manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ENDA
  6. •
  7. Timer
  8. •
  9. ENDA ETM1411 User manual

ENDA ETM1411 User manual

SETSET
ETM1411
ENDA DIGITAL TIMER
STOP
START
OUT MIN
HOUR
TECHNICAL SPECIFICATIONS
Supply 230V AC +10 -20 , 50/60Hz or 24% % V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz± ±
Power consumption Max 4VA
2.5mm² screw-terminal connections
±1%
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 ( )pollution degree 2, overvoltage category II
START INPUT
Input type Control with mechanical contact.
Min. = 100ms
On and Off times for input
pulses
OUTPUT
ELEKTRÝKSEL ÖZELLÝKLER
OUT Relay: 250V AC, 8A ( ), NO+NCfor resistive load
Mechanical 30.000.000 operation; Electrical 100.000 operation
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height 2000mMax.
80% up to 31°C decreasing linearly 50% at 40°C.
Ambient/storage temperature
Max. Relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Selectable 99:59 min. or hour.
1 sec.
Rated pollution degree According to EN 60529 Front panel : IP65
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
HOUSING
Housing type Suitable for flush-panel mounting
Dimensions W77xH35xD71mm
Weight Approx. 198g (after packing)
Enclosure material Self extinguishing plastics
Thank you for choosing ENDA ETM1411 digital timer.
* 35x 77mm sized.
* Single contact output for timing control.
* External start input.
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 mins.
0:01 .... 99:59 hrs.
* Decrease and increace step of time can be adjusted.
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be
adjusted.
* CE marked according to European Norms.
Connection Diagram
ENDA ETM1411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations.
1/2
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr ETM1411-E-05-R
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1)
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
Mains supply cords shall meet the requirements of
ENDA ETM1411 DIGITAL TIMER
Please read this document carefully before using this product. Theguarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. Thecompany shall not be responsible for any damageor losses however
caused, whichmay be experienced as a result ofthe installation or use of this product.
Order Code : ETM1411-     
1Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
1-
24V AC/DC 10%
50/60Hz 4VA
±
SN: XXXXXXXXX
ETM1411-24
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
OUT
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
START
SN: XXXXXXXXX
ETM1411-230VAC
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
START
12V AC/DC 10%
50/60Hz 4VA
±
SN: XXXXXXXXX
ETM1411-12
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
OUT
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
START
Panel cut-out
Dimensions
Note :
1) Panel thickness
should be maximum
7 mm.
2) If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the
Panel.
71mm
29mm
Flush mounting
clamp
For removing mounting clamps:
Push the flush-mounting
clamp in direction 1as shown
in the figure below. Then, pull
out the clamp in direction 2.
1
35mm
77mm
SETSET
ETM1411
ENDA DIGITAL TIMER
STOP
START
OUT MIN
HOUR
SN: XXXXXXXXX
ETM1411-230VAC
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
START
Flush mounting
clamp
Depth
Panel
2
71mm 5mm
Rubber
packing
The lower limit
of the setpoint.
Adjustable between
0.01 and T.uPl.
The upper limit
of the setpoint.
Adjustable between
T.lol and 99.59.
Selection of start type.
By external start input and
start/stop keys, timer can be run
and stopped. 4 different selection
types are defined in the
control diagram.
Selection of relay output.
If typ.0 is selected, timer runs
by start and relay contact shuts.
When time is over, relay contact
opens. If typ.1 is selected, timer
runs by start. When time is over,
relay contact shuts.
Selection of buzzer sound.
Adjustable 16 different sounds.
If this parameter is selected 0,
warning tone is canceled.
Selection of time unit.
If min is selected, time can be
adjutable max. 99:59 min.
If Hour is selected, time can be
adjutable max. 99:59 h.
Increase or decrease
step of the setpoint.
Adjustable between
1 and 30.
When pressed key, TIMER set value flashes and by using and keys the value can be adjusted
with the step defined byIn.de.
Programming Mode
Run Mode
Time
value
T.lol
T.uPl Str.t.
Str.t.
Str.t.
In.de Out.t.
Sond.
Out.t.
Out.t.
TYP.0
TYP.1
TYP.2
TYP.3
1000
ETM1411-E-05-R
If key is pressed and held for 3 seconds,
programming mode is entered.
:
30 59
:
60 00
:
59 59
:
60 00
SET
T.bas S.Cod. Access code for entering
security menu.
This parameter should be 411.
Access code for
timer configuration menu.
A.-t.S.
A.-T.c.
Access code for timer set menu
If key is pressed,
run mode is entered.
T.S. T.c. SE
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. For adjusting the selected parameter, while holding key, the value can be
adjusted by using and keys.
When held down for one second in the run mode, timer runs.
run mode. When held down for a few seconds, the change rate accelerates.
Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the
When held down for one second in the run mode, timer and voiced warning are stopped.(When Str.t. = TYP.1 mode is selected, timer and voiced warning can be stopped if external start input is off). Used
for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
INDICATOR OF
SELECTING
HOUR
INDICATOR OF
SELECTING
MINUTE
INDICATOR OF
CONTACT OUTPUT
Displayed time value in the run mode, parameter value or name in the programming mode.
2/2
Power
Power
Power
Power
Out
Out
Out
Out
Start
input
Start
key
Start
input
Start
key
Stop
key
Stop
key
Stop
key
Indicator
Indicator
Indicator
Indicator
CONTROL DIAGRAM BY EXTERNAL START INPUT
CONTROL DIAGRAM BY START & STOP KEYS
NonE= Menu is invisible.
P.yes= Parameters of menu
are changeable.
P.no= Parameters of menu
are only visible.
NonE= Menu is invisible.
P.yes= Parameters of menu
are changeable.
P.no= Parameters of menu
are only visible.
TYP.0
TYP.0
TYP.0
TYP.1
TYP.1
SETSET
ETM1411
ENDA DIGITAL TIMER
STOP
START
OUT MIN
HOUR

