ALTA LABS S24-POE User manual

QUICK START GUIDE
MODEL: S24-POE
PoE
OFF
PoE+
57V⎓Max,
0.6A Max
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
DOWN
10/100
1000
LINK
SFP+ 1
LINK/ACT
RESET
SFP+ 2
LINK/ACT

1
Before You Begin
Download the Alta app on your mobile device,
and create your free Alta account.
You may also visit manage.alta.inc to manage
your Alta devices.
manage.alta.inc

2
Package Contents
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
S24-POE
Rack Ears
(Qty. 2)
Rack Ear Screws
(M4x8.5mm, Qty. 8)
Rackstud™DUO
Studs (Qty. 2)
Rackstud DUO
Nuts (Qty. 2)
SFP+ Port Plugs
(Qty. 2)
Power Cord
Note: We recommend using the
included mounting hardware for
product installation.
Installation Requirements
•Ethernet cabling (CAT 5 or above)
•Phillips screwdriver

3
Hardware Overview
Front
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
Alta Labs LED
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
The Alta Labs LED flashes as the unit is
powered up. Once fully booted, the LED will
remain lit unless turned off in the UI. The LED
color can also be changed in the management
interface.

4
Ports and LEDs
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
Ports 1-16 support 802.3at PoE+
with up to 30W per port and a
PoE budget of 240 Watts. These
ports are standard Gigabit
Ethernet ports that support
10/100/1000 Mbps connections.
The Link LED on the left indicates
a 10/100 Mbps connection when
amber, blue indicates a 1 Gbps
connection, and if not illuminated,
the connection is down.
The PoE LED on the right will
illuminate amber when a device
connected to the port is being
powered via Ethernet.
Ports 17-24 are standard Gigabit
Ethernet ports that support
10/100/1000 Mbps connections.
The Link LED indicates a
10/100 Mbps connection when
amber, blue indicates a 1 Gbps
connection, and if not illuminated,
the connection is down.

5
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max
LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13
15
10 12 14
16
17 19 21 23
18 20 22 24 SFP+ 2
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max
LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2
LINK/ACT
The SFP+ Ports support fiber
optic and Ethernet transceivers
with 1 Gbps, 2.5 Gbps, 5 Gbps, or
10 Gbps connections.
The Link LED on the left will
illuminate blue when there is
a 1 Gbps, 2.5 Gbps, or 5 Gbps
connection, it will illuminate
white with a 10 Gbps connection.
The Activity LED on the right
flashes blue when there is activity
on a 1 Gbps, 2.5 Gbps, or 5 Gbps
connection. It will flash white if
there is 10 Gbps network activity.
Back
Input: 100-240V~, 50-60H z, 3A Max.
Input: 100-240V~, 50-60H z, 3A Max.
Cooling fan vents are located on the back of
the switch. Be sure to use the included power
cord to connect power.
Side
The side panels feature cooling vents.

6
Hardware Installation
Rackmount Installation
1. Connect the two Rack Ears to both sides of
the switch using the eight Rack Ear Screws.
PoE
OFF
PoE+
57V⎓Max,
0.6A Max
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
DOWN
10/100
1000
LINK
SFP+ 1
LINK/ACT
RESET
SFP+ 2
LINK/ACT
Note the cooling vents remain exposed with
the Rack Ears connected.
2. Ensure the arrow on the back of the
Rackstud DUO stud is pointing up.
Arrow Up

7
3. Insert the Rackstud DUO stud at the
beginning of the RU space just below the
thin area.
Thin Area
Thin Area
Thick Area
Thick Area
4.Compress the spring and insert the
Rackstud DUO stud from behind the rail.
5. Repeat the same procedure on the opposite
rail on the rack.

