ALTA LABS Injector-POE+ User manual

LAN
POE
POWER
QUICK START GUIDE
MODEL: Injector-POE+
SCAN FOR OTHER LANGUAGES

Package Contents
LAN
POE
POWER
Injector-POE+
Power Cord
Note: Be sure to read all of the
instructions before installation.
Installation Requirements
• 2 Ethernet cables (CAT 5 or above)
• Phillips screwdriver for mounting
• Drill and drill bit for mounting
• Screws and anchors for mounting

Hardware Overview
Front
LAN POE
LAN This port is used to connect
to your wired network. You're not
required to use this connection
as you can use the powered AP
in mesh mode. While this is an
optional connection, it is highly
recommended for optimal
performance. An Ethernet cable
connects this port to your broadband
router, non-PoE+ network switch, or
other appropriate non-PoE+ network
connection.
POE This port is used to connect to
your PoE+ powered device such as
the AP6 or AP6-Pro WiFi 6 Access
Point. In mesh mode, only power is
delivered via Ethernet. If the LAN is
connected, data is also delivered over
the Ethernet connection.

Back
POWER This port is where the
included power cord connects. The
other end is connected to a power
source such as a power outlet or
power strip.
Top
POWER
POWER LED The LED will illuminate
white when the Injector-POE+ is
properly connected to a power
source.

Connecting the Injector
1. Plug the power cord into the
Injector-POE+ and the other end
into a power strip or power outlet.
2. Plug an Ethernet cable from the
POE port on the Injector-POE+ to
the Ethernet port on your AP.
3. Optional (highly recommended)
Note: If this step is skipped, the
AP will operate in mesh mode.
Plug an Ethernet cable into the
LAN port on the Injector-POE+
and plug the other end into your
network port, non-PoE+ switch
port, or router port.
POWER
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24 SFP 1 SFP 2
DOWN
10/100
1000
LINK
1/2.5/5/10 G
DOWN

Specifications
Model: Injector-POE+
Dimensions 4.5 x 2.1 x 1.3"
(113.6 x 53.5 x 33.5 mm)
Weight 0.3 lbs
(145 g)
Network Interface Ethernet
Ports (2) GbE RJ45 Port
LED White
Input Voltage 100V~240Vac
AC Input Voltage
Frequency Range 50~60Hz
AC Input Current 0.7A(Max)
Output Voltage 48V
Output Current 0.63A
Mounting Wall
Operating
Temperature
32 to 104° F
(0 to 40° C)
Storage
Temperature
-22 to 158° F
(-30 to 70° C)
Operating
Humidity
35 to 90% RH
Noncondensing
Certifications CE, FCC, IC

Safety Notice
1. Please read and follow these
instructions.
2. Please read and follow the installation
instructions found on the Quick Start
Guide by scanning the QR code on this
document.
3. Please notice all warnings provided by
Alta Labs.
4. Please only use this device as it is
intended.
5. Only use accessories and attachments
as recommended by Alta Labs.
WARNING: To reduce the risk
of electric shock, please do
not submerge this product
in water.
Electrical Safety Information
1. Please follow the recommended
power rating as it pertains to voltage,
frequency, and current found in the
Alta Labs product documentation.
Failure to do so may result in product
damage, failure, malfunction, or even
fire.
2. Please do not attempt to open or
pierce the device enclosure or conduct
any repair work on the device. Failure
to comply may result in electric shock.
3. Whether utilizing a PoE Injector or PoE
enabled network switch, please ensure
appropriate grounding is in place.
Declaration of Conformity
Soundvision Technologies, dba
Alta Labs, hereby declares that this
device conforms with the essential
requirements and provisions of
Directives 2014/53/EU, 2014/30/EU and
2014/35/EU. To see the full EU declaration
and other conformity information,
please see
www.alta.inc/regulatory

Compliance
Federal Communication Commission
Interference Statement
This product has been tested and found
to comply with the limits for a Class B
digital device pursuant to Part 15 of the
FCC Rules. These limits are designed
to provide reasonable protection
against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates,
uses, and can radiate radio frequency
energy and, if not installed and used in
accordance with the instruction manual,
may cause harmful interference to radio
communications. Operations of this
equipment in a residential area is likely
to cause harmful interference in which
case the user will be required to correct
the interference at his own expense.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does
cause harmful interference to radio
or television reception, which can be
determined by turning the equipment
off and on, the user is encouraged to
try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between
the equipment and receiver.
• Connect the equipment into
an outlet on a circuit different
from that to which the receiver is
connected.
• Consult the dealer or an
experienced radio/TV technician
for help.
FCC Caution
This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful
interference, and

(2) This device must accept any
interference received, including
interference that may cause
undesired operation.
This device is restricted to indoor use.
Non-Modification Statement
Changes or modifications not expressly
approved by the party responsible
for compliance could void the user’s
authority to operate the equipment.
FCC Radiation Statement
This equipment complies with FCC
radiation exposure limits set forth for
an uncontrolled environment. This
equipment should be installed and
operated with minimum distance 20 cm
between the radiator and your body.
CAN ICES-003(B) / NMB-003(B)
This device contains license-exempt
transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic
Development Canada’s license-exempt
RSS(s). Operation is subject to the
following two conditions:
(1) This device may not cause
interference.
(2) This device must accept any
interference, including interference
that may cause undesired operation
of the device.
L’émetteur/récepteur exempt de licence
contenu dans le présent appareil
est conforme aux CNR d’Innovation,
Sciences et Développement
économique Canada applicables aux
appareils radio exempts de licence.
L’exploitation est autorisée aux deux
conditions suivantes :
(1) L’appareil ne doit pas produire de
brouillage;
(2) L’appareil doit accepter tout
brouillage radioélectrique
subi, même si le brouillage est
susceptible d’en compromettre le
fonctionnement.
Table of contents
Other ALTA LABS Switch manuals
Popular Switch manuals by other brands

3Com
3Com 3C16611 - SuperStack II Dual Speed Hub 500 user guide

Arista
Arista 7300 Series quick start guide

Radio Shack
Radio Shack AFX-500 owner's manual

Phoenix Contact
Phoenix Contact FL SWITCH SMCS 16TX Installation notes

Allied Telesis
Allied Telesis GS910/XST Series Installation and user guide

IBM
IBM Rack-Based Local Console Switches user guide