Other ENDA Timer manuals

ENDA ETM742 Operating instructions

ENDA

ENDA ETM742 Operating instructions

ENDA ETM1411 Series User manual

ENDA

ENDA ETM1411 Series User manual

ENDA PTM232 User manual

ENDA

ENDA PTM232 User manual

ENDA ATP4 User manual

ENDA

ENDA ATP4 User manual

ENDA ETM442 Series User manual

ENDA

ENDA ETM442 Series User manual

ENDA ATM9321 User manual

ENDA

ENDA ATM9321 User manual

ENDA EM4401 Series User manual

ENDA

ENDA EM4401 Series User manual

Popular Timer manuals by other brands

Tork TU40 quick start guide

Tork

Tork TU40 quick start guide

hager EH710 manual

hager

hager EH710 manual

Intermatic HB35K instruction manual

Intermatic

Intermatic HB35K instruction manual

Grasslin Towerchron QM1 Installation and user instructions

Grasslin

Grasslin Towerchron QM1 Installation and user instructions

Tempatron UMT500 instructions

Tempatron

Tempatron UMT500 instructions

POWER ZONE 900-1165 instruction manual

POWER ZONE

POWER ZONE 900-1165 instruction manual

TFA Shake Awake operating manual

TFA

TFA Shake Awake operating manual

mumbi m-DZ3600 user manual

mumbi

mumbi m-DZ3600 user manual

Kemo Electronic B042 manual

Kemo Electronic

Kemo Electronic B042 manual

ABB DWA1 user manual

ABB

ABB DWA1 user manual

Ambient NanoLockit quick start guide

Ambient

Ambient NanoLockit quick start guide

Enerlites HET01 installation instructions

Enerlites

Enerlites HET01 installation instructions

EG C846 instructions

EG

EG C846 instructions

Velleman Timer10 user manual

Velleman

Velleman Timer10 user manual

Elko SHT-1 manual

Elko

Elko SHT-1 manual

hager EH010 quick start guide

hager

hager EH010 quick start guide

Perel LEDC06 user manual

Perel

Perel LEDC06 user manual

VOCOO VC5260 manual

VOCOO

VOCOO VC5260 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.