8
6. Slide the switch over the Rackstud DUO stud
and apply pressure to the front face while
installing the Rackstud DUO nuts to the
bottom on both sides of the switch.
17 19 21 23
18 20 22 24
SFP+ 1 SFP+ 2
DOWN
10/100
1000
LINK
LINK/ACT LINK/ACT
RESET
7. Connect the top Rackstud DUO nuts on
both sides of the switch.
17 19 21 23
18 20 22 24
SFP+ 1 SFP+ 2
DOWN
10/100
1000
LINK
LINK/ACT LINK/ACT
RESET

9
Mounting On A Wall
1. Connect the two Rack Ears to both sides of
the switch using the eight Rack Ear Screws.
Be sure to orient the Rack Ears so the
openings face the wall.
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2

10
2. Use wall screws and anchors (not included)
to secure both sides of the switch to the wall.
SFP+ 1
DOWN
10/100
1000
LINK
PoE
OFF
PoE+
57V⎓Max,
0.6A Max LINK/ACT
RESET
LINK/ACT
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24 SFP+ 2

11
Connecting Devices
1. Connect devices that need Power over
Ethernet to any of the first sixteen ports. The
ports are autosensing. Devices that do not
require power can be connected to any of
the 24 ports.
PoE
OFF
PoE+
57V⎓Max,
0.6A Max
1 3 5 7
2 4 6 8
9 11 13 15
10 12 14 16
17 19 21 23
18 20 22 24
DOWN
10/100
1000
LINK
SFP+ 1
LINK/ACT
RESET
SFP+ 2
LINK/ACT
2. Follow the instructions included with your
transceivers to connect them to the SFP+
ports. If not using the ports, be sure to place
the SFP+ Port Plugs over the ports.
Set Up Your Device
1. Follow the instructions in the Alta app or
management interface to set up your switch.
1.0
bcb923123426
New Switch
Home Base
Set Up

12
S24-POE Specifications
Mechanical
Dimensions 44 x 254 x 441.5 mm
(1.7 x 10 x 17.4")
Weight 3.6 kg (7.9 lbs)
Material Type SGCC
Material Finish Powder coat - Matte
Color Metallic gray
Ports
Interface Ports (24) 10/100/1000 Mbps
SFP/SFP+ (2) SFP+
Switching Capacity 88 Gbps
Non-blocking Throughput 44 Gbps
Forwarding Rate 65.5 Gbps
PoE Budget/Max 240 Watts
PoE Supply 30 Watts per port
Per Port PoE (16) 802.3at PoE+
Non-PoE Ports (10)
LEDs
PoE Orange
Network Orange: 10/100 Mbps,
Blue: 1000 Mbps
SFP
Blue: Link/Activity (1, 2.5, or 5
Gbps)
White: Link/Activity (10 Gbps)

13
Hardware
Packet Buffer 4.1 Mbit
Mac Table Size 8 K
Energy Efficient Ethernet Yes
Management Factory reset button
Bluetooth Yes, Setup
Power
Max Power Consumption
w/o PoE 53 Watts
Max Power Consumption
Full PoE 295 Watts
Power Supply Universal AC, 100 - 240VAC
50/60Hz Internal
RJ45 Port Surge
Protection
12kV for ESD - contact, 25kV
for ESD - Air
Environmental
Mounting Rackmount, Wallmount
EMI Rating EMI Class-A with 3dB margin
Cooling Fan Yes
Operating Temperature -5 to 50° C (23 to 122° F)
Operating Humidity 10 to 90% Noncondensing
Certifications CE, FCC, IC

14
Compliance
Federal Communication Commission
Interference Statement
This product has been tested and found to comply with the
limits for a Class A digital device pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference
to radio communications. Operations of this equipment
in a residential area is likely to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
FCC Caution
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
This device is restricted to indoor use.
Non-Modification Statement
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.

15
FCC Radiation Statement
This equipment complies with FCC radiation exposure limits
set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance
20cm between the radiator and your body.
CAN ICES-003(A) / NMB-003(A)
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.
L’émetteur/récepteur exempt de licence contenu dans
le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
ISED Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation
exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition
aux rayonnements IC établies pour un environnement
non contrôlé. Cet équipement doit être installé et utilisé
avec un minimum de 20cm de distance entre la source de
rayonnement et votre corps.
The transmitter module may not be co-located with any
other transmitter or antenna.
Le module émetteur peut ne pas être coïmplanté avec un
autre émetteur ou antenne.
Table of contents
Other ALTA LABS Switch manuals