sub-menu, Exit from the setting by pressing “ Menu”.
Return to DELETE sub-menu, Exit from the setting by pressing “Menu”.
End program setting.
OK OK OK OK OK
Prog Prog
Prog
Prog
ProgProg
Menu
Prog
Prog
Prog
Prog
OK OK
Menu
Prog
10
Select the desired program with “ ” keys and press “Ok” key.
Select “ ” or “ ” with “ ” keys and press “Ok” key.
Select ALL to delete all programs and press “Ok” key.
OK OK
ProgProg
OK
Prog
Menu
OK
OK OK
Prog Prog
123
1
2
3
4
5
6
7
8
Select PROGRAM and press “Ok” key.
Select REVIEW and press “Ok” key.
Set the hour with “ ” keys and press “Ok” key.
Set the minute with “ ” keys and press “Ok” key.
Exit from the setting by pressing “Menu” key.
Set the program activity on a week day( from Monday to Sunday) with “ ” key
If is selected, program operation is enabled for flashing day. If is selected, program is not used for flashing day.
45
6
OK
1
Prog
2
3
4
5
6
7
Prog
78
Long press 0.5s, increase the numerical value quickly
Long press 0.5s, decrease the numerical value quickly
OK
Prog
Set bell ring duration with “ ” keys and press “Ok” key. The setting range is 0-59s.
Select the desired program with “ ” keys and press “Ok” key.
1 2 345
Prog
1 2 345
Prog
-4-

Holiday program
123 4 65
8 9
7
1110
OK OK
OK
OK OK OK OK
OK OK
Prog
Prog
Prog Prog Prog Prog Prog
Prog Prog
Prog
Menu
Prog
Menu
1
2
3
4
5
6
Select HOLIDAY and press “Ok” key.
Select ON to activate holiday mode and press “Ok” key.
Set the start year of holiday with “ ” keys and press “Ok” key.
Set the end year of holiday with “ ” keys and press “Ok” key.
Set the start month of holiday with “ ” keys and press “Ok” key.
Set the start day of holiday with “ ” keys and press “Ok” key.
Set the end month of holiday with “ ” keys and press “Ok” key.
Set the end day of holiday with “ ” keys and press “Ok” key.
Return to HOLIDAY menu. Exit from the setting by pressing “Menu” key.
Select OFF to deactivate holiday mode and press “Ok” key.
Return to HOLIDAY menu. Exit from the setting by pressing “Menu” key.
7
8
9
10
11
Long press 0.5s, increase the numerical value quickly
Long press 0.5s, decrease the numerical value quickly
Language setting
1
2
3
4
Select PROGRAM and press “Ok” key.
Select REVIEW and press “Ok” key.
View the operation of the set programs with“ ” keys and press “Ok” key.
Exit from the setting by pressing “ Menu” key.
Check a program
1 2 3 4
OK OK
Prog ProgProg
Menu
Menu
1 2 345
Prog
1
2
3
Select LANGUAGE and press “Ok” key.
Select the desired language with “ ” and press “Ok” key
Exit from the setting by pressing “Menu” key.
Select menu language
1
2 3
Menu
OK
Prog
Prog
Prog
Prog
Prog
Prog Prog
Prog Prog
Prog Prog
OK
-5-

WARNING
-Please disconnect the power supply before installation.
-Connect the supply voltage as stated on the product.
Safety instruction
Wiring diagram
L
N
C1
Me nu ok
A1
A2
161518
C1
A1
16
15
18
A2
Dimensions
36
35
45
90
26
44
60
65
Me nu o k
A2
161518
C1
A1
Reset
Press the four keys simultaneously for 3 seconds to reset automatically. The device was restored to factory settings.
Menu ok
Keys combination for MANUAL control
C1
Press “ ” keys simultaneously, the output state of channel 1 switches to MANUAL.
When the output states of other operation modes was changed, Manual mode exits automatically.
-6-
1.The device should be installed, operated and maintained by qualified
personnel.
2.Don’t dismantle or repair the device whether it operates normally,
otherwise no responsibility is assumed by manufacturer or seller.
3.Please refer to wiring diagram when connecting.
4.Never use the product at the site which can be invaded by corrode
gas, strong sunshine light or rain.
5.(c) Copyright 2017 { Alltime Australia } All Rights Reserved.| Alltime is a
trade mark owned by Alltime Australia.
Table of contents
Popular Timer manuals by other brands

Grasslin
Grasslin Digi 322 operating instructions

Theben
Theben TR 611 top3 quick start guide

Clas Ohlson
Clas Ohlson 34-2361 operating instructions

Mitsubishi Electric
Mitsubishi Electric PAC-SC32PTA Instruction book

Utilitech
Utilitech TM-097 S owner's guide

Eaton
Eaton easy500 Series Installation operation & maintenance